Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Hybrid RICH detector

A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3~GeV/c to 8~GeV/c for the CLAS12 experiments at the upgraded 12~GeV Continuous Electron Beam Accelerator Facility (CEBAF) of Jefferson Lab. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors, and a densely packed and highly segmented photon detector (multi-anode photomultiplier tubes). Depending on the incident particle track angle, Cherenkov light will either be imaged directly (forward tracks) or after two reflections and passes through the aerogel (large angle tracks). The installation of the RICH detector in CLAS12 is scheduled for the fall 2017. In this presentation the detector design will be described, along with the results on individual detector components tests and from testbeam and cosmic ray studies.

Rossi, Patrizia↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2022 Report

In the first two quarters of FY22, data acquisition continued at ORNL and LLNL using uranium sources of known enrichments. This was an FY21 task which could not be completed in FY21 because of problems encountered with the ORNL M400 CZT in Q4 of FY21, and the subsequent repairs. The detector was received back from H3D in the first of September 2021 , and the measurements resumed . Measurements using the repaired detector were completed in Q1 of FY22. The spectra were distributed by ORNL to the analyzing labs. Analysis results were received in Q2 of FY2022. The results from the various codes were intercompared and an ANOVA analysis was performed. Random and systematic uncertainties were established for each code. The ANOVA results and discussions were included in a revised version of FY21Annual Report issued in March 2022. A paper was presented at the INMM 2022Annual Conference, with the analysis results from the various isotopic codes, and the ANOVA table with random and systematic uncertainties. The Project Work Plan (PWP) for FY22 included a task to perform field testing of the M400 CZT and the analysis codes using UF 6 cylinder measurements at the Framatome Fuel Fabrication Facility in Richland, WA. PNNL was the lead for the field testing task. PNNL drafted a Field Test Plan, and refined it based on comments received from the team. PNNL coordinated with Framatome facility, the logistics of carrying out the field testing . A collimator and shield made out of TFlex (tungsten impregnated polymer) was designed and professionally manufactured. The collimators were used in the field test measurements. The measurements at Framatome were completed on April 21, 2022. A total of 34 Type 30B cylinders were measured using three M400 detectors (PNNL, LLNL, and ORNL detectors). Measurements using M400 were taken at two locations on the side of each cylinder and from the end-on bottom location. Additionally, HPGe measurements were taken at the end-on location to establish ground truth. Cylinder wall thickness measurements were also made at all three locations. To gain a better understanding of the effect of background from surrounding cylinders, the same five cylinders measured individually in low background locations were measured again in the cylinder storage yards. Due to inclement weather, manufacturer delays, shipping delays, and equipment failure, the measurement campaign spanned twice as long compared to the original timeline. Gamma-ray spectra from M400 and HPGe detectors, along with the cylinder data and photographs were organized and shared with the collaborators for further analysis. Spectra were analyzed by the participating laboratories. FY22 PWP also consists of tasks related to plutonium source measurements, adapting the codes to analyze plutonium spectra, and inter-comparison of the results from various codes. Plutonium spectra are being acquired at LANL, ORNL, and LLNL. LANL, SNL and LLNL are in the process of modifying FRAM, GADRAS, and CZTU, respectively. The plutonium related tasks will be completed in Q2 of FY23.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CRADA Final Report: CRADA Number NFE-24-10036 with ThermaMatrix, Inc.

ThermaMatrix, Inc provides novel vision inspection solutions for a wide range of manufacturers and industries, providing and implementing the leading technologies for nondestructive inspection (NDI) and material characterization. Many other inspection solutions are either not adequate or are not approachable due to implementation barriers needing expert level operators, excessive inspection time, and high cost. ThermaMatrix’s advanced vision inspection technology addresses all of these limitations. The Lab Embedded Entrepreneurial Program (LEEP) opportunity by the Department of Energy (DOE) allows small-business start-ups to leverage national laboratory capabilities and skilled scientists to rapidly develop their technology that aligns with DOE goals. ThermaMatrix, Inc. was positioned in the Innovation Crossroads program at Oak Ridge National Laboratory to further develop the novel Watson Vision Inspection System to support manufacturing quality control efforts. The research goals were (1) explore fundamental parameters that would improve preexisting capabilities, (2) full-scale industrial setup for demonstration, and (3) capability testing and verification. Manufacturing is demanding more NDI implementation to support their quality control needs, which this technology development would support.

36 MATERIALS SCIENCE↗

Practical Approach To Building A Mid-Wave Remote Sensing System

The purpose of this project, Laser Active Transmitter & Receiver (LATR), was to build a mobile ground based remote sensing system that can detect, identify and quantify a specific gaseous species using Differential Absorption LIDAR (DIAL). This thesis project is concerned with the development and field testing of a mid-wave infrared active remote sensing system, capable of identifying and quantifying emissions in the 3.2 – 3.5 micron range. The goal is to give a brief description of what remote sensing is about and the specific technique used to analyze the collected data. The thesis will discuss the transmitter and the associated subsystems used to create the required wavelength, and the receiver used to collect the returns. And finally, the thesis will discuss the process of collecting the data and some of the results from field and lab collections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Single-Cell Cavities Made of Forged Ingot Niobium at Jefferson Lab

Currently, fine grain niobium (Nb) (grain size ~ 50 um) and large grain Nb (grain size of a few cm) are being used for the fabrication of superconducting radio frequency (SRF) cavities. Medium grain forged ingot with grain size of a few hundred um may be beneficial for cost-effectiveness as well as providing better performance for future SRF-based accelerators. Forged ingot Nb with medium grain size is a novel production method to obtain Nb discs used for the fabrication of superconducting radio frequency cavities. We have fabricated two 1.5 GHz single cell cavities made from forged Nb ingot with a residual resistivity ratio of ~100. The cavities were chemically and mechanically polished and heat-treated in the temperature range of 650-1000 C before the rf test. One of the cavities reached an accelerating gradient of 34 MV/m with a quality factor Q > 1e10, while the second cavity was limited at 14 MV/m, likely due to a weld defect at the equator.

Dhakal, P.↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

Bench Scale Thin Film Composite Hollow Fiber Membranes for Post-Combustion Carbon Dioxide Capture

GE Global Research, Idaho National Laboratory (INL), Georgia Institute of Technology (Georgia Tech), and Western Research Institute (WRI) proposed to develop high performance thin film polymer composite hollow fiber membranes and advanced processes for economical post-combustion carbon dioxide (CO 2 ) capture from pulverized coal flue gas at temperatures typical of existing flue gas cleanup processes. The project sought to develop and then optimize new gas separations membrane systems at the bench scale, including tuning the properties of a novel polyphosphazene polymer in a coating solution and fabricating highly engineered porous hollow fiber supports. The project also sought to define the processes needed to coat the fiber support to manufacture composite hollow fiber membranes with high performance, ultra-thin separation layers. Physical, chemical, and mechanical stability of the materials (individual and composite) towards coal flue gas components was considered via exposure and performance tests. Preliminary design, technoeconomic, and economic feasibility analyses were conducted to evaluate the overall performance and impact of the process on the cost of electricity (COE) for a coal-fired plant including capture technologies. At the onset of the project, Membranes based on coupling a novel selective material polyphosphazene with an engineered hollow fiber support was found to have the potential to capture greater than 90% of the CO 2 in flue gas with less than 35% increase in COE, which would achieve the DOE-targeted performance criteria. While lab-scale results for the polyphosphazene materials were very promising, and the material was incorporated into hollow-fiber modules, difficulties were encountered relating to the performance of these membrane systems over time. Performance, as measured by both flux of and selectivity for CO 2 over other flue gas constituents was found to deteriorate over time, suggesting a system that was more dynamic than initially hypothesized. These phenomena are believed to be associated with the physical and mechanical properties of the separation material, rather than chemical degradation by flue gas or one of its constituents. Strategies to improve the composite systems via alternate chemistries and processing techniques were only partially successful in creating a more robust system, but the research provided critical insight into the barriers to engineering sophisticated composite systems for gas separation. Promising concepts, including a re-engineering of the separation material with interpenetrating polymer networks were identified which may prove useful to future efforts in this field.

36 MATERIALS SCIENCE↗

Developing quantitative capabilities for a scanning microwave impedance microscope

Currently no instrument exists to quantitatively measure electrical properties (dielectric constant and conductivity) on sub-micron regions, a capability of extreme importance to measure the functioning of sub-micron structures and devices. In particular, such electrical measurements could support the development and manufacture of advanced energy related materials used in technologies such as photovoltaic cells, fuel cells and advanced batteries, thereby increasing performance and/or lowering production costs. The goal of this project is to develop microwave imaging add-on modules and probes capable of quantitatively measuring the electrical properties of small regions of a material using microwaves. These modules for scanning probe microscopes, such as atomic force microscopes, make use of the near-field interaction between the exciting microwaves and a material and can resolve regions 10 nanometers in size (less than a million atoms) with little perturbation of the material. In Phase 1 commercial probes and modified hardware were used to establish the feasibility of using microwave imaging systems to quantify local permittivity and conductivity. Repeatable measurements that vary in a systematic way with electrical parameters were obtained from a variety of samples. In Phase 2 research prototypes of the needed hardware and probes were developed and their performance against test structures and real-world samples was demonstrated. Result of this research project include demonstration of quantification of both permittivity and doping level at precisions up to 10% using multiple technical approaches. The level of performance and ease of use meets market expectations and the technology and protocols researched under this grant are currently being commercialized. Quantitative capabilities of this sort will provide a key capability to energy related technologies, and to a wide variety of semiconductor, biological, and materials science applications. Applications include both materials research in academic and industrial labs, as well as manufacturing applications. In a manufacturing environment the quantitative measurement and imaging capabilities could be used both as metrology for process control and as a tool for failure analysis and yield improvement.

36 MATERIALS SCIENCE↗

January 2022 Operational Highlights

The Indexing Lab is now complete and includes classified and unclassified computers, safes and work stations. Staff capture metadata and catalog materials, including classified reports, directors’ correspondence and Rocky Flats materials to ensure the holdings are discoverable and retrievable. Access protocols were updated for products related to the LANL Annual Assessment in the Online Vault (OLV) classified repository. The Annual Assessment is a yearly analysis of the weapons systems in the nation’s nuclear stockpile. The Standardization Quality Assessment (SQA) for the Online Vault (OLV) classified repository was completed and contained no findings. Beta testing, or customer validation, began for the metrics database that generates metrics reports and visualizations from NSRC customer projects.

97 MATHEMATICS AND COMPUTING↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

Thermal energy storage in concrete utilizing a thermosiphon heat exchanger

The performance of a lab-scale concrete thermal energy storage (TES) module with a 2-kWh thermal capacity is evaluated at temperatures up to 400 °C. The TES module uses conventional normal weight concrete with thermal and mechanical properties that are tailored for use as a solid thermal energy storage media. A thermosiphon heat exchanger is used to provide rapid heat transfer into the concrete module, which is reinforced with a steel pipe outer shell. The charging and discharging cycles are examined to assess the thermal performance of the concrete and thermosiphon. Based on the results of testing, the thermosiphon is able to repeatably charge the concrete module from 300 to 400 °C over a 4-h period. After 2250 total hours of charge and discharge cycles, there was no observed delamination between the concrete and the thermosiphon or the steel jacket reinforcement. Non-destructive measurements of the concrete indicated no significant degradation of the solid storage media. The experimental results are then used to validate a numerical model of the concrete TES module for parametric study. Finally, varying insulation conditions were analyzed using this model to determine practical configurations for regular operation of the proposed concrete TES module.

25 ENERGY STORAGE↗

Dispersion Validation for Flow Involving a Large Structure

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) is a relatively new technique that leverages diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. The comparison exercise shows good comparison between model and experimental results, with the wake region downstream of the tall building presenting the most significant challenge to the quantitative accuracy of the model. Model uncertainties are assessed through parametric variations. Some observations are made in relation to the future utility of MDV and CFD, and some productive follow-on activities are suggested that can help mature the science of flow modeling and experimental testing.

54 ENVIRONMENTAL SCIENCES↗

Development of eXternal Nuclear Reaction Analysis (XNRA) Detection Technique for Quantifying Light Isotope Concentrations

The National Nuclear Security Administration’s Tritium Sustainment Program is responsible for the design, development, demonstration, testing, analysis, and characterization of tritium-producing burnable absorber rods (TPBARs) and their components used to produce tritium for the nation’s strategic stockpile. The FY19 call for proposals included the specific basic science research topic, “Demonstration and evaluation of advanced characterization methods, particularly for quantifying the concentration of light isotopes ( 1 H, 3 H, 3 He, and 4 He, 6 Li and 7 Li) in metal or ceramic matrices”. Last year the same language appeared in the call for proposals, and a project IWO-389859 was awarded to the Ion Beam Lab (IBL) at Sandia-NM which was successful using Elastic Recoil Detection, but in the future could have resulted in tritium contamination that jeopardized other equally important NNSA projects. An alternative approach using deuterium nuclear reaction analysis was proposed and funded in FY2019 which was also successful and eliminated any possibility of contaminating the Ion Beam Laboratory with tritium, and will be described in this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Demonstration of Alkalinity Concentration Swing for Direct Air Capture of CO 2

This work constitutes the first lab-scale experimental demonstration of the alkalinity concentration swing (ACS) for direct air capture (DAC) of CO 2 . ACS can be implemented by taking a dilute alkaline solution that has contacted ambient air, and then concentrating it using commercially available desalination technologies. The more concentrated solution has a higher partial pressure of CO 2 relative to the initial solution, allowing the CO 2 to be separated and stored. The ACS approach is based on simple thermodynamics but had never been verified experimentally in terms of extracting CO 2 from air until now. We tested two distinct methods for concentrating the alkaline liquid: reverse osmosis (RO) and capacitive deionization (CDI). We found that to complete the DAC cycle in feasible operating conditions, a bicarbonate-enrichment step needed to be introduced, which selects on bicarbonate ions over carbonate ions. Two approaches for CO 2 extraction to measure the CO 2 yield per amount of water processed by the ACS method were tested. The energy required per amount of CO 2 captured was quantified. We further applied an energy model to study how operating the ACS cycle under different conditions would affect energy requirements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quench Studies of Six High Temperature Nitrogen Doped 9 Cell Cavities for Use in the LCLS-II Baseline Prototype Cryomodule at Jefferson Laboratory

Jefferson Lab (JLab) processed six nine-cell cavities as part of a small-scale production for LCLS-II cavity processing development utilizing the promising nitrogen-doping process. Various nitrogen-doping recipes have been scrutinized to optimize process parameters with the aim to guarantee an unloaded quality factor (Q_0) of 2.7∙10 10 at an accelerating field (Eacc) of 16 MV/m at 2.0 K in the cryomodule. During the R&D phase the characteristic Q0 vs. Eacc performance curve of the cavities has been measured in JLab’s vertical test area at 2 K. The findings showed the characteristic rise of the Q0 with Eacc as expected from nitrogen-doping. Initially, five cavities achieved an average Q0 of 3.3·10 10 at the limiting Eacc averaging to 16.8 MV/m, while one cavity experienced an early quench accompanied by an unusual Q_0 vs. Eacc curve. The project accounts for a cavity performance loss from the vertical dewar test (with or without the helium vessel) to the horizontal performance in a cryomodule, such that these results leave no save margin to the cryomodule specification. Consequently, a refinement of the nitrogen-doping has been initiated to guarantee an average quench field above 20 MV/m without impeding the Q_0. This paper covers the refinement work performed for each cavity, which depends on the initial results, as well as a quench analysis carried out before and after the rework during the vertical RF tests as far as applicable.

43 PARTICLE ACCELERATORS↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗

ABF Industry Engagement Lab Call with Danimer Scientific

This Agile BioFoundry Directed Funding Opportunity project with Danimer Scientific focuses on the development of a strain and a corresponding bioprocess to convert bio-based feedstocks to mixed composition polyhydroxyalkanoates (PHAs). Danimer Scientific produces PHAs today at industrial scale in proprietary strains and for many applications where bio-based, biodegradable materials are advantaged. The project team consists of NREL to lead the strain engineering efforts, PNNL to conduct systems biology experiments that will inform further strain engineering, and Danimer to conduct bioprocess development and materials development. To date, we have on-boarded Danimer strains and demonstrated successful engineering thereof. We anticipate conducting systems biology studies in Spring 2023. Overall, the impact of this DFO project could be improved material properties accessed through the Design-Build-Test-Learn cycle for designer PHA production.

bio-based feedstocks↗