Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Field Operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Measurements of the Drift Current Oscillations in Thrusters with Closed Electron Drift

An induction method used to measure the drift current in thrusters with anode layer (TAL) has been applied for measuring the integral distortion of the magnetic field in the channel of a low-power stationary plasma thruster (SPT). Experiments are described in which the integral level of magnetic field oscillations in the narrow channel of a thruster with closed electron drift was determined. Experimental data show that when a discharge is ignited in an SPT, the drift current completely demagnetizes the discharge gap (the ratio between the self-magnetic and external fields reaches 90%). The same effect has been observed in TALs. In thrusters of both types, the total discharge current is one and a half order of magnitude higher than that typical of the stationary discharge and the plasma glow is observed not only inside but also outside the discharge channel. Drift current oscillations have been measured under steady-state conditions. It has been shown, in particular, that when the oscillations are intense (in weak magnetic fields on the order of 100 G), the drift-current-induced distortion of the magnetic field may reach 33%. Under rated operating conditions (200 G), the distortion does not exceed 8%. Beyond optimal operating conditions, the type of oscillation in SPTs and TALs and their performances differ. For example, in SPTs, a critical magnetic field at which the “turbulent” regime sets in is absent. In general, the discharge current is weakly dependent on the magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous monitoring of algal biomass: Success stories and lessons learned from long-term field deployment

Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.

Katinas, Christopher Michael [Sandia National Labo↗

Field Performance of Heat Pump Water Heaters in the Northeast

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($\$$182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(tm), A.O. Smith Voltex(r), and Stiebel Eltron Accelera(r)300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of Heat Pump Water Heaters in the Northeast

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HIGH FUSION PERFORMANCE IN SUPER H-MODE EXPERIMENTS ON ALCATOR C-MOD AND DIII-D

We report that the “Super H-Mode” regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest pedestal pressure ever achieved on a tokamak (p ped ~80kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated high performance, including the highest stored energy in the present configuration of DIII-D (W~2.2-3.2MJ), while utilizing only about half of the available heating power (P heat ~7-12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, Q DT,equiv ~0.5, ever achieved on a medium scale (R<2m) tokamak. Sustained high performance operation (β N ~2.9, H 98 ~1.6) has been achieved utilizing n=3 magnetic perturbations for density and impurity control. High pedestal and global performance has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. Lastly, Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its performance goals (Q=10) at I p < 15MA, and to enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High fusion performance in Super H-mode experiments on Alcator C-Mod and DIII-D

The ‘Super H-Mode’ regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest achieved on a tokamak (pped ~ 80 kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated strong performance, including the highest stored energy in the present configuration of DIII-D (W ~ 2.2–3.2 MJ), while utilizing only about half of the available heating power (Pheat ~ 7–12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, QDT,equiv ~ 0.5, achieved on a medium scale (R < 2 m) tokamak. Sustained high performance operation (βN ~ 2.9, H98 ~ 1.6) has been achieved utilizing n = 3 magnetic perturbations for density and impurity control. Pedestal and global confinement has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. A pair of simple performance metrics is developed to assess and compare regimes. Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its goals (Q = 10) at Ip < 15 MA, and to potentially enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

ENGINEERING,WIND ENERGY↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone: Preprint

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears — Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

gearbox↗

Results of ISO/TS 6336-22 Evaluating Full Contact Zone

ISO/TS 6336-22 (Calculation of load capacity of spur and helical gears - Part 22: Calculation of micropitting load capacity) is the ISO technical specification containing a proposal for calculations of the risk of micropitting in gear sets. Micropitting is a Hertzian fatigue phenomenon that appears as ultra-fine cracking and pitting on the flanks of gear teeth. Since progressive micropitting can lead to macropitting and flank damage, critical applications such as wind turbines, marine drives, and high-speed gear drives seek to accurately predict whether their designs are susceptible to this damage. ISO/TS 6336-22 assesses micropitting risk through a safety factor which is calculated as the minimum specific film thickness in the contact zone divided by a permissible specific film thickness. In the previous paper, the calculations were performed using the simplified method (Method B) that evaluates points on the path of contact. This was done for three gear sets that experienced micropitting in operation. The minimum specific film thickness for the two field cases was very high, which indicates that the gears were operating in the full elastohydrodynamic lubrication (EHL) regime. A more accurate calculation for these cases (Method A) calculates the specific film thickness across the entire contact zone. This paper applies this Method to the case study from the previous paper. The results are compared to micropitting observed in operation. Results are also compared to the results of the previous paper. Conclusions are made regarding the accuracy of both Methods compared to the field cases and relative to each other.

gearbox↗

Plasma performance and operational space with an RMP-ELM suppressed edge

Abstract The operational space and global performance of plasmas with edge-localized modes (ELMs) suppressed by resonant magnetic perturbations (RMPs) are surveyed by comparing AUG, DIII-D, EAST, and KSTAR stationary operating points. RMP-ELM suppression is achieved over a range of plasma currents, toroidal fields, and RMP toroidal mode numbers. Consistent operational windows in edge safety factor are found across devices, while windows in plasma shaping parameters are distinct. Accessed pedestal parameters reveal a quantitatively similar pedestal-top density limit for RMP-ELM suppression in all devices of just over 3 × 10 19 m −3 . This is surprising given the wide variance of many engineering parameters and edge collisionalities, and poses a challenge to extrapolation of the regime. Wide ranges in input power, confinement time, and stored energy are observed, with the achieved triple product found to scale like the product of current, field, and radius. Observed energy confinement scaling with engineering parameters for RMP-ELM suppressed plasmas are presented and compared with expectations from established H and L-mode scalings, including treatment of uncertainty analysis. Different scaling exponents for individual engineering parameters are found as compared to the established scalings. However, extrapolation to next-step tokamaks ITER and SPARC find overall consistency within uncertainties with the established scalings, finding no obvious performance penalty when extrapolating from the assembled multi-device RMP-ELM suppressed database. Overall this work identifies common physics for RMP-ELM suppression and highlights the need to pursue this no-ELM regime at higher magnetic field and different plasma physical size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field trials results of guided wave tomography

Corrosion is one of the industries major issues regarding the integrity of assets. Guided wave travel time tomography is a method capable of providing an absolute wall thickness map. This method is currently making the transition from the laboratory to the field. For this purpose a dedicated data acquisition system and special purpose EMAT sensor rings have been developed. The system can be deployed for permanent monitoring and inspections. Field trials have been conducted on various pipes with different diameters, containing either liquid or gas. The main focus has been on pipe supports. The results demonstrate the successful operation of the technology in the field. Expected corrosion damage was clearly visible on the produced results enabling asset owner to make calculated decisions on the pipelines safety, maintenance and operations.

42 ENGINEERING↗

Effects of electron beam parameters and velocity spread on radio frequency output of a photonic band gap cavity gyrotron oscillator

In this paper, the effects of electron beam parameters and velocity spread on the RF behavior of a metallic photonic band gap (PBG) cavity gyrotron operating at 35 GHz with TE{sub 041}–like mode have been theoretically demonstrated. PBG cavity is used here to achieve a single mode operation of the overmoded cavity. The nonlinear time-dependent multimode analysis has been used to observe the beam-wave interaction behavior of the PBG cavity gyrotron, and a commercially available PIC code “CST Particle Studio” has been reconfigured to obtain 3D simulation results in order to validate the analytical values. The output power for this typical PBG gyrotron has been obtained ∼108 kW with ∼15.5% efficiency in a well confined TE{sub 041}–like mode, while all other competing modes have significantly low values of power output. The output power and efficiency of a gyrotron depend highly on the electron beam parameters and velocity spread. The influence of several electron beam parameters, e.g., beam voltage, beam current, beam velocity pitch factor, and DC magnetic field, on the PBG gyrotron operations has been investigated. This study would be helpful in optimising the electron beam parameters and estimating accurate RF output power of the high frequency PBG cavity based gyrotron oscillators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Primary beam steering due to field leakage from superconducting SHMS magnets

In this study, simulations of the magnetic fields from the Super High Momentum Spectrometer in Hall C at Thomas Jefferson National Accelerator Facility show significant field leakage into the region of the primary beam line between the target and the beam dump. Without mitigation, these remnant fields will steer the unscattered beam enough to limit beam operations at small scattering angles. Presented here are magnetic field simulations of the spectrometer magnets and a solution using optimal placement of a minimal amount of shielding iron around the beam line.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Genomes to ecosystem function: Targeting critical knowledge gaps in methanogenesis and translation to updated global biogeochemical models

Natural freshwater temperate wetland systems currently represent the largest natural source of atmospheric methane, but are relatively understudied using systems biology tools (e.g. meta-omics) compared to other high producing methane systems (e.g. peat, tropical, or reconstructed wetlands). Using field investigations at the NOAA operated sentinel site on Lake Erie, methane producing activities and responses to geochemical conditions will be determined along seasonal and spatial gradients (Objective 1). Here, a combination of high-throughput activity and gas measurements, combined with high-resolution systems biology and analytical methods, will provide in depth knowledge of the microbiological, chemical, and physical constraints on methane production in wetlands. Using laboratory microcosms, the formation of anoxic microsites and their capacity to facilitate methane production in wetland soils will be simulated (Objective 2). This objective will validate the findings from the field investigations, offering a more controlled environment for teasing out the role of different yet interrelated variables. Lastly, these field and laboratory data will be used for multi-scale, process-level evaluation of an ecosystem biogeochemical model that accommodates these newly identified processes and parameterizes representation of these processes along relevant environmental gradients (Objective 3).This research will identify multiple interacting geochemical, ecological, and metabolic constraints that are poorly understood, oversimplified, or missing in global biogeochemical methane models. This proposal targets the role of oxygen limitation on methane processes in soil domains, to improve reactive transport models of microbial carbon cycling across terrestrial-aquatic soils and generate data on nutrient cycling activities in Great Lake wetlands. This information could provide new insights into the microbial controllers of Lake Erie eutrophication.

59 BASIC BIOLOGICAL SCIENCES↗

Anomalous laser deflection phenomenon based on the interaction of electro-optic and graded refractivity effects in Cu-doped KTa{sub 1−x}Nb{sub x}O{sub 3} crystal

An abnormal laser deflection phenomenon in a copper-doped KTa{sub 1−x}Nb{sub x}O{sub 3} (Cu:KTN) crystal is demonstrated in this Letter. A near-50 mrad beam deflection angle was observed when a voltage of 1.2 kV was applied to a Cu:KTN block with size of 2.8 mm × 1.2 mm × 7.5 mm at room temperature. The special features of this deflection phenomenon are that the laser beam deflection direction is perpendicular to the electric field direction, and the beam deflection angle remains unchanged when the electric field direction is reversed. The operating principle of the phenomenon is investigated and the origin of the deflection phenomenon is attributed to an interaction between the graded refractivity effect and the quadratic electro-optic effect of the crystal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗