Plug Load Management Through Occupant Engagement at Washington State University

To decrease costs and improve building occupant safety, Washington State University (WSU) began planning a plug load management campaign in 2020, with implementation beginning in 2021. This case study describes the campaign's goals, approach, and results over the past 5 years, ultimately showing that occupant- and behavior-focused strategies can meaningfully reduce plug load energy use while improving health and safety.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Annual Change Report 2008-2009

In meeting the requirement, the DOE provides an annual report each November of all applicable changes under the above requirement. This annual report informs the EPA of changes to information in the most recent compliance application (the 2004 Compliance Recertification Application (CRA)). Significant planned changes must be reported to the EPA prior to implementation by the DOE. In addition, Title 40 CFR, Section 194.4(b)(3) requires that significant unplanned changes be reported to the EPA within 24 hours or ten days, depending on the severity of the activity or condition. Planned changes are submitted on an individual basis. All other changes are reported annually.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress and Future Plans for Mercury Remediation at the Y-12 National Security Complex, Oak Ridge, Tennessee - 13059

The U.S. Department of Energy (DOE), along with the Tennessee Department of Environment and Conservation (TDEC) and the U.S. Environmental Protection Agency (EPA), has identified mercury contamination at the Y-12 National Security Complex (Y-12) as the highest priority cleanup risk on the Oak Ridge Reservation (ORR). The historic loss of mercury to the environment dwarfs any other contaminant release on the ORR. Efforts over the last 20 years to reduce mercury levels leaving the site in the surface waters of Upper East Fork Poplar Creek (UEFPC) have not resulted in a corresponding decrease in mercury concentrations in fish. Further reductions in mercury surface water concentrations are needed. Recent stimulus funding through the American Recovery and Reinvestment Act of 2009 (ARRA) has supported several major efforts involving mercury cleanup at Y-12. Near-term implementation activities are being pursued with remaining funds and include design of a centrally located mercury treatment facility for waterborne mercury, treatability studies on mercury-contaminated soils, and free mercury removal from storm drains. Out-year source removal will entail demolition/disposal of several massive uranium processing facilities along with removal and disposal of underlying contaminated soil. As a National Priorities List (NPL) site, cleanup is implemented under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and directed by the Federal Facility Agreement (FFA) between DOE, EPA, and TDEC. The CERCLA process is followed to plan, reach approval, implement, and monitor the cleanup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Change Report 2006/2007

As part of continuing compliance, the U.S. Environmental Protection Agency (EPA) requires the U.S. Department of Energy (DOE) to provide information on any change in conditions or activities pertaining to the disposal system since the most recent compliance application. This requirement is identified in Title 40 Code of Federal Regulations (CFR), Section 194.4(b)(4), which states: "No later than six months after the administrator issues a certification, and at least annually thereafter, the Department shall report to the Administrator, in writing, any changes in conditions or activities pertaining to the disposal system that were not required to be reported by paragraph (b)(3) of this section and that differ from information contained in the most recent compliance application." In meeting the requirement, the DOE provides an annual report each November of all applicable changes under the above requirement. This annual report informs the EPA of changes to information in the most recent compliance recertification (the 2004 Compliance Recertification). Significant planned changes must be reported to the EPA prior to implementation by the DOE. In addition, Title 40 CFR, Section 194.4(b)(3) requires that significant unplanned changes be reported to the EPA within 24 hours or ten days, depending on the severity of the activity or condition. To date, there have been no significant unplanned changes to the certification basis. Planned changes have been submitted on an individual basis. All other changes are reported annually. Changes in activities or conditions are reviewed to determine if 40 CFR Section 194.4(b)(3) reporting is necessary. As indicated above, no significant unplanned changes were identified for the time period covered by this report. The enclosed tables list those items identified for reporting under 40 CFR Section 194.4(b)(4). The majority of the items described in this report are inspections, reports, and modifications to written plans and procedures for WIPP operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Implementation of an International Training Program on Repository Development and Management

Korea Hydro and Nuclear Power Co., Ltd. (KHNP) is an electric company in the Republic of Korea with twenty operational nuclear power plants and eight additional units that are either planned or currently under construction. Regulations require that KHNP manage the radioactive waste generated by their nuclear power plants. In the course of planning low, intermediate, and high level waste storage facilities, KHNP sought interaction with an acknowledged expert in the field of radioactive waste management and, consequently, contacted Sandia National Laboratories (SNL). KHNP has contracted with SNL to provide a year long training program on repository science. This paper discusses the design of the curriculum, specific plans for execution of the training program, and recommendations for smooth implementation of international training programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at risk, whereas for IMRT it is compromised target coverage. These findings suggest clinical situations where each technique may be most useful if DS constraints are to be employed.

61 RADIATION PROTECTION AND DOSIMETRY↗

APOLLO: a facility-scale differentiable virtual accelerator at Fermilab FAST/IOTA

As the design complexity of modern accelerators grows, there is more interest in using advanced simulations that have fast execution time or yield additional insights like gradients. The FAST/IOTA facility has been working on implementing and experimentally validating an end-to-end digital twin that is both fast and gradient-aware, allowing for rapid prototyping of new software and experiments with minimal beam time costs. Our framework integrates physics and ML codes for linac and ring simulation through a set of generic interfaces between surrogate and physics-based sections. To reproduce device inputs and outputs, system state is exposed as a deterministic event loop in a specialized discrete event simulator architecture. Because Fermilab is undergoing control system transition, several APIs were implemented as final user interfaces - a fully asynchronous EPICS soft IOC, a gRPC-based Data Pool Manager (DPM), and legacy ACNET protocols. We discuss implementation details as well as challenges handling live data assimilation and future plans to extend modelling to main complex proton accelerators like PIPII and Booster.

Kuklev, Nikita [Fermilab]↗

Social impact assessment and public participation in China: A case study of land requisition in Guangzhou

This study examines the current prospects for and obstacles facing the implementation of social impact assessment (SIA) and participatory planning in the People's Republic of China. During the past two decades, rapid urbanisation and the conversion of rural land for urban development have led to numerous social conflicts and tensions between the Chinese government and its people. SIA and public participation in development decisions have received increasing attention from the Chinese authorities as possible ways to tackle the problem. Based on a Guangzhou case study, this paper argues that the assessment and mitigation of adverse impacts on the community from urban development have been carried out with different objectives, core values and principles when compared with those in Western societies. It concludes that the poor prospects of SIA and collaborative planning in China lie not only in the weak framework for environmental legislation, but also in all institutions concerning state-society relations, the socialist governing ideology and traditional Chinese culture.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Data-Driven Models for Predicting Solar Photovoltaics Power Output

This research was undertaken to evaluate different inverse models for predicting power output of solar photovoltaic (PV) systems under different practical scenarios. In particular, we have investigated whether PV power output prediction accuracy can be improved if module/cell temperature was measured in addition to climatic variables, and also the extent to which prediction accuracy degrades if solar irradiation is not measured on the plane of array but only on a horizontal surface. We have also investigated the significance of different independent or regressor variables, such as wind velocity and incident angle modifier in predicting PV power output and cell temperature. The inverse regression model forms have been evaluated both in terms of their goodness-of-fit, and their accuracy and robustness in terms of their predictive performance. Given the accuracy of the measurements, expected CV-RMSE of hourly power output prediction over the year varies between 3.2% and 8.6% when only climatic data are used. Depending on what type of measured climatic and PV performance data is available, different scenarios have been identified and the corresponding appropriate modeling pathways have been proposed. The corresponding models are to be implemented on a controller platform for optimum operational planning of microgrids and integrated energy systems.

14 SOLAR ENERGY↗

Electricity market design for generator revenue sufficiency with increased variable generation

Here, we present a computationally efficient mixed-integer program (MIP) that determines optimal generator expansion decisions, and hourly unit commitment and dispatch in a power system. The impact of increasing wind power capacity on the optimal generation mix and generator profitability is analyzed for a test case that approximates the electricity market in Texas (ERCOT). We analyze three market policies that may support resource adequacy: Operating Reserve Demand Curves (ORDC), Fixed Reserve Scarcity Prices (FRSP) and fixed capacity payments (CP). Optimal expansion plans are comparable between the ORDC and FRSP implementations, while capacity payments may result in additional new capacity. The FRSP policy leads to frequent reserves scarcity events and corresponding price spikes, while the ORDC implementation results in more continuous energy prices. Average energy prices decrease with increasing wind penetration under all policies, as do revenues for baseload and wind generators. Intermediate and peak load plants benefit from higher reserve prices and are less exposed to reduced energy prices. All else equal, an ORDC approach may be preferred to FRSP as it results in similar expansion and revenues with less extreme energy prices. A fixed CP leads to additional new flexible NGCT units, but lower profits for other technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer

Purpose: The aim of this study was to characterize the levels of artifacts and distortions of titanium applicators on 3.0-Tesla magnetic resonance imaging (MRI). Methods and Materials: Fletcher-Suit-Delclos-style tandem and ovoids (T and O) and tandem and ring applicator (T and R) were examined. The quality assurance (QA) phantoms for each applicator were designed and filled with copper sulphate solution (1.5 g/l). The artifacts were quantified with the registration of corresponding computed tomography (CT) images. A favorable MR sequence was searched in terms of artifacts. Using the sequence, the artifacts were determined. The geometric distortions induced by the applicators were quantified through each registration of CT and MRI without applicators. The artifacts of T and O were also evaluated on in vivo MRI datasets of 5 patients. Results: T1-weighted MRI with 1-mm slice thickness was found as a favorable MR sequence. Applying the sequence, the artifacts at the tandem tip of T and O and T and R were determined as 1.5 {+-} 0.5 mm in a superior direction in phantom studies. In the ovoids of T and O, we found artifacts less than 1.5 {+-} 0.5 mm. The artifacts of a T and O tandem in vivo were found as less than 2.6 {+-} 1.3 mm on T1-weighted MRI, whereas less than 6.9 {+-} 3.4 mm on T2-weighted MRI. No more than 1.2 {+-} 0.6 mm (3.0 {+-} 1.5 mm) of distortions, due to a titanium applicator, were measured on T1-weighted MRI (T2-). Conclusion: In 3.0-Tesla MRI, we found the artifact widths at the tip of tandem were less than 1.5 {+-} 0.5 mm for both T and O and T and R when using T1-weighted MRI in phantom studies. However, exclusive 3.0-Tesla MRI-guided brachytherapy planning with a titanium applicator should be cautiously implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Costs and benefits of a school-based health intervention in Portugal

Abstract School-based programmes for preventing childhood obesity have been shown to be effective in improving eating habits and nutritional status, but few intervention programmes with a controlled design have included an economic evaluation. In this study, we conducted a cost-consequence analysis to evaluate the costs and the health benefits of the ‘Planning Health in School’ programme (PHS-pro) implemented in the Northern region of Portugal to 449 children of 10–14 years old. Previous study has showed that after PHS-pro, several anthropometric measures significantly improved in the intervention group (height, waist circumference and waist-height ratio) compared with the control group, followed by significant improvements on soft drinks, fruit and vegetables daily consumptions. Costs were estimated according the two phases of the programme: designing and preparation of schools, and school setting implementation, and included all the direct costs on human and material resources. PHS-pro total costs were estimated as 7915.53€/year with an intervention cost of 36.14€/year/child attending the programme. This is much lower than the direct costs for treating an obese adult in Portugal, which was calculated as 3849.15€/year. A scale-up costing projection for implementing the PHS-pro to a larger young population was estimated to be even lower: 18.18€/year/child. This cost-consequence analysis provided evidence that the PHS-pro was economically feasible especially if compared with the medical costs for treating adult obesity. The PHS-pro can be a beneficial investment and may give a promising contribution to addressing overweight over childhood and adolescence, which are developmental stages that determine adulthood chronic diseases.

Vieira, Margarida↗

A Low-Flow Marine Hydrokinetic Turbine for a Floating Unmanned Mobile Platform

Design and fabrication of a marine hydrokinetic turbine for deployment from a floating unmanned autonomous mobile catamaran platform is described. The objective is to develop a low-flow current turbine for deployment from a floating mobile catamaran USV platform. An undershot water wheel has been selected as the turbine of choice and a WAM-V 16 catamaran has been selected as the USV platform. The concept of operation is that the USV platform would autonomously seek and navigate to a coastal location where coastal or tidal currents may be present, anchor at the location, and deploy the turbine to harness the current energy, convert it to electricity and store it in onboard battery banks. The prototype system being developed is targeted at supporting development of self-powered autonomous mobile recharge stations for unmanned aerial vehicles in coastal zones. Once implemented on the vehicle, open water tests are planned for a range of environmental conditions, involving tidal and coastal currents, and system configurations. The status of the ongoing effort will be discussed.

16 TIDAL AND WAVE POWER↗

The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy

A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is proposed. The GDS algorithm is intrinsically faster than conventional PB algorithms due to approximations in convolution integral, where physical calculations are decoupled from simple grid-to-grid energy transfer. It was effortlessly implemented to a carbon-ion radiotherapy treatment planning system to enable realistic beam blurring in the field, which was absent with the broad-beam (BB) algorithm. For a typical prostate treatment, the slowing factor of the GDS algorithm relative to the BB algorithm was 1.4, which is a great improvement over the conventional PB algorithms with a typical slowing factor of several tens. The GDS algorithm is mathematically equivalent to the PB algorithm for horizontal and vertical coplanar beams commonly used in carbon-ion radiotherapy while dose deformation within the size of the pristine spread occurs for angled beams, which was within 3 mm for a single 150-MeV proton pencil beam of 30 deg. incidence, and needs to be assessed against the clinical requirements and tolerances in practical situations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-18C-01: MRI Safety

Clinical diagnostic medical physicists may be responsible for implementing and maintaining a comprehensive MR safety program. Accrediting bodies including the ACR, IAC, Radsite and The Joint Commission each include aspects of MR Safety into their imaging accreditation programs; MIPPA regulations further raise the significance of non-compliance. In addition, The Joint Commission recently announced New and Revised Diagnostic Imaging Standards for accredited health care organizations which include aspects of MR Safety. Hospitals and clinics look to the physicist to understand guidelines, regulations and accreditation requirements related to MR safety. The clinical medical physicist plays a significant role in a clinical practice by understanding the physical basis for the risks and acting as a facilitator to successfully implement a safety program that provides well-planned siting, allows for the safe scanning of certain implanted devices, and helps radiologists manage specific patient exams. The MRI scanning of specific devices will be discussed including cardiac pacemakers and neurostimulators such as deep brain stimulators. Furthermore for sites involved in MR guided interventional procedures, the MR physicist plays an essential role to establish safe practices. Creating a framework for a safe MRI practice includes the review of actual safety incidents or close calls to determine methods for prevention in the future. Learning Objectives: Understand the requirements and recommendations related to MR safety from accrediting bodies and federal regulations. Understand the Medical Physicist's roles to ensure MR Safety. Identify best practices for dealing with implanted devices, including pacemakers and deep brain stimulators. Review aspects of MR safety involved in an MR guided interventional environment. Understand the important MR safety aspects in actual safety incidents or near misses.

60 APPLIED LIFE SCIENCES↗

SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

AlphaZero Reimplementation with Zoning Game and Associated Materials [SWR-26-016]

Here, we present a de novo, extensible, modular, research-oriented, single-player reimplementation of the "AlphaZero" class of algorithms originally described in [1]. We also present a novel task called the Zoning Game, designed as a toy problem to test the applicability of various AlphaZero-based paradigms to infrastructure planning problems, along with several other games. We implement specializations of AlphaZero to play several games. We also include code that serves as a starting point to explore language generation with AlphaZero, as well as documentation and other related materials. [1] Silver, D., Schrittwieser, J., Simonyan, K., Antonoglou, I., Huang, A., Guez, A., Hubert, T., Baker, L., Lai, M., Bolton, A., Chen, Y., Lillicrap, T., Hui, F., Sifre, L., van den Driessche, G., Graepel, T., & Hassabis, D. (2017). Mastering the game of Go without human knowledge. Nature, 550(7676), 354–359. https://doi.org/10.1038/nature24270

Konar-Steenberg, Gabriel [National Laboratory of t↗

Influence of Spatial Dipole Pattern in Asian Aerosol Changes on East Asian Summer Monsoon

Since China implemented the Air Pollution Prevention and Control Action Plan in 2013, the aerosol emissions in East Asia have been greatly reduced, while emissions in South Asia have continued to increase. This has led to a dipole pattern of aerosol emissions between South Asia and East Asia. We report the East Asian summer monsoon (EASM) responses to the dipole changes in aerosol emissions during 2013–17 are investigated using the atmosphere model of Community Earth System Model version 2 (CESM2). We show that decreases in East Asian emissions alone lead to a positive aerosol effective radiative forcing (ERF) of 1.59 (±0.97) W m -2 over central-eastern China (25°–40°N, 105°–122.5°E), along with a 0.09 (±0.07)°C warming in summer during 2013–17. The warming intensified the land–sea thermal contrast and increased the rainfall by 0.32 (±0.16) mm day -1 . When considering both the emission reductions in East Asia and increases in South Asia, the ERF is increased to 3.39 (±0.89) W m -2 , along with an enhanced warming of 0.20 (±0.08)°C over central-eastern China, while the rainfall insignificant decreased by 0.07 (±0.16) mm day -1 . It is due to the westward shift of the strengthened western Pacific subtropical high, linked to the increase in black carbon in South Asia. Based on multiple EASM indices, the reductions in aerosol emissions from East Asia alone increased the EASM strength by almost 5%. Considering the effect of the westward shift of WPSH, the dipole changes in emissions together increased the EASM by 5%–15% during 2013–17, revealing an important role of South Asian aerosols in changing the East Asian climate.

54 ENVIRONMENTAL SCIENCES↗