Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Lunar Explorer Instrument for space biology Applications (LEIA): An overview of planned science concept of operations

Radiation and reduced gravity pose biological risks to crewed deep space exploration. To better understand deep space radiation biology, the LEIA mission will measure charged particles and fast neutrons as well as yeast growth, metabolic rate, and bioengineered production of carotenoids at the lunar surface. LEIA will be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. The LEIA science concept of operations was developed to isolate radiation and partial gravity from other environmental conditions experienced by the payload. Due to CLPS integration requirements, there will be at least eight months from loading yeast into the payload until activation on the lunar surface. Replicate yeast strains will be loaded in a randomized complete block design to minimize batch differences in desiccation tolerance and positional effects in the microfluidics culture system. Temperature and relative humidity will be controlled throughout integration and flight to maintain yeast viability and to enable measurement of yeast growth parameters within the lunar surface operations timeframe, with the ground control matching environmental conditions where possible. LEIA is co-manifested with the European Space Agency’s PROSPECT mission, which will be operating a drill during yeast growth. Vibration translated through the lunar lander will be mitigated and quantified to account for potential impacts on LEIA optical measurements and yeast growth rate. Total space radiation dose, including the transit exposure from Earth to the Moon, will be measured to obtain more accurate charged particle and fast neutron dose rates on the lunar surface. These radiation data will also yield ground truth radiation dose experienced by the yeast during the mission. Quantifying these environmental factors impacting the LEIA payload will allow more accurate ground control experiments to better isolate the biological responses to radiation and reduced gravity at the lunar surface.

Lunar Surface Mission↗

TU-CD-303-03: Localized Radiation Can Induce Systemic Anti-Cancer Immune and Non-Immune Responses and How We Might Utilize It

Recent advances in cancer research have shed new light on the complex processes of how therapeutic radiation initiates changes at cellular, tissue, and system levels that may lead to clinical effects. These new advances may transform the way we use radiation to combat certain types of cancers. For the past two decades many technological advancements in radiation therapy have been largely based on the hypothesis that direct radiation-induced DNA double strand breaks cause cell death and thus tumor control and normal tissue damage. However, new insights have elucidated that in addition to causing cellular DNA damage, localized therapeutic radiation also initiates cascades of complex downstream biological responses in tissue that extend far beyond where therapeutic radiation dose is directly deposited. For instance, studies show that irradiated dying tumor cells release tumor antigens that can lead the immune system to a systemic anti-cancer attack throughout the body of cancer patient; targeted irradiation to solid tumor also increases the migration of tumor cells already in bloodstream, the seeds of potential metastasis. Some of the new insights may explain the long ago discovered but still unexplained non-localized radiation effects (bystander effect and abscopal effect) and the efficacy of spatially fractionated radiation therapy (microbeam radiation therapy and GRID therapy) where many “hot” and “cold” spots are intentionally created throughout the treatment volume. Better understanding of the mechanisms behind the non-localized radiation effects creates tremendous opportunities to develop new and integrated cancer treatment strategies that are based on radiotherapy, immunology, and chemotherapy. However, in the multidisciplinary effort to advance new radiobiology, there are also tremendous challenges including a lack of multidisciplinary researchers and imaging technologies for the microscopic radiation-induced responses. A better grasp of the essence of these advances in cancer biology research will give medical physicists a new perspective in daily clinical physics practice and in future radiation therapy technological development. Furthermore, academic medical physics should continue to be an integral part of the multidisciplinary cancer research community, harnessing our newly acquired understanding of radiation effects, and developing novel cost-effective treatment strategies to better combat cancer. Learning Objectives: Understand that localized radiation can lead to non-localized secondary effects such as radiation-induced immune response, bystander effect, and abscopal effect. Understand that the non-localized radiation effects may be harnessed to improve cancer treatment. Learn examples of physics participation in multidisciplinary research to advance cancer biology. Recognize the challenges and possibilities of physics applications in cancer research. Chang: NIH 5RC2CA148487-02 and 1U54CA151652-01 Graves: IDEA award (19IB-0106) from the California Breast Cancer Research Program (CBCRP), and by NIH P01 CA67166.

60 APPLIED LIFE SCIENCES↗

TU-CD-303-04: Radiation-Induced Long Distance Tumor Cell Migration Into and Out of the Radiation Field and Its Clinical Implication

Recent advances in cancer research have shed new light on the complex processes of how therapeutic radiation initiates changes at cellular, tissue, and system levels that may lead to clinical effects. These new advances may transform the way we use radiation to combat certain types of cancers. For the past two decades many technological advancements in radiation therapy have been largely based on the hypothesis that direct radiation-induced DNA double strand breaks cause cell death and thus tumor control and normal tissue damage. However, new insights have elucidated that in addition to causing cellular DNA damage, localized therapeutic radiation also initiates cascades of complex downstream biological responses in tissue that extend far beyond where therapeutic radiation dose is directly deposited. For instance, studies show that irradiated dying tumor cells release tumor antigens that can lead the immune system to a systemic anti-cancer attack throughout the body of cancer patient; targeted irradiation to solid tumor also increases the migration of tumor cells already in bloodstream, the seeds of potential metastasis. Some of the new insights may explain the long ago discovered but still unexplained non-localized radiation effects (bystander effect and abscopal effect) and the efficacy of spatially fractionated radiation therapy (microbeam radiation therapy and GRID therapy) where many “hot” and “cold” spots are intentionally created throughout the treatment volume. Better understanding of the mechanisms behind the non-localized radiation effects creates tremendous opportunities to develop new and integrated cancer treatment strategies that are based on radiotherapy, immunology, and chemotherapy. However, in the multidisciplinary effort to advance new radiobiology, there are also tremendous challenges including a lack of multidisciplinary researchers and imaging technologies for the microscopic radiation-induced responses. A better grasp of the essence of these advances in cancer biology research will give medical physicists a new perspective in daily clinical physics practice and in future radiation therapy technological development. Furthermore, academic medical physics should continue to be an integral part of the multidisciplinary cancer research community, harnessing our newly acquired understanding of radiation effects, and developing novel cost-effective treatment strategies to better combat cancer. Learning Objectives: Understand that localized radiation can lead to non-localized secondary effects such as radiation-induced immune response, bystander effect, and abscopal effect. Understand that the non-localized radiation effects may be harnessed to improve cancer treatment. Learn examples of physics participation in multidisciplinary research to advance cancer biology. Recognize the challenges and possibilities of physics applications in cancer research. Chang: NIH 5RC2CA148487-02 and 1U54CA151652-01 Graves: IDEA award (19IB-0106) from the California Breast Cancer Research Program (CBCRP), and by NIH P01 CA67166.

60 APPLIED LIFE SCIENCES↗

Physical and biological studies with protons and HZE particles in a NASA supported research center in radiation health

NASA has established and supports a specialized center for research and training (NSCORT) to specifically address the potential deleterious effects of HZE particles on human health. The NSCORT in radiation health is a joint effort between Lawrence Berkeley National Laboratory (LBNL) and Colorado State University (CSU). The overall scope of research encompasses a broad range of subjects from microdosimetric studies to cellular and tissue responses to initial damage produced by highly energetic protons and heavy charged particles of the type found in galactic cosmic rays (GCR) spectrum. The objectives of the microdosimetry studies are to determine the response of Tissue Equivalent Proportional Counter (TEPC) to cosmic rays using ground based accelerators. This includes evaluation of energy loss due to the escape of high-energy delta rays and increased energy deposition due to the enhanced delta ray production in the wall of the detector. In this report major results are presented for 56Fe at 1000, 740, 600 and 400 MeV/nucleon. An assessment of DNA repair and early development of related chromosomal changes is extremely important to our overall understanding of enhanced biological effectiveness of high LET particle radiation. Results are presented with respect to the fidelity of the rejoining of double strand breaks and the implications of misrejoining. The relationship between molecular and cytogenetic measurements is presented by studying damage processing in highly heterochromatic supernumerary (correction of sypernumerary) X chromosomes and the active X-chromosome. One of the important consequences of cell's inability to handle DNA damage can be evaluated through mutation studies. Part of our goal is the assessment of potential radioprotectors to reduce the mutation yield following HZE exposures, and some promising results are presented on one compound. A second goal is the integration of DNA repair and mutation studies. Results are presented on a direct comparison of initial double strand breaks induction, the time course and fidelity of double strand break rejoining, cell killing and mutation induction in the same human model system. In order to understand the carcinogenic potential of protons and HZE particles, the role of damaged microenvironment in this process must be understood. In this project it has been postulated that radiation affects the microenvironment, which then modifies cell interactions in a manner conducive to neoplastic progression. Both TGF-beta and FGF-2 are important components of microenvironment. A recent result on the assessment of the role of FGF-2 and its cross-talk with TGF-beta as a function of radiation quality is presented. Theoretical modeling has so far played a central role in analyzing and integrating experimental data on repair and mutation studies and predicting new phenomena. The integrated NSCORT program also provides a broad training experience for students and postdoctoral fellows in space radiation health.

NASA Discipline Radiation Health↗

Combined Photon and Electron Three-Dimensional Conformal Versus Intensity-Modulated Radiotherapy With Integrated Boost for Adjuvant Treatment of Malignant Pleural Mesothelioma After Pleuropneumonectomy

Purpose: The optimal technique for postoperative radiotherapy (RT) after extrapleural pleuropneumonectomy (EPP) of malignant pleural mesothelioma (MPM) remains debated. Methods and Materials: The data from 8 right-sided and 9 left-sided consecutive cases of MPM treated with RT after radical EPP were reviewed. Of the 17 patients, 8 had been treated with three-dimensional (3D) conformal RT (3D-CRT) and 9 with intensity-modulated RT (IMRT) with 6-MV photons. The clinical outcome and adverse events were assessed. For comparative planning, each case was replanned with 3D-CRT using photons and electrons or with IMRT. Homogeneity, doses to the organs at risk, and target volume coverage were analyzed. Results: Both techniques yielded acceptable plans. The dose coverage and homogeneity of IMRT increased by 7.7% for the first planning target volume and 9.7% for the second planning target volume, ensuring {>=}95% of the prescribed dose compared with 3D-CRT (p < 0.01). Compared with 3D-CRT, IMRT increased the dose to the contralateral lung, with an increase in the mean lung dose of 7.8 Gy and an increase in the volume receiving 13 Gy and 20 Gy by 20.5% and 7.2%, respectively (p < 0.01). A negligible dose increase to the contralateral kidney and liver was observed. No differences were seen for the spinal cord and ipsilateral kidney. Two adverse events of clinical relevant lung toxicity were observed with IMRT. Conclusion: Intensity-modulated RT and 3D-CRT are both suitable for adjuvant RT. IMRT improves the planning target volume coverage but delivered greater doses to the organs at risk. Rigid dose constraints for the lung should be respected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bioorthogonal catalytic patch

The toxicity and complicated administration procedures of transition metal catalysts have hampered the applications of bioorthogonal catalysis in vivo. Here the authors fill the needles of a microneedle array patch with palladium nanoparticles deposited on titanium nanosheets and show that the device, applied locally on the skin of mouse models bearing melanoma, promotes intratumoural conversion of systemically injected caged doxorubicin into the active drug, reducing its toxicity and side effects. Bioorthogonal catalysis mediated by transition metals has inspired a new subfield of artificial chemistry complementary to enzymatic reactions, enabling the selective labelling of biomolecules or in situ synthesis of bioactive agents via non-natural processes. However, the effective deployment of bioorthogonal catalysis in vivo remains challenging, mired by the safety concerns of metal toxicity or complicated procedures to administer catalysts. Here, we describe a bioorthogonal catalytic device comprising a microneedle array patch integrated with Pd nanoparticles deposited on TiO 2 nanosheets. This device is robust and removable, and can mediate the local conversion of caged substrates into their active states in high-level living systems. In particular, we show that such a patch can promote the activation of a prodrug at subcutaneous tumour sites, restoring its parent drug's therapeutic anticancer properties. Finally, this in situ applied device potentiates local treatment efficacy and eliminates off-target prodrug activation and dose-dependent side effects in healthy organs or distant tissues.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

Ionizing Radiation Environment on the International Space Station: Performance vs. Expectations for Avionics and Material

The role of structural shielding mass in the design, verification, and in-flight performance of International Space Station (ISS), in both the natural and induced orbital ionizing radiation (IR) environments, is reported. Detailed consideration of the effects of both the natural and induced ionizing radiation environment during ISS design, development, and flight operations has produced a safe, efficient manned space platform that is largely immune to deleterious effects of the LEO ionizing radiation environment. The assumption of a small shielding mass for purposes of design and verification has been shown to be a valid worst-case approximation approach to design for reliability, though predicted dependences of single event effect (SEE) effects on latitude, longitude, SEP events, and spacecraft structural shielding mass are not observed. The Figure of Merit (FOM) method over predicts the rate for median shielding masses of about 10g/cm(exp 2) by only a factor of 3, while the Scott Effective Flux Approach (SEFA) method overestimated by about one order of magnitude as expected. The Integral Rectangular Parallelepiped (IRPP), SEFA, and FOM methods for estimating on-orbit (Single Event Upsets) SEU rates all utilize some version of the CREME-96 treatment of energetic particle interaction with structural shielding, which has been shown to underestimate the production of secondary particles in heavily shielded manned spacecraft. The need for more work directed to development of a practical understanding of secondary particle production in massive structural shielding for SEE design and verification is indicated. In contrast, total dose estimates using CAD based shielding mass distributions functions and the Shieldose Code provided a reasonable accurate estimate of accumulated dose in Grays internal to the ISS pressurized elements, albeit as a result of using worst-on-worst case assumptions (500 km altitude x 2) that compensate for ignoring both GCR and secondary particle production in massive structural shielding.

Koontz, Steven L.↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic a human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

Methyl parathion inhibits the nuclear maturation, decreases the cytoplasmic quality in oocytes and alters the developmental potential of embryos of Swiss albino mice

Methyl parathion (MP) is one of the most commonly used and extremely toxic organophosphorous group of pesticide. A large number of studies in the literature suggest that it has adverse effects on the male reproductive system. However, there is limited information about its toxicity to the female reproductive system. In the present study we report the toxic effects of methyl parathion on the female reproductive system using Swiss albino mice as the experimental model. The female mice were administered orally with 5, 10 and 20 mg/kg of MP. One week later, the mice were superovulated with pregnant mare serum gonadotrophin (PMSG) and human chorionic gonadotrophin (hCG) to study the quality of the oocytes, spindle organization, developmental potential of early embryos and the DNA integrity in blastocysts. MP exposure resulted in a non-significant decrease in the number of primordial follicles and increased DNA damage in granulosa cells. Though MP did not have any effect on the ovulation it had a significant inhibitory effect on the nuclear maturity of oocytes which was associated with spindle deformity. In addition, the oocytes had higher cytoplasmic abnormalities with depleted glutathione level. Even though it did not have any effect on the fertilization and blastocyst rate at lower doses, at 20 mg/kg MP it resulted in a significant decrease in blastocyst hatching, decrease in cell number and high DNA damage. While low body weight gain was observed in F1 generation from 5 mg/kg group, at higher dose, the body weight in F1 generation was marginally higher than control. Post-natal death in F1 generation was observed only in mice treated with 20 mg/kg MP. In conclusion, we report that MP has adverse effects on the oocyte quality, developmental potential of the embryo and reproductive outcome. - Highlights: • Methyl parathion induces severe cytoplasmic abnormalities in oocytes. • Inhibits nuclear maturation and spindle damage • Poor blastocyst quality and high DNA damage.

60 APPLIED LIFE SCIENCES↗

Analysis Results for Sub-Samples of SRS Tanks 30, 32, and 39 to Support Evaluations of the I-129 Inventory

In order to appropriately model and predict the chemical integrity and performance of cementitious materials used for waste immobilization at the Savannah River Site (SRS), it is critical to understand the I-129 solubility and distribution within the tank farm. Iodine in radioactive waste and in environmental media is typically highly mobile and long lived. Iodine is ubiquitous in SRS tank waste and waste forms. The iodine is assumed to be soluble and present at low levels in Performance Assessments (PAs) for SRS Tank Farms, and is one of the dose drivers in the PAs for both the SRS Salt Disposal Facility (SDF) and the H-Area Tank Farm (HTF). Analysis of tank waste samples is critical to understanding the Tank Farm iodine inventory and reducing disposal uncertainty. Higher than expected iodine levels have recently been observed in residual solids isolated from some SRS tanks prior to closure, indicating uncertainty regarding the chemical species involved. If the iodine inventory uncertainty is larger than anticipated, future work may be necessary to reduce the uncertainty. This memorandum satisfies a portion of the work scope identified in Task Plan SRNL-RP-2016-00651. A separate memorandum issued previously, reported historical unpublished I-129 data, a significant portion of which was below detectable analytical limits. This memorandum includes iodine and general chemical analysis results for six archived SRNL samples which were previously reported to have I-129 concentrations below detectable limits. Lower sample dilution factors were used for the current analyses in order to obtain concentrations above detection. The samples analyzed included surface and depth samples from SRS tanks 30, 32, and 39.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of One Year of Spaceflight on Neurocognitive Function

It is known that spaceflight adversely affects human sensorimotor function. With interests in longer duration deep space missions it is important to understand microgravity dose-response relationships. NASA's One Year Mission project allows for comparison of the effects of one year in space with those seen in more typical six month missions to the International Space Station. In the Neuromapping project we are performing structural and functional magnetic resonance brain imaging to identify the relationships between changes in neurocognitive function and neural structural alterations following a six month International Space Station mission. Our central hypothesis is that measures of brain structure, function, and network integrity will change from pre- to post-spaceflight. Moreover, we predict that these changes will correlate with indices of cognitive, sensory, and motor function in a neuroanatomically selective fashion. Our interdisciplinary approach utilizes cutting edge neuroimaging techniques and a broad-ranging battery of sensory, motor, and cognitive assessments that are conducted pre-flight, during flight, and post-flight to investigate potential neuroplastic and maladaptive brain changes in crewmembers following long-duration spaceflight. With the one year mission we had one crewmember participate in all of the same measures pre-, per- and post-flight as in our ongoing study. During this presentation we will provide an overview of the magnitude of changes observed with our brain and behavioral assessments for the one year crewmember in comparison to participants that have completed our six month study to date.

Seidler, R. D.↗

TU-CD-303-02: Beyond Radiation Induced Double Strand Breaks - a New Horizon for Radiation Therapy Research

Recent advances in cancer research have shed new light on the complex processes of how therapeutic radiation initiates changes at cellular, tissue, and system levels that may lead to clinical effects. These new advances may transform the way we use radiation to combat certain types of cancers. For the past two decades many technological advancements in radiation therapy have been largely based on the hypothesis that direct radiation-induced DNA double strand breaks cause cell death and thus tumor control and normal tissue damage. However, new insights have elucidated that in addition to causing cellular DNA damage, localized therapeutic radiation also initiates cascades of complex downstream biological responses in tissue that extend far beyond where therapeutic radiation dose is directly deposited. For instance, studies show that irradiated dying tumor cells release tumor antigens that can lead the immune system to a systemic anti-cancer attack throughout the body of cancer patient; targeted irradiation to solid tumor also increases the migration of tumor cells already in bloodstream, the seeds of potential metastasis. Some of the new insights may explain the long ago discovered but still unexplained non-localized radiation effects (bystander effect and abscopal effect) and the efficacy of spatially fractionated radiation therapy (microbeam radiation therapy and GRID therapy) where many “hot” and “cold” spots are intentionally created throughout the treatment volume. Better understanding of the mechanisms behind the non-localized radiation effects creates tremendous opportunities to develop new and integrated cancer treatment strategies that are based on radiotherapy, immunology, and chemotherapy. However, in the multidisciplinary effort to advance new radiobiology, there are also tremendous challenges including a lack of multidisciplinary researchers and imaging technologies for the microscopic radiation-induced responses. A better grasp of the essence of these advances in cancer biology research will give medical physicists a new perspective in daily clinical physics practice and in future radiation therapy technological development. Furthermore, academic medical physics should continue to be an integral part of the multidisciplinary cancer research community, harnessing our newly acquired understanding of radiation effects, and developing novel cost-effective treatment strategies to better combat cancer. Learning Objectives: Understand that localized radiation can lead to non-localized secondary effects such as radiation-induced immune response, bystander effect, and abscopal effect. Understand that the non-localized radiation effects may be harnessed to improve cancer treatment. Learn examples of physics participation in multidisciplinary research to advance cancer biology. Recognize the challenges and possibilities of physics applications in cancer research. Chang: NIH 5RC2CA148487-02 and 1U54CA151652-01 Graves: IDEA award (19IB-0106) from the California Breast Cancer Research Program (CBCRP), and by NIH P01 CA67166.

60 APPLIED LIFE SCIENCES↗

Tumor Volume Combined With Number of Positive Lymph Node Stations Is a More Important Prognostic Factor Than TNM Stage for Survival of Non-Small-Cell Lung Cancer Patients Treated With (Chemo)radiotherapy

Purpose: The current tumor, node, metastasis system needs refinement to improve its ability to predict survival of patients with non-small-cell lung cancer (NSCLC) treated with (chemo)radiation. In this study, we investigated the prognostic value of tumor volume and N status, assessed by using fluorodeoxyglucose-positron emission tomography (PET). Patients and Methods: Clinical data from 270 consecutive patients with inoperable NSCLC Stages I-IIIB treated radically with (chemo)radiation were collected retrospectively. Diagnostic imaging was performed using either integrated PET-computed tomography or computed tomography and PET separately. The Kaplan-Meier method, as well as Cox regression, was used to analyze data. Results: Univariate survival analysis showed that number of positive lymph node stations (PLNSs), as well as N stage on PET, was associated significantly with survival. The final multivariate Cox model consisted of number of PLNSs, gross tumor volume (i.e., volume of the primary tumor plus lymph nodes), sex, World Health Organization performance status, and equivalent radiation dose corrected for time; N stage was no longer significant. Conclusions: Number of PLNSs, assessed by means of fluorodeoxyglucose-PET, was a significant factor for survival of patients with inoperable NSCLC treated with (chemo)radiation. Risk stratification for this group of patients should be based on gross tumor volume, number of PLNSs, sex, World Health Organization performance status, and equivalent radiation dose corrected for time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protection of cisplatin-induced spermatotoxicity, DNA damage and chromatin abnormality by selenium nano-particles

Cisplatin (CIS), an anticancer alkylating agent, induces DNA adducts and effectively cross links the DNA strands and so affects spermatozoa as a male reproductive toxicant. The present study investigated the cellular/biochemical mechanisms underlying possible protective effect of selenium nano-particles (Nano-Se) as an established strong antioxidant with more bioavailability and less toxicity, on reproductive toxicity of CIS by assessment of sperm characteristics, sperm DNA integrity, chromatin quality and spermatogenic disorders. To determine the role of oxidative stress (OS) in the pathogenesis of CIS gonadotoxicity, the level of lipid peroxidation (LPO), antioxidant enzymes including superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GSH-Px) and peroxynitrite (ONOO) as a marker of nitrosative stress (NS) and testosterone (T) concentration as a biomarker of testicular function were measured in the blood and testes. Thirty-two male Wistar rats were equally divided into four groups. A single IP dose of CIS (7 mg/kg) and protective dose of Nano-Se (2 mg/kg/day) were administered alone or in combination. The CIS-exposed rats showed a significant increase in testicular and serum LPO and ONOO level, along with a significant decrease in enzymatic antioxidants levels, diminished serum T concentration and abnormal histologic findings with impaired sperm quality associated with increased DNA damage and decreased chromatin quality. Coadministration of Nano-Se significantly improved the serum T, sperm quality, and spermatogenesis and reduced CIS-induced free radical toxic stress and spermatic DNA damage. In conclusion, the current study demonstrated that Nano-Se may be useful to prevent CIS-induced gonadotoxicity through its antioxidant potential. Highlights: ► Cisplatin (CIS) affects spermatozoa as a male reproductive toxicant. ► Effect of Nano-Se on CIS-induced spermatotoxicity was investigated. ► CIS-exposure induces oxidative sperm DNA damage and impairs steroidogenesis. ► Nano-Se retained sperm quality against CIS-induced free radicals toxic stress.

60 APPLIED LIFE SCIENCES↗

Evaluation of Repurposing Archetypal Preventive Radiological/Nuclear Detectors to the Consequence Management Mission

In the first hours or days after an unplanned release of radioactive material to the environment, the radiation detection instruments most widely available to local first responders may be those currently fielded for interdiction missions. This study investigated how such preventative radiological / nuclear detection instruments could perform if repurposed to consequence management missions. A representative sample of three archetypes (body-worn, human carried, and other/large detection volume) encompassed six categories: personal radiation detector, extended range personal radiation detector, personal emergency radiation detector, radio-isotope identification device, human portable detector/backpack, and vehicle mounted large detection volume. Overall 19 models of equipment were included in the study. Laboratory evaluations were designed to assess the capabilities of the instruments in four consequence management missions: exposure rate, integrated exposure, radiation survey, and contamination screening. As applicable, the evaluations included measurement of exposure rate, integrated exposure, overrange response, and angular response. The results were compared to benchmarks from the American National Standards Institute ANSI N42.49A. The performance of the instruments for initial screening for contamination was assessed by an automated radioactive source moving past the detectors at various speeds and distances. The results demonstrate that if the equipment is used in accordance with the mission analysis and categories, and within the original equipment manufacturer specifications, it is possible to achieve sufficient accuracy to estimate and document doses to responders, plan entries into contaminated areas, detect contamination, and protect the public, until such time as outside resources arrive with sufficient numbers of standard health physics instruments and personnel dosimetry to replace the preventative radiological / nuclear detection instruments. Finally, this evaluation campaign was conducted to complement the National Council on Radiation Protection and Measurements Report-179 on Guidance for Emergency Response Dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗