Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PICO-LON project to search for cosmic dark matter

The dark matter search project PICO-LON has been started. Thin and wide area NaI(Tl) scintillator is the promising detector system to study the properties of dark matter particle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laboratory Studies of Lead Removal from Liquid Scintillator in Preparation for KamLAND's Low Background Phase

The removal of Radon induced Lead from liquid scintillator was extensively studied in preparation for KamLAND's low background phase. This work presents the results from laboratory experiments performed at the University of Alabama and their implications for KamLAND and future low background experiments using carbon based liquid scintillator. It was observed that distillation was the most effective purification procedure and that one must consider a non-polar and non-ionic component of Lead in order to reach the levels of radio-purity required for these new class of ultra-low background experiments.

36 MATERIALS SCIENCE↗

Effect of eccentricity on searches for gravitational waves from coalescing compact binaries in ground-based detectors

Inspiralling compact binaries are expected to circularize before their gravitational-wave signals reach the sensitive frequency band of ground-based detectors. Current searches for gravitational waves from compact binaries using the LIGO and Virgo detectors therefore use circular templates to construct matched filters. Binary formation models have been proposed which suggest that some systems detectable by the LIGO-Virgo network may have non-negligible eccentricity. We investigate the ability of the restricted 3.5 post-Newtonian order TaylorF2 template bank, used by LIGO and Virgo to search for gravitational waves from compact binaries with masses M{<=}35M{sub {center_dot},} to detect binaries with nonzero eccentricity. We model the gravitational waves from eccentric binaries using the x-model post-Newtonian formalism proposed by Hinder et al.[I. Hinder, F. Hermann, P. Laguna, and D. Shoemaker, arXiv:0806.1037v1]. We find that small residual eccentricities (e{sub 0} < or approx. 0.05 at 40 Hz) do not significantly affect the ability of current LIGO searches to detect gravitational waves from coalescing compact binaries with total mass 2M{sub {center_dot}<}M<15M{sub {center_dot}.} For eccentricities e{sub 0} > or approx. 0.1, the loss in matched filter signal-to-noise ratio due to eccentricity can be significant and so templates which include eccentric effects will be required to perform optimal searches for such systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All-sky search for gravitational-wave bursts in the first joint LIGO-GEO-Virgo run

We present results from an all-sky search for unmodeled gravitational-wave bursts in the data collected by the LIGO, GEO 600 and Virgo detectors between November 2006 and October 2007. The search is performed by three different analysis algorithms over the frequency band 50-6000 Hz. Data are analyzed for times with at least two of the four LIGO-Virgo detectors in coincident operation, with a total live time of 266 days. No events produced by the search algorithms survive the selection cuts. We set a frequentist upper limit on the rate of gravitational-wave bursts impinging on our network of detectors. When combined with the previous LIGO search of the data collected between November 2005 and November 2006, the upper limit on the rate of detectable gravitational-wave bursts in the 64-2048 Hz band is 2.0 events per year at 90% confidence. We also present event rate versus strength exclusion plots for several types of plausible burst waveforms. The sensitivity of the combined search is expressed in terms of the root-sum-squared strain amplitude for a variety of simulated waveforms and lies in the range 6x10{sup -22} Hz{sup -1/2} to 2x10{sup -20} Hz{sup -1/2}. This is the first untriggered burst search to use data from the LIGO and Virgo detectors together, and the most sensitive untriggered burst search performed so far.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental demonstration of higher-order Laguerre-Gauss mode interferometry

The compatibility of higher-order Laguerre-Gauss (LG) modes with interferometric technologies commonly used in gravitational wave detectors is investigated. In this paper, we present the first experimental results concerning the performance of the LG{sub 33} mode in optical resonators. We show that the Pound-Drever-Hall error signal for a LG{sub 33} mode in a linear optical resonator is identical to that of the more commonly used LG{sub 00} mode, and demonstrate the feedback control of the resonator with a LG{sub 33} mode. We succeeded to increase the mode purity of a LG{sub 33} mode generated using a spatial-light modulator from 51% to 99% upon transmission through a linear optical resonator. We further report the experimental verification that a triangular optical resonator does not transmit helical LG modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal noise in advanced gravitational wave interferometric antennas: A comparison between arbitrary order Hermite and Laguerre Gaussian modes

We study the thermal noise caused by mechanical or thermomechanical dissipation in mirrors of interferometric gravitational wave antennas. We give relative figures of merit for arbitrary Hermite-Gauss or Laguerre-Gauss optical beams regarding the Brownian and thermoelastic noises (substrate and coating) in the infinite mirror approximation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of massive perturbers on extreme mass-ratio inspiral waveforms

Extreme mass-ratio inspirals, in which a stellar-mass object orbits a supermassive black hole, are prime sources for space-based gravitational wave detectors because they will facilitate tests of strong gravity and probe the spacetime around rotating compact objects. In the last few years of such inspirals, the total phase is in the millions of radians and details of the waveforms are sensitive to small perturbations. We show that one potentially detectable perturbation is the presence of a second supermassive black hole within a few tenths of a parsec. The acceleration produced by the perturber on the extreme mass-ratio system produces a steady drift that causes the waveform to deviate systematically from that of an isolated system. If the perturber is a few tenths of a parsec from the extreme mass-ratio system (plausible in as many as a few percent of cases) higher derivatives of motion might also be detectable. In that case, the mass and distance of the perturber can be derived independently, which would allow a new probe of merger dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma Detector Response and Analysis Software - Detector Response Function

GADRAS-DRF uses a Detector Response Function (DRF) to compute the response of gamma-ray detectors incident radiation. The application includes provision for plotting measured and computed spectra and for characterizing detector response parameters based on measurements of a series of calibration sources (e.g., Ba-133, Cs-137, Co-60, and Th-228). An application program interface enables other programs to access the dynamic-link library that is used to compute spectra.

Source record↗

BNLs Synchrotron-radiation Research Hub for Characterizing Detection Materials and Devices for the NA-22 Community

The goal of this project is to obtain and characterize scintillators, emerging- and commercial-compoundsemiconductor radiation- detection materials and devices provided by vendors and research organizations. The focus of our proposed research is to clarify the role of the deleterious defects and impurities responsible for the detectors' non-uniformity in scintillating crystals, commercial semiconductor radiation-detector materials, and in emerging R&D ones. Some benefits of this project addresses the need for fabricating high-performance scintillators and compound-semiconductor radiation-detectors with the proven potential for large-scale manufacturing. The findings help researchers to resolve the problems of non-uniformities in scintillating crystals, commercial semiconductor radiation-detector materials, and in emerging R&D ones.

36 MATERIALS SCIENCE↗

Degradation of 81 keV 133Xe Gamma-Rays into the 31 keV X-Ray Peak in CsI Scintillators

ABSTRACT Pacific Northwest National Laboratory uses beta-gamma coincidence detectors in a number of xenon sampling and/or measurement systems to enable simultaneous, sensitive measurements of 131Xe, 133Xe, 133mXe, and 135Xe for treaty monitoring applications. In recent years, a new style of beta-gamma detector was developed to improve upon the detector module used in the Automated Radioxenon Sampler/Analyzer. The results of an MCNP5 Monte Carlo simulation of the new detector cell are presented, with particular emphasis on the identification of an energy deposition sequence with the potential to introduce significant error into the detector efficiency calibration. This sequence occurs when an 81 keV gamma from 133Xe is absorbed in an inactive region of the CsI(Na) scintillator, followed by emission of a 31 keV x-ray from cesium (or possibly a 28.5 keV x-ray from iodine). These x-rays add excess counts into the 31 keV peak observed in the decay of 133Xe. The impact of this effect on different efficiency calibration techniques is discussed.

133Xe, CsI Scintillators↗

Scintilla European project, the successful research results

The Scintilla FP7 project is ended in December 2014, the fruitful results of 3 years development and tests will be presented. SCINTILLA offers the capacity to finding a reliable alternative to Helium-3 based detection systems since the gas which is predominantly used in nuclear safeguards and security applications has now become very expensive, rare and nearly unavailable. SCINTILLA benchmarks results are based on international standards. Radiation Portal tests were carried out at the Joint Research Centre (JRC) in Ispra (Italy). The scintilla project addresses few mains issues. The first is to develop neutron detectors for Radiation Portal Monitor (RPM) and the second is the need of new wearable integrated solutions for Spectrometric Personal Radiation Monitor (SPRM). The partners which provide technical systems of the scintilla project are INFN-ANSALDO, CEA, SYMETRICA and SAPHYMO. For RPM, the objective is to find reliable alternatives to Helium-3 historical neutron detector and provide technical solutions which cope with tests for reliable mobile and cost effective. For Spectrometric Personal Radiation Monitor (SPRM), SCINTILLA is innovating in technology areas that offer complementary capabilities for detecting and identifying gamma, Two CZT (Cadmium Zinc Telluride) addressing contexts of used by first responder technologies, one is a wearable detector and the second is a gamma camera complemented by advanced image processing technologies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

CEPS – A Compact Electron-Proton Spectrometer

Small mass/low-power sensors are needed for autonomous Moon/Mars surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. Typical space weather sensors are at least an order of magnitude higher in mass than is expected from Timepix-based devices and are deployed on robotic assets away from human crews. High fidelity measurements at the crew location and subsequent ability are needed to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.​ The aim of this project is the development of compact, low power space weather sensors for crew protection based on the combination of AES flight heritage Timepix hardware with novel CdTe (Cadmium Telluride) sensors. CdTe technology has only recently matured to a point where it can be reliably used with Timepix detectors. These detectors will be able to measure electron spectra in an energy range relevant to the RELEASE model, which is used operationally by NASA to provide crew early warning of Solar Energetic Particle Events as well as protons in the energy ranges relevant to human health allowing for event ‘nowcasting’ and total event crew dose prediction. Compared to existing solutions these detectors will be compact enough to travel with crew, providing a significant advantage to space environment situation awareness. Project results indicate that CdTe-based Timepix sensors respond well to energetic electrons, and particle tracks are sufficiently distinct to be able to measure in a mixed radiation field. Detector response functions were developed for both electrons and protons. Measurement results showed response to both electrons and protons in the energy range of interest for human space flight.

Radiation↗