Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Moisture content and gas sampling device

An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.

Krieg, H. C., Jr.↗

A medium-bright quasar sample - New quasar surface densities in the magnitude range from 16.4 to 17.65 for B

A new medium-bright quasar sample (MBQS) is constructed from spectroscopic observations of 140 bright objects selected for varying degrees of blue and ultraviolet excess (B-UVX) in five Palomar 1.2 m Schmidt fields. The MBQS contains 32 quasars with B less than 17.65 mag. The new integral surface densities in the B range from 16.45 to 17.65 mag are approximately 40 percent (or more) higher than expected. The MBQS and its redshift distribution increase the area of the Hubble diagram covered by complete samples of quasars. The general spectroscopic results indicate that the three-color classification process used to catalog the spectroscopic candidates (1) has efficiently separated the intrinsically B-UVX stellar objects from the Population II subdwarfs and (2) has produced samples of B-UVX objects which are more complete than samples selected by (U - B) color alone.

Mitchell, K. J.↗

Acoustic Translation of an Acoustically Levitated Sample

Acoustic-levitation apparatus uses only one acoustic mode to move sample from one region of chamber to another. Sample heated and cooled quickly by translation between hot and cold regions of levitation chamber. Levitated sample is raised into furnace region by raising plunger. Frequency of sound produced by transducers adjusted by feedback system to maintain (102) resonant mode, which levitates sample midway between transducers and plunger regardless of plunger position.

Barmatz, M. B.↗

Planetary sample rapid recovery and handling

Methods for recovering and cost effectively handling planetary samples following return to the vicinity of Earth were designed for planetary mission planners. Three topics are addressed: (1) a rough cost estimate was produced for each of a series of options for the handling of planetary samples following their return to the vicinity of Earth; (2) the difficulty of quickly retrieving planetary samples from low circular and high elliptical Earth orbit is assessed; and (3) a conceptual design for a biological isolation and thermal control system for the returned sample and spacecraft is developed.

Source record↗

Samples at the Apollo 15 landing site: Types and distribution

Samples, consisting of more than 350 individually numbered samples of rock and regolith, were collected during the three EVAs on the Apollo 15 mission. Samples consisted of rock specimens, and scooped, trenched, and cored regolith samples. Petrographic and chemical analysis are discussed.

Ryder, G.↗

The stability of a sample in a diamond anvil cell

A theoretical analysis of the stability of a gasketed sample in a diamond anvil cell is reported, demonstrating that the stability of the sample depends principally on the yield strength and the thickness of the gasket, the bulk modulus and the radius of the sample, and the geometry of the culet. The results yield a simple methodology that can be used to obtain stable samples in a diamond anvil cell.

Moss, William C.↗

Shock effects and argon loss in samples of the Leedey L6 chondrite experimentally shocked to 29-70 GPa pressures

The recovery of polished 600-micron-thick 7-mm-diameter disk samples and powder samples of the Leedey L6 chondrite from 29-70-GPa experimental shocks is investigated experimentally under vacuum conditions, with a focus on the possible direct shock loss of radiogenic Ar. The results of petrographic examination of the shocked samples and Ar isotope measurements are presented in tables, graphs, and micrographs and characterized in detail. The principal damage mechanisms are identified as mechanical disaggregation and increasing cataclasis, with little melting. The degassing of radiogenic Ar is found to be relatively modest and to increase with shock pressure and sample porosity; it is attributed to a combination of mechanical grain disruption and feldspar melting. It is inferred that Ar loss in naturally shocked materials (especially those showing few signs of melting) probably occurs during extended exposure to high temperatures during impact formation.

Bogard, Donald↗

Mineralogical studies of sulfide samples and volatile concentrations of basalt glasses from the southern Juan de Fuca Ridge

Sulfide samples obtained from Alvin dives on the southern Juan de Fuca Ridge were examined, showing the presence of two previously undiscovered minerals, both formed at low temperatures. The first detection of lizardite, starkeyite, and anatase in such an environment is also reported. Sulfide geothermometry involving the Cu-Fe-S system shows a vent temperature of less than 328 C for one sample. Ice-melting temperatures on inclusions from this sample are about -2.8 C, and fluid inclusion studies on crystals near this sample show pressure-corrected homogenization temperatures of 268 and 285 C. Volatile concentrations from vesicle-free basalt glass from the vent field are found to be about 0.0013 wt pct CO2 and 0.16 wt pct H2O.

Brett, Robin↗

A model study of potential sampling errors due to data scatter around expendable bathythermograph transects in the tropical Pacific

A linear multiple vertical-mode model described by McPhaden et al. (1988) is used to examine potential errors due to data scatter around expendable bathythermograph (XBT) transects in the tropical Pacific. Two methods of sampling are compared. In the first, the model was sampled along approximately straight lines of grid points corresponding to the mean positions of XBT tracks in the eastern, central, and western Pacific; in the second, the model was sampled again at the dates and locations of actual XTB casts for 1979-1983. The model indicates that the data scattered zonally around XBT transects in general can lead to about 2 dyn cm error in dynamic height in composite sections of XBT data. Errors larger than 2 dyn cm occurred in regions where XBT sample spacing in the zonal direction was insufficient to resolve Rossby wave variations in the model.

Mcphaden, Michael J.↗

Fluid inclusions in Martian samples: Clues to early crustal development and the hydrosphere

Major questions about Mars that could be illuminated by examining fluid inclusions in Martian samples include: (1) the nature, extent and timing of development (and decline) of the hydrosphere that existed on the planet; and (2) the evolution of the crust. Fluid inclusion analyses of appropriate samples could provide critical data to use in comparison with data derived from analogous terrestrial studies. For this study, sample handling and return restrictions are unlikely to be as restrictive as the needs of other investigators. The main constraint is that the samples not be subjected to excessively high temperatures. An aqueous fluid inclusion trapped at elevated pressure and temperature will commonly consist of liquid water and water vapor at room temperature. Heating (such as is done in the laboratory to fix P-V-T data for the inclusion) results in moderate pressure increases up to the liquid-vapor homogenization temperature followed by a sharp increase in pressure with continued heating because the inclusion is effectively a fixed volume system. This increased pressure can rupture the inclusion; precise limits are dependent on size, shape, and composition as well as the host material.

Brown, Philip E.↗

Mars sampling strategy and aeolian processes

It is critical that the geological context of planetary samples (both in situ analyses and return samples) be well known and documented. Apollo experience showed that this goal is often difficult to achieve even for a planet on which surficial processes are relatively restricted. On Mars, the variety of present and past surface processes is much greater than on the Moon and establishing the geological context of samples will be much more difficult. In addition to impact hardening, Mars has been modified by running water, periglacial activity, wind, and other processes, all of which have the potential for profoundly affecting the geological integrity of potential samples. Aeolian, or wind, processes are ubiquitous on Mars. In the absence of liquid water on the surface, aeolian activity dominates the present surface as documented by frequent dust storms (both local and global), landforms such as dunes, and variable features, i.e., albedo patterns which change their size, shape, and position with time in response to the wind.

Greeley, Ronald↗

Deciphering Martian climatic history using returned samples

By necessity, a Mars sample return mission must sample the upper few meters of the Martian surface. This material was subjected to a wide variety of physical processes. Presently, the most important processes are believed to be wind-driven erosion and deposition, and water ice accumulation at higher latitudes. A sample return mission represents an opportunity to better understand and quantify these important geological processes. By obtaining sample cores at key locations, it may be possible to interpret much of recent Martian climatic history.

Paige, D. A.↗

Martian sample sites: Examples based on a global geologic perspective

Ten areas were selected that each include several rock units of varying lithology and age. These areas were chosen to optimize the geologic and chronologic data return from Mars. Geologic mapping and stratigraphic studies identify stratigraphic ages, rock types, and information on Martian geologic history that samples of a given site may yield. Volcanic rocks occur over much of the planet and in virtually all stratigraphic positions, and they are amenable to radioisotopic dating. Therefore, a reasonable and essential goal for a sample return mission is to return datable rocks from widely varying strata. Generally, about three or four major geologic units can be sampled at any of the given sites, most of which can probably be dated. The Mars Observer mission will aid greatly in interpreting lithology and defining contacts at the high resolution required to actually pinpoint good sample acquisition sites within these areas.

Scott, D. H.↗

U-Th-Pb, Sm-Nd, Rb-Sr, and Lu-Hf systematics of returned Mars samples

The advantage of studying returned planetary samples cannot be overstated. A wider range of analytical techniques with higher sensitivities and accuracies can be applied to returned samples. Measurement of U-Th-Pb, Sm-Nd, Rb-Sr, and Lu-Hf isotopic systematics for chronology and isotopic tracer studies of planetary specimens cannot be done in situ with desirable precision. Returned Mars samples will be examined using all the physical, chemical, and geologic methods necessary to gain information on the origin and evolution of Mars. A returned Martian sample would provide ample information regarding the accretionary and evolutionary history of the Martian planetary body and possibly other planets of our solar system.

Tatsumoto, M.↗

Mineralogical and geochemical anomalous data of the K-T boundary samples

Cretaceous-Tertiary boundary problem has been discussed previously from the geological research, mainly by fossil changes. Although geochemical bulk data of Ir anomaly suggest the extraterrestrial origin of the K-T boundary, the exact formation process discussed mainly by mineralogical and geochemical study has been started recently, together with noble gas contents. The K-T boundary sample at Kawaruppu River, Hokkaido was collected, in order to compare with the typical K-T boundary samples of Bubbio, Italy, Stevns Klint, Denmark, and El Kef, Tunisia. The experimental data of the silicas and calcites in these K-T boundary samples were obtained from the X-ray unit-cell dimension (i.e., density), ESR signal and total linear absorption coefficient, as well as He and Ne contents. The K-T boundary samples are usually complex mixture of the terrestrial activities after the K-T boundary event. The mineralogical and geochemical anomalous data indicate special terrestrial atmosphere at the K-T boundary formation probably induced by asteroid impact, followed the many various terrestrial activities (especially the strong role of sea-water mixture, compared with terrestrial highland impact and impact craters in the other earth-type planetary bodies).

Miura, Y.↗

A core handling device for the Mars Sample Return Mission

A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.

Gwynne, Owen↗

Effect of control sampling rates on model-based manipulator control schemes

The effect of changing the control sampling period on the performance of the computed-torque and independent joint control schemes is discussed. While the former utilizes the complete dynamics model of the manipulator, the latter assumes a decoupled and linear model of the manipulator dynamics. Researchers discuss the design of controller gains for both the computed-torque and the independent joint control schemes and establish a framework for comparing their trajectory tracking performance. Experiments show that within each scheme the trajectory tracking accuracy varies slightly with the change of the sampling rate. However, at low sampling rates the computed-torque scheme outperforms the independent joint control scheme. Based on experimental results, researchers also conclusively establish the importance of high sampling rates as they result in an increased stiffness of the system.

Khosla, P. K.↗

Study of sampling systems for comets and Mars

Several aspects of the techniques that can be applied to acquisition and preservation of samples from Mars and a cometary nucleus were examined. Scientific approaches to sampling, grounded in proven engineering methods are the key to achieving the maximum science value from the sample return mission. If development of these approaches for collecting and preserving does not preceed mission definition, it is likely that only suboptimal techniques will be available because of the constraints of formal schedule timelines and the normal pressure to select only the most conservative and least sophisticated approaches when development has lagged the mission milestones. With a reasonable investment now, before the final mission definition, the sampling approach can become highly developed, ready for implementation, and mature enough to help set the requirements for the mission hardware and its performance.

Amundsen, R. J.↗