Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Digital signal processing for the ATLAS/LUCID detector

Both the detector and the associated read-out electronics have been improved in order to cope with the LHC luminosity increase foreseen for RUN 2 and RUN 3. The new operating conditions require a careful tuning of the read-out electronics in order to optimize the signal-to-noise ratio. The new read-out electronics will allow the use of digital filtering of the photo multiplier tube signals. In this talk, we will present the first results that we obtained in the optimization of the signal-to-noise ratio. In addition, we will introduce the next steps to adapt this system to high performance read-out chains for low energy gamma rays. Such systems are based, for instance, on Silicon Drift Detector devices and can be used in applications at Free-Electron-Laser facilities such as the XFEL under construction at DESY. (authors)

43 PARTICLE ACCELERATORS↗

Passive mode locking of a GaSb-based quantum well diode laser emitting at 2.1 μm

We demonstrate passive mode locking of a GaSb-based diode laser emitting at 2.1 μm. The active region of the studied device consists in two 10-nm-thick GaInSbAs/GaAlSbAs quantum wells. Passive mode locking has been achieved in a two-section laser with one of the sections used as a saturable absorber. A microwave signal at 20.6 GHz, measured in the electrical circuit of the absorber, corresponds to the fundamental photon round-trip frequency in the laser resonator. The linewidth of this signal as low as ∼10 kHz has been observed at certain operating conditions, indicating low phase noise mode-locked operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phosphor Thermometry Signal Analysis and Interpretation

Since the last International Temperature Symposium, phosphor thermometry has continued to mature with considerable attention given to combustion and turbine engine applications. More recently the utility to problems on the micro- and nano-scales has appreciated, particularly in regard to biological and biomedical situations. The method is therefore used for a wide range of situations. Signal interpretation is important and experience teaches that without sufficient care phosphor signals can be misleading. In order to advance the method, signal analysis investigations should prove fruitful. The specific aspect addressed here is the question of waveform sampling. A simple phenomenological approach is described that explores how the number of points digitized per waveform affects the measurement repeatability and accuracy. This is demonstrated for single shot signals and the average of 512 sequential waveforms. A bright temperature-independent luminescence signal from YVO4:Eu is sampled every 800 ps for a highly sampled condition and every 8 microseconds for a low sampled condition. When the average of 512 waveforms are compared for the two sampling conditions, they differ by only 0.4%. For the highly sampled case, a noisy single shot waveform compared to the averaged waveform differed by 1.8%. Future efforts on this subject will address intermediate and lower sampling rates. Also, variable window techniques should be explored that are especially important for non-log-linear signals. Investigations, such as this, give the developer the requisite information for designing analysis systems appropriate for the intended application in terms of precision, accuracy, and response time.

Fluorescence thermometry↗

Signal transduction pathways and transcription factors triggered by arsenic trioxide in leukemia cells

Arsenic trioxide (As{sub 2}O{sub 3}) is widely used to treat acute promyelocytic leukemia (APL). Several lines of evidence have indicated that As{sub 2}O{sub 3} affects signal transduction and transactivation of transcription factors, resulting in the stimulation of apoptosis in leukemia cells, because some transcription factors are reported to associate with the redox condition of the cells, and arsenicals cause oxidative stress. Thus, the disturbance and activation of the cellular signaling pathway and transcription factors due to reactive oxygen species (ROS) generation during arsenic exposure may explain the ability of As{sub 2}O{sub 3} to induce a complete remission in relapsed APL patients. In this report, we review recent findings on ROS generation and alterations in signal transduction and in transactivation of transcription factors during As{sub 2}O{sub 3} exposure in leukemia cells.

60 APPLIED LIFE SCIENCES↗

An Evaluation of Dynamical Downscaling Methods Used to Project Regional Climate Change

In the past decade, dynamical downscaling using “pseudo-global-warming” (PGW) techniques has been applied frequently to project regional climate change. Such techniques generate signals by adding mean global climate model (GCM)-simulated climate change signals in temperature, moisture, and circulation to lateral and surface boundary conditions derived from reanalysis. An alternative to PGW is to downscale GCM data directly. This technique should be advantageous, especially for simulation of extremes, since it incorporates the GCM's full spectrum of changing synoptic-scale dynamics in the regional solution. Here, we test this assumption, by comparing simulations in Europe and Western North America. We find that for warming and changes in temperature extremes, PGW often produces similar results to direct downscaling in both regions. For mean and extreme precipitation changes, PGW generally also performs surprisingly well in many cases. Moisture budget analysis in the Western North America domain reveals why. Large fractions of the downscaled hydroclimate changes arise from mean changes in large-scale thermodynamics and circulation, that is, increases in temperature, moisture, and winds, included in PGW by design. The one component PGW may have difficulty with is the contribution from changes in synoptic-scale variability. When this component is large, PGW performance could be degraded. Global analysis of GCM data shows there are regions where it is large or dominant. Hence, our results provide a road map to identify, through GCM analyses, the circumstances when PGW would not be expected to accurately regionalize GCM climate signals.

54 ENVIRONMENTAL SCIENCES↗

Empirical Mode Decomposition Technique with Conditional Mutual Information for Denoising Operational Sensor Data

A new approach is developed for denoising signals using the Empirical Mode Decomposition (EMD) technique and the Information-theoretic method. The EMD technique is applied to decompose a noisy sensor signal into the so-called intrinsic mode functions (IMFs). These functions are of the same length and in the same time domain as the original signal. Therefore, the EMD technique preserves varying frequency in time. Assuming the given signal is corrupted by high-frequency Gaussian noise implies that most of the noise should be captured by the first few modes. Therefore, our proposition is to separate the modes into high-frequency and low-frequency groups. We applied an information-theoretic method, namely mutual information, to determine the cut-off for separating the modes. A denoising procedure is applied only to the high-frequency group using a shrinkage approach. Upon denoising, this group is combined with the original low-frequency group to obtain the overall denoised signal. We illustrate our approach with simulated and real-world data sets. The results are compared to two popular denoising techniques in the literature, namely discrete Fourier transform (DFT) and discrete wavelet transform (DWT). We found that our approach performs better than DWT and DFT in most cases, and comparatively to DWT in some cases in terms of: (i) mean square error, (ii) recomputed signal-to-noise ratio, and (iii) visual quality of the denoised signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus for monitoring the condition of mining machinery transmissions

A portable apparatus is reported for measuring vibro-acoustic signals of mining machine transmissions for analysis of vibration levels and for damage detection. An automatic recording device connected to the detection channels permits measurments of the overall level of vibroacceleration as well as of the level in octave bands.

Levites, I. A.↗

The effect of irradiation and reflectance variability on vegetation condition assessment

Surface reflectance and global irradiance variations across an imaged area determine the minimum signal difference from groups of pixels in different targets needed to discriminate them. The factors affecting such variations and their magnitudes are considered. The sensor output also depends upon the interaction of the spectral response of the sensor and the spectral upwelling radiance from the target. From a consideration of the spectral instrument responses of detectors in the Landsat multispectral scanners (MS), together with measured reflectance factors of a vegetative canopy stressed to different levels of severity, the feasibility of mapping and quantifying disease stress witlh Landsat vegetative indices (VINs) is demonstrated.

Duggin, M. J.↗

Design and Flight Tests of an Adaptive Control System Employing Normal-Acceleration Command

An adaptive control system employing normal-acceleration command has been designed with the aid of an analog computer and has been flight tested. The design of the system was based on the concept of using a mathematical model in combination with a high gain and a limiter. The study was undertaken to investigate the application of a system of this type to the task of maintaining nearly constant dynamic longitudinal response of a piloted airplane over the flight envelope without relying on air data measurements for gain adjustment. The range of flight conditions investigated was between Mach numbers of 0.36 and 1.15 and altitudes of 10,000 and 40,000 feet. The final adaptive system configuration was derived from analog computer tests, in which the physical airplane control system and much of the control circuitry were included in the loop. The method employed to generate the feedback signals resulted in a model whose characteristics varied somewhat with changes in flight condition. Flight results showed that the system limited the variation in longitudinal natural frequency of the adaptive airplane to about half that of the basic airplane and that, for the subsonic cases, the damping ratio was maintained between 0.56 and 0.69. The system also automatically compensated for the transonic trim change. Objectionable features of the system were an exaggerated sensitivity of pitch attitude to gust disturbances, abnormally large pitch attitude response for a given pilot input at low speeds, and an initial delay in normal-acceleration response to pilot control at all flight conditions. The adaptive system chatter of +/-0.05 to +/-0.10 of elevon at about 9 cycles per second (resulting in a maximum airplane normal-acceleration response of from +/-0.025 g to +/- 0.035 g) was considered by the pilots to be mildly objectionable but tolerable.

McNeill, Water E.↗

Using depolarization to quantify ice nucleating particle concentrations: a new method

We have developed a new method to determine ice nucleating particle (INP) concentrations observed by the Texas A&M University continuous flow diffusion chamber (CFDC) under a wide range of operating conditions. In this study, we evaluate differences in particle optical properties detected by the Cloud and Aerosol Spectrometer with POLarization (CASPOL) to differentiate between ice crystals, droplets, and aerosols. The depolarization signal from the CASPOL instrument is used to determine the occurrence of water droplet breakthrough (WDBT) conditions in the CFDC. The standard procedure for determining INP concentration is to count all particles that have grown beyond a nominal size cutoff as ice crystals. During WDBT this procedure overestimates INP concentration, because large droplets are miscounted as ice crystals. Here we design a new analysis method based on depolarization ratio that can extend the range of operating conditions of the CFDC. The method agrees reasonably well with the traditional method under non-WDBT conditions with a mean percent error of ±32.1 %. Additionally, a comparison with the Colorado State University CFDC shows that the new analysis method can be used reliably during WDBT conditions.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, Laney [UC, Berkeley (main)] (ORCID:000900078↗

Signal-to-noise ratio for acoustic detection in the deep ocean

A simple method is presented for studying the thermoacoustic wave generated by a heat pulse. The signal-to-noise ratio (S/N) is then calculated for a typical hadronic-electromagnetic cascade in the deep ocean where low frequencies are masked by surface noise. It is found that a maximum useful range of about 16 km is found for typical conditions at 5 km depth. It is shown that in order to obtain useful signals with S/N greater than 100 at distances of 1 to 16 km, the cascade energy must be 10 to the 16th to 10 to the 18th eV. Finally, attention is given to further refinements of the theory of acoustic detection which remain to be investigated.

Bowen, T.↗

In-flight boundary-layer transition measurements on a swept wing

Flight tests were conducted at three different altitudes to detect transition on a smoothed test region of a swept-wing business jet wing using surface hot-film sensors and sublimating chemicals. Strong influence of sweep angle on transition location was observed when the aircraft was flown at some sideslip conditions to simulate changes in effective wing sweep angle. No effects of engine noise on transition were measured when different engine power settings were used. Flight instrumentation and ground data analysis techniques are described. Correlation was obtained between the hot-film sensor signals and sublimating chemicals for transition detection. Crossflow vortices were observed for one flight condition. Results of analyzed data for various flight-test conditions are presented.

Ahmed, Anwar↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, L. K. [UC, Berkeley (main)] (ORCID:000900078↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗

Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. Part I. Spectrum of Ho i

The Fourier Transform spectra of a Holmium hollow cathode discharge lamp have been investigated in the UV spectral range from 25,000 up to 31,530 cm{sup −1} (317 to 400 nm). Two Ho spectra have been measured with neon and argon as buffer gases. Based on the intensity ratios from these two spectra, a distinction was made between atomic and ionic lines (ionic lines are discussed in an accompanying paper). Using the known Ho i energy levels, 71 lines could be classified as transitions of atomic Ho, 34 of which have not been published previously. Another 32 lines, which could not be classified, are listed in the literature and assigned as atomic Ho. An additional 370 spectral lines have been assigned to atomic Ho based on the signal-to-noise ratio in the two spectra measured under different discharge conditions, namely with buffer gases argon and neon, respectively. These 370 lines have not been previously listed in the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of time-resolved inelastic x-ray diffraction

Starting from a general theory of time-resolved x-ray scattering, we derive a convenient expression for the diffraction signal based on a careful analysis of the relevant inelastic scattering processes. We demonstrate that the resulting inelastic limit applies to a wider variety of experimental conditions than similar, previously derived formulas, and it directly allows the application of selection rules when interpreting diffraction signals. Furthermore, we present a simple extension to systems simultaneously illuminated by x rays and a laser beam.

74 ATOMIC AND MOLECULAR PHYSICS↗