Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Transbrachial Access for Radiologic Manipulation of Problematic Central Venous Catheters in a Pediatric Population

A transfemoral venous approach is the current standard for accessing malpositioned and fractured central venous catheters (CVCs). The purpose of this study was (1) to describe a transbrachial approach for correction and (2) to assess the success and failure of this method in a pediatric population. A 12-year retrospective review of all patients referred for correction of malpositioned, retained, and fractured CVCs was conducted. Based on the performing interventionalist's preference, transbrachial or transfemoral venous sheaths where placed under ultrasonographic guidance. Diagnostic angiographic catheters and snares were used to manipulate the catheters. Patients who underwent the transfemoral approach received postprocedural monitoring for 4 hours, whereas patients who underwent the transbrachial approach were allowed unrestricted activity immediately after hemostasis was obtained. Technical success of malpositioned lines was defined (1) by final position in the superior vena cava or at the cavoatrial junction on postprocedural imaging or (2) by successful removal of retained catheter fragments, if present. Transbrachial approach was used for access in 11 patients. Problematic lines included malpositioned (n = 10) and retained (n = 1) lines. The ipsilateral arm was used for transbrachial entry in 7 patients. Initial use of angiographic catheters was attempted in 7 cases, of which 4 were successful. All 3 unsuccessful cases had tips positioned in the contralateral brachiocephalic vein, and these were successfully repositioned using snares. A combination of snares and angiographic catheters was used in 2 cases. Snares were used for all other cases. Technical success by way of the transbrachial approach was observed in all cases. Periprocedural follow-up demonstrated no immediate complications. We conclude that the transbrachial approach is a suitable alternative to the transfemoral approach for catheter tip position correction. Tip malposition in the contralateral brachiocephalic vein suggests higher rate of conversion to use of snare devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patients with Life-Threatening Arterial Renal Hemorrhage: CT Angiography and Catheter Angiography with Subsequent Superselective Embolization

The purpose of this study was to evaluate the technical and clinical success of superselective embolization in patients with life-threatening arterial renal hemorrhage undergoing preinterventional CT angiography. Forty-three patients with clinical signs of life-threatening arterial renal hemorrhage underwent CT angiography and catheter angiography. Superselective embolization was indicated in the case of a positive catheter angiography. Primary study goals were technical and clinical success of superselective embolization. Secondary study goals were CT angiographic and catheter angiographic image findings and clinical follow-up. The mean time interval between CT angiography and catheter angiography was 8.3 {+-} 10.3 h (range, 0.2-34.1 h). Arterial renal hemorrhage was identified with CT angiography in 42 of 43 patients (98%) and catheter angiography in 39 of 43 patients (91%) (overview angiography in 4 of 43 patients [9%], selective angiography in 16 of 43 patients [37%], and superselective angiography in 39 of 43 patients [91%]). Superselective embolization was performed in 39 of 43 patients (91%) and technically successful in 37 of 39 patients (95%). Therefore, coil embolization was performed in 13 of 37 patients (35%), liquid embolization in 9 of 37 patients (24%), particulate embolization in 1 of 37 patients (3%), and a combination in 14 of 37 patients (38%). Clinical failure occurred in 8 of 39 patients (21%) and procedure-related complications in 2 of 39 patients (5%). The 30-day mortality rate was 3%. Hemoglobin decreased significantly prior to intervention (P < 0.001) and increased significantly after intervention (P < 0.005). In conclusion, superselective embolization is effective, reliable, and safe in patients with life-threatening arterial renal hemorrhage. In contrast to overview and selective angiography, only superselective angiography allows reliable detection of arterial renal hemorrhage. Preinterventional CT angiography is excellent for detection and localization of arterial renal hemorrhage and appropriate for guidance of the embolization procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irreversible Electroporation in a Swine Lung Model

Purpose: This study was designed to evaluate the safety and tissue effects of IRE in a swine lung model. Methods: This study was approved by the institutional animal care committee. Nine anesthetized domestic swine underwent 15 percutaneous irreversible electroporation (IRE) lesion creations (6 with bipolar and 3 with 3-4 monopolar electrodes) under fluoroscopic guidance and with pancuronium neuromuscular blockade and EKG gating. IRE electrodes were placed into the central and middle third of the right mid and lower lobes in all animals. Postprocedure PA and lateral chest radiographs were obtained to evaluate for pneumothorax. Three animals were sacrificed at 2 weeks and six at 4 weeks. Animals underwent high-resolution CT scanning and PA and lateral radiographs 1 h before sacrifice. The treated lungs were removed en bloc, perfused with formalin, and sectioned. Gross pathologic and microscopic changes after standard hematoxylin and eosin staining were analyzed within the areas of IRE lesion creation. Results: No significant adverse events were identified. CT showed focal areas of spiculated high density ranging in greatest diameter from 1.1-2.2 cm. On gross inspection of the sectioned lung, focal areas of tan discoloration and increased density were palpated in the areas of IRE. Histological analysis revealed focal areas of diffuse alveolar damage with fibrosis and inflammatory infiltration that respected the boundaries of the interlobular septae. No pathological difference could be discerned between the 2- and 4-week time points. The bronchioles and blood vessels within the areas of IRE were intact and did not show signs of tissue injury. Conclusion: IRE creates focal areas of diffuse alveolar damage without creating damage to the bronchioles or blood vessels. Short-term safety in a swine model appears to be satisfactory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Devascularization of Head and Neck Paragangliomas by Direct Percutaneous Embolization

Preoperative transarterial embolization of head and neck paragangliomas using particulate agents has proven beneficial for decreasing intraoperative blood loss. However, the procedure is often incomplete owing to extensive vascular structure and arteriovenous shunts. We report our experience with embolization of these lesions by means of direct puncture and intratumoral injection of n-butyl cyanoacrylate (NBCA) or Onyx. Ten patients aged 32-82 years who were referred for preoperative embolization of seven carotid body tumors and three jugular paragangliomas were retrospectively analyzed. Intratumoral injections were primarily performed in four cases with multiple small-caliber arterial feeders and adjunctive to transarterial embolization in six cases with incomplete devascularization. Punctures were performed under ultrasound and injections were performed under roadmap fluoroscopic guidance. Detailed angiographies were performed before and after embolization procedures. Control angiograms showed complete or near-complete devascularization in all tumors. Three tumors with multiple small-caliber arterial feeders were treated with primary NBCA injections. One tumor necessitated transarterial embolization after primary injection of Onyx. Six tumors showed regional vascularization from the vasa vasorum or small-caliber branches of the external carotid artery following the transarterial approach. These regions were embolized with NBCA injections. No technical or clinical complications related to embolization procedures occurred. All except one of the tumors were surgically removed following embolization. In conclusion, preoperative devascularization with percutaneous direct injection of NBCA or Onyx is feasible, safe, and effective in head and neck paragangliomas with multiple small-caliber arterial feeders and in cases of incomplete devascularization following transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation of the Small Saphenous Vein Sparing the Saphenopopliteal Junction

To assess outcomes after endovenous laser ablation (EVLA) of the small saphenous vein (SSV). Retrospective review was performed of all consecutive EVLA procedures performed over a 39-month period at three neighboring vein practices for symptomatic, duplex ultrasound-proven incompetence of the SSV. EVLA was performed under ultrasound guidance with an 810- or 980-nm diode laser in continuous mode using the pullback method while sparing the deep, most cephalad segment of the SSV near the saphenopopliteal junction. Follow-up after EVLA included patient symptoms, physical examination, and duplex ultrasound. Pretreatment variables were similar across all three practices. EVLA was performed to treat 67 incompetent SSVs in 63 patients (86% women; mean age and 95% confidence interval, 50 {+-} 3 years; range, 20-82 years). Average energy delivered was 92 J/cm. Immediate technical success and occlusion of the treated vein at 1-2 weeks was 100%. Imaging follow-up length was 243 {+-} 65 days (range, 3-893 days). Clinical follow-up (243 {+-} 66 days) showed symptomatic improvement in 66 (99%) of 67 patients; one patient had recanalization with recurrent reflux by ultrasound (2%). Complications included one case of paresthesias lasting beyond 1 month of follow-up (2%) and three cases of superficial phlebitis (4%), but no deep vein thrombosis, skin burns, or other complications. Although ablation involved only the superficial portion of the SSV and spared its deep segment in the popliteal fossa, SSV occlusion typically extended up to the saphenopopliteal junction or to a gastrocnemial collateral, without popliteal vein involvement. EVLA of the SSV is safe and effective when the saphenopopliteal junction and popliteal fossa are avoided. This approach may help reduce the risk of paresthesias or other complications while maintaining low recanalization rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Complications of Femoral Arterial Access

Endovascular repair of femoral arterial access complications is nowadays the treatment of choice in a group of patients who cannot tolerate vascular reconstruction and bleeding due to advanced cardiovascular disease. Endovascular procedures can be performed under local anesthesia, are well tolerated by the patient, and are associated with a short hospitalization time. Ninitinol stent technology allows for safe stent and stent-graft extension at the common femoral artery (CFA) level, due to increased resistance to external compression and bending stress. Active pelvic bleeding can be insidious, and prompt placement of a stent-graft at the site of leakage is a lifesaving procedure. Percutaneous thrombin injection under US guidance is the treatment of choice for femoral pseudoaneurysms (PAs); this can theoretically be safer with simultaneous balloon occlusion across the entry site of a PA without a neck or with a short and wide neck. In a few cases with thrombin failure due to a large arterial defect or accompanying arteriovenous fistula (AVF), a stent-graft can be deployed. The vast majority of catheter-induced AVFs can be treated effectively with stent-graft implantation even if they are located very close to the femoral bifurcation. Obstructive dissection flaps localized in the CFA are usually treated with prolonged balloon inflation; however, in more extensive dissections involving iliac arteries, self-expanding stents should be deployed. Iliofemoral thrombosis can be treated effectively with catheter-directed thrombolysis (CDT) followed by prolonged balloon inflation or stent placement. Balloon angioplasty and CDT can occasionally be used to treat stenoses and occlusions complicating the use of percutaneous closure devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Access to the Cisterna Chyli: Introduction of a Technique for Direct Lymphangiography to Evaluate and Treat Chylothorax

The purpose of this report is to introduce a technique of direct lymphangiography to enable chylothorax treatment. Using a hybrid computed tomography (CT) and fluoroscopy imaging system, a 21-gauge needle was placed under CT guidance into the cisterna chyli to allow contrast lymphangiography and CT lymphangiography in two patients with presumed postoperative chylothorax. Water-soluble contrast media injection demonstrated the thoracic duct anatomy in both patients. Further successful needle disruption of the cisterna chyli was performed in one patient to interrupt lymph flow and stop the chylous leak, with subsequent resolution of the chylothorax.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spontaneous Regression of Multiple Pulmonary Metastases After Radiofrequency Ablation of a Single Metastasis

We report two cases of spontaneous regression of multiple pulmonary metastases occurring after radiofrequency ablation (RFA) of a single lung metastasis. To the best of our knowledge, these are the first such cases reported. These two patients presented with lung metastases progressive despite treatment with interleukin-2, interferon, or sorafenib but were safely ablated with percutaneous RFA under computed tomography guidance. Percutaneous RFA allowed control of the targeted tumors for >1 year. Distant lung metastases presented an objective response despite the fact that they received no targeted local treatment. Local ablative techniques, such as RFA, induce the release of tumor-degradation product, which is probably responsible for an immunologic reaction that is able to produce a response in distant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26-52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Image-Guided Management of a Uterine Arteriovenous Malformation

The investigators present a novel image-guided embolization, not previously described, of a uterine arteriovenous malformation (AVM) resistant to endovascular management. The uterus was exposed surgically, and Histoacryl (Braun, Fulda, Germany) was injected directly into the nidus using ultrasound guidance and fluoroscopy. The patient had a successful full-term pregnancy after this procedure. This technique may be a useful alternative management strategy in patients with uterine AVM who fail traditional endovascular embolization and who still desire fertility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display the septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transthoracic Computed Tomography-Guided AICD Insertion in a Patient with Extracardiac Fontan Conduit

Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner

Purpose: The aim of this work was to develop and test a general methodology for the planning and performance of robot-assisted, MR-guided interventions. This methodology also includes the employment of software tools with appropriately tailored routines to effectively exploit the capabilities of MRI and address the relevant spatial limitations. Methods: The described methodology consists of: (1) patient-customized feasibility study that focuses on the geometric limitations imposed by the gantry, the robotic hardware, and interventional tools, as well as the patient; (2) stereotactic preoperative planning for initial positioning of the manipulator and alignment of its end-effector with a selected target; and (3) real-time, intraoperative tool tracking and monitoring of the actual intervention execution. Testing was performed inside a standard 1.5T MRI scanner in which the MR-compatible manipulator is deployed to provide the required access. Results: A volunteer imaging study demonstrates the application of the feasibility stage. A phantom study on needle targeting is also presented, demonstrating the applicability and effectiveness of the proposed preoperative and intraoperative stages of the methodology. For this purpose, a manually actuated, MR-compatible robotic manipulation system was used to accurately acquire a prescribed target through alternative approaching paths. Conclusions: The methodology presented and experimentally examined allows the effective performance of MR-guided interventions. It is suitable for, but not restricted to, needle-targeting applications assisted by a robotic manipulation system, which can be deployed inside a cylindrical scanner to provide the required access to the patient facilitating real-time guidance and monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Session Radiofrequency Ablation of Bilateral Lung Metastases

Purpose: This retrospective study examined the feasibility and efficacy of bilateral lung radiofrequency ablation (RFA) performed in a single session. Methods: From 2002-2009, patients with bilateral lung metastases were treated by RFA, where possible in a single session under general anesthesia with CT guidance. The second lung was punctured only if no complications occurred after treatment of the first lung. Five lung metastases maximum per patient were treated by RFA and prospectively followed. The primary endpoint was the evaluation of acute and delayed complications. Secondary endpoints were calculation of hospitalization duration, local efficacy, median survival, and median time to tumor progression. Local efficacy was evaluated on CT or positron emission tomography (PET) CT. Results: Sixty-seven patients were treated for bilateral lung metastases with RFA (mean age, 62 years). Single-session treatment was not possible in 40 due to severe pneumothoraces (n = 24), bilateral pleural contact (n = 14), and operational exclusions (n = 2). Twenty-seven (41%) received single-session RFA of lesions in both lungs for 66 metastases overall. Fourteen unilateral and four bilateral pneumothoraces occurred (18 overall, 66.7%). Unilateral (n = 13) and bilateral (n = 2) chest tube drainage was required. Median hospitalization was 3 (range, 2-8) days. Median survival was 26 months (95% confidence interval (CI), 19-33). Four recurrences on RFA sites were observed (4 patients). Median time to tumor progression was 9.5 months (95% CI, 4.2-23.5). Conclusions: Although performing single-session bilateral lung RFA is not always possible due to pneumothoraces after RFA of first lung, when it is performed, this technique is safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗