Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

The beam test of muon detector parameters for the SHiP experiment at CERN

Scintillation detectors based on extruded plastics have been tested in a 10 GeV/c beam at CERN. The scintillation signal readout was provided using optical wavelength shifting fibers Y11 Kuraray and Hamamatsu MPPC micropixel avalanche photodiodes. The light yield was scanned along and across the detectors. Time resolution was found by fitting the MPPC digitized pulse rise and other methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tests of Scintillator+WLS Strips for Muon System at Future Colliders

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been achieved, as well as time resolution of 0.5 ns and position resolution of ~ 7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for New Physics in Top Quark Production and Upgrade of the CMS Hadron Calorimeter

Our goal is to measure precisely the properties of the heaviest subatomic particle ever discovered, the top quark. In the proton-proton collisions at the LHC, top quarks are produced copiously. The largest set of top quarks recorded by the CMS detector make it an ideal laboratory to measure properties such as its mass and the rate at which pair of top quarks are produced in association with energetic photons. Quantum electrodynamics, or QED, describes the emission of light by charged particles and is the most precise physics theory ever devised. Typically this means light emitted by electrons, but any charged particles will do, such as the top quark. Studies of the light-emitting properties of top quarks help us to refine our current theoretical predictions at the finest level, and provide additional tools to study in more detail the recently discovered Higgs boson particle. However, during this process, the studies may reveal interesting features not yet observed. Deviations from the standard predictions would be a strong sign of something entirely new. These new physics theories are motivated to answer the current big mysteries in the universe such as what is the nature of mass or what is dark matter. As the LHC increases the collision energy and its luminosity, the detectors need to be improved to cope with these high-luminosity scenarios. New sensors will be installed in the hadron calorimeter detectors along with new front and end electronics at the end of 2016. We are testing and calibrating the new front-end readout electronics that will allow us to have more options to reduce the noise on these detectors. In order to do this calibration, we have developed a system that can inject electric charge in the full range of the charge integrator chip, the QIE ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Construction of Detector and Data Acquisition Elements for Proton Computed Tomography

Proton computed tomography (pCT) offers an alternative to x-ray imaging with potential for three-dimensional imaging, reduced radiation exposure, and in-situ imaging. Northern Illinois University (NIU) is developing a second-generation proton computed tomography system with a goal of demonstrating the feasibility of three-dimensional imaging within clinically realistic imaging times. The second-generation pCT system is comprised of a tracking system, a calorimeter, data acquisition, a computing farm, and software algorithms. The proton beam encounters the upstream tracking detectors, the patient or phantom, the downstream tracking detectors, and a calorimeter. The schematic layout of the PCT system is shown. The data acquisition sends the proton scattering information to an offline computing farm. Major innovations of the second generation pCT project involve an increased data acquisition rate ( MHz range) and development of three-dimensional imaging algorithms. The Fermilab Particle Physics Division and Northern Illinois Center for Accelerator and Detector Development at Northern Illinois University worked together to design and construct the tracking detectors, calorimeter, readout electronics and detector mounting system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heavy Flavor Physics at the sPHENIX Experiment

The sPHENIX experiment is a state-of-the-art jet and heavy flavor physics detector, which successfully recorded its first Au + Au collision data at 200 GeV at the Relativistic Heavy Ion Collider (RHIC). sPHENIX will provide heavy flavor physics measurements at RHIC, covering an unexplored kinematic region and unprecedented precision, to probe the parton energy loss mechanism, parton transport coefficients in quark–gluon plasma, and the hadronization process under various medium conditions. At the center of sPHENIX, the monolithic active pixel sensor (MAPS)-based VerTeX detector (MVTX) is a high-precision silicon pixel detector. The MVTX provides excellent position resolution and the capability of operating in continuous streaming readout mode, allowing precise vertex determination and recording a large data sample, both of which are particularly crucial for heavy flavor physics measurements. In this work, we will show the general performance of heavy-flavor hadron reconstruction. In addition, we will discuss the commissioning experience with sPHENIX. Finally, we will provide the projection of b-hadron and jet observables and discuss the estimated constraints on theoretical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A PRACTICAL THEOREM ON USING INTERFEROMETRY TO MEASURE THE GLOBAL 21 cm SIGNAL

The sky-averaged, or global, background of redshifted 21 cm radiation is expected to be a rich source of information on cosmological reheating and reionization. However, measuring the signal is technically challenging: one must extract a small, frequency-dependent signal from under much brighter spectrally smooth foregrounds. Traditional approaches to study the global signal have used single antennas, which require one to calibrate out the frequency-dependent structure in the overall system gain (due to internal reflections, for example) as well as remove the noise bias from auto-correlating a single amplifier output. This has motivated proposals to measure the signal using cross-correlations in interferometric setups, where additional calibration techniques are available. In this paper we focus on the general principles driving the sensitivity of the interferometric setups to the global signal. We prove that this sensitivity is directly related to two characteristics of the setup: the cross-talk between readout channels (i.e., the signal picked up at one antenna when the other one is driven) and the correlated noise due to thermal fluctuations of lossy elements (e.g., absorbers or the ground) radiating into both channels. Thus in an interferometric setup, one cannot suppress cross-talk and correlated thermal noise without reducing sensitivity to the global signal by the same factor—instead, the challenge is to characterize these effects and their frequency dependence. We illustrate our general theorem by explicit calculations within toy setups consisting of two short-dipole antennas in free space and above a perfectly reflecting ground surface, as well as two well-separated identical lossless antennas arranged to achieve zero cross-talk.

79 ASTRONOMY AND ASTROPHYSICS↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters), but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/f noise as compared to sum extraction. We evaluate the noise introduced by pre-amplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four parameter pulse height analyzer

Circuit design modification of converter and readout system by addition of charge amplifiers at inputs and by addition of fourth D channel- four-parameter pulse height analyzer

PARAMETRIC AMPLIFIER↗

Characterization of large area ZnS(Ag) detector for gross alpha and beta activity measurements in tap water plants

In this work we present the characterization of a large area 200 x 200 mm{sup 2} EJ-444 scintillation detector to be used for monitoring gross alpha and beta activity in tap water plants. Specific tests were performed to determine the best setup to readout the light from the detector side in order to have the possibility to stack many detectors and get a compact device with total active area of the order of 1 m{sup 2}. Alpha/Beta discrimination, efficiency and homogeneity tests were carried out with alpha and beta sources. Background from ambient radioactivity was measured as well. Alpha/beta real-time monitoring in drinking water is a goal of the EU project TAWARA{sub R}TM. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent development of the Multi-Grid detector for large area neutron scattering instruments

Most of the Neutron Scattering facilities are committed in a continuous program of modernization of their instruments, requiring large area and high performance thermal neutron detectors. Beside scintillators detectors, {sup 3}He detectors, like linear PSDs (Position Sensitive Detectors) and MWPCs (Multi-Wires Proportional Chambers), are the most current techniques nowadays. Time Of Flight instruments are using {sup 3}He PSDs mounted side by side to cover tens of m{sup 2}. As a result of the so-called '{sup 3}He shortage crisis{sup ,} the volume of 3He which is needed to build one of these instruments is not accessible anymore. The development of alternative techniques requiring no 3He, has been given high priority to secure the future of neutron scattering instrumentation. This is particularly important in the context where the future ESS (European Spallation Source) will start its operation in 2019-2020. Improved scintillators represent one of the alternative techniques. Another one is the Multi-Grid introduced at the ILL in 2009. A Multi-Grid detector is composed of several independent modules of typically 0.8 m x 3 m sensitive area, mounted side by side in air or in a vacuum TOF chamber. One module is composed of segmented boron-lined proportional counters mounted in a gas vessel; the counters, of square section, are assembled with Aluminium grids electrically insulated and stacked together. This design provides two advantages: First, magnetron sputtering techniques can be used to coat B{sub 4}C films on planar substrates, and second, the neutron position along the anode wires can be measured by reading out individually the grid signals with fast shaping amplifiers followed by comparators. Unlike charge division localisation in linear PSDs, the individual readout of the grids allows operating the Multi-Grid at a low amplification gain, hence this detector is tolerant to mechanical defects and its production accessible to laboratories equipped with standard equipment. Prototypes of different configurations and sizes have been developed and tested. A demonstrator, with a sensitive area of 0.8 m x 3 m, has been studied during the CRISP European project; it contains 1024 grids, and a surface of isotopically enriched B{sub 4}C film close to 80 m{sup 2}. Its size represented a challenge in terms of fabrication and mounting of the detection elements. Another challenge was to make the gas chamber mechanically compatible with operation in a vacuum TOF chamber. Optimal working condition of this detector was achieved by flushing Ar-CO{sub 2} at a pressure of 50 mbar, and by applying 400 Volts on the anodes. This unusual gas pressure allows to greatly simplifying the mechanics of the gas vessel in vacuum. The detection efficiency has been measured with high precision for different film thicknesses. 52% has been measured at 2.5 Angstrom, in good agreement with the MC simulation. A high position resolution has been achieved by centre of gravity measurement of the TOT (Time-Over-Threshold) signals between neighbouring grids. These results, as well as other detection parameters, including gamma sensitivity and spatial uniformity, will be presented. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Prototype Large Area Detector Module for Muon Scattering Tomography

Abstract-Shielded special nuclear materials (SNM) are of concern as some fissile isotopes have low gamma and neutron emission rates. These materials are also easily shielded to the point where their passive emissions are comparable to background. Consequently, shielded SNM is very challenging for passive radiation detection portals which scan cargo containers. One potential solution for this is to utilise the natural cosmic ray muon background and examine how these muons scatter from materials inside the container volume, terms; the muon scattering tomography (MST) technique measures the three-dimensional localised scattering at all points within a cargo container, providing a degree of material discrimination. There is the additional benefit that the MST signal increases with the presence of more high density shielding materials, in contrast to passive radiation detection. Simulations and calculations suggest that the effectiveness of the technique is sensitive to the tracking accuracy amongst other parameters, motivating the need to develop practical detector systems that are capable of tracking cosmic ray muons. To this end, we have constructed and tested a 2 m by 2 m demonstration module based on gaseous drift chambers and triggered by a large area scintillator-based detector, which is readout by wavelength shifting fibres. We discuss its design, construction, characterisation and operational challenges. (authors)

42 ENGINEERING↗