Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RUPTURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

An updated Lagrangian LBM–DEM–FEM coupling model for dual-permeability fissured porous media with embedded discontinuities

Many engineering applications and geological processes involve embedded discontinuities in porous media across multiple length scales (e.g. rock joints, grain boundaries, deformation bands and faults). Understanding the multiscale path-dependent hydro-mechanical responses of these interfaces across length scales is of ultimate importance for applications such as CO 2 sequestration, hydraulic fracture and earthquake rupture dynamics. While there exist mathematical frameworks such as extended finite element and assumed strain to replicate the kinematics of the interfaces, modeling the cyclic hydro-mechanical constitutive responses of the interfaces remains a difficult task. Here this paper presents a semi-data-driven multiscale approach that obtains both the traction-separation law and the aperture-porosity–permeability relation from micro-mechanical simulations performed on representative elementary volumes in the finite deformation range. To speed up multiscale simulations, the incremental constitutive updates of the mechanical responses are obtained from discrete element simulations at the representative elementary volume whereas the hydraulic responses are generated from a neural network trained with data from lattice Boltzmann simulations. These responses are then linked to a macroscopic dual-permeability model. This approach allows one to bypass the need of deriving multi-physical phenomenological laws for complex loading paths. More importantly, it enables the capturing of the evolving anisotropy of the permeabilities of the macro- and micro-pores. A set of numerical experiments are used to demonstrate the robustness of the proposed model.

42 ENGINEERING↗

A multiscale phase field fracture approach based on the non-affine microsphere model for rubber-like materials

Rubber-like materials have a broad scope of applications due to their unique properties like high stretchability and increased toughness. Hence, computational models for simulating their fracture behavior are paramount for designing them against failures. In this study, the phase field fracture approach is integrated with a multiscale polymer model for predicting the fracture behavior in elastomers. At the microscale, damaged polymer chains are modeled to be made up of a number of elastic chain segments pinned together. Using the phase field approach, the damage in the chains is represented using a continuous variable. Both the bond stretch internal energy and the entropic free energy of the chain are assumed to drive the damage, and the advantages of this assumption are expounded. A framework for utilizing the non-affine microsphere model for damaged systems is proposed here by considering the minimization of a hypothetical undamaged free energy, ultimately connecting the chain stretch to the macroscale deformation gradient. At the macroscale, a thermodynamically consistent formulation is derived in which the total dissipation is assumed to be mainly due to the rupture of molecular bonds. Using a monolithic scheme, the proposed model is numerically implemented and the resulting three-dimensional simulation predictions are compared with existing experimental data. The capability of the model to qualitatively predict the propagation of complex crack paths and quantitatively estimate the overall fracture behavior is verified. Additionally, the effect of the length scale parameter on the predicted fracture behavior is studied for an inhomogeneous system.

97 MATHEMATICS AND COMPUTING↗

Dynamic modeling of injection-induced fault reactivation and ground motion and impact on surface structures and human perception

We summarize recent modeling studies of injection-induced fault reactivation, seismicity, and its potential impact on surface structures and nuisance to the local human population. We used coupled multiphase fluid flow and geomechanical numerical modeling, dynamic wave propagation modeling, seismology theories, and empirical vibration criteria from mining and construction industries. We first simulated injection-induced fault reactivation, including dynamic fault slip, seismic source, wave propagation, and ground vibrations. From co-seismic average shear displacement and rupture area, we determined the moment magnitude to about M w = 3 for an injection-induced fault reactivation at a depth of about 1000 m. We then analyzed the ground vibration results in terms of peak ground acceleration (PGA), peak ground velocity (PGV), and frequency content, with comparison to the U.S. Bureau of Mines’ vibration criteria for cosmetic damage to buildings, as well as human-perception vibration limits. For the considered synthetic M w = 3 event, our analysis showed that the short duration, high frequency ground motion may not cause any significant damage to surface structures, and would not cause, in this particular case, upward CO 2 leakage, but would certainly be felt by the local population.

58 GEOSCIENCES↗

Effective detection of CO 2 leakage: a comparison of groundwater sampling and pressure monitoring

Shallow aquifer monitoring is likely to be a required aspect to any geologic CO 2 sequestration operation. Collecting groundwater samples and analyzing for geochemical parameters such as pH, alkalinity, total dissolved carbon, and trace metals has been suggested by a number of authors as a possible strategy to detect CO 2 leakage. The effectiveness of this approach, however, will depend on the hydrodynamics of the leak-induced CO 2 plume and the spatial distribution of the monitoring wells relative to the origin of the leak. To our knowledge, the expected effectiveness of groundwater sampling to detect CO 2 leakage has not yet been quantitatively assessed. In this study we query hundreds of simulations developed for the National Risk Assessment Project (US DOE) to estimate risks to drinking water resources associated with CO 2 leaks. The ensemble of simulations represent transient, 3-D multi-phase reactive transport of CO 2 and brine leaked from a sequestration reservoir, via a leaky wellbore, into an unconfined aquifer. Key characteristics of the aquifer, including thickness, mean permeability, background hydraulic gradient, and geostatistical measures of aquifer heterogeneity, were all considered uncertain parameters. Complex temporally-varying CO 2 and brine leak rate scenarios were simulated using a heuristic scheme with ten uncertain parameters. The simulations collectively predict the spatial and temporal evolution of CO 2 and brine plumes over 200 years in a shallow aquifer under a wide range of leakage scenarios and aquifer characteristics. Using spatial data from an existing network of shallow drinking water wells in the Edwards Aquifer, TX, as one illustrative example, we calculated the likelihood of leakage detection by groundwater sampling. In this monitoring example, there are 128 wells available for sampling, with a density of about 2.6 wells per square kilometer. If the location of the leak is unknown a priori, a reasonable assumption in many cases, we found that the leak would be detected in at least one of the monitoring wells in less than 10% of the scenarios considered. This is because plume sizes are relatively small, and so the probability of detection decreases rapidly with distance from the leakage point. For example, 400m away from the leakage point there is less than 20% chance of detection. We then compared the effectiveness of groundwater quality sampling to shallow aquifer and/or reservoir pressure monitoring. For the Edwards Aquifer example, pressure monitoring in the same monitoring well network was found to be even less effective that groundwater quality monitoring. This is presumably due to the unconfined conditions and relatively high permeability, so pressure perturbations quickly dissipate. Although specific results may differ from site to site, this type of analysis should be useful to site operators and regulators when selecting leak detection strategies. Given the spatial characteristics of a proposed monitoring well network, probabilities of leakage detection can be rapidly calculated using this methodology. Although conditions such as these may not be favorable for leakage detection in shallow aquifers, leakage detection could be much more successful in the injection reservoir. We demonstrate proof-of-concept for this hypothesis, presenting a simulation where there is measurable pressure change at the injection well due to overpressurization, fault rupture, and consequent leakage up the fault into intermediate and shallow aquifers. The size of the detectible pressure change footprint is much larger in the reservoir than in either of the overlying aquifers. Further exploration of the range of conditions for which this technique would be successful is the topic of current study.

54 ENVIRONMENTAL SCIENCES↗

Impact of induced seismic events on seal integrity, Texas Gulf Coast

Recent publications have suggested that large-scale CO 2 injection could trigger earthquakes and that even small- to moderate-sized earthquakes may threaten the seal integrity of the injection zone, and potentially damage buildings and other surface structures. In this study, we compared seal thickness to estimated fault displacement due to a single hypothetical seismic event in a selected area of the Texas Gulf Coast comprising an offshore strip of state waters along two Texas counties. To evaluate the slip generated by a single seismic event, we compiled well log information on shale/sand sequences and seismic information on fault geometric characteristics of a section of Lower Miocene age. The section is thousands of feet thick and is overlain and underlain by marine shales (Amph. B and Anahuac, respectively) that are relatively easy to correlate between wells. The Amph. B. shale is the secondary and ultimate seal for all injection intervals in the Lower Miocene. Given its thickness, no realistic seismic event or small series of seismic events will offset it significantly. However, this may not be true of smaller local primary seals. An analysis of geophysical logs of a total of 71 wells yielded a total of 2,871 sand / shale binary intervals. An analysis of the dedicated 3D seismic survey counted 723 fault traces at five roughly horizontal horizons within the Lower Miocene Fault displacement estimated using the product of the fault length times an uncertain multiplier coefficient assumed to follow a triangular distribution with a 10 -3 to 10 -5 range and a mode of 8 × 10 -5 . We then compared estimated single-event fault displacements to seal thicknesses by means of a Monte-Carlo analysis. Only 1.8% of thickness/displacement pairs display a displacement greater than 20% of the seal thickness. Only 0.26% of the pairs result in a displacement of half the seal thickness and only 0.05% of thickness/displacement pairs result in a clear seal rupture. The next step was to compare the magnitude of the event generated by such a displacement to documented magnitudes of “large” earthquakes generated by waterflooding and fluid disposal. Based on this analysis, we conclude that seismicity that may arise from CO 2 injection appears not to be a serious complication for CO 2 storage integrity, at least in the Gulf Coast area.

54 ENVIRONMENTAL SCIENCES↗

Development of a health monitoring framework: Application to a supercritical pulverized coal-fired boiler

In this study, this work details the development of a physics-based equipment health monitoring framework for a supercritical boiler, using first-principles models to estimate the remaining useful life (RUL) of its components. The framework accounts for fatigue and creep life consumption, generating spatio-temporal variations in mechanical and thermal stress. Analysis of the stress profile throughout the boiler highlights the finishing superheater inlet steam header as a vulnerable location susceptible to damage from cycling operation. The framework also yields quantified uncertainty in the RUL projection for specific locations, accounting for uncertainties in material properties and boiler operation. Results indicate that operational uncertainties (e.g., seasonal variation and operational strategy) and material properties (e.g., rupture time coefficients, Young’s modulus, yield strength, and coefficient of thermal expansion) significantly impact the RUL of the finishing superheater inlet steam header. Additionally, case studies demonstrate the use of the health monitoring framework as a predictive tool for operational planning under uncertainty, including scenarios with and without updates on the operation of the boiler.

20 FOSSIL-FUELED POWER PLANTS↗

Kinematics of the 2015 San Ramon, California earthquake swarm: Implications for fault zone structure and driving mechanisms

Earthquake swarms represent a sudden increase in seismicity that may indicate a heterogeneous fault-zone, the involvement of crustal fluids and/or slow fault slip. Swarms sometimes precede major earthquake ruptures. An earthquake swarm occurred in October 2015 near San Ramon, California in an extensional right step-over region between the northern Calaveras Fault and the Concord–Mt. Diablo fault zone, which has hosted ten major swarms since 1970. The 2015 San Ramon swarm is examined here from 11 October through 18 November using template matching analysis. The relocated seismicity catalog contains ~4000 events with magnitudes between -0.2 < M d < 3.6. The swarm illuminated three sub-parallel, southwest striking and northwest dipping fault segments of km-scale dimension and thickness of up to 200 m. The segments contain coexisting populations of different focal-mechanisms, suggesting a complex fault zone structure with several sets of en échelon fault orientations. The migration of events along the three planar structures indicates a complex fluid and faulting interaction processes. We searched for correlations between seismic activity and tidal stresses and found some suggestive features, but nothing that we can be confident is statistically significant.

58 GEOSCIENCES↗

Sidewall Breach During Lithium-Ion Battery Thermal Runaway Triggered by Cell-to-Cell Propagation Visualized Using High-Speed X-Ray Imaging

With the rapid deployment of Li-ion batteries (LiBs) in a range of applications, it is crucial to ensure their safe operation. Therefore, it is necessary to investigate the rapid thermal runaway failure that LiBs can undergo if improperly operated or subjected to abuse scenarios so that hazardous events can be avoided or mitigated. Sidewall breaches or ruptures of LiBs during thermal runaway are considered the most hazardous failure scenario, resulting in hot abrasive flare from the casing of the cell that can impinge on neighbouring cells and lead to the propagation of thermal runaway throughout a battery pack. Yet, the process leading up to the sidewall breach is not well understood due to the extreme difficulty in visualizing such a failure in commercially relevant cells. With the application of a newly developed chamber for remote-controlled abuse testing of batteries coupled with simultaneous X-ray imaging, we demonstrate here for the first time an in-situ visualization of a sidewall breach. By further applying spatiotemporal mapping techniques, the internal thermal runaway events leading up to the sidewall breach can be analyzed in detail. Subsequently, the speed of the electrode layer delamination could be calculated to a speed of 0.6 m/s. These new insights bring more clarity regarding this phenomenon, that in turn can help battery designers improve battery safety.

battery safety↗

Assessing barotrauma in neutrally and negatively bouyant juvenile salmonids exposed to simulated hydro-turbine passage using a mobile aquatic barotrauma laboratory

Barotrauma, injuries sustained following rapid decompression, occurs in many different fisheries applications. Previous attempts to quantify barotrauma in fish have been limited by hyper/hypobaric system function. Further, field studies are often confounded by covariates. The Mobile Aquatic Barotrauma Laboratory (MABL) was designed to address these limitations. Specifically, this testing facility allows the user to evaluate similar complex pressure scenarios that migrating juvenile salmonids are exposed to following turbine or spillway passage. In addition, factors including total dissolved gas, temperature, and acclimation pressure are controlled automatically with this mobile lab. In this paper we also present a case study where negative and neutrally buoyant juvenile Chinook salmon were exposed to simulated hydro-turbine passage (STP). Gill emboli, swim bladder rupture, mortality, and internal haemorrhaging were used as end points. The severity of the decompression profile and the fish’s ability to gain neutral buoyancy were used as predictor variables. We determined that fish that achieved neutral buoyancy during a 16 hour acclimation period had a greater risk of injury following STP than negatively buoyant conspecifics. This research solidifies the need to allow fish to become neutrally buoyant when assessing barotrauma and mortality in field and laboratory applications. Finally, MABL can be configured to examine a variety of different species and pressure profiles, and physical parameters in a controlled environment.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of thermal and radiation induced creep in the dual cooled lead lithium blanket

The creep in recently designed blanket for the fusion nuclear science facility is described by decomposing it into thermal, irradiation and cavity swelling creep. Initial estimates of thermal creep using elastic high temperature rules showed that the recent heat transfer improvements at the first wall (FW) is feasible, and the FW can withstand heat flux of 0.35 MW/m 2 at 3000 hrs without rupture. A viscoplastic model that is based on Norton's power law and relies on Multiphysics coupling of solid mechanics and heat transfer modules is used to capture the inelastic deformation in the blanket. Results showed that the design peak heat flux of 0.25 MW/m 2 produced maximum thermal creep strain of 0.45 % and the relaxation of the thermal stress at the FW. Irradiation creep is prescribed to be proportional to the displacement damage dose and applied stress. The displacements from irradiation creep radially decrease from the FW to the back wall, but the maximum deformation is found at the back wall that is connected to the Helium manifold due to the high stresses at the region. In conclusion, cavity swelling creep is dominant at steady state and combined with radiation creep to produce displacement of about 8 mm at the FW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of anisotropy and texture on the low cycle fatigue behavior of Inconel 718 processed via electron beam melting

Here in this study, the impact of texture (columnar/equiax grain structure) and influence of material orientation on the low cycle fatigue (LCF) behavior of hot isostatic pressed (HIP) and heat-treated Inconel 718 fabricated through electron beam melting (EBM) is investigated. Material was tested both parallel and perpendicular (transverse) to the build direction. In all instances, the EBM HIP and heat-treated Inconel 718 performed similarly or exceeded the LCF life of wrought Inconel 718 plate and bar stock under fully reversed strain-controlled loading at 650 °C. Amongst the textures, the columnar grains oriented parallel to the build direction exhibited the highest life on average compared to the transverse columnar and equiax EBM material. Further, in relation to the reference wrought material the parallel columnar grain material exhibited a greater life. While a negligible life difference was observed in the equiax grained material between the two orientations, a consistently lower accumulated inelastic strain was measured for the material loaded parallel to the build direction than the transverse orientation. Failure of the parallel columnar material occurred in a transgranular manner with cracks emanating from the surface whereas the transverse columnar material failed in a intergranular manner, with crack growth occurring through repeated rupture of oxide at the crack-tip. Finally, in the case of the equiax material, an influence of material orientation was not observed on the failure mechanism with crack propagation occurring through a combination of debonded/cracked carbides and void formation along twin boundaries resulting in a mixture of intergranular and transgranular crack propagation.

36 MATERIALS SCIENCE↗

Modeling of induced seismicity and ground vibrations associated with geologic CO 2 storage, and assessing their effects on surface structures and human perception

In this paper, we present model simulations of ground motions caused by CO 2 -injection-induced fault reactivation and analyze the results in terms of the potential for damage to ground surface structures and nuisance to the local human population. It is an integrated analysis from cause to consequence, including the whole chain of processes starting from earthquake inception in the subsurface, wave propagation toward the ground surface, and assessment of the consequences of ground vibration. For a small magnitude (M w =3) event at a hypocenter depth of about 1000m, we first used the simulated ground-motion wave train in an inverse analysis to estimate source parameters (moment magnitude, rupture dimensions and stress drop), achieving good agreement and thereby verifying the modeling of the chain of processes from earthquake inception to ground vibration. We then analyzed the ground vibration results in terms of peak ground acceleration (PGA), peak ground velocity (PGV) and frequency content, with comparison to U.S. Geological Survey's instrumental intensity scales for earthquakes and the U.S. Bureau of Mines' vibration criteria for cosmetic damage to buildings, as well as human-perception vibration limits. Our results confirm the appropriateness of using PGV (rather than PGA) and frequency for the evaluation of potential ground-vibration effects on structures and humans from shallow injection-induced seismic events. For the considered synthetic M w =3 event, our analysis showed that the short duration, high frequency ground motion may not cause any significant damage to surface structures, but would certainly be felt by the local population.

54 ENVIRONMENTAL SCIENCES↗

Field-scale fault reactivation experiments by fluid injection highlight aseismic leakage in caprock analogs: Implications for CO 2 sequestration

Observations on tens-of-meter scale experiments of fault activation by fluid injection conducted in shales allow exploring how aseismic and seismic events may jeopardize the integrity of a sealing caprock overlying a CO 2 sequestration reservoir. We contrast the behavior of shale faults with another set of experiments conducted in carbonates. Significant fluid leakage occurs along the initially low-permeability shale faults when rupture is activated. Most of the leakage pathway closes when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed leakage behavior, which is also caused by fault opening favored by the softness of the shale, and by the structure of the fault zone that prevents fluids from diffusing into the adjacent damage zone. Experiments show a large amount of aseismic deformation. Small-magnitude seismicity (M w < -2.5) is observed outside the pressurized leakage patch. Stress transferred from this aseismic deformation patch can build up to stress-criticality and favor seismicity. Thus, in terms of fault activation in caprocks, aseismic fault slip leading to increased permeability and a loss of seal integrity is of great concern.

58 GEOSCIENCES↗

Linking structure to performance: Characterization of porous transport layers for high-pressure water electrolysis

Proton exchange membrane (PEM) water electrolysis is a promising technology to produce cost-efficient hydrogen. PEM electrolyzers offer a large current density range and the ability to operate at differential pressure which can be used to minimize both capital and operational expenditures. However, directly producing pressurized hydrogen at the cathode results in pushing the membrane against the anode porous transport layer (PTL). This can lead to detrimental effects, such as membrane deformation or ruptures, which depend on membrane properties as well as PTL material properties such as pore size, structure, and morphology. In this work, a range of sinter and felt-based commercial PTLs are evaluated for their contributions to the cell's electrochemical and H 2 crossover performance at cathode pressures up to 30 bar. X-ray tomography and post-operando optical microscopy are used to assess the morphology of the PTLs, and the PTL induced deformation experienced by the catalyst coated membrane (CCM), respectively. PTL samples with lower porosity were found to reduce both the cell voltage and the amount of H 2 permeating from the cathode to the anode exhaust, which was ascribed to improved catalyst layer contact and reduced membrane deformation, respectively. The best performing PTLs improved electrolyzer efficiency by ~1.5 kWh/kg H2 . Specifically, 1 kWh/kg H2 was gained due to reducing membrane deformation and decreasing H 2 crossover. The remainder 0.5 kWh/kg H2 were achieved by improving the electrical contact at the electrode/PTL interface which decreased cell voltage.

08 HYDROGEN↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coupled geomechanical investigation of depletion-induced fault reactivation

Fault reactivation during subsurface fluid production pose significant challenges to safe and sustainable resource extraction. Here, this study presents a three-dimensional coupled geomechanical framework to investigate the processes driving fault reactivation, capturing the interactions between reservoir dynamics and geomechanical responses. Verification against theoretical estimations based on linear poroelasticity confirms the model's capacity in representing reservoir background stress responses. However, the study reveals that relying solely on background stress states can underestimate or overestimate fault reactivation potential, emphasizing the importance of including localized stress perturbations such as differential compaction and stress redistribution. Applied to a fault (M1) inspired by the geological characteristics of the Groningen field, the model shows slip initiation at 2965 m depth with 16.0 MPa depletion, aligning with field observations where seismicity occurred at approximately 3 km depth after 15.8 MPa depletion. Parametric studies reveal: (1) inelastic reservoir compaction delays fault reactivation and mitigates fault slip by reducing stress concentration, (2) higher intermediate in-situ stress magnitudes decrease the Coulomb Failure Stress (CFS) increase rate and reduce fault slip, (3) larger fault offsets amplify shear stress near the offset zone, promoting earlier reactivation and longer rupture propagation, and (4) fault permeability significantly influences pressure diffusion, with low-permeability faults leading to sharper stress changes and earlier fault destabilization. These insights highlight the critical role of geological and mechanical parameters in fault reactivation and provide a predictive framework for mitigating induced seismicity risks.

Coupled geomechanical modeling↗

Role of Adjuvant Radiotherapy in Granulosa Cell Tumors of the Ovary

Purpose: To review the role of adjuvant radiotherapy (RT) in the outcome and recurrence patterns of granulosa cell tumors (GCTs) of the ovary. Methods and Materials: The records of all patients with GCTs referred to the Princess Margaret Hospital University Health Network between 1961 and 2006 were retrospectively reviewed. The patient, tumor, and treatment factors were assessed by univariate and multivariate analyses using disease-free survival (DFS) as the endpoint. Results: A total of 103 patients with histologically confirmed GCTs were included in the present study. The mean duration of follow-up was 100 months (range, 1-399). Of the 103 patients, 31 received adjuvant RT. A total of 39 patients developed tumor recurrence. The tumor size, incidence of intraoperative rupture, and presence of concurrent endometrial cancer were not significant risk factors for DFS. The median DFS was 251 months for patients who underwent adjuvant RT compared with 112 months for patients who did not (p = .02). On multivariate analysis, adjuvant RT remained a significant prognostic factor for DFS (p = .004). Of the 103 patients, 12 had died and 44 were lost to follow-up. Conclusion: Ovarian GCTs can be indolent, with patients achieving long-term survival. In our series, adjuvant RT resulted in a significantly longer DFS. Ideally, randomized trials with long-term follow-up are needed to define the role of adjuvant RT for ovarian GCTs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Biodistribution and Toxicity Study of Cobalt Dichloride-N-Acetyl Cysteine in an Implantable MRI Marker for Prostate Cancer Treatment

Purpose: C4, a cobalt dichloride-N-acetyl cysteine complex, is being developed as a positive-signal magnetic resonance imaging (MRI) marker to localize implanted radioactive seeds in prostate brachytherapy. We evaluated the toxicity and biodistribution of C4 in rats with the goal of simulating the systemic effects of potential leakage from C4 MRI markers within the prostate. Methods and Materials: 9-μL doses (equivalent to leakage from 120 markers in a human) of control solution (0.9% sodium chloride), 1% (proposed for clinical use), and 10% C4 solution were injected into the prostates of male Sprague-Dawley rats via laparotomy. Organ toxicity and cobalt disposition in plasma, tissues, feces, and urine were evaluated. Results: No C4-related morbidity or mortality was observed in the biodistribution arm (60 rats). Biodistribution was measurable after 10% C4 injection: cobalt was cleared rapidly from periprostatic tissue; mean concentrations in prostate were 163 μg/g and 268 μg/g at 5 and 30 minutes but were undetectable by 60 minutes. Expected dual renal-hepatic elimination was observed, with percentages of injected dose recovered in tissues of 39.0 ± 5.6% (liver), >11.8 ± 6.5% (prostate), and >5.3 ± 0.9% (kidney), with low plasma concentrations detected up to 1 hour (1.40 μg/mL at 5-60 minutes). Excretion in urine was 13.1 ± 4.6%, with 3.1 ± 0.54% recovered in feces by 24 hours. In the toxicity arm, 3 animals died in the control group and 1 each in the 1% and 10% groups from surgical or anesthesia-related complications; all others survived to scheduled termination at 14 days. No C4-related adverse clinical signs or organ toxicity were observed. Conclusion: C4-related toxicity was not observed at exposures at least 10-fold the exposure proposed for use in humans. These data demonstrating lack of systemic toxicity with dual routes of elimination in the event of in situ rupture suggest that C4 warrants further investigation as an MRI marker for prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗