Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Radiological Monitoring Results for Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2012-October 31, 2013

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond WRU-I-0160-01, Modification 1 (formerly LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-cost wireless voltage & current grid monitoring

This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

14 SOLAR ENERGY↗

An Intelligent Adaptable Monitoring Package. Final Report

The “Intelligent Adaptable Monitoring Package” project was a four-year effort that demonstrated the feasibility of integrated sensing packages at tidal and wave energy sites. Such integration is generally required by the breadth of sensors required to understand environmental effects at marine energy sites and the operational difficulty of deploying, maintaining, and recovering such sensors. Over the course of the project, the Adaptable Monitoring Package (AMP) was deployed in multiple settings, each corresponding to a project budget period: - Budget Period 1: Demonstration of cabled deployment at Pacific Northwest National Laboratory’s Marine Science Laboratory. The deployment highlighted AMP hardware endurance over a 4-month deployment in a tidally-dominated environment and laid the groundwork for machine learning algorithms to detect and classify targets present in active sonar data. - Budget Period 2: Demonstration of an autonomous deployment at PacWave South off the coast of Newport, Oregon. The deployment highlighted the stability of AMP hardware and software, with the autonomous package collecting data on a duty cycle over a 1.5-month deployment. - Budget Period 3: Demonstration of an autonomous deployment powered by a wave energy converter at the U.S. Navy’s Wave Energy Test Site. The deployment highlighted the potential of wave energy to power ocean observatories and led to the development of machine learning algorithms to detect and classify targets in optical camera data. In aggregate, this project’s greatest success was demonstrating the AMP’s flexibility in a range of deployment scenarios. Each budget period represented a “first of a kind” demonstration of integrated instrumentation – cabled AMP, autonomous AMP, wave-energy powered AMP – and each deployment helped to identify and set goals for the next. Further, despite the exploratory nature of these deployments, each one achieved high system up-time and proved that flexible integration of multiple sensors in a single package represents a viable strategy for marine energy environmental monitoring. The key lessons learned from the project are: - Without continuous power, either from a shore cable or in situ source, many of the benefits of integration are lost (If continuous power is not available, the ability to detect rare events is lost, as is the ability to minimize the risk of behavioral changes through adaptive sensing. However, even on a duty cycle, there is still value in being able to acquire synchronous data from multiple sensors.); and - Observations from a moving platform present substantially greater data processing challenges than those from stationary platforms. Finally, these deployments also demonstrate an important truth: successful integration alone does not guarantee that relevant data are collected. To grow the knowledge base about environmental interactions with marine energy converters, integrated systems, like the AMP, need to include the right sensor mix and connect the data pipelines to effective processing algorithms. These deployments establish a strong foundation for future collaborations with the environmental research community: not only to understand the environmental effects of marine energy, but also to improve our general ability to study life in the sea.

16 TIDAL AND WAVE POWER↗

Smart Composite Pressure Vessels (SCPV) with Integrated Health Monitoring

The U.S. Department of Energy (DOE) is promoting and developing more energy efficient and environmentally friendly technologies that will enable America to use less petroleum. Hydrogen fuel cells – which directly convert the chemical energy in hydrogen to electricity with only water and heat as byproducts – are a very attractive solution that can enable this to happen. To date, DOE's efforts have culminated in commercial demonstration of on-board vehicular hydrogen storage systems that can allow for a driving range of greater than 300 miles. This requires storing 5 Kgs of hydrogen onboard a light vehicle. In order to store this quantity of hydrogen, the hydrogen gas needs to be stored in a composite overwrapped pressure vessel (COPV) at a very high internal pressure. The objective of the program was to demonstrate continuous and predictable health-monitoring of composite pressure vessels. A higher confidence in the operational safety of the vessels will lead to reduced burst factor of safety imposed by regulatory standards and hence will help reduce the structural wall thickness that drives the cost of the vessel. Highly optimized Type III (metal lined) and Type IV (polymer lined) COPVs that are manufactured using filament winding process have been designed and qualified for the above mentioned application. However, the main structural component of the COPVs is carbon fiber and the high cost of carbon fiber composite in a pressure vessel is a primary challenge in reducing the cost of gaseous hydrogen storage. Continuous and remote monitoring of structural health of the COPVs as well as optimization of the strength translation of carbon fibers have the potential to allow for reduced factor of safety, thereby reduced amount of carbon and associated cost of the vessel. In the current program, the project team including Steelhead Composites (SHC), University of Tennessee, Knoxville (UTK), Teijin Carbon America, Oak Ridge National Laboratory (ORNL) and LUNA designed, fabricated, and tested smart composite pressure vessels with integrated sensors. Iterative loops of design and testing using coupons, subscale STEB vessels and full size vessels proved that a new generation of high performance carbon fiber can be used for efficient design of Type 3 vessels for H2 storage. Novel analysis techniques were developed to predict the initiation and propagation of interlaminar damage inside the composite shell due to impact damage, a real threat in practical operation. Such an analysis scheme is typically not used in tank design but is an essential tool for health monitoring of composite vessels. Remote sensing of the key signatures of the tank’s operating parameters such as pressure, acceleration and humidity was demonstrated using a unique device that can wirelessly transmit and stream the data to a remote server. Fiber optic sensors were successfully integrated during fabrication of the tanks. These sensors provide a wealth of information regarding the structural health of the vessel when it is subsequently pressurized or subjected to impact damage. Excellent correlation was demonstrated between the fiber optic sensor and mechanical strain gage data, and between the measurements and analytical predictions.

08 HYDROGEN↗

Adaptable Monitoring Package Development and Deployment: Lessons Learned for Integrated Instrumentation at Marine Energy Sites

Integrated instrumentation packages are an attractive option for environmental and ecological monitoring at marine energy sites, as they can support a range of sensors in a form factor compact enough for the operational constraints posed by energetic waves and currents. Here we present details of the architecture and performance for one such system—the Adaptable Monitoring Package—which supports active acoustic, passive acoustic, and optical sensing to quantify the physical environment and animal presence at marine energy sites. we describe cabled and autonomous deployments and contrast the relatively limited system capabilities in an autonomous operating mode with more expansive capabilities, including real-time data processing, afforded by shore power or in situ power harvesting from waves. Across these deployments, we describe sensor performance, outcomes for biological target classification algorithms using data from multibeam sonars and optical cameras, and the effectiveness of measures to limit biofouling and corrosion. On the basis of these experiences, we discuss the demonstrated requirements for integrated instrumentation, possible operational concepts for monitoring the environmental and ecological effects of marine energy converters using such systems, and the engineering trade-offs inherent in their development. Overall, we find that integrated instrumentation can provide powerful capabilities for observing rare events, managing the volume of data collected, and mitigating potential bias to marine animal behavior. These capabilities may be as relevant to the broader oceanographic community as they are to the emerging marine energy sector.

16 TIDAL AND WAVE POWER↗

Lessons Learned from the Airborne Particulate Monitor ISS Payload

Particulate monitoring on spacecraft has not been undertaken for air quality purposes for the first twenty years of human habitation on the International Space Station (ISS). The Airborne Particulate Monitor (APM) is a reference-quality instrument technology demonstration that characterized the airborne particles in the ISS cabin in real-time. Onboard aerosols have been measured with this higher fidelity instrument, so future miniaturized low-power aerosol instruments can be reliably compared in future ISS experiments. Several issues were encountered during the payload operations that are a result of the unique environment on ISS, which could not have been anticipated or eliminated by ground testing. First, the ISS had very small amounts of particulate matter in the particle measurement size range of the APM, which was unexpected. Second, despite the measured ‘clean’ environment, larger debris such as lint accumulated regularly on the cleanable inlet screen, which required regular inspection and crew time. The third issue is that particle emissions measured on ISS depend only on the activities in the immediate vicinity of the particle instrument and total particle concentrations cannot be generalized for the entire module. Finally, the sampling efficiency of APM on ISS is unknown because aisle-deployed instruments attached to wall panels of ISS are in the boundary layer of the large-scale ventilation flow of the modules. These issues are discussed and potential solutions for future particulate monitors are presented.

aerosol↗

Robust Online Monitoring for Calibration Assessment of Transmitters and Instrumentation

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this article, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation • Virtual sensing • Sensor response-time assessment These algorithms incorporate, at their base, a Gaussian Process-based uncertainty quantification (UQ) method. Various plant models (using kernel regression, GP, or hierarchical models) may be used to predict sensor responses under various plant conditions. These predicted responses can then be applied in fault detection (sensor output and response time) and in computing the correct value (virtual sensing) of a failing physical sensor. The methods being evaluated in this work can compute confidence levels along with the predicted sensor responses, and as a result, may have the potential for compensating for sensor drift in real-time (online recalibration). Evaluation was conducted using data from multiple sources (laboratory flow loops and plant data). Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

fault detection↗

Tracking and Monitoring with Dosimeter-Enabled ARG-US RFID System - 12009

Automated monitoring and tracking of materials with radio frequency identification (RFID) technology can significantly improve both the operating efficiency of radiological facilities and the application of the ALARA (as low as reasonably achievable) principle in them. One such system, called ARG-US, has been developed by Argonne National Laboratory for the U.S. Department of Energy (DOE) Packaging and Certification Program to use in managing sensitive nuclear and radioactive materials. Several ARG-US systems are in various stages of deployment and advanced testing across DOE sites. ARG-US utilizes sensors in the tags to continuously monitor the state of health of the packaging and promptly disseminates alarms to authorized users. In conjunction with global positioning system (GPS) tracking provided by TRANSCOM, the system can also monitor and track packages during transport. A compact dosimeter has been incorporated in the ARG-US tags via an onboard universal asynchronous receiver/transmitter interface. The detector has a wide measurement range for gamma radiation - from 0.1 mSv/h to 8 Sv/h. The detector is able to generate alarms for both high and low radiation and for a high cumulative dose. In a large installation, strategically located dosimeter-enabled tags can yield an accurate, real-time, 2D or 3D dose field map that can be used to enhance facility safety, security, and safeguards. This implementation can also lead to a reduced need for manned surveillance and reduced exposure of personnel to radiation, consistent with the ALARA principle at workplaces. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SOMA: Observability, monitoring, and in situ analytics for exascale applications

With the rise of exascale systems and large, data-centric workflows, the need to observe and analyze high performance computing (HPC) applications during their execution is becoming increasingly important. HPC applications are typically not designed with online monitoring in mind, therefore, the observability challenge lies in being able to access and analyze interesting events with low overhead while seamlessly integrating such capabilities into existing and new applications. We explore how our service-based observation, monitoring, and analytics (SOMA) approach to collecting and aggregating both application-specific diagnostic data and performance data addresses these needs. Furthermore, we present our SOMA framework and demonstrate its viability with LULESH, a hydrodynamics proxy application. Then we focus on Astaroth, a multi-GPU library for stencil computations, highlighting the integration of the TAU and APEX performance tools and SOMA for application and performance data monitoring.

97 MATHEMATICS AND COMPUTING↗

The Kimberlina synthetic multiphysics dataset for CO 2 monitoring investigations

Abstract We present a synthetic multi‐scale, multi‐physics dataset constructed from the Kimberlina 1.2 CO 2 reservoir model based on a potential CO 2 storage site in the Southern San Joaquin Basin of California. Among 300 models, one selected reservoir‐simulation scenario produces hydrologic‐state models at the onset and after 20 years of CO 2 injection. Subsequently, these models were transformed into geophysical properties, including P‐ and S‐wave seismic velocities, saturated density where the saturating fluid can be a combination of brine and supercritical CO 2 , and electrical resistivity using established empirical petrophysical relationships. From these 3D distributions of geophysical properties, we have generated synthetic time‐lapse seismic, gravity and electromagnetic responses with acquisition geometries that mimic realistic monitoring surveys and are achievable in actual field situations. We have also created a series of synthetic well logs of CO 2 saturation, acoustic velocity, density and induction resistivity in the injection well and three monitoring wells. These were constructed by combining the low‐frequency trend of the geophysical models with the high‐frequency variations of actual well logs collected at the potential storage site. In addition, to better calibrate our datasets, measurements of permeability and pore connectivity have been made on cores of Vedder Sandstone, which forms the primary reservoir unit. These measurements provide the range of scales in the otherwise synthetic dataset to be as close to a real‐world situation as possible. This dataset consisting of the reservoir models, geophysical models, simulated time‐lapse geophysical responses and well logs forms a multi‐scale, multi‐physics testbed for designing and testing geophysical CO 2 monitoring systems as well as for imaging and characterization algorithms. The suite of numerical models and data have been made publicly available for downloading on the National Energy Technology Laboratory's (NETL) Energy Data Exchange (EDX) website.

58 GEOSCIENCES↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perioperative Hemodynamic Monitoring of Common Hepatic Artery for Endovascular Embolization of a Pancreaticoduodenal Arcade Aneurysm with Celiac Stenosis

This report describes perioperative hemodynamic monitoring of the common hepatic artery (CHA) during endovascular treatment of a pancreaticoduodenal arcade aneurysm, in a patient with celiac artery stenosis caused by the median arcuate ligament. Pressure monitoring was performed as a safety measure against critical complications such as liver ischemia. As the aneurysm was located in the anterior pancreaticoduodenal artery (APDA) and the posterior pancreaticoduodenal artery (PPDA) was small in caliber, the patient was considered to be at a high risk of liver ischemia. No significant change in pressure was observed in the CHA on balloon occlusion test in the APDA. Immediately after embolization, the PPDA enlarged and the pressure in the CHA was well maintained. Pressure monitoring appears to improve patient safety during endovascular treatment of visceral aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to procedure type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral Methods of Remote-Sensing Monitoring of Radioactive Substances and Toxic Chemicals

The physical principles of passive and active methods of remote-sensing monitoring of radioactive substances and toxic chemicals in accidental emissions (leaks) at nuclear fuel cycle objects are examined. The analytical possibilities of the most sensitive methods of remote-sensing monitoring, which are based on the advances made in UV and microwave range radiometry, laser IR-absorption spectroscopy, laser-induced fluorescence, and laser spark emission spectrometry, are discussed. The prospects for the development of spectral methods of remote-sensing monitoring in different ranges are analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of Insulation Monitoring Devices on the Operation of DC Control Circuits

The insulation level of DC control circuits is an important safety-critical factor and, thus, should be subject to continuous and periodic monitoring. The methods used for monitoring the insulation in live circuits may, however, disturb the reliable operation of control relays. The risks of misoperation and failure to reset of relays posed by the operation of various insulation monitoring and fault location systems are evaluated.

42 ENGINEERING↗

Method for Continuous Monitoring of Electrospray Ion Formation

A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography–selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗