Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Characterization of iron, manganese, and copper synthetic hydroxyapatites by electron paramagnetic resonance spectroscopy

The incorporation of micronutrients (e.g., Fe, Mn, Cu) into synthetic hydroxyapatite (SHA) is proposed for slow release of these nutrients to crops in NASA's Advanced Life Support (ALS) program for long-duration space missions. Separate Fe3+ (Fe-SHA), Mn2+ (Mn-SHA), and Cu2+ (Cu-SHA) containing SHA materials were synthesized by a precipitation method. Electron paramagnetic resonance (EPR) spectroscopy was used to determine the location of Fe3+, Mn2+, and Cu2+ ions in the SHA structure and to identify other Fe(3+)-, Mn(2+)-, and Cu(2+)-containing phases that formed during precipitation. The EPR parameters for Fe3+ (g=4.20 and 8.93) and for Mn2+ (g=2.01, A=9.4 mT, D=39.0 mT and E=10.5 mT) indicated that Fe3+ and Mn2+ possessed rhombic ion crystal fields within the SHA structure. The Cu2+ EPR parameters (g(z)=2.488, A(z)=5.2 mT) indicated that Cu2+ was coordinated to more than six oxygens. The rhombic environments of Fe3+ and Mn2+ along with the unique Cu2+ environment suggested that these metals substituted for the 7 or 9 coordinate Ca2+ in SHA. The EPR analyses also detected poorly crystalline metal oxyhydroxides or metal-phosphates associated with SHA. The Fe-, Mn-, and Cu-SHA materials are potential slow release sources of Fe, Mn, and Cu for ALS and terrestrial cropping systems.

NASA Center JSC↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

Eddy current correction in volume-localized MR spectroscopy

The quality of volume-localized magnetic resonance spectroscopy is affected by eddy currents caused by gradient switching. Eddy currents can be reduced with improved gradient systems; however, it has been suggested that the distortion due to eddy currents can be compensated for during postprocessing with a single-frequency reference signal. The authors propose modifying current techniques for acquiring the single-frequency reference signal by using relaxation weighting to reduce interference from components that cannot be eliminated by digital filtering alone. Additional sequences with T1 or T2 weighting for reference signal acquisition are shown to have the same eddy current characteristics as the original signal without relaxation weighting. The authors also studied a new eddy current correction method that does not require a single-frequency reference signal. This method uses two free induction decays (FIDs) collected from the same volume with two sequences with opposite gradients. Phase errors caused by eddy currents are opposite in these two FIDs and can be canceled completely by combining the FIDs. These methods were tested in a phantom. Eddy current distortions were corrected, allowing quantitative measurement of structures such as the -CH = CH- component, which is otherwise undetectable.

NASA Discipline Musculoskeletal↗

High-resolution spectroscopy of H2SO4, HDSO4, and D2SO4 vapor in the region 1200-10,000 cm(-1)

The high-resolution (0.05 cm(-1)) spectra of gas-phase H2SO4, HDSO4, and D2SO4 were measured over the frequency region 1200-10,000 cm(-1) using Fourier-transform infrared spectroscopy. The increased resolution of this work compared with previous studies has lead to an improved vibrational analysis of H2SO4. This study has answered unresolved questions about combination bands and overlapping features from previous gas-phase spectroscopic studies of H2SO4 and marks the first experimental measurement of the nu8 and nu15 torsional vibrations in this molecule. This work leads to a brief discussion on vibrational mode mixing in sulfuric acid.

Deuterium/chemistry↗

Biological imaging spectroscopy

Improved detectors, new electro-optical devices and vastly improved computational power for data analysis have fueled the recent interest in combining biology and spectroscopy.

biophotonics imaging spectroscopy↗

Compact Hererodyne 220 GHz Receiver For Planetary Spectroscopy

Solar System spectroscopy yields information about the physics, chemistry and dynamics of planetary atmospheres. Many molecular species, such as CO,water have very strong spectral emission lines in the millimeter and sumillimeter wave regions.

Compact Heterodyne Spectroscopy Solar System↗

The 1995 Atmospheric Trace Molecule Spectroscopy (ATMOS) Linelist

The Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment uses a Fourier transform spectrometer on board the space shuttle to record infrared solar occultation spectra of the atmosphere. Described are the current version of the molecular spectroscopic database used for the analysis of the data obtained during three Space Shuttle missions between 1992 and 1994.

molecular database↗

Excitation Spectroscopy as a Tool of Microelectronics Reliability

The main objective of this task was to experimentally determine the feasibility of using a non-contact IR emission spectroscopy technique to measure the hot spot channel temperature of sub-micron GaAs metal semiconductor field effect transistor gate during operation.

Excitation Spectroscopy Microspot Temperature Asse↗

Ballistics-Electron-Microscopy and Spectroscopy of Metal/GaN Interfaces

BEEM spectroscopy and imaging have been applied to the Au/GaN interface. In contrast to previous BEEM measurements, spectra yield a Schottky barrier height of 1.04eV that agrees well with the highest values measured by conventional methods.

ballistic-electron-emission microscopy spectroscop↗

Planar diode multiplier chains for THz spectroscopy

High-resolution laboratory spectroscopy is utilized as a diagnostic tool to determine noise and harmonic content of balanced [9]-[11] and unbalanced [12]-[14] multiplier designs. Balanced multiplier designs suppress unintended harmonics more than -20dB. Much smaller values were measured on unbalanced multipliers.

high-resolution spectroscopy↗