Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Decays of B_s Mesons and b Baryons: A Review of Recent First Observations and Branching Fractions

Recent rate measurements of B{sub s}{sup 0} mesons and {Lambda}{sub b}{sup 0} baryons produced in {radical}s = 1.96 TeV proton-antiproton and {Upsilon}(5S) electron-positron collisions are reviewed, including the first observations of six new decay modes: B{sub s}{sup 0} {yields} D{sub s}{sup +} K{sup -} (CDF), B{sub s}{sup 0} {yields} D{sub s}{sup -} D{sub s}{sup +} (CDF), B{sub s}{sup 0} {yields} D{sub s1}{sup -}(2536){mu}{sup +} {nu}{sub {mu}} X (DZero), B{sub s}{sup 0} {yields} {phi}{gamma} (Belle)< {Lambda}{sub b}{sup 0} {yields} p{pi}{sup -} (CDF), and {Lambda}{sub b}{sup 0} {yields} pK{sup -} (CDF). Also examined are branching-fraction measurements or limits for the B{sub s}{sup 0} {yields} D{sub s}{sup (*)} D{sub s}{sup (*)} modes (Belle, CDF, and DZero), the B{sub s}{sup 0} {yields} {gamma}{gamma} radiative penguin decay (Belle), and three two-body charmless B{sub s}{sup 0} meson decay channels (CDF). Implications for the phenomenology of electroweak and QCD physics, as well as searches for physics beyond the Standard Model, are identified where applicable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tailpulse signal generator

A tailpulse signal generating/simulating apparatus, system, and method designed to produce electronic pulses which simulate tailpulses produced by a gamma radiation detector, including the pileup effect caused by the characteristic exponential decay of the detector pulses, and the random Poisson distribution pulse timing for radioactive materials. A digital signal process (DSP) is programmed and configured to produce digital values corresponding to pseudo-randomly selected pulse amplitudes and pseudo-randomly selected Poisson timing intervals of the tailpulses. Pulse amplitude values are exponentially decayed while outputting the digital value to a digital to analog converter (DAC). And pulse amplitudes of new pulses are added to decaying pulses to simulate the pileup effect for enhanced realism in the simulation.

47 OTHER INSTRUMENTATION↗

Gamma-ray pulsars: Radiation processes in the outer magnetosphere

We describe an emission model for gamma ray pulsars based on curvature radiation-reaction limited charges in the outer magnetosphere. We show how pair production on thermal surface flux can limit the acceleration zones. Estimates for the efficiency of GeV photon production eta gamma and the gamma-ray beaming fraction are derived, including their dependence on pulsar parameters. In general eta gamma increases with pulsar age, but is decreased for low magnetic fields and for small magnetic inclinations. We argue that this produces GeV pulse profiles, curvature spectra and detection statistics consistent with the observations. We also describe the optical through X-ray pulsar synchrotron spectrum and the spectral variations with pulsar phase. A test computation for Vela-like parameters reproduces phase-resolved GeV spectra consistent with those observed by EGRET. Finally we comment on very high energy pulsed emission and particle production and note extensions needed to allow a more complete pulsar model.

Romani, Roger W.↗

Dynamics of Changes in the Photoluminescence of Porous Silicon after Gamma Irradiation

Radiation stability of the nanoporous silicon under gamma irradiation was investigated. Changes in the properties of porous silicon under gamma irradiation were registered by measurements of photoluminescence spectra and Fourier-transform infrared (FTIR) spectroscopy. Besides the appearance of point defects and their subsequent oxidation, the significant differences were shown to be in the behavior of the porous silicon properties in comparison with that of bulk silicon apparently due to the quantum size nature of nanoporous silicon.

36 MATERIALS SCIENCE↗

The nature of the annihilation radiation and gamma-ray continuum from the Galactic center region

Analysis of the observations of the time-dependent, electron-positron annihilation line radiation and gamma-ray continuum emission from the region of the Galactic center shows that ther are two components to the emission: (1) a variable, compact source of 511 keV annihilation line and higher energy continuum emission active from about 1977 through 1979 at or near the Galactic center; and (2) a steady, diffuse interstellar source of 511 keV annihilation line and orthopositronium continuum emission, having a galactic longitudinal distribution consistent with that of the more than 70 MeV gamma rays or the molecular (CO) gas. It is found that the continuum spectrum of the compact source shows no evidence for orthopositronium annihilation. It is suggested that all of the three-photon orthopositronium continuum observed so far originates from the diffuse interstellar component. The continuum spectrum of the compact source is very similar to that of the black-hole candidate Cygnus X-1, supporting our earlier arguments that this object, at or near the Galactic center, is a black hole of stellar mass.

Lingenfelter, Richard E.↗

The effect of geological and geographical features on environmental radiation

The gamma-ray dose rates were measured in Gifu and Tokushima Prefectures in Japan. Measurements were carried out by the car-borne survey method. The dose rate in basaltic terrain in Tokushima prefecture was almost same as average of basaltic terrain in Japan. On the other hand, the dose rate in basaltic terrain in Gifu Prefecture was not same. In situ measurement of terrestrial gamma-ray dose rate was carried out in this terrain to examine its cause. As a result, it was estimated that soil of rhyolite which attributed to neighbor terrain have deposited on this terrain.

54 ENVIRONMENTAL SCIENCES↗

Radiation burst from a single {gamma}-photon field

The radiation burst from a single {gamma}-photon field interacting with a dense resonant absorber is studied theoretically and experimentally. This effect was discovered for the fist time by P. Helisto et al.[Phys. Rev. Lett. 66, 2037 (1991)] and it was named the ''gamma echo''. The echo is generated by a 180 Degree-Sign phase shift of the incident radiation field, attained by an abrupt change of the position of the absorber with respect to the radiation source during the coherence time of the photon wave packet. Three distinguishing cases of the gamma echo are considered; i.e., the photon is in exact resonance with the absorber, close to resonance (on the slope of the absorption line), and far from resonance (on the far wings of the resonance line). In resonance the amplitude of the radiation burst is two times larger than the amplitude of the input radiation field just before its phase shift. This burst was explained by Helisto et al. as a result of constructive interference of the coherently scattered field with the phase-shifted input field, both having almost the same amplitude. We found that out of resonance the scattered radiation field acquires an additional component with almost the same amplitude as the amplitude of the incident radiation field. The phase of the additional field depends on the optical thickness of the absorber and resonant detuning. Far from resonance this field interferes destructively with the phase-shifted incident radiation field and radiation quenching is observed. Close to resonance the three fields interfere constructively and the amplitude of the radiation burst is three times larger than the amplitude of the input radiation field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Annihilation radiation in cosmic gamma-ray bursts

The pair annihilation radiation in gamma-ray bursts is seen as broad lines with extended hard wings. This radiation is suggested to escape in a collimated beam from magnetic polar regions of neutron stars.

Aptekar, R. L.↗

Mechanism of Action for Anti-radiation Vaccine in Reducing the Biological Impact of High-dose Gamma Irradiation

Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then collected and circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naive animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which the mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

Maliev, Vladislav↗

Semiquantitative Analysis Using Thallium-201 SPECT for Differential Diagnosis Between Tumor Recurrence and Radiation Necrosis After Gamma Knife Surgery for Malignant Brain Tumors

Purpose: Semiquantitative analysis of thallium-201 chloride single photon emission computed tomography ({sup 201}Tl SPECT) was evaluated for the discrimination between recurrent brain tumor and delayed radiation necrosis after gamma knife surgery (GKS) for metastatic brain tumors and high-grade gliomas. Methods and Materials: The medical records were reviewed of 75 patients, including 48 patients with metastatic brain tumor and 27 patients with high-grade glioma who underwent GKS in our institution, and had suspected tumor recurrence or radiation necrosis on follow-up neuroimaging and deteriorating clinical status after GKS. Analysis of {sup 201}Tl SPECT data used the early ratio (ER) and the delayed ratio (DR) calculated as tumor/normal average counts on the early and delayed images, and the retention index (RI) as the ratio of DR to ER. Results: A total of 107 tumors were analyzed with {sup 201}Tl SPECT. Nineteen lesions were removed surgically and histological diagnoses established, and the other lesions were evaluated with follow-up clinical and neuroimaging examinations after GKS. The final diagnosis was considered to be recurrent tumor in 65 lesions and radiation necrosis in 42 lesions. Semiquantitative analysis demonstrated significant differences in DR (P=.002) and RI (P<.0001), but not in ER (P=.372), between the tumor recurrence and radiation necrosis groups, and no significant differences between metastatic brain tumors and high-grade gliomas in all indices (P=.926 for ER, P=.263 for DR, and P=.826 for RI). Receiver operating characteristics analysis indicated that RI was the most informative index with the optimum threshold of 0.775, which provided 82.8% sensitivity, 83.7% specificity, and 82.8% accuracy. Conclusions: Semiquantitative analysis of {sup 201}Tl SPECT provides useful information for the differentiation between tumor recurrence and radiation necrosis in metastatic brain tumors and high-grade gliomas after GKS, and the RI may be the most valuable index for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and Clinical Analysis of Spatial Distribution of the Radiation Dose in Gamma Knife Radiosurgery for Vestibular Schwannoma

Objectives: We investigated variations in the distribution of radiation dose inside (dose inhomogeneity) and outside (dose falloff) the target volume during Gamma Knife (GK) irradiation of vestibular schwannoma (VS). We analyzed the relationship between some parameters of dose distribution and the clinical and radiological outcome of patients. Methods and Materials: Data from dose plans of 203 patients treated for a vestibular schwannoma by GK C using same prescription dose (12 Gy at the 50% isodose) were collected. Four different dosimetric indexes were defined and calculated retrospectively in all plannings on the basis of dose-volume histograms: Paddick conformity index (PI), gradient index (GI), homogeneity index (HI), and unit isocenter (UI). The different measures related to distribution of the radiation dose were compared with hearing and tumor outcome of 203 patients with clinical and radiological follow-up of minimum 2 years. Results: Mean, median, SD, and ranges of the four indexes of dose distribution analyzed were calculated; large variations were found between dose plans. We found a high correlation between the target volume and PI, GI, and UI. No significant association was found between the indexes of dose distribution calculated in this study and tumor control, tumor volume shrinkage, hearing worsening, loss of functional hearing, or complete hearing loss at last follow-up. Conclusions: Parameters of distribution of the radiation dose during GK radiosurgery for VS can be highly variable between dose plans. The tumor and hearing outcome of patients treated is not significantly related to these global indexes of dose distribution inside and around target volume. In GK radiosurgery for VS, the outcome seems more to be influenced by local radiation dose delivered to specific structures or volumes than by global dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for Dimuon Decays of a Light Scalar Boson in Radiative Transitions UPSILON->gammaA{sup 0}

We search for evidence of a light scalar boson in the radiative decays of the UPSILON(2S) and UPSILON(3S) resonances: UPSILON(2S,3S)->gammaA{sup 0}, A{sup 0}->mu{sup +}mu{sup -}. Such a particle appears in extensions of the standard model, where a light CP-odd Higgs boson naturally couples strongly to b quarks. We find no evidence for such processes in the mass range 0.212<=m{sub A}{sup 0}<=9.3 GeV in the samples of 99x10{sup 6} UPSILON(2S) and 122x10{sup 6} UPSILON(3S) decays collected by the BABAR detector at the SLAC PEP-II B factory and set stringent upper limits on the effective coupling of the b quark to the A{sup 0}. We also limit the dimuon branching fraction of the eta{sub b} meson: B(eta{sub b}->mu{sup +}mu{sup -})<0.9% at 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of laser radiation on the gamma activity of aqueous salt solutions containing {sup 152}Eu

We report an experimental study of the effect of laser irradiation of aqueous salt solutions containing the {sup 152}Eu isotope in the presence of nickel nanoparticles on the gamma activity of the isotope. Nickel nanoparticles are generated using laser ablation of the target in water and added to the radionuclide solution before irradiation. Two types of Nd : YAG lasers with a pulse duration of 10 ns and different repetition rates are used to irradiate the solutions. It is found that the {sup 152}Eu activity as a result of repeated irradiation of solutions by a series of pulses decreases with each irradiation cycle. The obtained results are compared with data on the effect of maser radiation with a wavelength of 8 mm on the activity of the same isotope. Possible mechanisms of the effect of electromagnetic radiation on the {sup 152}Eu gamma activity are discussed. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Reconciliation of CDM abundance and {mu}{yields}e{gamma} in a radiative seesaw model

We reexamine relic abundance of a singlet fermion as a cold dark matter candidate, which contributes to the neutrino mass generation through radiative seesaw mechanism. We search solutions for Yukawa couplings and the mass spectrum of relevant fields to explain neutrino oscillation data. For such solutions, we show that an abundance of a lightest singlet fermion can be consistent with WMAP data without conflicting with both bounds of {mu}{yields}e{gamma} and {tau}{yields}{mu}{gamma}. This reconciliation does not need any modification of the original radiative seesaw model other than by specifying flavor structure of Yukawa couplings and taking account of coannihilation effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Sensors for Monitoring Gamma and Neutron Radiation

For safety and efficiency, nuclear reactors must be carefully monitored to provide feedback that enables the fission rate to be held at a constant target level via adjustments in the position of neutron-absorbing rods and moderating coolant flow rates. For automated reactor control, the monitoring system should provide calibrated analog or digital output. The sensors must survive and produce reliable output with minimal drift for at least one to two years, for replacement only during refueling. Small sensor size is preferred to enable more sensors to be placed in the core for more detailed characterization of the local fission rate and fuel consumption, since local deviations from the norm tend to amplify themselves. Currently, reactors are monitored by local power range meters (LPRMs) based on the neutron flux or gamma thermometers based on the gamma flux. LPRMs tend to be bulky, while gamma thermometers are subject to unwanted drift. Both electronic reactor sensors are plagued by electrical noise induced by ionizing radiation near the reactor core. A fiber optic sensor system was developed that is capable of tracking thermal neutron fluence and gamma flux in order to monitor nuclear reactor fission rates. The system provides near-real-time feedback from small- profile probes that are not sensitive to electromagnetic noise. The key novel feature is the practical design of fiber optic radiation sensors. The use of an actinoid element to monitor neutron flux in fiber optic EFPI (extrinsic Fabry-Perot interferometric) sensors is a new use of material. The materials and structure used in the sensor construction can be adjusted to result in a sensor that is sensitive to just thermal, gamma, or neutron stimulus, or any combination of the three. The tested design showed low sensitivity to thermal and gamma stimuli and high sensitivity to neutrons, with a fast response time.

Boyd, Clark D.↗