Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

MCNPX Simulation Study of STRAW Neutron Detectors

A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating (only 1 micron thick) of {sup 10}B as a neutron converter inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2 mils thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90%/10% of Ar/CO{sub 2}). The tubes operate in proportional counter mode and attract mobile charged particles ({alpha}'s) created in the nuclear interaction {sup 10}B(n, {sup 4}He){sup 7}Li. However, a single tube has about 1/7th the sensitivity of a {sup 3}He tube. Modeling is required to determine if enough such tubes could be placed in a neutron detection assembly of the current size to give comparable sensitivity to {sup 3}He. Detectors lined with {sup 10}B lie between {sup 3}He and {sup 10}BF{sub 3} proportional counters and fission chambers in terms of neutron detection efficiency and gamma ray insensitivity. The mean free path of thermal neutrons in {sup 10}B is about 18 {micro}m. It takes about 60 {micro}m of {sup 10}B layer to completely stop thermal neutrons, but the energetic {alpha}-particles generated in the reaction have a range of only 3.3 {micro}m in {sup 10}B environment - hence the thin layer of boron coating on the copper tube. The prototype design is shown in Figure 1. It consists of two panels of three staggered rows of 500-mm-long, 4-mm-diameter straws, with 20 in each row, embedded in 30-mm-thick high density polyethylene (HDPE). The project demonstrates a new application of thin neutron and gamma converter technique (1 micron thin {sup 10}B coated copper tube). It exploits fast timing from multiple straw detectors to count multiplicity of both gamma and neutrons from fissioning materials. The objective is to find a near-term replacement of {sup 3}He gas in neutron detection and measurement (with a very large neutron detection area). All the solid-state detectors developed thus far are small and inefficient. The thin size of the straws provides imaging capability with high enough resolution for radiation emitting sources. The prototype will provide the first aerial neutron detection system with directional sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Delayed Neutrons from Fissionable Samples: Monte Carlo Modelling and Physical Assumptions for a Design of the DET-12 Device

An activation of fissionable materials with neutrons has been considered as a possible neutron diagnostic of D–D and D–T fusion plasma. Fission reaction caused by fusion neutrons leads up to emission of secondary neutrons: prompt and delayed. Physical assumptions have been outlined to design a new device (DET-12) for measurements of delayed neutrons emitted from samples of fissionable materials activated with neutrons at big fusion-plasma devices. The aim is to support a classic neutron activation method used as one of plasma diagnostics at tokamaks or stellarators. An interpretation of the time decay of delayed neutrons enables an assessment of the primary neutron flux which induced fission reaction. Monte Carlo calculations have been carried out in order to elaborate the method considered. Nuclides like: pure {sup 235}U, {sup 238}U and {sup 232}Th, have been selected as possible materials to be irradiated. Physical fundamentals of generation of the delayed neutrons are mentioned and a resulting concept of the DET-12 device, built in the Institute of Nuclear Physics, Poland, is presented. A general size and dimensions of particular constituent material layers, and a number and placement of neutron detectors are optimized by means of Monte Carlo modelling. Recommendations for a technical design of the measuring chamber were formulated. Detection efficiency of DET-12 has been also estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the US-Japan collaborative investigation on hydrogen isotope retention in neutron-irradiated and ion-damaged tungsten

Plasma-facing components (PFCs) will be exposed to 14 MeV neutrons from deuterium-tritium (D-T) fusion reactions, and tungsten, a candidate PFC for the divertor in ITER, is expected to receive a neutron dose of 0.7 displacement per atom (dpa) by the end of operation in ITER. The effect of neutron-irradiation damage has been mainly simulated using high-energy ion bombardment. While this prior database of results is quite valuable for understanding the behavior of hydrogen isotopes in PFCs, it does not encompass the full range of effects that must be considered in a practical fusion environment due to short penetration depth, damage gradient, high damage rate, and high PKA energy spectrum of the ion bombardment. In addition, neutrons change the elemental composition via transmutations, and create a high radiation environment inside PFCs, which influence the behavior of hydrogen isotope in PFCs, suggesting the utilization of fission reactors is necessary for neutron irradiation. Therefore, the effort to correlate among high-energy ions, fission neutrons, and fusion neutrons is crucial for accurately estimating tritium retention under a neutron-irradiation environment. Under the framework of the US-Japan TITAN program, tungsten samples (99.99 at. % purity from A.L.M.T. Co.) were irradiated by neutron in the High Flux Isotope Reactor (HFIR), ORNL, at 50 and 300C to 0.025, 0.3, and 1.2 dpa, and the investigation of deuterium retention in neutron-irradiation was performed in the INL Tritium Plasma Experiment (TPE), the unique high-flux linear plasma facility that can handle tritium, beryllium and activated materials. This paper reports the recent results from the comparison of ion-damaged tungsten via various ion species (2.8 MeV Fe2+, 20 MeV W2+, and 700 keV H-) with that from neutron-irradiated tungsten to identify the similarities and differences among them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced reaction rates in NDP analysis with neutron scattering

Neutron depth profiling (NDP) makes accessible quantitative information on a few isotopic concentration profiles ranging from the surface into the sample a few micrometers. Because the candidate analytes for NDP are few, there is little interference encountered. Furthermore, neutrons have no charge so mixed chemical states in the sample are of no direct concern. There are a few nuclides that exhibit large probabilities for neutron scattering. The effect of neutron scattering on NDP measurements has not previously been evaluated as a basis for either enhancing the reaction rates or as a source of measurement error. Hydrogen is a common element exhibiting large neutron scattering probability found in or around sample volumes being analyzed by NDP. A systematic study was conducted to determine the degree of signal change when neutron scattering occurs during analysis. The relative signal perturbation was evaluated for materials of varied neutron scattering probability, concentration, total mass, and geometry. Signal enhancements up to 50% are observed when the hydrogen density is high and in close proximity to the region of analysis with neutron beams of sub thermal energies. Greater signal enhancements for the same neutron number density are reported for thermal neutron beams. Even adhesive tape used to position the sample produces a measureable signal enhancement. Because of the shallow volume, negligible distortion of the NDP measured profile shape is encountered from neutron scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostic of fusion neutrons on JET tokamak using diamond detector

In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of intensity modulated neutron radiotherapy (IMNRT)

Purpose: Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center/Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. Methods: IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. Results: While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate/five head and neck) agreed to within -0.8 {+-} 1.4% and 5.0 {+-} 6.0% within and outside the target, respectively. Nearly all (22/24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)/prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and/or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. Conclusions: IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

60 APPLIED LIFE SCIENCES↗

Event Centroiding Applied to Energy-Resolved Neutron Imaging at LANSCE

The energy-dependence of the neutron cross section provides vastly different contrast mechanisms than polychromatic neutron radiography if neutron energies can be selected for imaging applications. In recent years, energy-resolved neutron imaging (ERNI) with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as for quantitative density measurements, was pioneered at the Flight Path 5 beam line at LANSCE and continues to be refined. In this work, we present event centroiding, i.e., the determination of the center-of-gravity of a detection event on an imaging detector to allow sub-pixel spatial resolution and apply it to the many frames collected for energy-resolved neutron imaging at a pulsed neutron source. While event centroiding was demonstrated at thermal neutron sources, it has not been applied to energy-resolved neutron imaging, where the energy resolution requires to be preserved, and we present a quantification of the possible resolution as a function of neutron energy. For the 55 μm pixel size of the detector used for this study, we found a resolution improvement from ~80 μm to ~22 μm using pixel centroiding while fully preserving the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chi-Nu measurements of the prompt fission neutron spectrum of {sup 235}U and {sup 239}Pu - 25581

Knowledge of the prompt fission neutron spectrum is crucial for understanding the behavior of energetic nuclear systems. Although this energy spectrum has been measured for the major actinides {sup 235}U and {sup 239}Pu for decades, the majority of the available literature data lack the coverage of both incident and outgoing neutron energies and the precision required to accurately guide evaluations and fission models. The Chi-Nu experiment is designed to measure the prompt fission neutron spectrum for a wide range of incident and outgoing neutron energies with attention to uncertainty estimation and assessment of systematic errors in order to provide reliable guidance for evaluations and models of nuclear fission. Preliminary results of the prompt fission neutron spectrum from the neutron-induced fission of {sup 235}U and {sup 239}Pu are presented here, with a focus on the presence of spectral features near multi-chance fission thresholds, pre-equilibrium neutrons in the deduced spectrum, and also on trends of the mean fission neutron energy as a function of the incident neutron energy. While the mean energies of from ENDF/B-VIII.0 are in good agreement with those reported for {sup 235}U spectra, significant disagreements exist above an incident neutron energy of approximately 13 MeV for {sup 239}Pu. Furthermore, in general, the physics features regarding multi-chance fission and pre-equilibrium neutron emission newly-introduced into ENDF/B-VIII.0 appear provide an improved description of the data as compared to ENDF/B-VII.1. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron production in lunar habitats - Paper 132

Lunar habitats constructed of either local materials or conventional materials used for spacecraft (such as aluminum) will provide protection for astronauts from solar energetic particles (SEP) and galactic cosmic rays (GCR). Although there are essentially no neutrons in the primary GCR and SEP fields, neutrons are produced by interactions of those fields with the lunar surface and with the lunar habitat. In a habitat, the neutrons can be divided into two categories: albedo neutrons moving generally upward through the habitat, and a generally downward flux created by interactions in the habitat walls. These two neutron fields differ in their energy spectrum, and as a result different mitigation strategies may be needed for different areas of the habitat in order to reduce the dose from neutrons. In this work, we calculate the 'upward' and 'downward' neutron fluences, using a variety of shielding materials and thicknesses. We also investigate the effect of other materials inside the habitat on the neutron fluences. The preliminary transport model calculations performed here verify the effectiveness of a hydrogenous shielding wall material, polyethylene, in reducing the neutron dose inside a simple lunar habitat geometry when compared to walls made of lunar regolith and aluminum. Separate transport model calculations were done for the albedo neutron spectrum rising up from the lunar soil and for GCR particles incident upon the habitat shielding. In the case of GCR ions incident on the habitat, shielding wall made of polyethylene reduced the neutron effective dose by a factor of three, compared to the other two shielding materials. (authors)

36 MATERIALS SCIENCE↗

Improvements to neutron detection of Pu in solvent for an aqueous buffer tank, magnox reprocessing plant, Sellafield - 14216

The PP Active Feed Tank (PPAFT) is a buffer tank that is not safe by geometry and which is located between the Medium Active (MA) and Plutonium Purification (PP) cycles of the chemical separation process in the Magnox Reprocessing Plant. The PPAFT receives Pu nitrate in acid which has been conditioned ready for the extraction of Pu with TBP/OK (tri-butyl phosphate in kerosene) solvent in the PP Cycle. The criticality safety case for the PPAFT recognises that during both normal operations and potential maloperations solvent which is dissolved (TBP which is present in solution but can be released upon a change in acidity) and entrained (TBP/OK physically carried over but not in solution) will accumulate in the PPAFT. The only practicable route out for Pu in solvent in the PPAFT is the normal process route out from the base of the PPAFT to the PP cycle through intermediate vacuum lift and feed vessels. However, the dished end base of the PPAFT and the intermediate vacuum lift and feed vessels are of particularly challenging geometry. There are five neutron monitors placed around the PPAFT for the detection of Pu in solvent. The original design intent of the neutron detection system was that any single monitor should be able to reveal an accumulation of Pu in solvent before it would potentially be unsafe if fed downstream. However, over time there have been changes to the fuel feed and chemical process of the plant which have had the potential to affect the performance of the neutron monitoring system. The ability of the neutron monitoring system to function to its original intent was questioned. Work has recently been carried out to investigate the capabilities of the PPAFT neutron monitoring system for current plant conditions and to identify potential improvements while making best use of the existing neutron monitors. It was found that moving a neutron monitor from the side to the top of the PPAFT and adding alarms based on the ratio of signals from multiple neutron detectors would be effective in improving detection of Pu in solvent. This paper describes the challenges involved in detecting thin layers of Pu in solvent using neutron monitors, discusses the improvements made to the PPAFT neutron monitors and details the combination of real plant data and modelling with the shielding code MCBEND used to provide confidence in the enhanced neutron monitoring system. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitive neutron transverse polarization analysis using a 3 He spin filter

Here we report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change ($\ll$10 –3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3 He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a μ -metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δ θ = 1 / ( P n A N ) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization P n and the analyzing power A . With a high-flux neutron beam, 10 –6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

47 OTHER INSTRUMENTATION↗

Physical particularities of nuclear reactors using heavy moderators of neutrons

In nuclear reactors, thermal neutron spectra are formed using moderators with small atomic weights. For fast reactors, inserting such moderators in the core may create problems since they efficiently decelerate the neutrons. In order to form an intermediate neutron spectrum, it is preferable to employ neutron moderators with sufficiently large atomic weights, using {sup 233}U as a fissile nuclide and {sup 232}Th and {sup 231}Pa as fertile ones. The aim of the work is to investigate the properties of heavy neutron moderators and to assess their advantages. The analysis employs the JENDL-4.0 nuclear data library and the SCALE program package for simulating the variation of fuel composition caused by irradiation in the reactor. The following main results are obtained. By using heavy moderators with small neutron moderation steps, one is able to (1) increase the rate of resonance capture, so that the amount of fertile material in the fuel may be reduced while maintaining the breeding factor of the core; (2) use the vacant space for improving the fuel-element properties by adding inert, strong, and thermally conductive materials and by implementing dispersive fuel elements in which the fissile material is self-replenished and neutron multiplication remains stable during the process of fuel burnup; and (3) employ mixtures of different fertile materials with resonance capture cross sections in order to increase the resonance-lattice density and the probability of resonance neutron capture leading to formation of fissile material. The general conclusion is that, by forming an intermediate neutron spectrum with heavy neutron moderators, one can use the fuel more efficiently and improve nuclear safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials. Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., 235 U or 233 U) fraction, such as highly enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the “primary” delayed neutrons (emitted directly by fission fragments) and the “secondary prompt” fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from “primary” delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. Here, we demonstrate two experimental approaches for discriminating between 235 U and 238 U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

07 ISOTOPE AND RADIATION SOURCES↗

New physics at a neutron beam dump

We find a new utility of neutrons, usually treated as an experimental nuisance causing unwanted background, in probing new physics signals. The new physics signals can either be radiated from neutrons (neutron bremsstrahlung) or appear through secondary particles from neutron-on-target interactions, dubbed “neutron beam dump.” As a concrete example, we take the FASER/FASER2 experiment as a “factory” of high-energy neutrons that interact with the iron dump. We find that if new physics particles had the same interaction strength to protons and neutrons, their production rate via neutron-initiated bremsstrahlung would be comparable to that via proton-initiated ones, in terms of the resulting flux and the range of couplings that can be probed. The neutron bremsstrahlung can be used, for instance, to probe dark gauge bosons with nonzero neutron coupling. In particular, we investigate protophobic gauge bosons and find that FASER/FASER2 can probe new parameter space. We also illustrate the possibility of neutron-induced secondary particles by considering axionlike particles with electron couplings. We conclude that the physics potential of FASER/FASER2 in terms of new physics searches can be greatly extended and improved with the inclusion of neutron interactions. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗