Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A comparison of pulsed and continuous lasers for high-temperature Raman measurements of anhydrite

Oxygen carrier particles (OCPs) serve as fuel oxidant in emerging chemical looping combustion systems. However, chemical looping combustion process optimization is hindered by the lack of online sensors for measurements of OCP oxidation states at temperatures up to 1,000 °C and pressures up to 10 atm. We are investigating Raman spectroscopy as a potential solution, as this technique is known for its ability to provide noninvasive, molecularly specific information in real time in a wide variety of applications. As a case study, Raman spectra from high–temperature (>1,000 °C) anhydrite, a potential OCP, are presented using pulsed and continuous wave excitation at 532 nm. When pulsed excitation is coupled with time–gated detection, background signal from thermal radiation can be significantly reduced from single pulse spectra, outperforming results using an ungated detector. Also, laser heating of the sample is not observed but laser–induced breakdown spectra increasingly appear with increasing temperature and pulse intensity. Compared with pulsed excitation, continuous wave excitation with longer acquisition time, offers higher signal to noise and avoids the risk for laser–induced breakdown spectra but demonstrates minor sample heating. Finally, the data demonstrate practical utility by (a) providing a calibration of anhydrite's ν 1 (1,017 cm –1 ) Raman temperature–dependent band position and by (b) providing estimates of temperature using the ratios of the Stokes/anti–Stokes ν 1 integrated intensities. Furthermore, these results demonstrate the first high–temperature, pulsed Raman spectra from anhydrite while evaluating challenges associated with high–temperature, Raman measurements of OCP materials in general.

20 FOSSIL-FUELED POWER PLANTS↗

Displaced lepton jet signatures from self-interacting dark matter bound states

We study self-interacting dark matter signatures at the Large Hadron Collider. A light dark photon, mediating dark matter self-interactions, can bind dark matter particles to form a bound state when they are produced via a heavy pseduoscalar in pp collisions. The bound state can further annihilate into a pair of boosted dark photons, which subsequently decay into charged leptons through a kinetic mixing portal, resulting in striking displaced lepton jet signals. After adapting the analysis used in the ATLAS experiment, we explore the reach of the model parameters at the 13 TeV run with an integrated luminosity of 300 fb -1 . For heavy dark matter, the displaced lepton jet searches can surpass traditional monojet signals in setting the lower bound on the pseduoscalar mass. If a positive signal is detected, we can probe the dark matter mass and the dark coupling constant after combining both the displaced lepton jet and monojet searches. We further show the CMS dimuon search can be sensitive to the final state radiation of the dark photon. Our results demonstrate terrestrial collider experiments complement astronomical observations of galaxies in the search of the self-interacting nature of dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

Expression of cellular apoptosis susceptibility (CAS) in the human testis and testicular germ cell tumors

Testicular germ cell tumors are the most frequent malignancies found in men between 15 and 44 years old. Although cellular apoptosis susceptibility (CAS) was demonstrated to be upregulated in breast cancer and colon cancer, the expression of CAS in the human testis and testicular germ cell tumors remained elusive. In the present study, CAS-positive signals were detected in the normal testicular tissues, cancer adjacent normal testicular tissues, seminoma, yolk sac tumor, and teratoma. Interestingly, the expression level of CAS in testicular germ cell tumors (TGCTs) (but not seminoma) was significantly lower than that of human testicular tissues and cancer adjacent normal testicular tissues, suggesting that decreased CAS contributed to the progression of TGCTs. Notably, the expression of CAS in seminoma was significantly higher than that of in the non-seminomas, consistent with the results from TCGA database. Furthermore, the localization of CAS is mainly restricted in the nucleus in the lesions of normal human testicular tissue and cancer adjacent normal testicular tissue. Although the expression of CAS was not significantly different between normal testicular tissue and seminoma, CAS was more enriched in cytoplasm in seminoma compared to the normal, cancer adjacent tissue and other types of TGCTs. The current results demonstrated reduced expression of CAS in the human testicular germ cell tumors and the CAS translocation from the nuclear to cytoplasm in seminoma, thereby supporting a possible role in normal testis function and in the development of seminoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear spectroscopy for in situ soil elemental analysis: Monte Carlo simulations

We developed a model to simulate a novel inelastic neutron scattering (INS) system for in situ non-destructive analysis of soil using standard Monte Carlo Neutron Photon (MCNP5a) transport code. The volumes from which 90%, 95%, and 99% of the total signal are detected were estimated to be 0.23 m{sup 3}, 0.37 m{sup 3}, and 0.79 m{sup 3}, respectively. Similarly, we assessed the instrument's sampling footprint and depths. In addition we discuss the impact of the carbon's depth distribution on sampled depth.

54 ENVIRONMENTAL SCIENCES↗

Single-molecule imaging at high fluorophore concentrations by local activation of dye

Single-molecule fluorescence microscopy is a powerful approach to observe biomolecular interactions with high spatial and temporal resolution. Detecting fluorescent signals from individual, labeled proteins above high levels of background fluorescence remains challenging, however. For this reason, the concentrations of labeled proteins in in vitro assays are often kept low compared to their in vivo concentrations. Here, we present a new fluorescence imaging technique by which single fluorescent molecules can be observed in real time at high, physiologically relevant concentrations. The technique requires a protein and its macromolecular substrate to be labeled each with a different fluorophore. Then, making use of short-distance energy-transfer mechanisms, the fluorescence from only those proteins bound to their substrate are selectively activated. This approach is demonstrated by labeling a DNA substrate with an intercalating stain, exciting the stain, and using energy transfer from the stain to activate the fluorescence of only those labeled DNA-binding proteins bound to the DNA. Such an experimental design allowed us to observe the sequence-independent interaction of Cy5-labeled interferon-inducible protein 16 (IFI16) with DNA and the sliding via one-dimensional diffusion of Cy5-labeled adenovirus protease (pVIc-AVP) on DNA in the presence of a background of hundreds of nM Cy5 fluorophore.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity of geophysical techniques for monitoring secondary CO 2 storage plumes

For geologic carbon storage, the ability to detect secondary CO 2 plumes—defined as those CO 2 plumes accumulating outside the intended storage reservoir—is fundamental to preventing unexpected CO 2 migration into groundwater resources and for risk and liability management. Understanding the sensitivity of various geophysical methods to secondary plumes is crucial for designing cost-effective monitoring schemes. We use several modeling scenarios to demonstrate the process of assessing sensitivities and detection thresholds of three primary geophysical techniques—surface seismic, borehole-to-surface electromagnetic (EM), and surface and borehole gravity—for early detection of secondary CO 2 plumes in the post-injection phase. While seismic reflection methods are often considered in monitoring strategies to track the evolution of CO 2 plumes, they are also the most expensive. Due to cost considerations, especially for long-term post-injection monitoring, other techniques complement seismic monitoring when designing an adaptive monitoring network. Borehole-to-surface EM or surface gravity surveys are feasible for time-lapse monitoring of deep secondary CO 2 plumes. Furthermore, these surveys could be carried at intervals defined by site-specific conditions. If time-lapse EM and/or gravity surveys detect any signal responses beyond the expected change, it would trigger a need for the higher resolution seismic survey.

58 GEOSCIENCES↗

Structural Characterization of the Predominant Family of Histidine Kinase Sensor Domains

Histidine kinase (HK) receptors are used ubiquitously by bacteria to monitor environmental changes, and they are also prevalent in plants, fungi, and other protists. Typical HK receptors have an extracellular sensor portion that detects a signal, usually a chemical ligand, and an intracellular transmitter portion that includes both the kinase domain itself and the site for histidine phosphorylation. While kinase domains are highly conserved, sensor domains are diverse. HK receptors function as dimers, but the molecular mechanism for signal transduction across cell membranes remains obscure. In this study, eight crystal structures were determined from five sensor domains representative of the most populated family, family HK1, found in a bioinformatic analysis of predicted sensor domains from transmembrane HKs. Each structure contains an inserted repeat of PhoQ/DcuS/CitA (PDC) domains, and similarity between sequence and structure is correlated across these and other double-PDC sensor proteins. Three of the five sensors crystallize as dimers that appear to be physiologically relevant, and comparisons between ligated structures and apo-state structures provide insights into signal transmission. Some HK1 family proteins prove to be sensors for chemotaxis proteins or diguanylate cyclase receptors, implying a combinatorial molecular evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical and morphological studies of ionic polymer metal composites as stress sensors

Ionic polymer metal composites (IPMCs) are the backbone of a wide range of ionic devices. IPMC mechanoelectric sensors are advanced nanostructured transducers capable of converting mechanical strain into easily detectable electric signal. Such attribute is realized by ion mobilization in and through IPMC nanostructure. In this study we have investigated electrochemical and morphological characteristics of IPMCs by varying the morphology of their metal composite component (conductive network composite (CNC)). We have demonstrated the dependence of electrochemical properties on CNC nanostructure as well as mechanoelectrical performance of IPMC sensors as a function of CNC morphology. Lastly, it is shown that the morphology of CNC can be used as a means to improve sensitivity of IPMC sensors by 3–4 folds.

36 MATERIALS SCIENCE↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tungsten erosion during L-mode discharges in the DIII-D SAS-VW divertor

A series of L-mode plasma discharges was performed in the DIII-D tokamak to assess the impact of outer strike point (OSP) position and toroidal magnetic field direction on erosion and core contamination potential of the recently-installed, tungsten-coated Small Angle Slot (SAS-VW) divertor. In one discharge, in-slot emission spectroscopy measured an<48 % increase in the W gross erosion rate when the OSP was moved 3 cm outwards, away from the V-shaped vertex of the slot divertor. However, the effective W yield (erosion rate divided by the incident D flux) was, overall, insensitive to changes in OSP location. Consistently low estimates of the effective W yield based on measurements taken a few cm outwards from the vertex suggest potentially significant C surface contamination. No W emission signal was detected when orienting the toroidal magnetic field such that the ion B×∇B drift direction is pointed away from the X-point. However, measurements of W content in the plasma core for both toroidal magnetic field directions suggest the presence of additional, unmeasured sources of erosion. The difference in the measured core W density with OSP position is much greater than the difference in the measured erosion rates, which may suggest that the leakage of eroded impurities out of the divertor is governed primarily through the parallel ion temperature gradient and friction forces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core-collapse supernova explosion simulations

Neutrinos play important roles in the pre-collapse evolution, explosion, and aftermath of core-collapse supernovae. Detected neutrino signals from core-collapse supernovae would provide insight into the explosion mechanism and unknown neutrino mixing parameters. Achieving these goals requires large-scale, multiphysics simulations. For many years, several groups have performed such simulations with increasing realism. Current simulations and plans for future work of the Oak Ridge group are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supernova Modeling: Progress and Challenges

Neutrinos play important roles in the pre-collapse evolution, explosion, and aftermath of core-collapse supernovae. Detected neutrino signals from core-collapse supernovae would provide insight into the explosion mechanism and unknown neutrino mixing parameters. Achieving these goals requires large-scale, multiphysics simulations. For many years, several groups have performed such simulations with increasing realism. Current simulations and plans for future work of the Oak Ridge group are described.

Cardall, Christian Y↗

Reflections on the anomalous ANITA events: the Antarctic subsurface as a possible explanation

The Antarctic Impulsive Transient Antenna (ANITA) balloon experiment was designed to detect radio signals initiated by high-energy neutrinos and cosmic ray (CR) air showers. These signals are typically discriminated by the polarization and phase inversions of the radio signal. The reflected signal from CRs suffer phase inversion compared to a direct ‘tau neutrino’ event. In this paper, we study subsurface reflection, which can occur without phase inversion, in the context of the two anomalous up-going events reported by ANITA. It is found that subsurface layers and firn density inversions may plausibly account for the events, while ice fabric layers and wind ablation crusts could also play a role. This hypothesis can be tested with radar surveying of the Antarctic region in the vicinity of the anomalous ANITA events. Future experiments should not use phase inversion as a sole criterion to discriminate between down-going and up-going events, unless the subsurface reflection properties are well understood.

54 ENVIRONMENTAL SCIENCES↗

Lactate Racemase Nickel-Pincer Cofactor Operates by a Proton-Coupled Hydride Transfer Mechanism

Lactate racemase (LarA) of Lactobacillus plantarum contains a novel organometallic cofactor with nickel coordinated to a covalently tethered pincer ligand, pyridinium-3-thioamide-5-thiocarboxylic acid mononucleotide, but its function in the enzyme mechanism has not been elucidated. This study presents direct evidence that the nickel-pincer cofactor facilitates a proton-coupled hydride transfer (PCHT) mechanism during LarA-catalyzed lactate racemization. No signal was detected by electron paramagnetic resonance spectroscopy for LarA in the absence or presence of substrate, consistent with a +2 metal oxidation state and inconsistent with a previously proposed proton-coupled electron transfer mechanism. Pyruvate, the predicted intermediate for a PCHT mechanism, was observed in quenched solutions of LarA. A normal substrate kinetic isotope effect (k H /k D of 3.11 ± 0.17) was established using 2-α- 2 H-lactate, further supporting a PCHT mechanism. UV–visible spectroscopy revealed a lactate-induced perturbation of the cofactor spectrum, notably increasing the absorbance at 340 nm, and demonstrated an interaction of the cofactor with the inhibitor sulfite. Here, a crystal structure of LarA provided greater resolution (2.4 Å) than previously reported and revealed sulfite binding to the pyridinium C4 atom of the reduced pincer cofactor, mimicking hydride reduction during a PCHT catalytic cycle. Finally, computational modeling supports hydride transfer to the cofactor at the C4 position or to the nickel atom, but with formation of a nickel-hydride species requiring dissociation of the His200 metal ligand. In aggregate, these studies provide compelling evidence that the nickel-pincer cofactor acts by a PCHT mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Learning the Low Frequency Earthquake Activity on the Central San Andreas Fault

Abstract Low frequency earthquakes (LFEs) originating below the central San Andreas Fault are associated with slow‐slip beneath the seismogenic zone within the more ductile portion of the crust. Monitoring efforts over 15 years detected >1 million LFEs. We train a gradient boosted tree model using statistical features describing the seismic waveforms to estimate the hourly LFE event count. The burst‐like LFE behavior is reproduced, while lower amplitudes are predicted during the most active periods. The hourly event counts are up to 18% greater than the catalog. The ability to continuously monitor LFE activity provides insight to when geodetic measurements of slow slip are possible, without the need for developing a computational‐intensive template‐matching catalog. Similar waveform statistical features are found between detecting LFEs and tremors, which provides additional evidence tremors are composed of LFEs. The approach extracts information contained in continuous seismic waveforms that might benefit detecting precursory signals.

58 GEOSCIENCES↗

Ultrasensitive photodetectors exploiting electrostatic trapping and percolation transport

The sensitivity of semiconductor photodetectors is limited by photocarrier recombination during the carrier transport process. We developed a new photoactive material that reduces recombination by physically separating hole and electron charge carriers. This material has a specific detectivity (the ability to detect small signals) of 5 × 10 17 Jones, the highest reported in visible and infrared detectors at room temperature, and 4-5 orders of magnitude higher than that of commercial single-crystal silicon detectors. The material was fabricated by sintering chloride-capped CdTe nanocrystals into polycrystalline films, where Cl selectively segregates into grain boundaries acting as n-type dopants. Photogenerated electrons concentrate in and percolate along the grain boundaries - a network of energy valleys, while holes are confined in the grain interiors. This electrostatic field-assisted carrier separation and percolation mechanism enables an unprecedented photoconductive gain of 10 10 e - per photon, and allows for effective control of the device response speed by active carrier quenching.

36 MATERIALS SCIENCE↗