Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Off gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Partial Oxidation Gas Turbine for Power and Hydrogen Co-Production from Coal-Derived Fuel in Industrial Applications

The report presents a feasibility study of a new type of gas turbine. A partial oxidation gas turbine (POGT) shows potential for really high efficiency power generation and ultra low emissions. There are two main features that distinguish a POGT from a conventional gas turbine. These are associated with the design arrangement and the thermodynamic processes used in operation. A primary design difference of the POGT is utilization of a non?catalytic partial oxidation reactor (POR) in place of a conventional combustor. Another important distinction is that a much smaller compressor is required, one that typically supplies less than half of the air flow required in a conventional gas turbine. From an operational and thermodynamic point of view a key distinguishing feature is that the working fluid, fuel gas provided by the OR, has a much higher specific heat than lean combustion products and more energy per unit mass of fluid can be extracted by the POGT expander than in the conventional systems. The POGT exhaust stream contains unreacted fuel that can be combusted in different bottoming ycle or used as syngas for hydrogen or other chemicals production. POGT studies include feasibility design for conversion a conventional turbine to POGT duty, and system analyses of POGT based units for production of power solely, and combined production of power and yngas/hydrogen for different applications. Retrofit design study was completed for three engines, SGT 800, SGT 400, and SGT 100, and includes: replacing the combustor with the POR, compressor downsizing for about 50% design flow rate, generator replacement with 60 90% ower output increase, and overall unit integration, and extensive testing. POGT performances for four turbines with power output up to 350 MW in POGT mode were calculated. With a POGT as the topping cycle for power generation systems, the power output from the POGT ould be increased up to 90% compared to conventional engine keeping hot section temperatures, pressures, and volumetric flows practically identical. In POGT mode, the turbine specific power (turbine net power per lb mass flow from expander exhaust) is twice the value of the onventional turbine. POGT based IGCC plant conceptual design was developed and major components have been identified. Fuel flexible fluid bed gasifier, and novel POGT unit are the key components of the 100 MW IGCC plant for co producing electricity, hydrogen and/or yngas. Plant performances were calculated for bituminous coal and oxygen blown versions. Various POGT based, natural gas fueled systems for production of electricity only, coproduction of electricity and hydrogen, and co production of electricity and syngas for gas to liquid and hemical processes were developed and evaluated. Performance calculations for several versions of these systems were conducted. 64.6 % LHV efficiency for fuel to electricity in combined cycle was achieved. Such a high efficiency arise from using of syngas from POGT exhaust s a fuel that can provide required temperature level for superheated steam generation in HRSG, as well as combustion air preheating. Studies of POGT materials and combustion instabilities in POR were conducted and results reported. Preliminary market assessment was performed, and recommendations for POGT systems applications in oil industry were defined. POGT technology is ready to proceed to the engineering prototype stage, which is recommended.

01 COAL, LIGNITE, AND PEAT↗

Annular Pressure Buildup Calculation When Annulus Contains Gas

During the execution of technological operations such as multiple pressure relief or foam separation during well injection, a gas column can form at the wellhead in the annular space, leading to annular pressure buildup (APB). Based on the theory of heat transfer, a model was proposed for calculating the wellbore heat transfer during production. Taking into account the expansion and compression of the fluid, changes in the wellhead volume, the thermodynamic characteristics of the liquid, and the equation of state of the gas, APB calculations were performed. Based on these parameters, the influence of the gas column height on APB was evaluated. The results of the studies show that the coefficients of expansion and compressibility in the annulus depend on density, pressure and temperature: the higher the productivity of the gas well, the higher the temperature and pressure in the annulus; the greater the height of the gas column, the lower the pressure at the wellhead. For a well with a productivity of 30· 10{sup 4} m{sup 3}/day and gas column height of 70 m in the annulus, the APB is reduced to atmospheric pressure. Studies of the model for calculating APB of the annular trapped gas provide a theoretical basis for developing optimal technological parameters for the operation of gas wells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Social impacts of earthquakes caused by gas extraction in the Province of Groningen, The Netherlands

Gas extraction from the Groningen gasfield in the northern Netherlands has led to localised earthquakes which are projected to become more severe. The social impacts experienced by local residents include: damage to property; declining house prices; concerns about the chance of dykes breaking; feelings of anxiety and insecurity; health issues; and anger. These social and emotional impacts are exacerbated by the increasing distrust Groningen people have towards the national government and the gas company, NAM, a partnership between Shell and ExxonMobil. The earthquakes have reopened discussions about the distribution of benefits from gas production and the extent to which benefits are retained locally. Mitigation of the impacts is attempted, but the lack of trust decreases the effectiveness of the mitigation measures. The extent of this experience of previously-unforeseen, unanticipated impacts suggests that a new social and environmental impact assessment needs to be undertaken, and a new Social Impact Management Plan (SIMP) and Impacts and Benefits Agreement (IBA) developed, so that the project can regain its legitimacy and social licence to operate. In addition to conventional gas, this paper has wider relevance for unconventional gas developments, for example shale gas extraction by hydraulic fracturing methods (fracking). - Highlights: • Gas production in Groningen has caused over 1000 earthquakes. • The induced seismicity has caused many social impacts. • Impacts include building damage, reduced house prices, fear and health issues. • Mitigation measures attempted to date are inadequate. • Distrust towards the national government and operator hinders mitigation efforts. • Gas production in Groningen has lost its social licence to operate.

54 ENVIRONMENTAL SCIENCES↗

Exploring the benefits of utilizing small modular device for sustainable and flexible shale gas water management

Growing shale gas extraction in recent years has triggered wide discussions on the associated freshwater requirement and wastewater management. Many optimization approaches have been developed for shale gas water management; however, most of the studies assumed permanent utilization of wastewater treatment facilities with fixed capacities. Considering the rapidly declining characteristics of shale gas wastewater production, these treatment facilities could remain largely underutilized after the first few months/years of production, making them less economically attractive. To maximize the capacity utilization of treatment facilities and further improve the economic performance of shale gas development, this study develops a systematic optimization framework, where the capacity strategy of conventional treatment facilities and utilization of the recent concept of modular manufacturing are both considered for flexible shale gas water management. The proposed mixed-integer linear programming (MILP) model simultaneously optimizes the design and planning of integrated shale gas and water supply chain, with a focus on capacity planning for both large-scale conventional treatment facilities and small-scale modular devices. A series of Marcellus-based case studies are performed to illustrate the applicability of the proposed model and provide general insights into the trade-offs between the multiple types of treatment facilities. The optimization results reveal that the combinatorial utilization of conventional facilities and modular devices for wastewater treatment (66% by conventional facilities and 34% by modular devices) brings 9.3% more reused water for other well development and 6.2% savings in water-related costs, compared to flexible management of only conventional facilities. Furthermore, this work suggests that taking modular device as auxiliary equipment for shale gas water management is most beneficial to increase the capacity utilization of treatment facilities and achieve a more economic and sustainable shale gas production system.

04 OIL SHALES AND TAR SANDS↗

Disordering of helium gas bubble superlattices in molybdenum under ion irradiation and thermal annealing

Self-organization of gas bubbles causes the formation of an ordered array of nanoscale gas bubbles (a gas bubble superlattice), a highly efficient mechanism for gas storage under irradiation. Here, the stability of helium (He) gas bubble superlattices in molybdenum (Mo) under krypton (Kr) ion irradiation and thermal annealing has been investigated. The He gas bubble superlattices gradually become disordered under Kr ion irradiation at 300° C, and the order-disorder transformation process completes at 2.5 dpa. Both transmission electron microscopy (TEM) and synchrotron-based small-angle X-ray scattering (SAXS) reveal that the order-disorder transformation of He gas bubble superlattices is associated with a slight increase in the average bubble size. Phase-field modeling indicates that the inhomogeneous growth and coarsening of bubbles/voids cause the disordering of imperfect superlattices under irradiation and implies that highly ordered superlattices could potentially exhibit much stronger resistance to irradiation damage. Under thermal annealing, the He gas bubble superlattices in Mo become unstable and disordered at 1000° C with the bubble size increasing from ~1.1 to ~1.6 nm. The finding in this research provides insights into the disordering mechanisms of defect superlattices as well as guidance for designing stable defect superlattices in harsh environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas-driven short disconnection mitigates thermal runaway in Li-ion batteries under mechanical abuse

Mechanical abuse poses a critical safety risk to Li-ion batteries by inducing internal short circuits that initiate thermal runaway. Remarkably, voltage recovery frequently emerges during thermal runaway initiation, a phenomenon that conventional theories fail to explain. Here, our study develops a new multiphysics mechanism to explain voltage recovery, termed gas-driven short disconnection, whereby internal gas pressure mechanically disengages short-circuit contacts and causes the cell voltage to rebound. This mechanism incorporates gas generation and its structural impact on the short circuit. Real-time optical and thermal imaging and X-ray computed tomography reveal fluid-structure interaction between internal gas flow and adjacent shorting contacts. We establish a mechanistic framework linking gas-driven short disconnection to cell-level voltage and temperature responses, elucidating the extension–truncation pattern of voltage recovery. Furthermore, thermal regime maps show that a voltage recovery duration exceeding 5 s correlates with limited temperature rise below 150 °C, indicating that sustained short-circuit disconnection suppresses Joule heating. Additionally, a dimensionless criterion is deduced from scaling analysis for physical plausibility of gas-driven short disconnection in mechanically abused cells. This finding inspires smart venting control, which regulates gas release to maintain the internal pressure while dissipating gas enthalpy, thereby providing a device-level strategy for thermal runaway mitigation.

Gas-driven short disconnection↗

A pseudo-kinetic model to simulate phase changes in gas hydrate bearing sediments

Herein, modeling of the phase transitions anticipated in gas hydrate bearing sediments (GHBS) is critical for a proper understanding of time-dependent changes in states and volumes (e.g. the production of methane from this type of soils). We propose a new pseudo-kinetic approach to simulate the typical phase changes anticipated in GHBS, using published experimental results involving gas hydrate dissociation that are the basis of a widely used kinetic model. The proposed pseudo-kinetic model is formulated in the pressure-temperature (P-T) plane and assumes a rate of gas hydrate dissociation (or formation) proportional to the distance between the current state and the phase boundary. The model consists of only one parameter and is simple to implement in numerical simulators. A similar concept is used to model ice formation/thawing phenomena, but based on the ice/liquid-water phase boundary. We implemented the pseudo-kinetic model in a fully coupled thermo-hydro-chemo-mechanical (THCM) finite element code and validated it against experimental results performed on the dissociation of synthetic gas hydrate. We also evaluated the pseudo-kinetic model using synthetic cases covering several scenarios associated with gas hydrate formation/dissociation and ice formation/thawing. The model successfully reproduced the gas production test from a natural GHBS core from Korea (scaled gas venting experiment over 14 h), and also the formation of gas hydrate and ice in permafrost in Alaska (over 2 × 10 6 years). -The analyses show the versatility of the proposed pseudo-kinetic approach by applying it to model the different types of phase transitions typically encounter in GHBS. The simple formulation, easy implementation in numerical simulator, and reduced number of parameters (only one per phase change) make this model an attractive option for simulating phase transformations in problems involving GHBS.

58 GEOSCIENCES↗

An in situ imaging investigation of the effect of gas flow rates on directed energy deposition

Gas flow rates in Directed Energy Deposition (DED) Additive Manufacturing (AM) can significantly affect the quality of built parts by altering melt pool geometry. Using a DED process replicator and in situ synchrotron radiography, together with analogous experiments in an industrial DED machine, we investigate the impact of carrier gas and shield gas flow rates on build quality. The results reveal that there is a critical shield gas flow rate above which melt pools are flattened, tracks widen, and thus layer thickness decreases. The reduction in layer thickness is most prominent in conditions with low carrier gas flow rate, as the highly turbulent shield gas flow may divert slow moving powder particles away from the melt pool, decreasing capture efficiency. Very high flow rates increase internal porosity, as fast-moving particles impacting the melt pool surface can entrain chamber gas behind them. High gas flow rates also cool the melt pool, creating shallower melt pools with increased thermal gradients near the solidification front, increasing pore entrapment in the solidified track.

Additive manufacturing↗

On the validity of the dilute gas assumption for gap conductance calculations in nuclear fuel performance codes

Fill gas thermal conductivity’s dependence on pressure is neglected in today’s nuclear fuel performance codes. Current codes assume that gas behaves as a dilute gas, but the pressure effect is more pronounced at temperatures lower than ten times the critical temperature of each pure gas. The validity of this assumption for nuclear fuel performance is examined herein. Theories related to dilute and dense gas properties are presented, along with their validation against literature data at up to 30 MPa for selected inert gases. Underlying assumptions are clearly described for each model, and their possible impacts on gap conductance calculations are discussed. The dilute gas assumption is valid for helium because it behaves as a dilute gas. However, the assumption is not valid in most gap conductance calculations when the gap is mostly occupied with either lower conductivity gaseous fission products or an initial fill gas other than helium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved methodology to assess modification and completion of landfill gas management in the aftercare period

Highlights: Black-Right-Pointing-Pointer Performance-based evaluation of landfill gas control system. Black-Right-Pointing-Pointer Analytical framework to evaluate transition from active to passive gas control. Black-Right-Pointing-Pointer Focus on cover oxidation as an alternative means of passive gas control. Black-Right-Pointing-Pointer Integrates research on long-term landfill behavior with practical guidance. - Abstract: Municipal solid waste landfills represent the dominant option for waste disposal in many parts of the world. While some countries have greatly reduced their reliance on landfills, there remain thousands of landfills that require aftercare. The development of cost-effective strategies for landfill aftercare is in society's interest to protect human health and the environment and to prevent the emergence of landfills with exhausted aftercare funding. The Evaluation of Post-Closure Care (EPCC) methodology is a performance-based approach in which landfill performance is assessed in four modules including leachate, gas, groundwater, and final cover. In the methodology, the objective is to evaluate landfill performance to determine when aftercare monitoring and maintenance can be reduced or possibly eliminated. This study presents an improved gas module for the methodology. While the original version of the module focused narrowly on regulatory requirements for control of methane migration, the improved gas module also considers best available control technology for landfill gas in terms of greenhouse gas emissions, air quality, and emissions of odoriferous compounds. The improved module emphasizes the reduction or elimination of fugitive methane by considering the methane oxidation capacity of the cover system. The module also allows for the installation of biologically active covers or other features designed to enhance methane oxidation. A methane emissions model, CALMIM, was used to assist with an assessment of the methane oxidation capacity of landfill covers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upgraded biogas from municipal solid waste for natural gas substitution and CO{sub 2} reduction – A case study of Austria, Italy, and Spain

Highlights: • Biogas can be upgraded to create biomethane, a substitute to natural gas. • Biogas upgrading was applied to landfills and anaerobic digestors in 3 countries. • Up to 0.6% of a country’s consumption of natural gas could be replaced by biomethane. • Italy could save 46% of the national CO{sub 2} emissions attributed to the waste sector. • Scenarios were created to increase biomethane production. - Abstract: Biogas is rich in methane and can be further purified through biogas upgrading technologies, presenting a viable alternative to natural gas. Landfills and anaerobic digestors treating municipal solid waste are a large source of such biogas. They therefore offer an attractive opportunity to tap into this potential source of natural gas while at the same time minimizing the global warming impact resulting from methane emissions in waste management schemes (WMS) and fossil fuel consumption reduction. This study looks at the current municipal solid waste flows of Spain, Italy, and Austria over one year (2009), in order to determine how much biogas is generated. Then it examines how much natural gas could be substituted by using four different biogas upgrading technologies. Based on current waste generation rates, exploratory but realistic WMS were created for each country in order to maximize biogas production and potential for natural gas substitution. It was found that the potential substitution of natural gas by biogas resulting from the current WMS seems rather insignificant: 0.2% for Austria, 0.6% for Italy and 0.3% for Spain. However, if the WMS is redesigned to maximize biogas production, these figures can increase to 0.7% for Austria, 1% for Italy and 2% for Spain. Furthermore, the potential CO{sub 2} reduction as a consequence of capturing the biogas and replacing fossil fuel can result in up to a 93% reduction of the annual national waste greenhouse gas emissions of Spain and Italy.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the energy performance of a hybrid membrane-solvent process for flue gas carbon dioxide capture

In this study, a particularly energy intensive step in the conventional amine absorption process to remove carbon dioxide is solvent regeneration using a steam stripping column. An attractive alternative to reduce the energy requirement is gas pressurized stripping, in which a high pressure noncondensable gas is used to strip CO 2 off the rich solvent stream. The gas pressurized stripping column product, having CO 2 at high concentration and high partial pressure, can then be regenerated readily using membrane separation. In this study, we performed an energetic analysis in the form of total equivalent work and found that, for capturing CO 2 from flue gas, this hybrid stripping process consumes 49% less energy compared to the base case conventional MEA absorption/steam stripping process. We also found the amount of membrane required in this process is much less than required for direct CO 2 capture from the flue gas: approximately 100-fold less than a previously published two-stage cross-flow scheme, mostly due to the more favorable pressure ratio and CO 2 concentration. There does exist a trade-off between energy consumption and required membrane area that is most strongly affected by the gas pressurized stripper operating pressure. While initial analysis looks promising from both an energy requirement and membrane unit capital cost, the viability of this hybrid process depends on the availability of advanced, next generation gas separation membranes to perform the stripping gas regeneration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An efficient instance segmentation approach for studying fission gas bubbles in irradiated metallic nuclear fuel

Abstract Gaseous fission products from nuclear fission reactions tend to form fission gas bubbles of various shapes and sizes inside nuclear fuel. The behavior of fission gas bubbles dictates nuclear fuel performances, such as fission gas release, grain growth, swelling, and fuel cladding mechanical interaction. Although mechanical understanding of the overall evolution behavior of fission gas bubbles is well known, lacking the quantitative data and high-level correlation between burnup/temperature and microstructure evolution blocks the development of predictive models and reduces the possibility of accelerating the qualification for new fuel forms. Historical characterization of fission gas bubbles in irradiated nuclear fuel relied on a simple threshold method working on low-resolution optical microscopy images. Advanced characterization of fission gas bubbles using scanning electron microscopic images reveals unprecedented details and extensive morphological data, which strains the effectiveness of conventional methods. This paper proposes a hybrid framework, based on digital image processing and deep learning models, to efficiently detect and classify fission gas bubbles from scanning electron microscopic images. The developed bubble annotation tool used a multitask deep learning network that integrates U-Net and ResNet to accomplish instance-level bubble segmentation. With limited annotated data, the model achieves a recall ratio of more than 90%, a leap forward compared to the threshold method. The model has the capability to identify fission gas bubbles with and without lanthanides to better understand the movement of lanthanide fission products and fuel cladding chemical interaction. Lastly, the deep learning model is versatile and applicable to the micro-structure segmentation of similar materials.

36 MATERIALS SCIENCE↗

Investigations of lower hybrid wave-plasma coupling by gas puffing in HT-7

Lower hybrid wave (LHW)-plasma coupling experiments in HT-7 [J. K. Xie and HT-7 Group, Proceedings of the 16th International Conference on Fusion Energy, Montreal, 1996 (IAEA, Trieste, 1997), Vol. 1, p. 685] were carried out by means of puffing gas (CD{sub 4} and D{sub 2}) just around the antenna. Both experiments show that wave-plasma coupling is improved by the gas puffing. The maximum distance between the plasma and the antenna is limited to about 8 cm due to the plasma disruption. The variation in the lined averaged density in the different channels gives a possible evidence of the mechanism of the ionization of neutral gas. The effect of the gas flow rate on the wave-plasma coupling shows that an optimized gas flow rate is necessary for good coupling, being consistent with simulation through Brambilla theory qualitatively. Experiments with puffing D{sub 2} show that the improved coupling results from the global density increase and the local gas puffing. Langmuir probe measurements indicate that the gas puffing effectively increases the density and decreases the temperature in scrape of layer. Studies show that the ionization of the puffed gas is affected by both LHW electric field and plasma temperature. Comparison of D{sub 2} and CD{sub 4} puffing shows that D{sub 2} improves coupling better with less effect on core density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GEOMETRIC OFFSETS ACROSS SPIRAL ARMS IN M51: NATURE OF GAS AND STAR FORMATION TRACERS

We report measurements of geometric offsets between gas spiral arms and associated star-forming regions in the grand-design spiral galaxy M51. These offsets are a suggested measure of the star formation timescale after the compression of gas at spiral arm entry. A surprising discrepancy, by an order of magnitude, has been reported in recent offset measurements in nearby spiral galaxies. Measurements using CO and H{alpha} emission find large and ordered offsets in M51. On the contrary, small or non-ordered offsets have been found using the H I 21 cm and 24 {mu}m emissions, possible evidence against gas flow through spiral arms, and thus against the conventional density-wave theory with a stationary spiral pattern. The goal of this paper is to understand the cause of this discrepancy. We investigate potential causes by repeating those previous measurements using equivalent data, methods, and parameters. We find offsets consistent with the previous measurements and conclude that the difference of gas tracers, i.e., H I versus CO, is the primary cause. The H I emission is contaminated significantly by the gas photodissociated by recently formed stars and does not necessarily trace the compressed gas, the precursor of star formation. The H I gas and star-forming regions coincide spatially and tend to show small offsets. We find mostly positive offsets with substantial scatter between CO and H{alpha}, suggesting that gas flow through spiral arms (i.e., density wave) though the spiral pattern may not necessarily be stationary.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINING THE MILKY WAY'S HOT GAS HALO WITH O VII AND O VIII EMISSION LINES

The Milky Way hosts a hot (≈2 × 10{sup 6} K), diffuse, gaseous halo based on detections of z = 0 O VII and O VIII absorption lines in quasar spectra and emission lines in blank-sky spectra. Here we improve constraints on the structure of the hot gas halo by fitting a radial model to a much larger sample of O VII and O VIII emission line measurements from XMM-Newton/EPIC-MOS spectra compared to previous studies (≈650 sightlines). We assume a modified β-model for the halo density distribution and a constant-density Local Bubble from which we calculate emission to compare with the observations. We find an acceptable fit to the O VIII emission line observations with χ{sub red}{sup 2} (dof) = 1.08 (644) for best-fit parameters of n{sub o}r{sub c}{sup 3β}=1.35±0.24 cm{sup –3} kpc{sup 3β} and β = 0.50 ± 0.03 for the hot gas halo and negligible Local Bubble contribution. The O VII observations yield an unacceptable χ{sub red}{sup 2} (dof) = 4.69 (645) for similar best-fit parameters, which is likely due to temperature or density variations in the Local Bubble. The O VIII fitting results imply hot gas masses of M(<50 kpc) = 3.8{sub −0.3}{sup +0.3}×10{sup 9} M{sub ⊙} and M(<250 kpc) = 4.3{sub −0.8}{sup +0.9}×10{sup 10} M{sub ⊙}, accounting for ≲50% of the Milky Way's missing baryons. We also explore our results in the context of optical depth effects in the halo gas, the halo gas cooling properties, temperature and entropy gradients in the halo gas, and the gas metallicity distribution. The combination of absorption and emission line analyses implies a sub-solar gas metallicity that decreases with radius, but that also must be ≥0.3 Z {sub ☉} to be consistent with the pulsar dispersion measure toward the Large Magellanic Cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

Maximization of ICRF power by SOL density tailoring with local gas injection

We report that experiments have been performed under the coordination of the International Tokamak Physics Activity (ITPA) on several tokamaks, including ASDEX Upgrade (AUG), JET and DIII-D, to characterize the increased Ion cyclotron range of frequency (ICRF) antenna loading achieved by optimizing the position of gas injection relative to the RF antennas. On DIII-D, AUG and JET (with the ITER-Like Wall) a 50% increase in the antenna loading was observed when injecting deuterium in ELMy H-mode plasmas using mid-plane inlets close to the powered antennas instead of divertor injection and, with smaller improvement when using gas inlets located at the top of the machine. The gas injection rate required for such improvements (similar to 0.7 x 10(22) el s(-1) in AUG, similar to 1.0 x 10(22) el s(-1) in JET) is compatible with the use of this technique to optimize ICRF heating during the development of plasma scenarios and no degradation of confinement was observed when using the mid-plane or top inlets compared with divertor valves. An increase in the scrape-off layer (SOL) density was measured when switching gas injection from divertor to outer mid-plane or top. On JET and DIII-D, the measured SOL density increase when using main chamber puffing is consistent with the antenna coupling resistance increase provided that the distance between the measurement lines of sight and the injection location is taken into account. Optimized gas injection was also found to be beneficial for reducing tungsten (W) sputtering at the AUG antenna limiters, and also to reduce slightly the W and nickel (Ni) content in JET plasmas. Modeling the specific effects of divertor/top/mid-plane injection on the outer mid-plane density was carried out using both the EDGE2D-EIRENE and EMC3-EIRENE plasma boundary code packages; simulations indeed indicate that outer mid-plane gas injection maximizes the density in the mid-plane close to the injection point with qualitative agreement with the AUG SOL density measurements for EMC3-EIRENE. Field line tracing for ITER in the 15 MA Q(DT) = 10 reference scenario indicates that the planned gas injection system could be used to tailor the density in front the antennas. Lastly, benchmarking of EMC3-EIRENE against AUG and JET data is planned as a first step towards the ITER SOL modelling required to quantify the effect of gas injection on the SOL density in front of the antennas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its 'dialed in' value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

43 PARTICLE ACCELERATORS↗