Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

SU-E-T-91: Accuracy of Dose Calculation Algorithms for Patients Undergoing Stereotactic Ablative Radiotherapy

Purpose: The purpose of this study was to investigate and quantify the variation in dose distributions in small field lung cancer radiotherapy using seven different dose calculation algorithms. Methods: The study was performed in 21 lung cancer patients who underwent Stereotactic Ablative Body Radiotherapy (SABR). Two different methods (i) Same dose coverage to the target volume (named as same dose method) (ii) Same monitor units in all algorithms (named as same monitor units) were used for studying the performance of seven different dose calculation algorithms in XiO and Eclipse treatment planning systems. The seven dose calculation algorithms include Superposition, Fast superposition, Fast Fourier Transform ( FFT) Convolution, Clarkson, Anisotropic Analytic Algorithm (AAA), Acurous XB and pencil beam (PB) algorithms. Prior to this, a phantom study was performed to assess the accuracy of these algorithms. Superposition algorithm was used as a reference algorithm in this study. The treatment plans were compared using different dosimetric parameters including conformity, heterogeneity and dose fall off index. In addition to this, the dose to critical structures like lungs, heart, oesophagus and spinal cord were also studied. Statistical analysis was performed using Prism software. Results: The mean±stdev with conformity index for Superposition, Fast superposition, Clarkson and FFT convolution algorithms were 1.29±0.13, 1.31±0.16, 2.2±0.7 and 2.17±0.59 respectively whereas for AAA, pencil beam and Acurous XB were 1.4±0.27, 1.66±0.27 and 1.35±0.24 respectively. Conclusion: Our study showed significant variations among the seven different algorithms. Superposition and AcurosXB algorithms showed similar values for most of the dosimetric parameters. Clarkson, FFT convolution and pencil beam algorithms showed large differences as compared to superposition algorithms. Based on our study, we recommend Superposition and AcurosXB algorithms as the first choice of algorithms in lung cancer radiotherapy involving small fields. However, further investigation by Monte Carlo simulation is required to confirm our results.

60 APPLIED LIFE SCIENCES↗

SU-E-T-216: Comparison of Volumetrically Modulated Arc Therapy Treatment Using Flattening Filter Free Beams Vs. Flattened Beams for Partial Brain Irradiation

Purpose: Flattening Filter Free (FFF) beams offer the potential for higher dose rates, short treatment time, and lower out of field dose. Therefore, the aim of this study was to investigate the dosimetric effects and out of field dose of Volumetric Modulated Arc Therapy (VMAT) plans using FFF vs Flattening Filtering (FF) beams for partial brain irradiation. Methods: Ten brain patients treated with a 6FF beam from a Truebeam STX were analyzed retrospectively for this study. These plans (46Gy at 2 Gy per fraction) were re-optimized for 6FFF beams using the same dose constraints as the original plans. PTV coverage, PTV Dmax, total MUs, and mean dose to organs-at-risk (OAR) were evaluated. In addition, the out-of-field dose for 6FF and 6FFF plans for one patient was measured on an anthropomorphic phantom. TLDs were placed inside (central axis) and outside (surface) the phantom at distances ranging from 0.5 cm to 17 cm from the field edge. Paired T-test was used for statistical analysis. Results: PTV coverage and PTV Dmax were comparable for the FF and FFF plans with 95.9% versus 95.6% and 111.2% versus 111.9%, respectively. Mean dose to the OARs were 3.7% less for FFF than FF plans (p<0.0001). Total MUs were, on average, 12.5% greater for FFF than FF plans with 481±55 MU (FFF) versus 429±50 MU (FF), p=0.0003. On average, the measured out of field dose was 24% less for FFF compared to FF, p<0.0001. A similar beam-on time was observed for the FFF and FF treatment. Conclusion: It is beneficial to use 6FFF beams for regular fractionated brain VMAT treatments. VMAT treatment plans using FFF beams can achieve comparable PTV coverage but with more OAR sparing. The out of field dose is significant less with mean reduction of 24%.

60 APPLIED LIFE SCIENCES↗

SU-E-T-483: In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)

Purpose: To investigate the accuracy, sensitivity and constancy of integral quality monitor (IQM), a new system for in vivo dosimetry of conventional intensity modulated radiation therapy (IMRT) or rotational volumetric modulated arc therapy (VMAT) Methods: A beta-version IQM system was commissioned on an Elekta Infinity LINAC equipped with 160-MLCs Agility head. The stationary and rotational dosimetric constancy of IQM was evaluated, using five-field IMRT and single-or double-arc VMAT plans for prostate and head-and-neck (H&N) patients. The plans were delivered three times over three days to assess the constancy of IQM response. Picket fence (PF) fields were used to evaluate the sensitivity of detecting MLC leaf errors. A single leaf offset was intentionally introduced during delivery of various PF fields with segment apertures of 3×1, 5×1, 10×1, and 24×1cm2. Both 2mm and 5mm decrease in the field width were used. Results: Repeated IQM measurements of prostate and H&N IMRT deliveries showed 0.4 and 0.5% average standard deviation (SD) for segment-by-segment comparison and 0.1 and 0.2% for cumulative comparison. The corresponding SDs for VMAT deliveries were 6.5, 9.4% and 0.7, 1.3%, respectively. Statistical analysis indicates that the dosimetric differences detected by IQM were significant (p < 0.05) in all PF test deliveries. The largest average IQM signal response of a 2 mm leaf error was found to be 2.1% and 5.1% by a 5mm leaf error for 3×1 cm2 field size. The same error in 24×1 cm2 generates a 0.7% and 1.4% difference in the signal. Conclusion: IQM provides an effective means for real-time dosimetric verification of IMRT/ VMAT treatment delivery. For VMAT delivery, the cumulative dosimetry of IQM needs to be used in clinical practice.

60 APPLIED LIFE SCIENCES↗

SU-E-T-759: To Replan Or Not To Replan for Each Fraction Using Inverse Optimization for Multichannel Vaginal Cylinder

Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions. A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-760: Tolerance Design for Site-Specific Range in Proton Patient QA Process Using the Six Sigma Model

Purpose: To show how tolerance design and tolerancing approaches can be used to predict and improve the site-specific range in patient QA process in implementing the Six Sigma. Methods: In this study, patient QA plans were selected according to 6 site-treatment groups: head &neck (94 cases), spine (76 cases), lung (89 cases), liver (53 cases), pancreas (55 cases), and prostate (121 cases), treated between 2007 and 2013. We evaluated a model of the Six Sigma that determines allowable deviations in design parameters and process variables in patient-specific QA, where possible, tolerance may be loosened, then customized if it necessary to meet the functional requirements. A Six Sigma problem-solving methodology is known as DMAIC phases, which are used stand for: Define a problem or improvement opportunity, Measure process performance, Analyze the process to determine the root causes of poor performance, Improve the process by fixing root causes, Control the improved process to hold the gains. Results: The process capability for patient-specific range QA is 0.65 with only ±1 mm of tolerance criteria. Our results suggested the tolerance level of ±2–3 mm for prostate and liver cases and ±5 mm for lung cases. We found that customized tolerance between calculated and measured range reduce that patient QA plan failure and almost all sites had failure rates less than 1%. The average QA time also improved from 2 hr to less than 1 hr for all including planning and converting process, depth-dose measurement and evaluation. Conclusion: The objective of tolerance design is to achieve optimization beyond that obtained through QA process improvement and statistical analysis function detailing to implement a Six Sigma capable design.

60 APPLIED LIFE SCIENCES↗

TU-AB-303-05: Clinical Guidelines for Determining When An Adaptive Replan May Be Warranted for Head and Neck Patients

Purpose: Tools are now available to perform daily dose assessment in radiotherapy, however, guidance is lacking as to when to replan to limit increase in normal tissue dose. This work performs statistical analysis to provide guidance for when adaptive replanning may be necessary for head/neck (HN) patients. Methods: Planning CT and daily kVCBCT images for 50 HN patients treated with VMAT were retrospectively evaluated. Twelve of 50 patients were replanned due to anatomical changes noted over their RT course. Daily dose assessment was performed to calculate the variation between the planned and delivered dose for the 38 patients not replanned and the patients replanned using their delivered plan. In addition, for the replanned patients, the dose that would have been delivered if the plan was not modified was also quantified. Deviations in dose were analyzed before and after replanning, the daily variations in patients who were not replanned assessed, and the predictive power of the deviation after 1, 5, and 15 fractions determined. Results: Dose deviations were significantly reduced following replanning, compared to if the original plan would have been delivered for the entire course. Early deviations were significantly correlated with total deviations (p<0.01). Using the criteria that a 10% increase in the final delivered dose indicates a replan may be needed earlier in the treatment course, the following guidelines can be made with a 90% specificity after the first 5 fractions: deviations of 7% in the mean dose to the inferior constrictors and 5% in the mean dose to the parotid glands and submandibular glands. No significant dose deviations were observed in any patients for the CTV -70Gy (max deviation 4%). Conclusions: A 5–7% increase in mean dose to normal tissues within the first 5 fractions strongly correlate to an overall deviatios in the delivered dose for HN patients. This work is funded in part by NIH 2P01CA059827-16.

60 APPLIED LIFE SCIENCES↗

Quantitative correlational study of microbubble-enhanced ultrasound imaging and magnetic resonance imaging of glioma and early response to radiotherapy in a rat model

Purpose: Radiotherapy remains a major treatment method for malignant tumors. Magnetic resonance imaging (MRI) is the standard modality for assessing glioma treatment response in the clinic. Compared to MRI, ultrasound imaging is low-cost and portable and can be used during intraoperative procedures. The purpose of this study was to quantitatively compare contrast-enhanced ultrasound (CEUS) imaging and MRI of irradiated gliomas in rats and to determine which quantitative ultrasound imaging parameters can be used for the assessment of early response to radiation in glioma. Methods: Thirteen nude rats with U87 glioma were used. A small thinned skull window preparation was performed to facilitate ultrasound imaging and mimic intraoperative procedures. Both CEUS and MRI with structural, functional, and molecular imaging parameters were performed at preradiation and at 1 day and 4 days postradiation. Statistical analysis was performed to determine the correlations between MRI and CEUS parameters and the changes between pre- and postradiation imaging. Results: Area under the curve (AUC) in CEUS showed significant difference between preradiation and 4 days postradiation, along with four MRI parameters, T{sub 2}, apparent diffusion coefficient, cerebral blood flow, and amide proton transfer-weighted (APTw) (all p < 0.05). The APTw signal was correlated with three CEUS parameters, rise time (r = − 0.527, p < 0.05), time to peak (r = − 0.501, p < 0.05), and perfusion index (r = 458, p < 0.05). Cerebral blood flow was correlated with rise time (r = − 0.589, p < 0.01) and time to peak (r = − 0.543, p < 0.05). Conclusions: MRI can be used for the assessment of radiotherapy treatment response and CEUS with AUC as a new technique and can also be one of the assessment methods for early response to radiation in glioma.

60 APPLIED LIFE SCIENCES↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

SU-D-209-04: Raise Your Table: An Effective Way to Reduce Radiation Dose for Fluoroscopy

Purpose: Patient table height plays an important role in estimating patient skin dose for interventional radiology (IR) procedures, because the patient’s skin location is dependent on the height of table. Variation in table height can lead to as much as 150% difference in skin dose for patient exams with similar air kerma meter readings. In our facility, IR procedural workflow was recently changed to require the IR physicians to confirm the patient table height before the procedure. The patient table height data was collected before and after this workflow change to validate the implementation of this practice. Methods: Table height information was analyzed for all procedures performed in three IR rooms, which were impacted by the workflow change, covering three months before and after the change (Aug 2015 to Jan 2016). In total, 442, 425, and 390 procedures were performed in these three rooms over this time period. There were no personnel or procedure assignment changes during the six-month period of time. Statistical analysis was performed for the average table height changes before and after the workflow change. Results: For the three IR rooms investigated, after the workflow change, the average table heights were increased by 1.43 cm (p=0.004084), 0.66 cm (p=0.187089), and 1.59 cm (p=0.002193), providing a corresponding estimated skin dose savings of 6.76%, 2.94% and 7.62%, respectively. After the workflow change, the average table height was increased by 0.95 cm, 0.63 cm, 0.55 cm, 1.07 cm, 1.12 cm, and 3.36 cm for the six physicians who routinely work in these three rooms. Conclusion: Consistent improvement in table height settings has been observed for all IR rooms and all physicians following a simple workflow change. This change has led to significant patient dose savings by making physicians aware of the pre-procedure table position.

60 APPLIED LIFE SCIENCES↗

SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme

Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60 Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.

60 APPLIED LIFE SCIENCES↗

SU-F-T-675: Down-Regulating the Expression of Cdc42 and Inhibition of Migration of A549 with Combined Treatment of Ionizing Radiation and Sevoflurane

Purpose: Cdc42 is involved in cell transformation, proliferation, invasion and metastasis of human cancer cells. Cdc42 overexpression has been reported in several types of cancers. This study investigated the combined treatment effects of ionizing radiation and sevoflurane on down-regulating Cdc42 expression and suppressing migration of human adenocarcinoma cell line A549. Methods: Samples of A549 cells with Cdc42 overexpression were created and Cdc42 expression was determined by Western blotting. Increase of migration speed by Cdc42-HA overexpression was confirmed with an initial in-vitro scratch assay. The cells grown in culture media were separated into 2 groups of 6 samples: one for the control and the other was treated with 4% sevoflurane for 5hrs prior to a single-fraction radiation of 4Gy using a 6MV beam. Cell migration speeds of the 2 groups were measured with an initial in-vitro scratch assay. The scratch was created with a pipette tip immediately after treatment and images at 4 post-treatment time points (0h, 3h, 6h, 12h) were acquired. The distance between the two separated sides at 0h was used as reference and subsequent changes of the distance over time was defined as the cell migration speed. Image processing and measurement were performed with an in-house software. The experiment was repeated three times independently to evaluate the repeatability and reliability. Statistical analysis was performed with SPSS 19.0. Results: Western blotting showed the treatment down-regulated Cdc42 overexpression. Quantitative analysis and two-tailed t-test showed that cell migration speed of the treated group was higher than the control group at all time points after treatment (p < 0.02). Conclusion: Combined treatment of 6MV photon and sevoflurane can cause the effects of down-regulating Cdc42 overexpression and decrease of migration speed of A549 cells which provides potential of clinical benefit for the cancer therapy. More investigation is needed to further quantify the benefits of the combined therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

Purpose: The purpose of this study was to evaluate the interfractional and intrafractional motion of liver tumors in stereotactic body radiation therapy (SBRT), based on four-dimensional cone-beam computed tomography using fiducial markers. (4D-CBCT). Methods: Seven patients with liver tumors were treated by SBRT with abdominal compression (AC) in five fractions with image guidance based on 4D-CBCT. The 4D-CBCT studies were performed to determine the individualized internal margin for the planning simulation. The interfractional and intrafractional changes of liver tumor motion for all patients was measured, based on the planning simulation 4D-CBCT, pre-SBRT 4D-CBCT, and post-SBRT 4D-CBCT. The interfractional motion change was calculated from the difference in liver tumor amplitude on pre-SBRT 4D-CBCT relative to that of the planning simulation 4D-CBCT for each fraction. The intrafractional motion change was calculated from the difference between the liver tumor amplitudes of the pre- and post-SBRT 4D-CBCT for each fraction. Significant interfractional and intrafractional changes in liver tumor motion were defined as a change ≥3 mm. Statistical analysis was performed using the Pearson correlation. Results: The values of the mean amplitude of liver tumor, as indicated by planning simulation 4D-CBCT, were 1.6 ± 0.8 mm, 1.6 ± 0.9 mm, and 4.9 ± 2.2 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Pearson correlation coefficients between the liver tumor amplitudes, based on planning simulation 4D-CBCT, and pre-SBRT 4D-CBCT during fraction treatment in the LR, AP, and SI directions were 0.6, 0.7, and 0.8, respectively. Interfractional and intrafractional motion changes of ≥3 mm occurred in 23% and 3% of treatment fractions, respectively. Conclusion: The interfractional and intrafractional changes of liver tumor motion were small in most patients who received liver SBRT with AC. In addition, planning simulation 4D-CBCT was useful for representing liver tumor movement in patients undergoing SBRT. This work was supported by JSPS KAKENHI Grant Number 26861004.

60 APPLIED LIFE SCIENCES↗

TU-D-209-04: How Useful Are Indirect Dose Metrics for Estimating Peak Skin Dose in Interventional Cardiology?

Purpose: The purpose of this study was to determine if a relationship between indirect dose metrics and PSD could be established for fluoroscopically-guided interventional cardiology procedures. Methods: PSD were measured directly using XR-RV3 radiochromic film for 94 consecutive fluoroscopically guided interventional cardiology procedures performed at two sites. Procedures were both diagnostic and therapeutic in nature. Radiation dose structured reports (RDSR) were collected for each procedure and used to calculate indirect estimates of PSD which were compared to the measured PSD. Reference air kerma (Ka,r) was also compared to the measured PSD. Pearson’s correlation coefficient was calculated for each metric and metrics were compared to measured PSD using a two-tailed t-test. Data were log transformed prior to statistical analysis. Results: Both Ka,r and the calculated PSD were closely correlated with measured PSD at each sites (Ka,r: 0.92 and 0.86, indirect PSD: 0.91 and 0.88). At one site, neither Ka,r nor indirect PSD was significantly different from the measured PSD (p = 0.22 and p=0.054, respectively), while at the second site both Ka,r and indirect PSD were significantly higher than measured PSD (p<0.0001 and p<0.0001, respectively). In almost all cases, both Ka,r and indirect PSD overestimated the true PSD. Conclusions: The use of a range of gantry angles and table positions, along with variation in procedural imaging requirements, limits the utility of indirect dose metrics for predicting PSD for interventional cardiology procedures. A. Kyle Jones and Alexander S. Pasciak are owners of Fluoroscopic Safety, LLC.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

TH-C-204-00: Medical Physics Workshop: An Update On the Journal’s Improvement Activities and Guidance On Writing and Reviewing Papers

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-01: Vision for Medical Physics and Status of Current Initiatives

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗