Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Compact AC susceptometer for fast sample characterization down to 0.1 K

We report a new design of an AC magnetic susceptometer compatible with the Physical Properties Measurement System (PPMS) by Quantum Design, as well as with its adiabatic demagnetization refrigerator option. With the elaborate compact design, the susceptometer allows simple and quick sample mounting process. The high performance of the susceptometer down to 0.1 K is demonstrated using several superconducting and magnetic materials. This susceptometer provides a method to quickly investigate qualities of a large number of samples in the wide temperature range between 0.1 and 300 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning magnetoresistance microscopy of atom chips

Surface based geometries of microfabricated wires or patterned magnetic films can be used to magnetically trap and manipulate ultracold neutral atoms or Bose-Einstein condensates. We investigate the magnetic properties of such atom chips using a scanning magnetoresistive (MR) microscope with high spatial resolution and high field sensitivity. By comparing MR scans of a permanent magnetic atom chip to field profiles obtained using ultracold atoms, we show that MR sensors are ideally suited to observe small variations of the magnetic field caused by imperfections in the wires or magnetic materials which ultimately lead to fragmentation of ultracold atom clouds. Measurements are also provided for the magnetic field produced by a thin current-carrying wire with small geometric modulations along the edge. Comparisons of our measurements with a full numeric calculation of the current flow in the wire and the subsequent magnetic field show excellent agreement. Our results highlight the use of scanning MR microscopy as a convenient and powerful technique for precisely characterizing the magnetic fields produced near the surface of atom chips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MULTI-LINE STOKES INVERSION FOR PROMINENCE MAGNETIC-FIELD DIAGNOSTICS

We present test results on the simultaneous inversion of the Stokes profiles of the He I lines at 587.6 nm (D{sub 3}) and 1083.0 nm in prominences (90 deg. scattering). We created data sets of synthetic Stokes profiles for the case of quiescent prominences (B < 200 G), assuming a conservative value of 10{sup -3} of the peak intensity for the polarimetric sensitivity of the simulated observations. In this work, we focus on the error analysis for the inference of the magnetic field vector, under the usual assumption that the prominence can be assimilated to a slab of finite optical thickness with uniform magnetic and thermodynamic properties. We find that the simultaneous inversion of the two lines significantly reduces the errors on the inference of the magnetic field vector, with respect to the case of single-line inversion. These results provide a solid justification for current and future instrumental efforts with multi-line capabilities for the observations of solar prominences and filaments.

79 ASTRONOMY AND ASTROPHYSICS↗

Tangential soft-x ray imaging for three-dimensional structural studies in a reversed field pinch

Tangential soft-x ray (SXR) imaging diagnostic has been developed and three-dimensional (3D) structure of the internal magnetic surface has been deduced by comparing the experimental and calculated two-dimensional SXR images in a reversed field pinch. The SXR imaging system, consisting of a MCP, a fluorescent plate, and an intensified charge coupled device camera, has been installed in REversed field pinch of Low-Aspect-ratio eXperiment (RELAX) machine. Major characteristics of an experimental SXR image could be reproduced by numerical calculations of the image using a single island model, suggesting a helical hot core in RELAX. The SXR imaging system could be useful for 3D structural studies when tangential and vertical simultaneous imaging systems would be installed, with appropriate numerical modeling of 3D structure of the magnetic surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray correlation analysis as a diagnostic tool for the measurement of magnetic turbulence in tokamaks

A diagnostic has been developed for the measurement and characterization of the magnetic turbulence occurring in the core region of a tokamak. A specially shielded detector looking in the tangential direction has been employed to measure the thin target bremsstrahlung from the core plasma. The thick target bremsstrahlung from the limiter is also recorded at the same time. Auto- and cross-correlation analyses have been shown to yield, respectively, the stochasticity of the magnetic fluctuations in the core region and the consequent diffusion coefficient of the nonthermal electrons. The measured stochasticity bears a relationship with the diffusion coefficient. Data obtained from internal magnetic probes corroborate the above trend but the hard x-ray measurement data are shown to be more reliable than those obtained from magnetic probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Ultra-low field NMR for detection and characterization of 235 UF6

We have demonstrated the first ultra-low field (ULF) nuclear magnetic resonance measurements of uranium hexafluoride (UF{sub 6}), both depleted and 70% enriched, which is used in the uranium enrichment process. A sensitive non-invasive detection system would have an important role in non-proliferation surveillance. A two-frequency technique was employed to remove the transients induced by rapidly switching off the 50 mT pre-polarization field. A mean transverse relaxation time T{sub 2} of 24 ms was estimated for the un-enriched UF{sub 6} sample measured at a mean temperature of 80 C. Nuclear magnetic resonance at ULF has several advantages including the ability to measure through metal, such as pipes, and simple magnetic field generation hardware. We present here recent data and discuss the potential for non-proliferation monitoring of enrichment and flow velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact surface decontamination system for surface-sensitive magnetic imaging

A surface decontamination system for application in surface sensitive magnetic imaging tools, such as a spin-polarized scanning electron microscope, is described. Adsorbed contaminant is chemically decomposed with the use of active oxygen in a compact vacuum chamber mounted in a microscope. The present method is especially suitable for fragile magnetic surfaces of complex oxide materials to which the conventional physical etching widely used for magnetic metals could cause serious structural damage. We have succeeded in detecting magnetic signals from a decontaminated oxide surface and visualizing domain images with sufficient magnetic contrast to analyze detailed domain structures.

36 MATERIALS SCIENCE↗

Optimizing a low-energy electron diffraction spin-polarization analyzer for imaging of magnetic surface structures

A newly designed scanning electron microscope with polarization analysis (SEMPA or spin-SEM) for the acquisition of magnetic images is presented. Core component is the spin detector, based on the scattering of low-energy electrons at a W(100) surface in ultrahigh vacuum. The instrument has been optimized with respect to ease of handling and efficiency. The operation and performance of a general low-energy electron diffraction (LEED) detector for SEMPA have been modeled in order to find the optimum operating parameters and to predict the obtainable image asymmetry. Based on the energy dependence of the secondary electron polarization and intensity, the detector output is simulated. For our instrument with optimized performance we demonstrate experimentally 8.6% polarization asymmetry in the domain structure of an iron whisker. This corresponds to 17.2% image contrast, in excellent agreement with the predicted simulated value. A contrast to noise ratio of 27 is achieved at 5 ms acquisition time per pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cosmic Ray Telescope For Educational Purposes

Cosmic ray detectors are widely used, for educational purposes, in order to motivate students to the physics of elementary particles and astrophysics. Using a 'telescope' of scintillation counters, the directional characteristics, diurnal variation, correlation with solar activity, can be determined, and conclusions about the composition, origin and interaction of elementary particles with the magnetic field of earth can be inferred. A telescope was built from two rectangular scintillator panels with dimensions: 91.6x1.9x3.7 cm{sup 3}. The scintillators are placed on top of each other, separated by a fixed distance of 34.6 cm. They are supported by a wooden frame which can be rotated around a horizontal axis. Direction is determined by the coincidence of the signals of the two PMTs. Standard NIM modules are used for readout. This device is to be used in the undergraduate nuclear and particle physics laboratory. The design and construction of the telescope as well as some preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Analysis of Embedded I&C for a Fully Submerged Magnetically Suspended Impeller Pump

Improving nuclear reactor power system designs and fuel-processing technologies for safer and more efficient operation requires the development of new component designs. In particular, many of the advanced reactor designs such as the molten salt reactors and high-temperature gas-cooled reactors have operating environments beyond the capability of most currently available commercial components. To address this gap, new cross-cutting technologies need to be developed that will enable design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operating in these extreme environments. Under this initiative, Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control (I&C) for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump test bed that utilizes submerged magnetic bearings to levitate the shaft. The eventual goal is to apply these techniques to a high-temperature (700°C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper, we will detail the design and analysis of the embedded I&C test bed with submerged magnetic bearings, focusing on the interplay between the different major systems. Then we will analyze the forces on the shaft and their role in the magnetic bearing design. Next, we will develop the radial and thrust bearing geometries needed to meet the operational requirements of the test bed. In conclusion, we will present some initial system identification results to validate the theoretical models of the test bed dynamics.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Broadband Fourier-Transform-Detected EPR at W-Band

This manuscript reports development of wideband Fourier transform (FT) electron paramagnetic resonance (EPR) detection capability at the uniquely high frequency of 94 GHz. Here, this technique is based on the HiPER spectrometer developed at the University of St. Andrews, into which we have integrated an arbitrary waveform generator (AWG) that is used to modulate the output from a solid-state multiplier chain prior to amplification, generating up to 1 kW microwave power with 1 GHz bandwidth. Benchmark experiments are presented for a standard TEMPOL radical, which comprises a 500 MHz broad EPR spectrum at 94 GHz. Using a single frequency-swept microwave pulse, efficient inversion of this spectrum is demonstrated, enabling frequency-dependent studies of the magnetization relaxation in the time-domain, again via broadband echo detection. From these measurements, an anisotropy in the spin–lattice relaxation time, T 1 , can be determined with ease for TEMPOL. In addition, we implement the FT detection scheme for multi-dimensional (electron–electron double resonance, or ELDOR) experiments, demonstrating the full capabilities of the HiPER spectrometer. As an example, we present FT-detected version of the ELDOR-detected nuclear magnetic resonance technique for the TEMPOL radical. We also describe potential applications of the new instrumentation for studies of gadolinium qubits.

36 MATERIALS SCIENCE↗

Neutron spin echo spectroscopy

Neutron spin echo (NSE) spectroscopy is a powerful technique used to probe the internal dynamics and diffusion processes within matter, allowing researchers to quantify how materials respond to changes in external conditions. To fully understand the bulk properties of a material, it is often crucial to investigate dynamic processes occurring on nanometre length scales and nanosecond timescales. NSE spectroscopy provides an exceptional capability to measure such dynamics across a broad spectrum of condensed matter systems, ranging from proteins and quantum magnets to catalysts. In this Primer, we present an overview of NSE spectroscopy, highlighting the instruments used, methods of data collection and representative applications in both soft-matter and hard-matter sciences.

Czakkel, Orsolya [Institut Max von Laue-Paul Lange↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. Lastly, this method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting focusing lenses for the SSR-1 cryomodule of PXIE test stand at Fermilab

Five solenoid-based focusing lenses designed for use inside the SSR1 cryomodule of the PXIE test stand at Fermilab have been fabricated and tested. In addition to a focusing solenoid, each lens is equipped with a set of windings that generate magnetic field in the transverse plane and can be used in the steering dipole mode or as a skew quadrupole corrector. The lenses will be installed between superconducting cavities in the cryomodule, so getting sufficiently low fringe magnetic field was one of the main design requirements. Beam dynamics simulations indicated a need for high accuracy positioning of the lenses in the cryomodule, which triggered a study towards understanding uncertainties of the magnetic axis position relative to the geometric features of the lens. Furthermore, this report summarizes the efforts towards certification of the lenses, including results of performance tests, fringe field data, and uncertainty of the magnetic axis position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Participant Support for Speakers and Early-Career Scientists at the 2012 American Conference on Neutron Scattering (ACNS)

The ACNS provides a focal point for the North American neutron user community, strengthening ties within this diverse group, and promoting neutron research in related disciplines. The conference thus serves a dual role as both a national user meeting and a scientific meeting. As a venue for scientific exchange, the ACNS showcases recent results and provides a forum for scientific discussion of neutron-enabled research in fields as diverse as hard and soft condensed matter, liquids, biology, magnetism, engineering materials, chemical spectroscopy, crystal structure, elementary excitations, fundamental physics, and development of neutron instrumentation. This is achieved through a combination of invited oral presentations, contributed oral presentations, and poster sessions. Adequate opportunity for spontaneous discussion and collaboration is also built into the ACNS program in order to foster free exchange of new scientific ideas and the potential for use of powerful neutron scattering methods beyond the current realms of application. The sixth American Conference on Neutron Scattering (ACNS 2012) provided essential information on the breadth and depth of current neutron-related research worldwide. A strong program of plenary, invited and contributed talks showcased recent scientific results in neutron science in a wide range of fields, including soft and hard condensed matter, biology, chemistry, energy and engineering applications, and neutron physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗