Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Treatment of Superior Vena Cava (SVC) Syndrome and Inferior Vena Cava (IVC) Thrombosis in a Patient with Colorectal Cancer: Combination of SVC Stenting and IVC Filter Placement to Palliate Symptoms and Pave the Way for Port Implantation

Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement into the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent Implantation for Malignant Pulmonary Artery Stenosis in a Metastasizing Non-Small Cell Bronchial Carcinoma

A 58-year-old patient with recently diagnosed non-small cell bronchial carcinoma was referred to us with increasing shortness of breath and orthopnea by her family practitioner. To exclude the possibility of a pulmonary embolism, contrast medium-enhanced angio-CT of the thorax was performed. This showed a large mediastinal tumor, which, on the one hand, infiltrated and occluded the left upper lobe bronchus and, on the other, constricted the left pulmonary artery over a considerable part of its length. In view of the palliative situation and massively increasing dyspnea, balloon dilatation of the obstructed left pulmonary artery followed by stent placement was performed. This resulted in an immediate improvement of the symptoms. The originally strongly oxygen-dependent and heavily dyspneic patient could be relieved of the external supply of oxygen and was able to sleep normally without additional medication within 24 h. The patient was able ambulate freely within 2 days, with a markedly improved quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?

Current protocols for surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms are mostly based on costly and time-consuming imaging procedures and aim to detect adverse events such as graft migration, endoleaks or aneurysm sac enlargement. These imaging procedures are either associated with radiation exposure to the patients or may be harmful to the patient due to the use of iodine- or gadolinium-containing contrast agents. Furthermore the advantages of EVAR in the short term might be negated by the necessity for endograft surveillance over years. Thus, alternative modalities for follow-up are being investigated. One of these technologies provides pressure information directly from the aneurysm sac. This noninvasive, telemetric pressure sensing was tested in vitro as well as in first clinical trials and was able to identify successful aneurysm exclusion after EVAR. The telemetric pressure sensors showed a promising efficacy and accuracy in detecting type I and type III endoleaks and will help to clarify the clinical relevance of type II endoleaks. This article provides an overview of the in vitro sensors investigated as well as the first clinical trials and the sensors' potential to change the current endograft surveillance regimes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implantable Subcutaneous Venous Access Devices: Is Port Fixation Necessary? A Review of 534 Cases

Conventional surgical technique of subcutaneous venous port placement describes dissection of the port pocket to the pectoralis fascia and suture fixation of the port to the fascia to prevent inversion of the device within the pocket. This investigation addresses the necessity of that step. Between October 8, 2004 and October 19, 2007, 558 subcutaneous chest ports were placed at our institution; 24 cases were excluded from this study. We performed a retrospective review of the remaining 534 ports, which were placed using standard surgical technique with the exception that none were sutured into the pocket. Mean duration of port use, total number of port days, indications for removal, and complications were recorded and compared with the literature. Mean duration of port use was 341 days (182,235 total port days, range 1-1279). One port inversion/flip occurred, which resulted in malfunction and necessitated port revision (0.2%). Other complications necessitating port removal included infection 26 (5%), thrombosis n = 2 (<1%), catheter fracture/pinch n = 1 (<1%), pain n = 2 (<1%), and skin erosion n = 3 (1%). There were two arrhythmias at the time of placement; neither required port removal. The overall complication rate was 7%. The 0.2% incidence of port inversion we report is concordant with that previously published, although many previous reports do not specify if suture fixation of the port was performed. Suture fixation of the port, in our experience, is not routinely necessary and may negatively impact port removal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Alpha Spectrometry Energy Resolution by Ion Implantation with ICP-MS

We report results of a novel technique using an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) as a method of source preparation for alpha spectrometry. This method produced thin, contaminant free 241Am samples which yielded extraordinary energy resolution which appear to be at the lower limit of the detection technology used in this research.

Dion, Michael P.↗

Mg-3Zn/HA Biodegradable Composites Synthesized via Spark Plasma Sintering for Temporary Orthopedic Implants

In the present study, an attempt has been made to improve the mechanical properties, biocompatibility and degradation rate of Mg/3Zn matrix composite, by reinforcing with chemically inert and osteoconductive hydroxyapatite (HA). The composites were synthesized through spark plasma sintering for better consolidation. The HA content, in Mg/3Zn matrix, was optimized with an aim of improving mechanical behavior, corrosion resistance and biocompatibility simultaneously. It has been observed that reinforcement with 15 wt.% HA could slow down the corrosion rate by ~ 60% and improve the hardness and compression strength by ~ 42.8 and 18%, respectively. In vitro studies, up to 56 days, unveil the effect of HA reinforcement in corrosion resistance of magnesium-based matrix. Osteoblastic activity has shown better cell proliferation on the composite surfaces, which were reinforced with HA.

36 MATERIALS SCIENCE↗