Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Continuous Monitoring and On-line Analysis of Operational Dose Rates: Tools to Further Mitigate Radiation Risks

Along with passive and active engineering and administrative controls usually implemented in radiation protection programs at different facilities, continuous monitoring and on-line analysis of data measured by the radiation detectors at the workplace and in the environment can be considered as an additional tool used to further mitigate radiation risks. Many monitoring systems on the market today allow connecting radiation area monitors into a network, and reading and accumulating data continuously in a database. The point of this presentation is to bring attention to the fact that such accumulated information can be analyzed and used in many respects to improve reliability and functionality of the monitoring and control systems. A simple time history of background readings from a radiation detector can be used to evaluate the stability of the detector performance. Data recorded during normal facility operations may serve to establish a pattern of acceptable dose rates in such detector and allow to better detect off-normal and unstable modes of the facility operation before they reach hardware trip levels. Facility operators and users may utilize such monitoring systems to optimize operations and minimize their radiological impact. Implementation and examples of use of the RADMON radiation monitoring and data analysis system at Jefferson Lab is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of vertical stability for negative triangularity pilot plants

Abstract Negative triangularity (NT) tokamak configurations may be more susceptible to magneto-hydrodynamic instability, posing challenges for recent reactor designs centered around their favorable properties, such as improved confinement and operation free of edge-localized modes. In this work, we assess the vertical stability of plasmas with NT shaping and develop potential reactor solutions. When coupled with a conformal wall, NT equilibria are confirmed to be less vertically stable than equivalent positive triangularity (PT) configurations. Unlike PT, their vertical stability is degraded at higher poloidal beta. Furthermore, improvements in vertical stability at low aspect ratio do not translate to the NT geometry. NT equilibria are stabilized in PT vacuum vessels due to the increased proximity of the plasma and the wall on the outboard side, but this scenario is found to be undesirable due to reduced vertical gaps which give less spatial margin for control recovery. Instead, we demonstrate that informed positioning of passively conducting plates can lead to improved vertical stability in NT configurations on par with stability metrics expected in PT scenarios. An optimal setup for passive plates in highly elongated NT devices is presented, where plates on the outboard side of the device reduce vertical instability growth rates to 16% of their baseline value. For lower target elongations, integration of passive stabilizers with divertor concepts can lead to significant improvements in vertical stability. Plates on the inboard side of the device are also uniquely enabled in NT geometries, providing opportunity for spatial separation of vertical stability coils and passive stabilizers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-efficiency, air-stable manganese–iron oxide nanoparticle-pigmented solar selective absorber coatings toward concentrating solar power systems operating at 750 °C

Solar selective absorber coating with long-term thermal stability at high temperatures ≥750 °C in air is an important component to reduce the levelized cost of energy (LCOE) of concentrating solar power (CSP) systems toward 50% power efficiency and dispatchable solar electricity. Conventionally, solar spectral selectivity requires multilayer-interference coatings implemented by stringently controlled vacuum deposition, and these coatings degrade significantly at >700 °C in air. Herein, we established a quantitative design approach and demonstrated a proof-of-concept air-stable, manganese–iron oxide nanoparticle (NP)-pigmented solar selective coatings with a high solar absorptance of ~93%, a relatively low thermal emittance of ~52%, and an optical-to-thermal energy conversion efficiency >89% under 1,000× solar concentration at 750 °C toward Generation 3 CSP systems. These coatings demonstrate spectral selectivity using cost-effective spray coating approach, a notable improvement over conventional vacuum-deposited, multilayer solar selective coatings for low-cost, high-efficiency solar thermal receivers. In contrast to the thermal degradation of spectrally non-selective benchmark Pyromark 2500 coatings at 750 °C in air, the solar absorptance of the MnFe 2 O 4 -pigmented coatings on stainless steel 310 (SS 310) substrates is increased to ~92.9% and the optical-to-thermal energy conversion efficiency is improved to 89.7% after serving at 750 °C in air for 700 h. X-ray diffraction results reveal that this improvement is due to the transformation of MnFe 2 O 4 NPs into more thermodynamically stable, non-stoichiometric manganese-rich manganese ferrite and iron-rich manganese–iron oxide phases after 500 h aging at 750 °C. For >1,000 h-endurance testing at 750 °C in air and the subsequent 19 day-night thermal cycling between 750 °C (12 h/cycle) and 25 °C (12 h/cycle) on SS 310 substrates, the thermal degradation is mainly due to the CrO x microflake formation from SS 310 substrates rather than the coatings, which can be suppressed by preoxidizing the surface of SS 310. With lower emittance matrix material and further optimization of pigment NP stoichiometry, concentration, and coating thickness, it is promising to achieve an optimized thermal efficiency ≥92.5% with long-term thermal stability at 750 °C for Generation 3 CSP systems.

14 SOLAR ENERGY↗

Time-resolved measurement of neutron energy isotropy in a sheared-flow-stabilized Z pinch

Previous measurements of neutron energy using fast plastic scintillators while operating the Fusion Z Pinch Experiment (FuZE) constrained the energy of any yield-producing deuteron beams to less than 4.65 keV. FuZE has since been operated at increasingly higher input power, resulting in increased plasma current and larger fusion neutron yields. A detailed experimental study of the neutron energy isotropy in these regimes applies more stringent limits to possible contributions from beam-target fusion. The FuZE device operated at -25 kV charge voltage has resulted in average plasma currents of 370 kA and D–D fusion neutron yields of $4\times10^7 \pm 4\times10^6$ neutrons per discharge. Measurements of the neutron energy isotropy under these operating conditions demonstrates the energy of deuteron beams is less than $7.4 \pm 5.6^\mathrm{(stat)} \pm 3.7^\mathrm{(syst)}$ keV. Characterization of the detector response has reduced the number of free parameters in the fit of the neutron energy distribution, improving the confidence in the forward-fit method. Gamma backgrounds have been measured and the impact of these contributions on the isotropy results have been studied. Additionally, a time dependent measurement of the isotropy has been resolved for the first time, indicating increases to possible deuteron beam energies at late times. This suggests the possible growth of m = 0 instabilities at the end of the main radiation event but confirms that the majority of the neutron production exhibits isotropy consistent with thermonuclear origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive Model Reduction for Parareal in Time Method for Transient Stability Simulations

Real time or faster than real time simulation can enable system operators to foresee the effect of crucial contingencies on the power system dynamics and take timely actions to prevent system instability. Parareal in time method uses concurrent computations on different segments of the time domain of interest to speed up the dynamic simulations. This paper describes the application of an adaptive nonlinear model reduction method in improving computational speed of the Parareal solver. The proposed method adaptively switches between a hybrid system with selective linearization and a completely linear system based on the size of a disturbance. The functions in the hybrid system are linearized based on the electrical distance between specific generators and the area where disturbances originated. The proposed method is tested on the 327-machine 2383-bus Polish system.

Osipov, Denis↗

Unveiling the Mechanism of Mn Dissolution Through a Dynamic Cathode‐Electrolyte Interphase on LiMn2O4

Abstract Understanding the formation and evolution of the cathode‐electrolyte interphase (CEI), which forms at the interface between the cathode and electrolyte, is crucial for revealing degradation mechanisms in cathode materials, especially for developing strategies to stabilize the interphase in the strongly oxidizing conditions that evolve at high operating voltages in next‐generation Li‐ion batteries. However, The present understanding of the CEI is challenged by its complex and dynamic nature. In this work, near‐edge X‐ray absorption fine structure spectroscopy, electrochemical characterization, and reactive molecular dynamics simulations are combined to reveal a mechanism for CEI formation and evolution above model LiMn 2 O 4 (LMO) thin‐film electrodes in contact with conventional carbonate‐based electrolytes. It is found that Mn dissolution from LMO can be understood in terms of repetitive Mn 3 O 4 formation and dissolution behavior during cycling, which is closely connected to electrolyte decomposition and a key aspect of the CEI formation and growth. The behavior of the CEI in this model system offers detailed insight into the dynamic chemistry of the interphase, underscoring the important role of electrolyte composition and cathode surface structure in interphase degradation.

Ou, Wenhan↗

Mechanistic Insights into the Surface Instabilities of TiNb 2 O 7, a High‐Power Li‐Ion Anode

TiNb 2 O 7 (TNO) is a promising Li-ion battery anode for high-power applications, such as implantable medical devices and heavy-duty equipment. Hailed as being safe due to its elevated operating potential near 1.6 V, TNO has long been assumed to be highly stable in the carbonate-based electrolytes used in Li-ion batteries. Herein, all mechanisms occurring at the surface of both TNO and Nd-doped TNO are identified, and both materials in fact show significant gassing. CO 2 is even released at open circuit conditions, demonstrating the poor chemical stability of the material in the electrolyte even prior to battery operation. Such extreme instability is a critical safety concern. In addition, it was found that Ti dissolves from the surface of TNO particles at low voltage (below 1.4 V vs Li), and in fact deposits on the counter electrode. Ti further inside TNO particles then diffuses to the Ti-poor surface during discharge. Partial carbon-coating as a mitigating measure has also been tested and found to exacerbate these processes. The findings identify novel reactions occurring within TNO, and clearly highlight the need to stabilize the surfaces of TNO in order to prevent such aggressive deterioration at the surface of the particles.

25 ENERGY STORAGE↗

Energy conservative SBP discretizations of the acoustic wave equation in covariant form on staggered curvilinear grids

In this work, we develop a numerical method for solving the acoustic wave equation in covariant form on staggered curvilinear grids in an energy conserving manner. The use of a covariant basis decomposition leads to a rotationally invariant scheme that outperforms a Cartesian basis decomposition on rotated grids. The discretization is based on high order Summation-By-Parts (SBP) operators and preserves both symmetry and positive definiteness of the contravariant metric tensor. To improve accuracy and decrease computational cost, we also derive a modified discretization of the metric tensor that leads to a conditionally stable discretization. Bounds are derived that yield a point-wise condition that can be evaluated to check for stability of the modified discretization. This condition shows that the interpolation operators should be constructed such that their norm is close to one.

97 MATHEMATICS AND COMPUTING↗

Significance and complications of drilling fluid rheology in geothermal drilling: A review

The harsh downhole conditions of high pressure and high temperature (HPHT) encountered in geothermal wells make the drilling operation challenging. Drilling in such environments requires a special drilling mud formulation with high thermal stability and good rheological properties to fulfill the drilling fluid functions. Therefore, great efforts should be put into selecting the suitable drilling fluid, optimize and monitor the drilling fluid properties throughout drilling operations, and predicting its performance under downhole conditions. Rheological properties significantly impact many drilling parameters such as hole cleaning, fluid and wellbore stability, wellbore hydraulics, torque and drag, and other drilling issues. This paper discusses water-based drilling fluids' flow behavior under HPHT conditions and highlights the significance of fluid rheology in geothermal drilling. The common challenges and complications related to fluid rheology encountered in geothermal drilling are addressed in this paper, such as hole cleaning, wellbore hydraulics, and drilling fluid stability. This article also reviews the recent advances in drilling mud systems, rheology enhancement, and rheological properties measurements at surface and subsurface conditions. Furthermore, the rheology models of drilling fluid at elevated temperatures are reviewed to fully understand their flow behavior and establish a method for drilling engineers to optimize fluid formulations for geothermal drilling.

58 GEOSCIENCES↗

W7-X magnetic diagnostics: Rogowski coil performance for very long pulses

Stellerators can be operated without the need of significant plasma current for generation of poloidal magnetic field components. Wendelstein 7-X (W7-X) is optimized for stiff magnetic configurations by minimizing pressure driven currents, such as bootstrap and Pfirsch-Schlueter currents. In Addition to the largely reduced plasma currents, the HELIAS-type device is a low magnetic shear configuration required for magnetic boundary islands. However, the diverting magnetic field structure is already influenced by small net plasma currents. In particular, the W7-AS divertor results revealed a significant sensitivity of the X-point location with respect to favorable edge plasma states. Thus, a precise X-point control for W7-X is envisaged and, although expected net plasma currents range in the order of 10-100 kA only, stabilization by adaptive controllers is foreseen to an accuracy of about 1 kA. This stabilization should be reliable even after 2000 s of plasma operation. A precondition for achieving this is a reliable current detection. For this purpose, W7-X will be equipped with Rogowski of which the first has now been assembled onto one of the plasma vessel sectors. The integral performance and sensitivity inhomogeneities have been tested by employing the digital integrator of W7-X [A. Werner, Rev. Sci. Instrum. 77, 10E307 (2006)] and a cable energized with 200 A, representing the plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A switched state feedback law for the stabilization of LTI systems.

Inspired by prior work in the design of switched feedback controllers for second order systems, we develop a switched state feedback control law for the stabilization of LTI systems of arbitrary dimension. The control law operates by switching between two static gain vectors in such a way that the state trajectory is driven onto a stable n - 1 dimensional hyperplane (where n represents the system dimension). We begin by briefly examining relevant geometric properties of the phase portraits in the case of two-dimensional systems to develop intuition, and we then show how these geometric properties can be expressed as algebraic constraints on the switched vector fields that are applicable to LTI systems of arbitrary dimension. We then derive necessary and sufficient conditions to ensure stabilizability of the resulting switched system (characterized primarily by simple conditions on eigenvalues), and describe an explicit procedure for designing stabilizing controllers. We then show how the newly developed control law can be applied to the problem of minimizing the maximal Lyapunov exponent of the corresponding closed-loop state trajectories, and we illustrate the closed-loop transient performance of these switched state feedback controllers via multiple examples.

42 ENGINEERING↗

Sensitivity of Western U.S. power system dynamics to droughts compounded with fuel price variability

The energy sector is heavily dependent on surface water availability for reliable electricity generation. Power system operations are usually evaluated through system reliability and economic perspectives, with assumptions based on market prices and normal water availability. As natural gas technologies continue to dominate new thermal capacity, replacing retiring coal and nuclear generators, natural gas price stability becomes increasingly important and the impact of price volatility on grid operations must be understood. Here, we explore the range of Western Electricity Coordinating Council (WECC) regional power operations, which represents the electric interconnection over the western half of the continental United States, using a production cost model driven by different fuel prices and an integrated hydrology model to simulate historical water availability. Our results show system-wide operation costs increasing in drought years or when gas prices increase, as expected. In addition, we found those system-wide increases can be of the same magnitude. Regional analysis of the responses to compounded droughts and price volatility highlight differences in magnitude and direction depending on regional generation technology portfolios. The Pacific Northwest is most sensitive to drought conditions, Southern California is most sensitive to gas prices, and the Desert Southwest is sensitive to both with the same magnitude. This analysis motivates further research in combined hydrology and power system modeling to characterize regional dynamics and associated uncertainties across scales, which is an important underpinning for the development of more resilient energy and water systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid (Spanish Version)

This is the Spanish version of 'Greening the Grid - Integrating Variable Renewable Energy into the Grid: Key Issues'. To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, and Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Variable Renewable Energy - Russia

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future. This is a Russian-language translation of Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid, originally published in English in May 2015.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microstructure degradation of YSZ in Ni/YSZ anodes of SOFC operated in phosphine-containing fuels

The interaction of trace (ppm) phosphine with the nickel/yttria stabilized zirconia (YSZ) anode of commercial solid oxide fuel cells has been investigated and evaluated for both synthesis gas and hydrogen fuels in an effort to examine P–Y reactions. The Ni poisoning effects reported in literature were confirmed and degradation was examined by electrochemical methods and post-test microstructural and chemical analyses. The results indicate that P-induced degradation rates and mechanisms are fuel dependent and that degradation of cells operated in synthesis gas (syngas) with phosphine is more severe than that of cells operated in hydrogen with phosphine. As reported in published literature, a cell operated in syngas containing 10 ppm phosphine demonstrated significant microstructural degradation within the Ni phase, including formation of Ni–P phases concentrated on the outer layer of the anode and significant pitting corrosion in the Ni grains. In this research, a previously undetected YPO{sub 4} phase is observed at the YSZ/YSZ/Ni triple grain junctions located at the interface with the YSZ electrolyte. Tetragonal YSZ (t-YSZ) and cubic-YSZ (c-YSZ) domains with sizes of several tens of nanometers are also newly observed along the Ni/YSZ interface. These observations contrast with data obtained for a cell operated in dry hydrogen with phosphine, where no YPO{sub 4} phase is observed and the alternating t-YSZ and c-YSZ domains at the Ni/YSZ interface are smaller with typical sizes of 5–10 nm. The data imply that electrolyte attack by P is a potentially debilitating mode of degradation in SOFC anodes, and that the associated reaction mechanisms and rates are worthy of further examination.

30 DIRECT ENERGY CONVERSION↗

Overview of ten-year operation of the superconducting linear accelerator at the Spallation Neutron Source

The Spallation Neutron Source (SNS) has acquired extensive operational experience of a pulsed proton superconducting linear accelerator (SCL) as a user facility. Numerous lessons have been learned in its first 10 years operation to achieve a stable and reliable operation of the SCL. In this paper, an overview of the SNS SCL design, qualification of superconducting radio frequency (SRF) cavities and ancillary subsystems, an overview of the SNS cryogenic system, the SCL operation including SCL output energy history and downtime statistics, performance stability of the SRF cavities, efforts for SRF cavity performance recovery and improvement at the SNS, and maintenance activities for cryomodules are introduced.

43 PARTICLE ACCELERATORS↗