Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Apollo 15 Mission Report

A detailed discussion is presented of the Apollo 15 mission, which conducted exploration of the moon over longer periods, greater ranges, and with more instruments of scientific data acquisition than previous missions. The topics include trajectory, lunar surface science, inflight science and photography, command and service module performance, lunar module performance, lunar surface operational equipment, pilot's report, biomedical evaluation, mission support performance, assessment of mission objectives, launch phase summary, anomaly summary, and vehicle and equipment descriptions. The capability of transporting larger payloads and extending time on the moon were demonstrated. The ground-controlled TV camera allowed greater real-time participation by earth-bound personnel. The crew operated more as scientists and relied more on ground support team for systems monitoring. The modified pressure garment and portable life support system provided better mobility and extended EVA time. The lunar roving vehicle and the lunar communications relay unit were also demonstrated.

Source record↗

Inflatable Pole

Lightweight, portable tool reaches object at height or across gap. Extends reach up to 20 feet (6 meters). When not in use, tool collapses to 3 to 5 percent of its inflated length. Developed for use as self-rescue device by astronaut who becomes untethered outside spacecraft: astronaut uses pole to reach grapple on spacecraft and pull to it. Useful on Earth as rescue device or in performing routine tasks like changing high light bulb without ladder. When task with inflatable pole completed, operator opens vent valve to deflate tube. Operator then opens gun, removes fabric cover, and repacks tube.

Swan, Scott A.↗

Sensing Super-position: Visual Instrument Sensor Replacement

The coming decade of fast, cheap and miniaturized electronics and sensory devices opens new pathways for the development of sophisticated equipment to overcome limitations of the human senses. This project addresses the technical feasibility of augmenting human vision through Sensing Super-position using a Visual Instrument Sensory Organ Replacement (VISOR). The current implementation of the VISOR device translates visual and other passive or active sensory instruments into sounds, which become relevant when the visual resolution is insufficient for very difficult and particular sensing tasks. A successful Sensing Super-position meets many human and pilot vehicle system requirements. The system can be further developed into cheap, portable, and low power taking into account the limited capabilities of the human user as well as the typical characteristics of his dynamic environment. The system operates in real time, giving the desired information for the particular augmented sensing tasks. The Sensing Super-position device increases the image resolution perception and is obtained via an auditory representation as well as the visual representation. Auditory mapping is performed to distribute an image in time. The three-dimensional spatial brightness and multi-spectral maps of a sensed image are processed using real-time image processing techniques (e.g. histogram normalization) and transformed into a two-dimensional map of an audio signal as a function of frequency and time. This paper details the approach of developing Sensing Super-position systems as a way to augment the human vision system by exploiting the capabilities of the human hearing system as an additional neural input. The human hearing system is capable of learning to process and interpret extremely complicated and rapidly changing auditory patterns. The known capabilities of the human hearing system to learn and understand complicated auditory patterns provided the basic motivation for developing an image-to-sound mapping system.

Maluf, David A.↗

Sensing Super-Position: Human Sensing Beyond the Visual Spectrum

The coming decade of fast, cheap and miniaturized electronics and sensory devices opens new pathways for the development of sophisticated equipment to overcome limitations of the human senses. This paper addresses the technical feasibility of augmenting human vision through Sensing Super-position by mixing natural Human sensing. The current implementation of the device translates visual and other passive or active sensory instruments into sounds, which become relevant when the visual resolution is insufficient for very difficult and particular sensing tasks. A successful Sensing Super-position meets many human and pilot vehicle system requirements. The system can be further developed into cheap, portable, and low power taking into account the limited capabilities of the human user as well as the typical characteristics of his dynamic environment. The system operates in real time, giving the desired information for the particular augmented sensing tasks. The Sensing Super-position device increases the image resolution perception and is obtained via an auditory representation as well as the visual representation. Auditory mapping is performed to distribute an image in time. The three-dimensional spatial brightness and multi-spectral maps of a sensed image are processed using real-time image processing techniques (e.g. histogram normalization) and transformed into a two-dimensional map of an audio signal as a function of frequency and time. This paper details the approach of developing Sensing Super-position systems as a way to augment the human vision system by exploiting the capabilities of Lie human hearing system as an additional neural input. The human hearing system is capable of learning to process and interpret extremely complicated and rapidly changing auditory patterns. The known capabilities of the human hearing system to learn and understand complicated auditory patterns provided the basic motivation for developing an image-to-sound mapping system. The human brain is superior to most existing computer systems in rapidly extracting relevant information from blurred, noisy, and redundant images. From a theoretical viewpoint, this means that the available bandwidth is not exploited in an optimal way. While image-processing techniques can manipulate, condense and focus the information (e.g., Fourier Transforms), keeping the mapping as direct and simple as possible might also reduce the risk of accidentally filtering out important clues. After all, especially a perfect non-redundant sound representation is prone to loss of relevant information in the non-perfect human hearing system. Also, a complicated non-redundant image-to-sound mapping may well be far more difficult to learn and comprehend than a straightforward mapping, while the mapping system would increase in complexity and cost. This work will demonstrate some basic information processing for optimal information capture for headmounted systems.

Maluf, David A.↗

Portable Health Algorithms Test System

A document discusses the Portable Health Algorithms Test (PHALT) System, which has been designed as a means for evolving the maturity and credibility of algorithms developed to assess the health of aerospace systems. Comprising an integrated hardware-software environment, the PHALT system allows systems health management algorithms to be developed in a graphical programming environment, to be tested and refined using system simulation or test data playback, and to be evaluated in a real-time hardware-in-the-loop mode with a live test article. The integrated hardware and software development environment provides a seamless transition from algorithm development to real-time implementation. The portability of the hardware makes it quick and easy to transport between test facilities. This hard ware/software architecture is flexible enough to support a variety of diagnostic applications and test hardware, and the GUI-based rapid prototyping capability is sufficient to support development execution, and testing of custom diagnostic algorithms. The PHALT operating system supports execution of diagnostic algorithms under real-time constraints. PHALT can perform real-time capture and playback of test rig data with the ability to augment/ modify the data stream (e.g. inject simulated faults). It performs algorithm testing using a variety of data input sources, including real-time data acquisition, test data playback, and system simulations, and also provides system feedback to evaluate closed-loop diagnostic response and mitigation control.

Melcher, Kevin J.↗

Design and Assembly of an Integrated Metabolic Heat Regenerated Temperature Swing Adsorption (MTSA) Subassembly Engineering Development Unit

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Ice Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously each the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU to the future flight unit are considered.

Padilla, Sebastian A.↗

Design and Assembly of an Integrated Metabolic Heat Regenerated Temperature Swing Adsorption (MTSA) Subassembly Engineering Development Unit

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal and carbon dioxide (CO2) control for a Portable Life Support System (PLSS), as well as water recycling. The core of the MTSA technology is a sorbent bed that removes CO2 from the PLSS ventilation loop gas via a temperature swing. A Condensing Icing Heat eXchanger (CIHX) is used to warm the sorbent while also removing water from the ventilation loop gas. A Sublimation Heat eXchanger (SHX) is used to cool the sorbent. Research was performed to explore an MTSA designed for both lunar and Martian operations. Previously the sorbent bed, CIHX, and SHX had been built and tested individually on a scale relevant to PLSS operations, but they had not been done so as an integrated subassembly. Design and analysis of an integrated subassembly was performed based on this prior experience and an updated transient system model. Focus was on optimizing the design for Martian operations, but the design can also be used in lunar operations. An Engineering Development Unit (EDU) of an integrated MTSA subassembly was assembled based on the design. Its fabrication is discussed. Some details on the differences between the as-assembled EDU and the future flight unit are considered.

Padilla, Sebastian A.↗

Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Broad Distribution of Local Polar States Generates Large Electrothermal Properties in Pb-Free Relaxor Ferroelectrics

Electrothermal energy conversion provides attractive solutions for global energy management, such as energy harvesting from waste heat using pyroelectric energy conversion (PEC) and efficient cooling of portable electronics or data servers using the electrocaloric effect. Relaxor ferroelectrics are attractive for electrothermal energy conversion because of their large pyroelectric coefficients over a wide temperature range. Although Pb-based relaxors are well-known, toxicity concerns have mandated the intense search for Pb-free alternatives. Here, we engineered (Ba,Ca)TiO 3 -based relaxors based on a multisite doping strategy, which show promising electrothermal performance, viz. a maximum PEC efficiency of 14% and electrocaloric refrigeration capacity of 115 J/kg. Using local-scale structural analysis, we provide an atomistic model for large electrothermal properties in the newly designed Pb-free ferroelectrics, whereby a temperature-independent continuous distribution of cation displacement directions creates easy pathways for microscopic polarization reorientation. This research provides key structural insight for future atomic-scale engineering of environmentally sustainable ferroelectrics in energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchronized Wireless Measurement of High-Voltage Power System Frequency Using Mobile Embedded Systems

This paper focuses on synchronized wireless measurement of high-voltage (HV) power system frequency using mobile embedded systems (MESs) integrated with a wireless electric field sensor (WEFS). Unlike traditional synchronized frequency measurement devices, which rely on potential transformers and current transformers physically connected to system elements, a WEFS is used to realize wireless signal acquisition in the vicinity of any HV apparatus. The MES performs real-time frequency estimation using a recursive discrete Fourier transform based algorithm. Network time protocol (NTP) is used for time synchronization, increasing the system flexibility by eliminating global positioning system reliance. An NTP-based synchronized sampling control method is proposed and implemented in MES to compensate the sampling time error caused by local time drift and division residue. The proposed system has the advantages of portability and lower cost, making it highly accessible and useful for a wide array of synchronized frequency measurement applications. Experiment results verify the accuracy and effectiveness of the proposed system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing the vestibular system and the central nervous system, responsible for coordinating head and eye movements, are adapted to microgravity and must re-adapt to the gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. Dynamic visual acuity (DVA) is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is lightweight and easily portable for quick deployment in the field. The base of the chair is spring-loaded and allows for manual oscillation of the subject. Using a metronome, the chair is vertically oscillated plus or minus 2 cm at 2 Hz by an operator, to simulate walking. While the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous response of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. Dynamic visual acuity measures will be taken prior to flight (typically L-180, L-90, and L-60) and up to eight times after landing, including up to 3 times on R plus 0. Follow up measurements will be taken at R plus 1 (approximately 36 hours after landing). Long-duration International Space Station crewmembers will be tested once at the refueling stop in Europe and once again upon return to Johnson Space Center. In addition to DVA, subjective ratings of motion sickness will be recorded throughout the testing. Using the chair as a portable and reliable way to test DVA, we aim to test returning astronauts to assess the amount of retinal slip that they experience. By comparing these measurements to their motion sickness scores (using a scale of 1 to 20 where 20 is vomiting), we will correlate the amount of retinal slip to the level of motion sickness experienced. In addition to testing this in returning astronauts, we will perform ground-based studies to determine the effectiveness of stroboscopic goggles in reducing retinal slip and improving DVA. Finally, we will employ stroboscopic goggles in the field to astronauts experiencing high levels of motion sickness to minimize retinal slip and reduce their symptoms.

Rosenberg, M.J.F↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Sensitive Amino Acid Composition and Chirality Analysis with the Mars Organic Analyzer (MOA)

Detection of life on Mars requires definition of a suitable biomarker and development of sensitive yet compact instrumentation capable of performing in situ analyses. Our studies are focused on amino acid analysis because amino acids are more resistant to decomposition than other biomolecules, and because amino acid chirality is a well-defined biomarker. Amino acid composition and chirality analysis has been previously demonstrated in the lab using microfabricated capillary electrophoresis (CE) chips. To analyze amino acids in the field, we have developed the Mars Organic Analyzer (MOA), a portable analysis system that consists of a compact instrument and a novel multi-layer CE microchip.

Skelley, Alison M.↗

High-Sensitivity DNA Aptasensors for Detecting Salivary Biomarker S100A7 in Heart Failure

Early detection of heart failure (HF) is vital for improving patient outcomes, lowering hospital readmission rates, and enabling prompt treatment. We present the first high-affinity DNA aptamer for the salivary HF biomarker S100A7 and its application in highly sensitive, noninvasive diagnostic tests. Iterative truncation of the initial 82-nt aptamer (17–82) produced a 43-nt core (17–43) with a binding affinity of 27 nM, which was further enhanced to 5.5 nM through dimerization. Biochemical and mutational studies confirmed that 17–43 adopts a G-quadruplex structure, which is essential for S100A7 recognition and resistance to enzymatic degradation in human saliva. Incorporating 17–43 into sandwich aptamer-ELISA and hybrid aptamer–antibody ELISA assays allowed detection of recombinant S100A7 in human saliva with limits of detection (LOD) of 7.4 ng mL–1 (0.6 nM) and 29 pg/mL (2.2 pM), respectively-outperforming commercial immunoassays in both sensitivity and dynamic range. The hybrid assay maintained its full performance after 2.5 months of room temperature storage. Additionally, a biolayer interferometry (BLI) sensor with 17–43 quantified S100A7 in patient saliva (n = 3), achieving a LOD of 3.2 ng mL–1 (0.3 nM) with a total assay time of less than 20 min. The aptamer’s stability, high specificity, and versatility across biosensing platforms establish it as a promising tool for noninvasive heart failure diagnostics, laying the groundwork for portable aptamer-based biosensors for multiplexed monitoring of HF biomarkers.

DNA aptamer↗

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products. Dual-use applications can include battery chargers and remote power supplies for consumer electronics products such as portable telephones/beepers, portable radios, CD players, dashboard radar detectors, remote walkway lighting, etc.

Dinetta, L. C.↗

Mechanical Prototyping and Manufacturing Internship

The internship was located at the Johnson Space Center (JSC) Innovation Design Center (IDC), which is a facility where the JSC workforce can meet and conduct hands-on innovative design, fabrication, evaluation, and testing of ideas and concepts relevant to NASA's mission. The tasks of the internship included mechanical prototyping design and manufacturing projects in service of research and development as well as assisting the users of the IDC in completing their manufacturing projects. The first project was to manufacture hatch mechanisms for a team in the Systems Engineering and Project Advancement Program (SETMAP) hexacopter competition. These mechanisms were intended to improve the performance of the servomotors and offer an access point that would also seal to prevent cross-contamination. I also assisted other teams as they were constructing and modifying their hexacopters. The success of this competition demonstrated a proof of concept for aerial reconnaissance and sample return to be potentially used in future NASA missions. I also worked with Dr. Kumar Krishen to prototype an improved thermos and a novel, portable solar array. Computer-aided design (CAD) software was used to model the parts for both of these projects. Then, 3D printing as well as conventional techniques were used to produce the parts. These prototypes were then subjected to trials to determine the success of the designs. The solar array is intended to work in a cluster that is easy to set up and take down and doesn't require powered servomechanisms. It could be used terrestrially in areas not serviced by power grids. Both projects improve planetary exploration capabilities to future astronauts. Other projects included manufacturing custom rail brackets for EG-2, assisting engineers working on underwater instrument and tool cases for the NEEMO project, and helping to create mock-up parts for Space Center Houston. The use of the IDC enabled efficient completion of these projects at significantly reduced cost. I acquired and improved manufacturing and prototyping skills during my tour including learning about a CAD (Computer-Aided Design) program called Creo (Creo Parametric; design software), gaining valuable conventional machining experience with lathes, CNC (Computer Numerical Control) milling machines and various other tools, and improving my engineering project communication and collaboration skills. The internship also allowed me to better understand operations at NASA. I plan to work in the aerospace industry or do academic research benefitting space science and exploration, and this internship experience will enable me to have insight into manufacturing processes for research and development.

Grenfell, Peter↗

Application of Multivariate Data Analysis Techniques for the Portable Isotopic Neutron Spectroscopy system

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical compounds non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS systems have been successfully deployed around the world to identify chemical munitions and containers. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with the probabilistic decision tree (PDT). Gamma-ray peak analyses, however, require knowledge of pre-selected gamma-ray peaks whose energies, intensities, and origins are well studied, and some peaks might be excluded from the decision making processes due to lack of current nuclear data. In contrast, Multivariate Analysis (MVA) treats a whole gamma-ray spectrum as a collection of multiple variables or a pattern. The effectiveness of chemical identification algorithm is determined by the availability of a wide range of data to train an algorithm to identify chemical fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to combine such a database with the principle of multivariate statistics. Therefore, in parallel with the current decision tree algorithm, an MVA-based chemical identification algorithm was developed as an independent verification of the current results. The Principal Component Analysis (PCA) method was adopted to build an MVA-based identification algorithm, using the collected field data to refine and validate the algorithm. A benchmarking study of the MVA-based algorithm’s performance was conducted alongside the current algorithm, with the results presented and discussed in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human performance benefits gained by dynamic instructions compared to smart PDFs

Human performance benefits gained by dynamic instructions compared to smart PDFs In recent years multiple nuclear utilities have deployed an electronic work management solution to replace the traditional paper-based processes. There are many benefits of electronic work management solutions compared to paper processes, such as a more streamlined review and approval process of work packages and a better way to track and resolve any potential bottlenecks causing delays in the review process. These benefits have been recognized where electronic work management solutions have been successfully deployed. However the utilities also hoped the new solution would help the field worker conduct his/her job more efficiently, correctly, and safely. Unfortunately, the industry is now realizing that the deployed solutions did not fully help them reach that goal. The electronic work management solutions present the work instructions as an electronic copy (i.e., a portable document format (PDF)) of the paper instruction. The PDF versions used in these electronic work management solutions have some ability for data input, notes, and mark-ups, but are unable to provide many additional benefits compared to using paper. In fact, conducting work using a PDF on a tablet can be more cumbersome than with a paper instruction. For example, flipping back and forth in a paper instruction can be time consuming, but it is not at all as frustrating as scrolling back and forth on a tablet or continuously having to navigate between tabs. The researchers at Idaho National Laboratory (INL) approached the next step beyond smart PDFs from a human factors perspective. In close collaboration with multiple utilities they investigated how to present instruction content and how to design the interaction with the instruction to improve the workers performance and efficiency. Their solution is a dynamic presentation of the instruction that guides the worker through the correct path as well as ensuring the worker is on the correct component. The solution also automatically validates input and provides guidance if unexpected conditions are identified. A well-designed solution has the opportunity to vastly reduce the risk of human errors in the field, such as preventing actions on incorrect component or unintentionally skipping steps. The human factors researchers at INL leveraged their expertise, existing human performance tools, and a great amount of involvement from field workers in multiple utilities to develop and evaluate design concepts that will provide the human performance and efficiency benefits that the electronic work management solutions fall short to deliver. This paper will describe in detail how these new design concepts improve human performance.

47 OTHER INSTRUMENTATION↗