Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Active-passive airborne ocean color measurement. I - Instrumentation

The instrumentation used in a multichannel lidar fluorosensor spectrometer functioning concurrently as a passive spectroradiometer for measuring upwelling ocean color radiance is discussed. The instrument calibration techniques are addressed, including the absolute passive calibration technique, the importance of relative channel-to-channel calibration for accurate ocean color measurement, and active mode calibration techniques using passive calibration transfer methods. Ground and flight test results from the dual-mode active-passive ocean color sensor are discussed.

Hoge, F. E.↗

ICIASF '85 - International Congress on Instrumentation in Aerospace Simulation Facilities, 11th, Stanford University, CA, August 26-28, 1985, Record

Developments related to laser Doppler velocimetry are discussed, taking into account a three-component dual beam laser-Doppler-anemometer to be operated in large wind tunnels, a new optical system for three-dimensional laser-Doppler-anemometry using an argon-ion and a dye laser, and a two-component laser Doppler velocimeter by switching fringe orientation. Other topics studied are concerned with facilities, instrumentation, control, hot wire/thin film measurements, optical diagnostic techniques, signal and data processing, facilities and adaptive wall test sections, data acquisition and processing, ballistic instrument systems, dynamic testing and material deformation measurements, optical flow measurements, test techniques, force measurement systems, and holography. Attention is given to nonlinear calibration of integral wind tunnel balances, a microcomputer system for real time digitized image compression, and two phase flow diagnostics in propulsion systems.

Source record↗

Testing Instrument for Flight-Simulator Displays

Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.

Haines, Richard F.↗

Future instrumentation and missions for measurements of tropospheric trace species from space: Workshop recommendations

It was recommended that gas filter correlation radiometry and high-resolution interferometry be exploited and expanded for measurements of the distribution of tropospheric trace gases. Instruments and missions were identified and discussed. Several instrument/measurement/mission feasibility studies were recommended, including: a three-layer measurement of carbon monoxide, using a nadir-viewing gas filter correlation radiometer; a lower or middle tropospheric measurement of methane, using a nadir-viewing gas filter correlation radiometer; and a survey of lower, middle, and upper tropospheric trace gases using a nadir-viewing high-resolution interferometer operating in the thermal emission mode. It was also concluded that lidar systems appear to have the potential of obtaining measurments of tropospheric trace gases and aerosols from space. In addition to the specific instrument/mission recommendations, the panels made several general recommendations that may lead to future spaceborne instruments, techniques, and missions for tropospheric research.

Source record↗

Reduction of ground noise in the transmitter crowbar instrumentation system by the use of baluns and other noise rejection methods

Electrical noise interference in the transmitter crowbar monitoring instrumentation system creates false sensing of crowbar faults during a crowbar firing. One predominant source of noise interference is the conduction of currents in the instrumentation cable shields. Since these circulating ground noise currents produce noise that is similar to the crowbar fault sensing signals, such noise interference reduces the ability to determine true crowbar faults.

Daeges, J.↗

Jet transport flight operations using cockpit display of traffic information during instrument meteorological conditions: Simulation evaluation

A simulation study was undertaken to evaluate flight operations using cockpit display of traffic information (CDTI) in a conventional jet transport aircraft. Eight two-person airline flight crews participated as test subjects flying simulated terminal area approach and departure operations under instrument meteorological conditions (IMC). A fixed-base cockpit simulator configured with a full complement of conventional electromechanical instrumentation to permit full workload operations was utilized. Traffic information was displayed on a color cathode-ray tube (CRT) mounted above the throttle quadrant in the typical weather radar location. A transparent touchpanel overlay was utilized for pilot interface with the display. Air traffic control (ATC) simulation included an experienced controller and full partyline radio environment for evaluation of pilot-controlled self-separation and traffic situation monitoring tasks. Results of the study revealed the CDTI to be well received by the test subjects as a useful system which could be incorporated into an existing jet transport cockpit. Crew coordination and consistent operating procedures were identified as important considerations in operational implementation of traffic displays. Cockpit workload was increased with active CDTI tasks. However, all test subjects rated the increase to be acceptable.

Williams, David H.↗

Shuttle Imaging Radar-B/C instruments

The successfully flown Shuttle Imaging Radar-B (SIR-B) instrument is described, giving details of the hardware, the subsystem functions, and the Shuttle interfaces. The preliminary design of the SIR-C instrument is described, giving an overview of the preliminary hardware design, the subsystem functional design, and the Shuttle interfaces.

Huneycutt, Bryan L.↗

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

Instrument characterization for the detection of long-term changes in stratospheric ozone - An analysis of the SBUV/2 radiometer

The scientific objective of unambiguously detecting subtle global trends in upper stratospheric ozone requires that one maintains a thorough understanding of the satellite-based remote sensors intended for this task. The instrument now in use for long term ozone monitoring is the SBUV/2 being flown on NOAA operational satellites. A critical activity in the data interpretation involves separating small changes in measurement sensitivity from true atmospheric variability. By defining the specific issues that must be addressed and presenting results derived early in the mission of the first SBUV/2 flight model, this work serves as a guide to the instrument investigations that are essential in the attempt to detect long-term changes in the ozone layer.

Frederick, J. E.↗

Three-dimensional trajectory analyses of two drop sizing instruments - PMS OAP and PMS FSSP

Flow-induced distortions of water drop fluxes and speeds as seen by the PMS optical array probe (OAP) and the PMS forward scattering spectrometer probe (FSSP) are estimated via three-dimensional flow and trajectory calculation methods. The sensitivities of the instruments to water drop diameter, angle of attack, and free stream air speed are determined. The instruments are first placed in isolation and then mounted under the wing of a Twin Otter airplane. For the wing-mounted OAP at 4-deg angle of attack, partial flow stagnation under the uptilted wing causes a significant decrease in both the flux and speed for small water drops. For the wing-mounted FSSP, sensitivity is found to both angle of attack and free stream air speed.

Norment, H. G.↗

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

In situ ozone instrumentation for 10-Hz measurements - Development and evaluation

The development of the fast-response ozone detector for the Electra aircraft is described. The selection of a technique to meet the design goal of 10-Hz detection is examined in terms of detection principles, instrument sampling parameters, signal conditioning, and aircraft and sampling environment. An instrument which employs a NO technique for detection of ozone with a reaction chamber volume of 16 cu cm, a pressure of 60 torr, and a sample flow of 1000 standard cu cm/min was developed. Laboratory and flight testings of the detector were conducted in order to evaluate its performance. The data reveal that the fast-response ozone detector is highly reliable with a response of 0.1 sec to 90 percent of reading, has a lower detection limit of 1 ppbv, and an S/N of 20 at 20 ppbv ozone.

Gregory, G. L.↗

Instrumentation utilisation for risk control in safety operations

Ways in which instrumentation is utilized for risk control for inherently safe (no control or guidance) and flight programmed launch vehicles is presented. Instrumentation and how it is utilized in the launching and recovery of balloons and payloads is also presented. Wind sensing, computer systems, tracking, and telemetry are discussed.

Swayer, F. R.↗

Development of a facility using robotics for testing automation of inertial instruments

The Integrated Robotics System Simulation (ROBSIM) was used to evaluate the performance of the PUMA 560 arm as applied to testing of inertial sensors. Results of this effort were used in the design and development of a feasibility test environment using a PUMA 560 arm. The implemented facility demonstrated the ability to perform conventional static inertial instrument tests (rotation and tumble). The facility included an efficient data acquisitions capability along with a precision test servomechanism function resulting in various data presentations which are included in the paper. Analysis of inertial instrument testing accuracy, repeatability and noise characteristics are provided for the PUMA 560 as well as for other possible commercial arm configurations. Another integral aspect of the effort was an in-depth economic analysis and comparison of robot arm testing versus use of contemporary precision test equipment.

Greig, Joy Y.↗

Reactor instrumentation and control design and performance simulation for SP-100

The SP-100 flight system will be launched with all primary and secondary lithium in the solid state. Once in orbit, the reactor will be brought critical and maintained at a low power level while the lithium is thawed out. Once the system is thawed out, the reactor power will be controlled to provide the energy source required by the power conversion system to meet the payload electrical power requirements. The Reactor Instrumentation and Control subsystem which includes the reactor control drives, instrumentation and the digital controller provides for the control of the nuclear subsystem to perform these operating maneuvers as well as providing for automatic shutdown and restart under certain off-normal conditions. The design and performance of this system are described.

Meyer, R. A.↗

Problems and approaches to the calibration of solar EUV instrumentation in space

Accurate measurements of the Sun's extreme ultraviolet (EUV) emission are of major importance in aeronomical studies of the Earth's upper atmosphere and for studies of the Sun's outer atmosphere, where the radiation originates in the tenuous, high-temperature chromosphere and corona. Current levels of calibration accuracy of space instrumentation used to observe this radiation and accuracies desired in the future are discussed. Several suggestions are made for methods that can provide approximate recalibrations of instruments in orbit using the radiation from the Sun itself.

Neupert, Werner M.↗

Two-year moored instrument results along 152 deg E

Results from a 2-year (nominal) deployment of a moored array along 152 deg E from 28 deg N to 41 deg N are presented, with emphasis on similarities and differences between settings (approximately year-to-year). Ten moorings and 38 instruments were involved, from the fall of 1980 to 1982. Current-temperature meters spanned the water column from 500- to 4000-m depths, with occasional instruments in the vicinity of 300 m and near the bottom (about 6000 m). Upper level features located in the center of the array near 35-36 deg N were generally stable relative to the axis of the Kuroshio Extension, varying from deployment to deployment with meanders in this flow regime. Some properties of the abyssal (about 4000 m) currents were comparatively more variable, with these changes not connected to meandering of the Kuroshio Extension in an obvious way. The vertical structure and frequency distributions of eddy kinetic energy were similar in shape and to some extent in amplitude from deployment to deployment, especially relative to meanders of the Kuroshio Extension, but translated in the opposite direction.

Schmitz, William J., Jr.↗

Design techniques for developing a computerized instrumentation test plan

The development of a computerized instrumentation test plan (ITP) for the NASA/Ames Research Center National Full Scale Aerodynamics Complex (NFAC) is discussed. The objective of the ITP program was to aid the instrumentation engineer in documenting the configuration and calibration of data acquisition systems for a given test at any of four low speed wind tunnel facilities (Outdoor Aerodynamic Research Facility, 7 x 10, 40 x 80, and 80 x 120) at the NFAC. It is noted that automation of the ITP has decreased errors, engineering hours, and setup time while adding a higher level of consistency and traceability.

Burnett, S. Kay↗