Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

RhizoNet segments plant roots to assess biomass and growth for enabling self-driving labs

Abstract Flatbed scanners are commonly used for root analysis, but typical manual segmentation methods are time-consuming and prone to errors, especially in large-scale, multi-plant studies. Furthermore, the complex nature of root structures combined with noisy backgrounds in images complicates automated analysis. Addressing these challenges, this article introduces RhizoNet, a deep learning-based workflow to semantically segment plant root scans. Utilizing a sophisticated Residual U-Net architecture, RhizoNet enhances prediction accuracy and employs a convex hull operation for delineation of the primary root component. Its main objective is to accurately segment root biomass and monitor its growth over time. RhizoNet processes color scans of plants grown in a hydroponic system known as EcoFAB, subjected to specific nutritional treatments. The root detection model using RhizoNet demonstrates strong generalization in the validation tests of all experiments despite variable treatments. The main contributions are the standardization of root segmentation and phenotyping, systematic and accelerated analysis of thousands of images, significantly aiding in the precise assessment of root growth dynamics under varying plant conditions, and offering a path toward self-driving labs.

59 BASIC BIOLOGICAL SCIENCES↗

Lipid Informed Quantitation and Identification

LIQUID (Lipid Informed Quantitation and Identification) is a software program that has been developed to enable users to conduct both informed and high-throughput global liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based lipidomics analysis. This newly designed desktop application can quickly identify and quantify lipids from LC-MS/MS datasets while providing a friendly graphical user interface for users to fully explore the data. Informed data analysis simply involves the user specifying an electrospray ionization mode, lipid common name (i.e. PE(16:0/18:2)), and associated charge carrier. A stemplot of the isotopic profile and a line plot of the extracted ion chromatogram are also provided to show the MS-level evidence of the identified lipid. In addition to plots, other information such as intensity, mass measurement error, and elution time are also provided. Typically, a global analysis for 15,000 lipid targets.

Crowell, Kevin↗

PHOTOMETRIC REDSHIFT PROBABILITY DISTRIBUTIONS FOR GALAXIES IN THE SDSS DR8

We present redshift probability distributions for galaxies in the Sloan Digital Sky Survey (SDSS) Data Release 8 imaging data. We used the nearest-neighbor weighting algorithm to derive the ensemble redshift distribution N(z), and individual redshift probability distributions P(z) for galaxies with r < 21.8 and u < 29.0. As part of this technique, we calculated weights for a set of training galaxies with known redshifts such that their density distribution in five-dimensional color-magnitude space was proportional to that of the photometry-only sample, producing a nearly fair sample in that space. We estimated the ensemble N(z) of the photometric sample by constructing a weighted histogram of the training-set redshifts. We derived P(z)'s for individual objects by using training-set objects from the local color-magnitude space around each photometric object. Using the P(z) for each galaxy can reduce the statistical error in measurements that depend on the redshifts of individual galaxies. The spectroscopic training sample is substantially larger than that used for the DR7 release. The newly added PRIMUS catalog is now the most important training set used in this analysis by a wide margin. We expect the primary sources of error in the N(z) reconstruction to be sample variance and spectroscopic failures: The training sets are drawn from relatively small volumes of space, and some samples have large incompleteness. Using simulations we estimated the uncertainty in N(z) due to sample variance at a given redshift to be {approx}10%-15%. The uncertainty on calculations incorporating N(z) or P(z) depends on how they are used; we discuss the case of weak lensing measurements. The P(z) catalog is publicly available from the SDSS Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

Consistent Feature Extraction From Vector Fields: Combinatorial Representations and Analysis Under Local Reference Frames

This dissertation presents research on addressing some of the contemporary challenges in the analysis of vector fields—an important type of scientific data useful for representing a multitude of physical phenomena, such as wind flow and ocean currents. In particular, new theories and computational frameworks to enable consistent feature extraction from vector fields are presented. One of the most fundamental challenges in the analysis of vector fields is that their features are defined with respect to reference frames. Unfortunately, there is no single “correct” reference frame for analysis, and an unsuitable frame may cause features of interest to remain undetected, thus creating serious physical consequences. This work develops new reference frames that enable extraction of localized features that other techniques and frames fail to detect. As a result, these reference frames objectify the notion of “correctness” of features for certain goals by revealing the phenomena of importance from the underlying data. An important consequence of using these local frames is that the analysis of unsteady (time-varying) vector fields can be reduced to the analysis of sequences of steady (timeindependent) vector fields, which can be performed using simpler and scalable techniques that allow better data management by accessing the data on a per-time-step basis. Nevertheless, the state-of-the-art analysis of steady vector fields is not robust, as most techniques are numerical in nature. The residing numerical errors can violate consistency with the underlying theory by breaching important fundamental laws, which may lead to serious physical consequences. This dissertation considers consistency as the most fundamental characteristic of computational analysis that must always be preserved, and presents a new discrete theory that uses combinatorial representations and algorithms to provide consistency guarantees during vector field analysis along with the uncertainty visualization of unavoidable discretization errors. Together, the two main contributions of this dissertation address two important concerns regarding feature extraction from scientific data: correctness and precision. The work presented here also opens new avenues for further research by exploring more-general reference frames and more-sophisticated domain discretizations.

97 MATHEMATICS AND COMPUTING↗

Impact of numerical choices on water conservation in the E3SM Atmosphere Model version 1 (EAMv1)

Abstract. The conservation of total water is an important numerical feature for global Earth system models. Even small conservation problems in the water budget can lead to systematic errors in century-long simulations. This study quantifies and reduces various sources of water conservation error in the atmosphere component of the Energy Exascale Earth System Model. Several sources of water conservation error have been identified during the development of the version 1 (V1) model. The largest errors result from the numerical coupling between the resolved dynamics and the parameterized sub-grid physics. A hybrid coupling using different methods for fluid dynamics and tracer transport provides a reduction of water conservation error by a factor of 50 at 1∘ horizontal resolution as well as consistent improvements at other resolutions. The second largest error source is the use of an overly simplified relationship between the surface moisture flux and latent heat flux at the interface between the host model and the turbulence parameterization. This error can be prevented by applying the same (correct) relationship throughout the entire model. Two additional types of conservation error that result from correcting the surface moisture flux and clipping negative water concentrations can be avoided by using mass-conserving fixers. With all four error sources addressed, the water conservation error in the V1 model becomes negligible and insensitive to the horizontal resolution. The associated changes in the long-term statistics of the main atmospheric features are small. A sensitivity analysis is carried out to show that the magnitudes of the conservation errors in early V1 versions decrease strongly with temporal resolution but increase with horizontal resolution. The increased vertical resolution in V1 results in a very thin model layer at the Earth's surface, which amplifies the conservation error associated with the surface moisture flux correction. We note that for some of the identified error sources, the proposed fixers are remedies rather than solutions to the problems at their roots. Future improvements in time integration would be beneficial for V1.

54 ENVIRONMENTAL SCIENCES↗

Impact of numerical choices on water conservation in the E3SM Atmosphere Model Version 1 (EAM V1)

The conservation of total water is an important numerical feature for global Earth system models. Even small conservation problems in the water budget can lead to systematic errors in century-long simulations for sea level rise projection. This study quantifies and reduces various sources of water conservation error in the atmosphere component of the Energy Exascale Earth System Model. Several sources of water conservation error have been identified during the development of the version 1 (V1) model. The largest errors result from the numerical coupling between the resolved dynamics and the parameterized sub-grid physics. A hybrid coupling using different methods for fluid dynamics and tracer transport provides a reduction of water conservation error by a factor of 50 at 1&deg; horizontal resolution as well as consistent improvements at other resolutions. The second largest error source is the use of an overly simplified relationship between the surface moisture flux and latent heat flux at the interface between the host model and the turbulence parameterization. This error can be prevented by applying the same (correct) relationship throughout the entire model. Two additional types of conservation error that result from correcting the surface moisture flux and clipping negative water concentrations can be avoided by using mass-conserving fixers. With all four error sources addressed, the water conservation error in the V1 model is negligible and insensitive to the horizontal resolution. The associated changes in the long-term statistics of the main atmospheric features are small. A sensitivity analysis is carried out to show that the magnitudes of the conservation errors decrease strongly with temporal resolution but increase with horizontal resolution. The increased vertical resolution in the new model results in a very thin model layer at the Earth’s surface, which amplifies the conservation error associated with the surface moisture flux correction. We note that for some of the identified error sources, the proposed fixers are remedies rather than solutions to the problems at their roots. Future improvements in time integration would be beneficial for this model.

Zhang, Kai↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

Demonstration of Dimensional and Microstructural Postirradiation Examination Capabilities on MiniFuel Disk Specimens

This work demonstrates two new MiniFuel postirradiation examination (PIE) capabilities, laser profilometry and serial sectioning, for future use on alpha-U specimens for the upcoming Mini-99 irradiation campaign. Representative U–Mo disk specimens—3 mm in diameter and approximately 0.75 mm in thickness—were subjected to dimensional measurements using standard calipers, as well as a new Keyence CL-3000 series laser profilometry system designed to measure the surface of both sides of the disk simultaneously. The laser profilometry system captured thickness gradients across the specimens as large as 0.2 mm. Additionally, because of the limitations inherent to the use of calipers, caliper measurements consistently overestimated the initial volume of MiniFuel disk specimens compared to the laser profilometry method by up to 5%. However, the results show that optimal data collection and analysis procedures are crucial to avoiding significant artifacts during data collection that can lead to large errors (approximately 10%). Serial sectioning using a combination of ion milling and electron imaging was also demonstrated for the analysis of micron-sized control volumes. Nanometer- to micron-scale porosity was resolved on a representative U–Mo specimen before irradiation, even when the surface of the specimen appeared free of porosity. Future efforts to relate microstructural features (porosity, fission product distributions, and so on) to macroscale effects (dimensional changes, thermal conductivity degradation) require accurate characterization methods such as those demonstrated in this work. These advanced PIE capabilities will be applied to optimized alpha-U specimens for the upcoming Mini-99 neutron irradiation campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Merger identification through photometric bands, colours, and their errors

Aims. We present the application of a fully connected neural network (NN) for galaxy merger identification using exclusively photometric information. Our purpose is not only to test the method’s efficiency, but also to understand what merger properties the NN can learn and what their physical interpretation is. Methods. We created a class-balanced training dataset of 5860 galaxies split into mergers and non-mergers. The galaxy observations came from SDSS DR6 and were visually identified in Galaxy Zoo. The 2930 mergers were selected from known SDSS mergers and the respective non-mergers were the closest match in both redshift and r magnitude. The NN architecture was built by testing a different number of layers with different sizes and variations of the dropout rate. We compared input spaces constructed using: the five SDSS filters: u, g, r, i, and z; combinations of bands, colours, and their errors; six magnitude types; and variations of input normalization. Results. We find that the fibre magnitude errors contribute the most to the training accuracy. Studying the parameters from which they are calculated, we show that the input space built from the sky error background in the five SDSS bands alone leads to 92.64 ± 0.15% training accuracy. We also find that the input normalization, that is to say, how the data are presented to the NN, has a significant effect on the training performance. Conclusions. We conclude that, from all the SDSS photometric information, the sky error background is the most sensitive to merging processes. This finding is supported by an analysis of its five-band feature space by means of data visualization. Moreover, studying the plane of the g and r sky error bands shows that a decision boundary line is enough to achieve an accuracy of 91.59%.

79 ASTRONOMY AND ASTROPHYSICS↗

Planning, design and logistics of a decision analysis study: The FBI/Ames study involving forensic firearms examiners

This paper describes design and logistical aspects of a decision analysis study to assess the performance of qualified firearms examiners working in accredited laboratories in the United States in terms of accuracy (error rate), repeatability, and reproducibility of decisions involving comparisons of fired bullets and cartridge cases. The purpose of the study was to validate current practice of the forensic discipline of firearms/toolmarks (F/T) examination. It elicited error rate data by counting the number of false positive and false negative conclusions. Preceded by the experimental design, decisions, and logistics described herein, testing was ultimately administered 173 qualified, practicing F/T examiners in public and private crime laboratories. The first round of testing evaluated accuracy, while two subsequent rounds evaluated repeatability and reproducibility of examiner conclusions. This project expands on previous studies by involving many F/T examiners in challenging comparisons and by executing the study in the recommended double-blind format.

99 GENERAL AND MISCELLANEOUS↗

Dark Energy Survey Year 1 Results: Multi-Probe Methodology and Simulated Likelihood Analyses

We present the methodology for and detail the implementation of the Dark Energy Survey (DES) 3x2pt DES Year 1 (Y1) analysis, which combines configuration-space two-point statistics from three different cosmological probes: cosmic shear, galaxy-galaxy lensing, and galaxy clustering, using data from the first year of DES observations. We have developed two independent modeling pipelines and describe the code validation process. We derive expressions for analytical real-space multi-probe covariances, and describe their validation with numerical simulations. We stress-test the inference pipelines in simulated likelihood analyses that vary 6-7 cosmology parameters plus 20 nuisance parameters and precisely resemble the analysis to be presented in the DES 3x2pt analysis paper, using a variety of simulated input data vectors with varying assumptions. We find that any disagreement between pipelines leads to changes in assigned likelihood $\Delta \chi^2 \le 0.045$ with respect to the statistical error of the DES Y1 data vector. We also find that angular binning and survey mask do not impact our analytic covariance at a significant level. We determine lower bounds on scales used for analysis of galaxy clustering (8 Mpc$~h^{-1}$) and galaxy-galaxy lensing (12 Mpc$~h^{-1}$) such that the impact of modeling uncertainties in the non-linear regime is well below statistical errors, and show that our analysis choices are robust against a variety of systematics. These tests demonstrate that we have a robust analysis pipeline that yields unbiased cosmological parameter inferences for the flagship 3x2pt DES Y1 analysis. We emphasize that the level of independent code development and subsequent code comparison as demonstrated in this paper is necessary to produce credible constraints from increasingly complex multi-probe analyses of current data.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiation Therapy of Liver Cancer

Purpose: To evaluate the dosimetric impact of rotational setup errors in stereotactic body radiotherapy (SBRT) treatment of liver tumors and to investigate whether translational shifts can compensate for rotation. Methods and Materials: The positioning accuracy in 20 patients with liver malignancies treated with SBRT was reevaluated offline by matching the patients' cone-beam computed tomography (CT) scans (n=75) to the planning CT scans and adjusting the 3 rotational angles (pitch, roll, and yaw). Systematic and random setup errors were calculated. The dosimetric changes caused by rotational setup errors were quantified for both simulated and observed patient rotations. Dose distributions recalculated on the rotated CT scans were compared with the original planned doses. Translational corrections were simulated based on manual translational registration of the rotated images to the original CT scans. The correction efficacy was evaluated by comparing the recalculated plans with the original plans. Results: The systematic rotational setup errors were -0.06 Degree-Sign {+-} 0.68 Degree-Sign , -0.29 Degree-Sign {+-} 0.62 Degree-Sign , and -0.24 Degree-Sign {+-} 0.61 Degree-Sign ; the random setup errors were 0.80 Degree-Sign , 1.05 Degree-Sign , and 0.61 Degree-Sign for pitch, roll, and yaw, respectively. Analysis of CBCT images showed that 56.0%, 14.7%, and 1.3% of treated fractions had rotational errors of >1 Degree-Sign , >2 Degree-Sign , and >3 Degree-Sign , respectively, in any one of the rotational axes. Rotational simulations demonstrated that the reduction of gross tumor volume (GTV) coverage was <2% when rotation was <3 Degree-Sign . Recalculated plans using actual patient roll motions showed similar reduction (<2%) in GTV coverage. Translational corrections improved the GTV coverage to within 3% of the original values. For organs at risk (OAR), the dosimetric impact varied case by case. Conclusion: Actual rotational setup errors in SBRT for liver tumors are relatively small in magnitude and are unlikely to affect GTV coverage significantly. Translational corrections can be optimized to compensate for rotational setup errors. However, caution regarding possible dose increases to OAR needs to be exercised.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cloud Influence on ERA5 and AMPS Surface Downwelling Longwave Radiation Biases in West Antarctica

The surface downwelling longwave radiation component (LW?) is crucial for the determination of the surface energy budget and has significant implications for the resilience of ice surfaces in the polar regions. Accurate model evaluation of this radiation component requires knowledge about the phase, vertical distribution, and associated temperature of water in the atmosphere, all of which control the LW? signal measured at the surface. In this study, we examine the LW? model errors found in the Antarctic Mesoscale Prediction System (AMPS) operational forecast model and the ERA5 reanalysis model relative to observations from the AWARE campaign at McMurdo Station and the West Antarctic Ice Sheet (WAIS) Divide. The errors are calculated separately for observed clear sky conditions, ice cloud occurrences, and liquid-bearing cloud layer (LBCL) occurrences. The analysis results show a tendency (in both models at each site) to underestimate the LW? during clear sky conditions, high error variability (standard deviations > 20 W/m2) during any type of cloud occurrence, and negative LW? biases when LBCLs are observed (bias magnitudes > 15 W/m2 in tenuous LBCL cases; > 43 W/m2 in optically thick/opaque LBCLs instances). We suggest that a generally dry and liquid water-deficient atmosphere responsible for the identified LW? biases in both models is the result of excessive ice formation and growth, which could stem from model initial and lateral boundary conditions, microphysics scheme, aerosol representation, and/or limited vertical resolution.

Silber, Israel↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Asymptotic analysis of the fluid flow with a pressure-dependent viscosity in a system of thin pipes

We consider the incompressible fluid with a pressure-dependent viscosity flowing through a multiple pipe system. The viscosity–pressure relation is given by the Barus law commonly used in the engineering applications. Assuming that the ratio between pipes thickness and its length is small, we propose a rigorous asymptotic approach based on the concept of the transformed pressure. As a result, we obtain new macroscopic model describing the effective behavior of the fluid in the system. In particular, the generalized version of the Kirchhoff’s law is derived giving the explicit formula for the junction pressure. The error estimate for the asymptotic approximation is also provided. Mathematical analysis presented here can be applied to a general viscosity–pressure relation satisfied by other empiric laws.

97 MATHEMATICS AND COMPUTING↗

Optimized mirror shape tuning using beam weightings based on distance, angle of incidence, reflectivity, and power

For glancing-incidence optical systems, such as short-wavelength optics used for nano-focusing, incorporating physical factors in the calculations used for shape optimization can improve performance. Wavefront metrology, including the measurement of a mirror's shape or slope, is routinely used as input for mirror figure optimization on mirrors that can be bent, actuated, positioned, or aligned. Modeling shows that when the incident power distribution, distance from focus, angle of incidence, and the spatially varying reflectivity are included in the optimization, higher Strehl ratios can be achieved. Following the works of Maréchal and Mahajan, optimization of the Strehl ratio (for peak intensity with a coherently illuminated system) occurs when the expectation value of the phase error's variance is minimized. We describe an optimization procedure based on regression analysis that incorporates these physical parameters. This approach is suitable for coherently illuminated systems of nearly diffraction-limited quality. Mathematically, this work is an enhancement of the methods commonly applied for ex situ alignment based on uniform weighting of all points on the surface (or a sub-region of the surface). It follows a similar approach to the optimization of apodized and non-uniformly illuminated optical systems. Significantly, it reaches a different conclusion than a more recent approach based on minimization of focal plane ray errors.

47 OTHER INSTRUMENTATION↗