Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

CYANATE ION IN COMPACT AMORPHOUS WATER ICE

The 4.62 {mu}m infrared (2164.5 cm{sup -1}) absorption band, observed in ice mantels toward many young stellar objects, has been mostly attributed to the {nu}{sub 3} (CN stretch) band of OCN{sup -} ions. We present in this work a spectroscopic study of OCN{sup -} ions embedded in compact amorphous ice in a range of concentrations and temperatures relevant to astronomical observations together with quantum mechanical calculations of the {nu}{sub 3} band of OCN{sup -} in various H{sub 2}O environments. The ice samples containing the ions are prepared through hyperquenching of liquid droplets of K{sup +}OCN{sup -} solutions on a substrate at 14 K. The {nu}{sub 3} OCN{sup -} band appears as a broad feature peaking at 4.64 {mu}m with a secondary maximum at 4.54 {mu}m and is much weaker than the corresponding peak in the liquid solution or in the solid salt. A similar weakening is observed for other OCN{sup -} absorption peaks at 7.66 {mu}m (2{nu}{sub 2}) and 8.20 {mu}m ({nu}{sub 1}). The theoretical calculations for the {nu}{sub 3} vibration lead to a range of frequencies spanning the experimentally observed width. This frequency spread could help explain the pronounced drop in the band intensity in the ice. The OCN{sup -} {nu}{sub 3} band in the present compact ices is also broader and much weaker than that reported in the literature for OCN{sup -} ions obtained by variously processing porous ice samples containing suitable neutral precursors. The results of this study indicate that the astronomical detection of OCN{sup -} in ice mantels could be significantly impaired if the ion is embedded in a compact water network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mathematical solutions in internal dose assessment: A comparison of Python-based differential equation solvers in biokinetic modeling

Abstract In biokinetic modeling systems employed for radiation protection, biological retention and excretion have been modeled as a series of discretized compartments representing the organs and tissues of the human body. Fractional retention and excretion in these organ and tissue systems have been mathematically governed by a series of coupled first-order ordinary differential equations (ODEs). The coupled ODE systems comprising the biokinetic models are usually stiff due to the severe difference between rapid and slow transfers between compartments. In this study, the capabilities of solving a complex coupled system of ODEs for biokinetic modeling were evaluated by comparing different Python programming language solvers and solving methods with the motivation of establishing a framework that enables multi-level analysis. The stability of the solvers was analyzed to select the best performers for solving the biokinetic problems. A Python-based linear algebraic method was also explored to examine how the numerical methods deviated from an analytical or semi-analytical method. Results demonstrated that customized implicit methods resulted in an enhanced stable solution for the inhaled 60 Co (Type M) and 131 I (Type F) exposure scenarios for the inhalation pathway of the International Commission on Radiological Protection (ICRP) Publication 130 Human Respiratory Tract Model (HRTM). The customized implementation of the Python-based implicit solvers resulted in approximately consistent solutions with the Python-based matrix exponential method ( expm ). The differences generally observed between the implicit solvers and expm are attributable to numerical precision and the order of numerical approximation of the numerical solvers. This study provides the first analysis of a list of Python ODE solvers and methods by comparing their usage for solving biokinetic models using the ICRP Publication 130 HRTM and provides a framework for the selection of the most appropriate ODE solvers and methods in Python language to implement for modeling the distribution of internal radioactivity.

61 RADIATION PROTECTION AND DOSIMETRY↗

NSTX-U theory, modeling and analysis results

Here, the mission of the low aspect ratio spherical tokamak NSTX-U is to advance the physics basis and technical solutions required for optimizing the configuration of next-step steady-state tokamak fusion devices. NSTX-U will ultimately operate at up to 2 MA of plasma current and 1 T toroidal field on axis for 5 s, and has available up to 15 MW of neutral beam injection power at different tangency radii and 6 MW of high harmonic fast wave heating. With these capabilities NSTX-U will develop the physics understanding and control tools to ramp-up and sustain high performance fully non-inductive plasmas with large bootstrap fraction and enhanced confinement enabled via the low aspect ratio, high beta configuration. With its unique capabilities, NSTX-U research also supports ITER and other critical fusion development needs. Super-Alfvénic ions in beam-heated NSTX-U plasmas access energetic particle (EP) parameter space that is relevant for both α-heated conventional and low aspect ratio burning plasmas. NSTX-U can also generate very large target heat fluxes to test conventional and innovative plasma exhaust and plasma facing component solutions. This paper summarizes recent analysis, theory and modelling progress to advance the tokamak physics basis in the areas of macrostability and 3D fields, EP stability and fast ion transport, thermal transport and pedestal structure, boundary and plasma material interaction, RF heating, scenario optimization and real-time control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HIPED: Machine learning framework for spherical tokamak pedestal prediction and optimization

We introduce a Machine Learning framework, HIPED (HeIght and width Predictor for Edge Dynamics), for predicting and optimizing pedestal and core performance in spherical tokamak plasmas. Trained on pedestal and core datasets from the third MAST-U campaign, HIPED provides accurate estimates of pedestal height and width. The results reveal notable differences compared with conventional aspect-ratio studies; for instance, a simple power-law relation between pedestal width and height has very low accuracy. Instead, additional parameters such as normalized plasma pressure, elongation, and Greenwald fraction significantly improve accuracy. HIPED can also be trained only on `control room parameters' to inform experimentalists of which controllable parameters to adjust for improving core-integrated performance. The framework further includes a multi-objective optimization scheme that helps guide experimental planning and optimization. We find Pareto-optimal discharges with respect to various features, including distance from edge-localized modes and normalized plasma pressure, track their parameter trajectories over time, and identify the control room parameters required for these Pareto-optimal discharges. This provides a framework for systematically optimizing core and edge performance according to different experimental priorities.

Parisi, Jason F. [Princeton Plasma Physics Laborat↗

Observations of compact sources in galaxy clusters using MUSTANG2

Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev–Zel’dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary – largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper, we present 90 GHz compact source measurements from a sample of 30 clusters observed using the MUSTANG2 instrument on the Green Bank Telescope. We present simulations of how a source’s flux density, spectral index, and angular separation from the cluster’s centre affect the measured tSZE in clusters detected by the Atacama Cosmology Telescope (ACT). By comparing the MUSTANG2 measurements with these simulations we calibrate an empirical relationship between 1.4 GHz flux densities from radio surveys and source contamination in ACT tSZE measurements. We find 3 per cent of the ACT clusters have more than a 20 per cent decrease in Compton-y but another 3 per cent have a 10 per cent increase in the Compton-y due to the matched filters used to find clusters. As sources affect the measured tSZE signal and hence the likelihood that a cluster will be detected, testing the level of source contamination in the tSZE signal using a tSZE-selected catalogue is inherently biased. We confirm this by comparing the ACT tSZE catalogue with optically and X-ray-selected cluster catalogues. Furthermore, there is a strong case for a large, high-resolution survey of clusters to better characterize their source population.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Ferroelectricity and superconductivity in strained Eu x Sr 1 – x TiO 3 films

The superconducting transition of SrTiO 3 can be influenced by tuning its ferroelectric transition, but the underlying reasons remain poorly understood. Here, we investigate compressively strained, Sm-doped films of Eu x Sr 1-x TiO 3 that were grown by molecular beam epitaxy to determine the effect of alloying with Eu on both superconductivity and ferroelectricity, both of which are present in strained SrTiO 3 films. Remarkably, superconductivity survives up to x = 0.14. Films at the lowest alloy concentration studied here, x = 0.09, exhibit no suppression of their superconducting transition temperature, but a strong reduction of the upper critical field (H c2 ), compared to non-alloyed, strained SrTiO 3 films. In addition, these films lack the sharp ferroelectric transition that appears in films without Eu in second harmonic generation measurements. Here, we postulate that Eu-alloying causes a crossover from a globally ordered ferroelectric state to one with only short-range polar order. We discuss the connection between the loss of global polar order and the change in the superconducting properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Centrality dependence of Lévy-stable two-pion Bose-Einstein correlations in $\sqrt{𝑠{𝑁⁢𝑁}}$ = 200 GeV Au + Au collisions

The PHENIX experiment measured the centrality dependence of two-pion Bose-Einstein correlation functions in $\sqrt{𝑠{𝑁⁢𝑁}}$ = 200 GeV Au + Au collisions at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. The data are well represented by Lévy-stable source distributions. The extracted source parameters are the correlation-strength parameter 𝜆, the Lévy index of stability 𝛼, and the Lévy-scale parameter 𝑅 as a function of transverse mass 𝑚 𝑇 and centrality. The 𝜆⁡(𝑚 𝑇 ) parameter is constant at larger values of 𝑚 𝑇 , but decreases as 𝑚 𝑇 decreases. The Lévy-scale parameter 𝑅⁡(𝑚 𝑇 ) decreases with 𝑚 𝑇 and exhibits proportionality to the length scale of the nuclear overlap region. The Lévy exponent 𝛼⁡(𝑚 𝑇 ) is independent of 𝑚 𝑇 within uncertainties in each investigated centrality bin, but shows a clear centrality dependence. At all centralities, the Lévy exponent 𝛼 is significantly different from that of Gaussian (𝛼 = 2) or Cauchy (𝛼 = 1) source distributions. Comparisons to the predictions of Monte-Carlo simulations of resonance-decay chains show that, in all but the most peripheral centrality class (50%–60%), the obtained results are inconsistent with the measurements, unless a significant reduction of the in-medium mass of the 𝜂′ meson is included. Finally, in each centrality class, the best value of the in-medium 𝜂′ mass is compared to the mass of the 𝜂 meson, as well as to several theoretical predictions that consider restoration of U 𝐴⁢ (1) symmetry in hot hadronic matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Static and dynamic shear viscosity of a single-layer complex plasma

The static and dynamic (complex) shear viscosity of a single-layer dusty plasma is measured by applying, respectively, a stationary and a periodically modulated shear stress, induced by the light pressure of manipulating laser beams. Under static conditions we observe a decrease of the viscosity with increasing shear rate, the so-called shear-thinning behavior. Under oscillating shear both the magnitude and the ratio of the dissipative and elastic contributions to the complex viscosity show strong frequency dependence, as the system changes from viscous to elastic in nature with increasing excitation frequency. Accompanying molecular dynamics simulations explain and support the experimental observations.

36 MATERIALS SCIENCE↗

Stable Glass Transformation to Supercooled Liquid via Surface-Initiated Growth Front

Highly stable glasses of tris-naphthylbenzene transform into a liquid when annealed above the glass transition temperature T{sub g}. In contrast to the predictions of standard models, the observed transformation is spatially inhomogeneous. Secondary ion mass spectrometry experiments on isotopically labeled multilayer films show that the liquid grows into the stable glass with sharp growth fronts initiated at the free surface and at the interface with the substrate. For the free surface, the growth velocity is constant in time and has the same temperature dependence as self-diffusion in the equilibrium supercooled liquid. These stable glasses are packed so efficiently that surfaces and interfaces are required to initiate the transformation to the liquid even well above T{sub g}.

36 MATERIALS SCIENCE↗

Response of the Lattice across the Filling-Controlled Mott Metal-Insulator Transition of a Rare Earth Titanate

The lattice response of a prototype Mott insulator, SmTiO 3 , to hole doping is investigated with atomic-scale spatial resolution. SmTiO 3 films are doped with Sr on the Sm site with concentrations that span the insulating and metallic sides of the filling-controlled Mott metal-insulator transition (MIT). The GdFeO 3 -type distortions are investigated using an atomic resolution scanning transmission electron microscopy technique that can resolve small lattice distortions with picometer precision. We show that these distortions are gradually and uniformly reduced as the Sr concentration is increased without any phase separation. Significant distortions persist into the metallic state. In conclusion, the results present a new picture of the physics of this prototype filling-controlled MIT, which is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements at forward rapidity of elliptic flow of charged hadrons and open-heavy-flavor muons in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV

Here, we present the first forward-rapidity measurements of elliptic anisotropy of open-heavy-flavor muons at the Relativistic Heavy Ion Collider. The measurements are based on data samples of Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV collected by the PHENIX experiment in 2014 and 2016 with integrated luminosity of 14.5 nb −1 . The measurements are performed in the pseudorapidity range 1.2 < |𝜂| < 2 and cover transverse momenta 1< 𝑝 𝑇 < 4 GeV/𝑐. The elliptic flow of charged hadrons as a function of transverse momentum is also measured in the same kinematic range. We observe significant elliptic flow for both charged hadrons and heavy-flavor muons. The results show clear mass ordering of elliptic flow of light- and heavy-flavor particles. The magnitude of the measured 𝑣 2 is comparable to that in the midrapidity region. This indicates that there is no strong longitudinal dependence in the quark-gluon-plasma evolution between midrapidity and the rapidity range of this measurement at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Transition Models to Design High Performance TESs for the LCLS-II Soft X-Ray Spectrometer

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 μs. In the past, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we observe how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

47 OTHER INSTRUMENTATION↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of carbon in SrTiO{sub 3} grown by hybrid molecular beam epitaxy

Secondary ion mass spectroscopy (SIMS) was used to investigate carbon impurity concentrations in stoichiometric SrTiO{sub 3} films grown by a hybrid molecular beam epitaxy approach that uses an effusion cell to supply strontium, a rf plasma source for oxygen and a metal organic titanium source (titanium tetra isopropoxide). The carbon concentration in the films was measured as a function of growth parameters. At sufficiently high growth temperatures (>800 degree sign C), the films contain a few ppm of carbon. The challenges in accurately quantifying low carbon concentrations are discussed. A carbon-containing contamination layer is detected on the surfaces of SrTiO{sub 3} substrates and air-exposed films by SIMS and in scanning transmission electron microscopy. The contamination layer could be removed by high-temperature predeposition oxygen plasma cleaning.

36 MATERIALS SCIENCE↗