Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SATURATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Performance of Convection-Permitting and Convection-Parameterized Models in Reproducing the Extreme Precipitation Intensity Relationship with Surface Conditions

Here, this study investigates the warm-season extreme precipitation–temperature scaling relationship in CONUS404, a convection-permitting (4 km) Weather Research and Forecasting (WRF) Model simulation over the conterminous United States for the past four decades, and compares it with the WRF-Thermodynamic Global Warming (WRF-TGW) historical simulation at a coarser resolution (12 km) using parameterized convection. We also analyze the NCEP stage IV and NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement (IMERG) datasets as observational benchmarks. We examine how extreme precipitation intensity (EPI) varies with temperature and saturation deficit over representative regions based on hourly data. The stage IV and IMERG data show a similar pattern of EPI variation with temperature and saturation deficit, except that the EPI peak is lower in IMERG than in stage IV. Under dry and hot conditions, EPI decreases too rapidly with elevated saturation deficit in both CONUS404 and WRF-TGW compared to observations, but the performance of CONUS404 is superior to WRF-TGW. When the near-surface atmosphere is saturated or close to saturated, both CONUS404 and WRF-TGW produce higher peak values of EPI relative to the observational references; IMERG exhibits scaling rates close to the Clausius–Clapeyron (C–C) relationship, while CONUS404, WRF-TGW, and stage IV all demonstrate super-C–C scaling behaviors. Despite marked warming over the past four decades, in both CONUS404 and WRF-TGW, the scaling relationship between EPI and temperature in a saturated atmosphere remains stable and robust. This indicates a strong potential for the EPI–temperature scaling rate under saturation to be used as an emergent constraint in reducing uncertainties of future extreme precipitation projection.

Atmosphere↗

Center for the Study of Plasma Microturbulence

We have discovered a possible "natural fueling" mechanism in tokamak fusion reactors using large scale gyrokinetic turbulence simulation. In the presence of a heat flux dominated tokamak plasma, cold ions naturally pinch radially inward. If cold DT fuel is introduced near the edge using shallow pellet injection, the cold fuel will pinch inward, at the expense of hot helium ash going radially outward. By adjusting the cold DT fuel concentration, the core DT density profiles can be maintained. We have also shown that cold source ions from edge recycling of cold neutrals are pinched radially inward. This mechanism may be important for fully understanding the edge pedestal buildup after an ELM crash. Work includes benchmarking the gyrokinetic turbulence codes in the electromagnetic regime. This includes cyclone base case parameters with an increasing plasma beta. The code comparisons include GEM, GYRO and GENE. There is good linear agreement between the codes using the Cyclone base case, but including electromagnetics and scanning the plasma beta. All the codes have difficulty achieving nonlinear saturation as the kinetic ballooning limit is approached. GEM does not saturate well when beta gets above about 1/2 of the ideal ballooning limit. We find that the lack of saturation is due to the long wavelength k{sub y} modes being nonlinearly pumped to high levels. If the fundamental k{sub y} mode is zeroed out, higher values of beta nonlinearly saturate well. Additionally, there have been studies to better understand CTEM nonlinear saturation and the importance of zonal flows. We have continued our investigation of trapped electron mode (TEM) turbulence. More recently, we have focused on the nonlinear saturation of TEM turbulence. An important feature of TEM is that in many parameter regimes, the zonal flow is unimportant. We find that when zonal flows are unimportant, zonal density is the dominant saturation mechanism. We developed a simple theory that agrees with the simulation and predicts zonal density generation and feedback stabilization of the most unstable mode even in the absence of zonal flow. We are using GEM to simulate NSTX discharges. We have also done verification and validation on DIII-D. Good agreement with GYRO and DIII-D flux levels were reported in the core region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Hanford LAW Phase 3 Glasses

This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr 2 O 3 , K 2 O, Na 2 O, P 2 O 5 , and ZrO 2 were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al 2 O 3 , Cl - , Cr 2 O 3 , F - , K 2 O, Na 2 O, P 2 O 5 , V 2 O 5 , and ZrO 2 were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al 2 O 3 , Cl - , and F - were lower for most of the sulfur saturated glasses. The measured Cr 2 O 3 and K 2 O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions with the exception of Cr 2 O 3 concentrations, which were considerably higher than the targeted values. The measured SO 3 concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted, with significant differences among the triplicate values noted for four of the CCC glasses. Normalized concentration values for some of the study glasses were greater than the 100 g/L maximum (total dissolution), which may indicate an error in the test. It is recommended that PNNL review their performance of the PCTs to determine the cause of these potential outliers and errors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Hanford LAW Phase 3 Glasses

This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr 2 O 3 , K 2 O, Na 2 O, P 2 O 5 , and ZrO 2 were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al 2 O 3 , Cl - , Cr 2 O 3 , F - , K 2 O, Na 2 O, P 2 O 5 , V 2 O 5 , and ZrO 2 were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al 2 O 3 , Cl - , and F - were lower for most of the sulfur saturated glasses. The measured Cr 2 O 3 and K 2 O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions. The measured SO 3 concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted, with significant differences among the triplicate values noted for four of the CCC glasses. Normalized concentration values for some of the study glasses were greater than the 100 g/L maximum (total dissolution), which may indicate an error in the test. It is recommended that PNNL review the performance of the PCTs to determine the cause of these potential outliers and errors. Revision 1 of this report: Corrects an issue with high chromium measurements for the Mod glass compositions and the second set of PCT leachates, Adds data for the Mod glass wash solutions that were unintentionally omitted, Corrects an issue with rounding of the targeted Al 2 O 3 concentrations in the study glasses

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Hanford LAW Phase 3 Glasses

This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr₂O₃, K₂O, Na₂O, P₂O₅, and ZrO₂ were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al₂O₃, Cl⁻, Cr₂O₃, F⁻, K₂O, Na₂O, P₂O₅, V₂O₅, and ZrO₂ were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al₂O₃, Cl⁻, and F⁻ were lower for most of the sulfur saturated glasses. The measured Cr₂O₃ and K₂O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions. The measured SO₃ concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted. Several of the study glasses, both quenched and CCC, have NCi values that are greater than the immobilized LAW constraint of 4 g/L for B, Na, and Si.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of High Bs Fe-Ni Based Metal Amorphous Nanocomposite by Optimization of Glass Forming Ability

A growing interest in electric vehicles challenges soft magnetic materials to improve efficiency and power density. Metal amorphous nanocomposites (MANCs) have lower coercivities and eddy current losses, allowing for greater efficiency and higher switching frequency. The later allows for high motor speeds and improved power density. However, commercially available and laboratory demonstrated MANCs have shortcomings. Fe-based MANCs, such as FINEMET have excellent magnetic properties, but mechanical properties limit their application in high speed electric motors (HSMs). Fe-Co based MANCs, such as HITPERM, have high saturation inductions and good mechanical properties, but elevated magnetostrictive losses. Co-based MANCs and more recent Fe-Ni based MANCs have low losses and good mechanical properties, but lower saturation inductions (1-1.2 T), that limit power density in HSMs. Recently, much work has explored improving saturation induction in MANCs by increasing the content of magnetic elements, which comes at the cost of glass-forming ability (GFA). These efforts where generally limited to trial and error testing. Additionally, all work to date has focused on Fe-based alloys. In this work, a method of using Thermocalc simulation to locate near-eutectic compositions has been applied to Fe-Ni based alloys. Minima in liquidus temperature and solidification range were found for a ternary composition range and used to identify compositions that retain good GFA as the percentage of magnetic elements is increased. The (Fe 70 Ni 30 ) x (B-Si-Nb) 100-x alloy system for x=82% and x=85% was explored by Thermocalc simulations. This is an increase in magnetic element content compared to previously developed x=80% alloys. 3 compositions in the x=82% system, and 1 alloy in the x=85% system where identified and successfully cast as amorphous ribbon. The amorphous nature of the ribbon was confirmed by a bend test and XRD. Magnetic testing was performed by PPMS to measure saturation induction and Curie temperature of the amorphous material. The Curie temperatures increased to 407-438 °C for the x=82% alloys, and 462 °C for the x=85% alloy. Saturation induction increased to 1.28-1.36 T for the x=82% alloy and 1.48 T for the x=85% alloy, which is a significant improvement over the ~370 °C Curie temperature and 1.2 T saturation of previous Fe-Ni alloy. Crystallization behavior was studied by XRD for the x=85% alloy, showing that crystallization process follows a 2-step process of Amorphous → BCC+FCC+Amorphous → BCC+FCC+Fe 3 B+Fe 23 B 6 . Post annealing magnetic properties were studied by strip testing, and saturation induction as high as 1.48 T was seen after optimal annealing. TEM was used to study structure of as cast and annealed material. 2 alloys with x=82% compositions were identified with an optimal crystalline size of 10-20 nm, while the x=85% alloy had this structure in the as cast state. This opens the possibility of using the alloy in the as cast state, without requiring annealing. In conclusion, alloys with good GFA and improved magnetic properties were identified by Thermocalc simulation.

Krimer, Yuval↗

Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

NASA Discipline Life Sciences Technologies↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Spatiotemporal changes of seismic attenuation caused by injected CO 2 at the Frio-II pilot site, Dayton, TX, USA

A continuous active source seismic monitoring data set was collected with crosswell geometry during CO 2 injection at the Frio-II brine pilot, near Liberty, TX. Previous studies have shown that spatiotemporal changes in the P wave first arrival time reveal the movement of the injected CO 2 plume in the storage zone. To further constrain the CO 2 saturation, particularly at higher saturation levels, we investigate spatial-temporal changes in the seismic attenuation of the first arrivals. The attenuation changes over the injection period are estimated by the amount of the centroid frequency shift computed by local time-frequency analysis. We observe that (1) at receivers above the injection zone seismic attenuation does not change in a physical trend; (2) at receivers in the injection zone attenuation sharply increases following injection and peaks at specific points varying with distributed receivers, which is consistent with observations from time delays of first arrivals; then, (3) attenuation decreases over the injection time. The attenuation change exhibits a bell-shaped pattern during CO 2 injection. Under Frio-II field reservoir conditions, White's patchy saturation model can quantitatively explain both the P wave velocity and attenuation response observed. We have combined the velocity and attenuation change data in a crossplot format that is useful for model-data comparison and determining patch size. Our analysis suggests that spatial-temporal attenuation change is not only an indicator of the movement and saturation of CO 2 plumes, even at large saturations, but also can quantitatively constrain CO 2 plume saturation when used jointly with seismic velocity.

58 GEOSCIENCES↗

Detection of Anomalies in the UV/Vis Reflectances from the Ozone Monitoring Instrument

Various instrumental or geophysical artifacts, such as saturation, stray light, or obstruction of light (either coming from the instrument or related to solar eclipses), negatively impact satellite measured ultraviolet and visible Earthshine radiance spectra and downstream retrievals of atmospheric and surface properties derived from these spectra. In addition, excessive noise such as from cosmic ray impacts, prevalent within the South Atlantic Anomaly, can also degrade satellite radiance measurements. Saturation specifically pertains to observations of very bright surfaces such as sun glint over open water or thick clouds. When saturation occurs, additional photoelectric charge generated at the saturated pixel may overflow to pixels adjacent to a saturated area and be reflected as a distorted image in the final sensor output.When these effects cannot be corrected to an acceptable level for science quality retrievals, flagging of the affected pixels is indicated. Here, we introduce a straightforward detection method that is based on the correlation, r, between the observed Earthshine radiance and solar irradiance spectraover a 10 nm-spectral range; our Decorrelation Index (DI for brevity) is simply defined as DI=1-r. DI increases with anomalous additive effects or excessive noise in either radiances, the most likely cause indata from theOzone Monitoring Instrument (OMI),or irradiances. DI is relatively straight-forward to use and interpret and can be 20computed for different wavelength intervals. We developed a set of DIs for two spectral channelsof the OMI, a hyperspectral pushbroom imaging spectrometer. For each OMI spatial measurement, we define 14 wavelength-dependent DIs within the OMI visible channel (350-498 nm) and 6 DIs in its ultraviolet 2 (UV2) channel (310-370 nm). As defined, DIs reflect a continuous range of deviations of observed spectra from the reference irradiance spectrum that are complementary to the binary Saturation Possibility Warning (SPW) flags currently provided for each individual spectral/spatial pixel in the OMI radiance data set. Smaller values of DI are also caused by a number of geophysical factors; this allows one to obtain interesting physical results on the global distribution of spectral variations.

Space sensor↗

Estimation of Cs Migration under an Unsaturated Condition by Parallel-plate Experiments and 2D Advection-dispersion Model - 17188

For the assessment of the radioactive waste facility in the near-surface underground, it is important to consider the influence of the unsaturated condition flow field (hereinafter referred to as unsaturated condition) on the migration of radionuclides through the porous medium. The unsaturated condition, which is not completely saturated with liquid phase, will change the retardation effect for the migration of nuclides by interrupting the interaction of nuclides and solid phase, and by clogging flow paths with gas phase. In this study, considering the spatial distribution of the water saturation, the migration of radionuclides in the two-dimensional (2D) porous medium under the saturated flow field (hereinafter referred to as saturated condition) and unsaturated condition was examined by using the parallel-plate type's packed bed and the 2D advection-dispersion model. Besides, for comparison, the one-dimensional (1D) flow experiment using the column type's packed bed was also examined. In the experiments, a 1 mM Cs solution was injected into the beds packed with silica sand under a given constant pressure condition controlled by an overflow system. The overall effective values of retardation coefficient were estimated by applying the theoretical models to the experimental results. As a result, the overall retardation coefficient under the unsaturated condition became smaller than that under the saturated condition. This means the decrease in the effective surface area for the sorption of tracer ions in the presence of gas phase. Furthermore, under the unsaturated condition, the retardation coefficient of the 2D flow condition was estimated smaller than that of the 1D condition. That is, in the 2D flow system, the tracer ions migrate through more selective flow-paths caused by the heterogeneous spatial-distribution of water saturation which is the ratio of the volume of water to the volume of pores. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupled supercritical CO2 dissolution and water flow in pore-scale micromodels

Dissolution trapping is one of the most important mechanisms for geological carbon storage (GCS). Recent laboratory and field experiments have shown non-equilibrium dissolution of supercritical CO2 (scCO2) and coupled scCO2 dissolution and water flow, i.e., scCO2 dissolution at local pores/pore throats creating new water-flow paths, which in turn enhance dissolution by increased advection and interfacial area. However, the impacts of pore-scale characteristics on these coupled processes have not been investigated. In this study, imbibition and dissolution experiments were conducted under 40°C and 9?MPa using a homogeneous/isotropic hexagonal micromodel, two homogeneous elliptical micromodels with low or high anisotropy, and a heterogeneous sandstone-analog micromodel. The four micromodels, initially saturated with deionized (DI)-water, were drained by injecting scCO2 to establish a stable scCO2 saturation. DI water was then injected at different rates with logCa (the capillary number) ranging from -6.56 to -4.34. Results show that bypass of scCO2 by displacing water is the dominant mechanism contributing to the residual CO2 trapping, triggered by heterogeneity in pore characteristics or pore-scale scCO2-water distribution. Bypass can be enhanced by pore heterogeneity or reduced by increasing transverse permeability, resulting in relatively low (<2% of CO2 solubility) or high (9–13% of CO2 solubility) dissolved CO2 concentration in displacing water. The overall dissolution of residual scCO2 increases with decreasing Ca, and approaches to their solubility at low Ca value with sufficient residence time. This main trend is similar to a capillary desaturation curve that represents the relationship between the residual saturation and Ca. Spatially, dissolution initiates along the boundary of bypassed scCO2 cluster(s) in a non-equilibrium manner, and the coupling of water flow and dissolution occurs which fragments the bypassed scCO2 clusters and enhance scCO2 dissolution.

Chang, Chun↗

Experimental study of three-dimensional CO 2 -water drainage and fracture-matrix interactions in fractured porous media

Estimation of CO 2 storage capacity in fractured porous reservoirs requires a better understanding of the CO 2 -water flow fundamentals in fracture-matrix systems. There are few core-flood experiments on three-dimensional CO 2 -water drainage in a fracture-matrix system, yet none have examined the impacts of the capillary continuity of fractures and fracture-matrix interactions. In this study, twelve drainage experiments were conducted in four fracture-matrix columns, each comprising a vertical stack of a cylindrical rock core, a filter paper serving as an analogue to a horizontal fracture, and a ceramic plate. Here, the core sample was surrounded by open space at the top and circumferential sides to model fractures, allowing for 3-D CO 2 -water drainage in the rock core and displaced water draining across the horizontal fracture. X-ray computed tomography was conducted to visualize the dynamic invasion/drainage processes in four rock core samples showing contrasts in anisotropy, permeability, and heterogeneity. Experimental results show (1) the equilibrium CO 2 saturations in the rock matrix vary from 0.10 to 0.60 at controlled capillary pressures up to 200 kPa, (2) the CO 2 saturations in the matrix increase with water saturation in the horizontal fracture resulting in better capillary continuity for water to drain across the fracture, and (3) the fracture water saturation can be enhanced by the non-uniform fracture capillary pressure and countercurrent flow of CO 2 and water across the fracture-matrix interface. In the case of high fracture water saturation, matrix CO 2 saturation largely depends on matrix anisotropy and heterogeneity. The core-scale experimental results contribute to understand the fracture-matrix interactions and CO 2 storage efficiency in fractured porous media.

54 ENVIRONMENTAL SCIENCES↗

Hanford tank residual waste – contaminant source terms and release models

Residual waste is expected to be left in 177 underground storage tanks after closure at the U.S. Department of Energy’s Hanford Site in Washington State (USA). In the long term, the residual wastes represent a potential source of contamination to the subsurface environment. Residual materials that cannot be completely removed during the tank closure process are being studied to identify and characterize the solid phases and estimate the release of contaminants from these solids to water that might enter the closed tanks in the future. As of the end of 2009, residual waste from five tanks has been evaluated. Residual wastes from adjacent tanks C-202 and C-203 have high U concentrations of 24 and 59 wt%, respectively, while residual wastes from nearby tanks C-103 and C-106 have low U concentrations of 0.4 and 0.03 wt%, respectively. Aluminum concentrations are high (8.2 to 29.1 wt%) in some tanks (C-103, C-106, and S-112) and relatively low (<1.5 wt%) in other tanks (C-202 and C-203). Gibbsite is a common mineral in tanks with high Al concentrations, while non-crystalline U-Na-C-O-P±H phases are common in the U-rich residual wastes from tanks C-202 and C-203. Iron oxides/hydroxides have been identified in all residual waste samples studied to date. Contaminant release from the residual wastes was studied by conducting batch leach tests using distilled deionized water, a Ca(OH)2-saturated solution, or a CaCO3-saturated water. Uranium release concentrations are highly dependent on waste and leachant compositions with dissolved U concentrations one or two orders of magnitude higher in the tests with high U residual wastes, and also higher when leached with the CaCO3-saturated solution than with the Ca(OH)2-saturated solution. Technetium leachability is not as strongly dependent on the concentration of Tc in the waste, and it appears to be slightly more leachable by the Ca(OH)2-saturated solution than by the CaCO3-saturated solution. In general, Tc is much less leachable (<10 wt% of the available mass in the waste) than previously predicted. This may be due to the coprecipitation of trace concentrations of Tc in relatively insoluble phases such as Fe oxide/hydroxide solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental study of potential wellbore cement carbonation by various phases of carbon dioxide during geologic carbon sequestration

Hydrated Portland cement was reacted with carbon dioxide (CO2) in supercritical, gaseous, and aqueous phases to understand the potential cement alteration processes along the length of a wellbore, extending from deep CO2 storage reservoir to the shallow subsurface during geologic carbon sequestration. The 3-D X-ray microtomography (XMT) images displayed that the cement alteration was significantly more extensive by CO2-saturated synthetic groundwater than dry or wet supercritical CO2 at high P (10 MPa)-T (50°C) conditions. Scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) analysis also exhibited a systematic Ca depletion and C enrichment in cement matrix exposed to CO2-saturated groundwater. Integrated XMT, XRD, and SEM-EDS analyses identified the formation of extensive carbonated zone filled with CaCO3(s), as well as the porous degradation front and the outermost silica-rich zone in cement after exposure to CO2-saturated groundwater. The cement alteration by CO2-saturated groundwater for 2-8 months overall decreased the porosity from 31% to 22% and the permeability by an order of magnitude. Cement alteration by dry or wet supercritical CO2 was slow and minor compared to CO2-saturated groundwater. A thin single carbonation zone was formed in cement after exposure to wet supercritical CO2 for 8 months or dry supercritical CO2 for 15 months. Extensive calcite coating was formed on the outside surface of a cement sample after exposure to wet gaseous CO2 for 1-3 months. The chemical-physical characterization of hydrated Portland cement after exposure to various phases of carbon dioxide indicates that the extent of cement carbonation can be significantly heterogeneous depending on CO2 phase present in the wellbore environment. Both experimental and geochemical modeling results suggest that wellbore cement exposure to supercritical, gaseous, and aqueous phases of CO2 during geologic carbon sequestration is unlikely to damage the wellbore integrity because cement alteration by all phases of CO2 is dominated by carbonation reaction. This is consistent with previous field studies of wellbore cement with extensive carbonation after exposure to CO2 for 3 decades. However, XMT imaging indicates that preferential cement alteration by supercritical CO2 or CO2-saturated groundwater can occur along the cement-steel or cement-rock interfaces. This highlights the importance of further investigation of cement degradation along the interfaces of wellbore materials to ensure permanent geologic carbon storage.

Calcite↗