Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean↗

Citizen and machine learning-aided high-resolution mapping of urban heat exposure and stress

Abstract Through conversion of land cover to more built-up, impervious surfaces, cities create hotter environments than their surroundings for urban residents, with large differences expected between different parts of the city. Existing measurements of ambient air temperature and heat stress, however, are often insufficient to capture the intra-urban variability in heat exposure. This study provides a replicable method for modeling air temperature, humidity, and moist heat stress over the urban area of Chapel Hill while engaging citizens to collect high-temporal and spatially-resolved air temperature and humidity measurements. We use low-cost, consumer-grade sensors combined with satellite remote sensing data and machine learning to map urban air temperature and relative humidity over various land-cover classes to understand intra-urban spatial variability of ambient heat exposure at a relatively high resolution (10 m). Our findings show that individuals may be exposed to higher levels of air temperature and moist heat stress than weather station data suggest, and that the ambient heat exposure varies according to land cover type, with tree-covered land the coolest and built-up areas the warmest, and time of day, with higher air temperatures observed during the early afternoon. Combining our resulting dataset with sociodemographic data, policymakers and urban planners in Chapel Hill can use data output from this method to identify areas exposed to high temperature and moist heat stress as a first step to design effective mitigation measures.

54 ENVIRONMENTAL SCIENCES↗

High-throughput identification of novel heat tolerance genes via genome-wide pooled mutant screens in the model green alga Chlamydomonas reinhardtii

Different high temperatures adversely affect crop and algal yields with various responses in photosynthetic cells. The list of genes required for thermotolerance remains elusive. Additionally, it is unclear how carbon source availability affects heat responses in plants and algae. Here, we utilized the insertional, indexed, genome-saturating mutant library of the unicellular, eukaryotic green alga Chlamydomonas reinhardtii to perform genome-wide, quantitative, pooled screens under moderate (35°C) or acute (40°C) high temperatures with or without organic carbon sources. We identified heat-sensitive mutants based on quantitative growth rates and identified putative heat tolerance genes (HTGs). By triangulating HTGs with heat-induced transcripts or proteins in wildtype cultures and MapMan functional annotations, we presented a high/medium-confidence list of 933 Chlamydomonas genes with putative roles in heat tolerance. Triangulated HTGs include those with known thermotolerance roles and novel genes with little or no functional annotation. About 50% of these high-confidence HTGs in Chlamydomonas have orthologs in green lineage organisms, including crop species. Arabidopsis thaliana mutants deficient in the ortholog of a high-confidence Chlamydomonas HTG were also heat sensitive. This work expands our knowledge of heat responses in photosynthetic cells and provides engineering targets to improve thermotolerance in algae and crops.

59 BASIC BIOLOGICAL SCIENCES↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing particle-to-sCO2 heat exchanger effectiveness through novel high-porosity metallic foams

In this project, a novel concept of Octet-shape based lattice frame material was developed for deployment in particle-to-sCO2 heat exchangers for CSP application. A comprehensive experimental and numerical program was performed to investigate and characterize the thermal and flow transport behavior in high porosity lattice frame material. The thermal properties include effective thermal conductivity and interstitial heat transfer coefficient and flow properties including permeability and inertial coefficient. Above quantities were determined for both air flow and heated particle flow through the porous channels which were representative of the hot channel in a typical counter flow heat exchanger. The cold side of the heat exchanger feature minichannels which are known to be very efficient in thermal transport. The goal of this project was to enhance the overall heat transfer coefficient (Up) on the hot side by introducing Octet-shape based lattice frame material through enhancement in effective thermal conductivity of the channel and through enhancement in the interstitial heat transfer coefficient.

14 SOLAR ENERGY↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for CSP- Fabrication and Testing of Receiver Design Feature Specimens in a Simulating Lab Test via Laser Heating

Critical to the creation of a multi-component SiC receiver design concept capable of meeting the SETO CST cost goal objectives of <$150/kWth is the optimal utilization of material for solar absorption and heat transfer to transport fluid. This is to maximize the solar-thermal efficiency in the techno-economic analysis of derived use case. As a first step in preparation of sub-component design for on-sun test evaluations we use different proposed SiC absorber element in a customized laser heat flux test to assess an effective heat transfer coefficient characteristic of the design. The test results are analyzed to extract the effective heat transfer coefficient, thus enable optimization of the geometry of receiver components for heat transfer, efficiency attributes and the thermo-structural management of the components. High intensity CO2 laser is used in combination with air flow through the test specimen to assess the effective heat transfer coefficient under heat flux conditions corresponding to high solar concentrations in the range of 1000-2000 suns.

14 SOLAR ENERGY↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This paper investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗

Parameterized Study of Heat Load Trends in a Subscale Rotating Detonation Rocket Engine

NASA has developed a subscale rotating detonation rocket engine platform, enabling rapid parameterization of components and their associated performances. A major performance metric of interest for RDREs is the total heat absorbed at a given operating condition and wave mode operation. To investigate this, several sets of hardware were produced to have variation of the contraction ratio, injector geometry, and length. A wide range of total mass flow rates and mixture ratios were also explored using gaseous methane/oxygen. All hardware was produced using laser powder bed fusion GRCop-42, GRX-810, or C-103 alloys depending on the component cooling requirements. Outer and inner body hardware were made from GRCop-42 where heat fluxes were expected to be high and were water cooled through integrated coolant channels. Nozzles were made from C-103 which are radiatively cooled. Finally, the injectors were produced using GRCop-42 or GRX-810 as passive cooling via propellant injection has previously found to be sufficient given the small gap width of exposed injection surface. Total heat load and bulk heat flux measurements to the hot walls are reported. Trends in heat load and heat flux are shown with relation to parameters such as chamber pressure, area ratio, and wave mode. Heat loads between the inner and outer bodies and the chamber and shroud section are compared.

Heat Flux↗

Parameterized Study of Heat Load Trends in a Subscale Rotating Detonation Rocket Engine

NASA has developed a subscale rotating detonation rocket engine platform, enabling rapid parameterization of components and their associated performances. A major performance metric of interest for RDREs is the total heat absorbed at a given operating condition and wave mode operation. To investigate this, several sets of hardware were produced to have variation of the contraction ratio, injector geometry, and length. A wide range of total mass flow rates and mixture ratios were also explored using gaseous methane/oxygen. All hardware was produced using laser powder bed fusion GRCop-42, GRX-810, or C-103 alloys depending on the component cooling requirements. Outer and inner body hardware were made from GRCop-42 where heat fluxes were expected to be high and were water cooled through integrated coolant channels. Nozzles were made from C-103 which are radiatively cooled. Finally, the injectors were produced using GRCop-42 or GRX-810 as passive cooling via propellant injection has previously found to be sufficient given the small gap width of exposed injection surface. Total heat load and bulk heat flux measurements to the hot walls are reported. Trends in heat load and heat flux are shown with relation to parameters such as chamber pressure, area ratio, and wave mode. Heat loads between the inner and outer bodies and the chamber and shroud section are compared.

Heat Loads↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is finding energy efficiency home heating technologies such as ductless air source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) has allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs which will help to inform future heat pump deployment efforts in the area.

air source heat pump↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University: Preprint

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ("CUBO") was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ('CUBO') was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗