Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Improvements in Electron-Photon-Relaxation Data for MCNP6

The Los Alamos Monte Carlo transport code MCNP6 has recently benefitted from significant work to improve the photon-electron transport and atomic-relaxation capabilities of the code. The improvements include extension of existing photon data to lower energies than previously supported; addition of new data such as subshell-specific photoelectric cross sections; completion of the incoherent and coherent form factor data to cover all scattering angles at all supported energies; new data for electron interactions including Bremsstrahlung, elastic scattering, subshell-specific electroionization, and atomic excitation; a much more detailed representation for atomic relaxation; and an entirely new (to MCNP) approach to electron transport: the single-event method. These improvements were made available with the initial production release of MCNP6 along with an extended electron, photon, and relaxation data file eprdata12 to support the new capabilities. More recently new data have become available and have now been incorporated into MCNP6, correcting a few issues with the previous work, and adding new sets of cross sections that were not included in eprdata12. The purpose of this paper is to introduce these newer changes and enhancements, which will be included with the next public release of the MCNP6 code system. The database that supports these developments relies on an evolving set of libraries originally released by D. E. Cullen and collaborators as separate data for photo-atomic interactions (EPDL), atomic relaxation (EADL), and electro-atomic interactions (EEDL). An updated version of this release was officially adopted in the ENDF/B VI.8 release of the Evaluated Nuclear Data File and it was this source that was used to produce the ACE (A Compact ENDF) format library eprdata12 for use in the initial production release of MCNP6.1 (and the subsequent interim release MCNP6.1.1). The latest improved version of this database was released by Cullen in 2014. This is the EPICS2014 collection, which includes both an ENDF-formatted file and separate EPDL, EADL, and EEDL files. In the area of photon-electron transport and atomic-relaxation, the newest enhancements to the current version of MCNP6 (scheduled for release as MCNP6.2) are primarily based on improvements and additions drawn from the EPICS2014 data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep SOAR follow-up photometry of two Milky Way outer-halo companions discovered with Dark Energy Survey

We report the discovery of a new star cluster, DES 3, in the constellation of Indus, and deeper observations of the previously identified satellite DES J0222.7−5217 (Eridanus III). DES 3 was detected as a stellar overdensity in first-year Dark Energy Survey data, and confirmed with deeper photometry from the 4.1-m Southern Astrophysical Research (SOAR) telescope. The new system was detected with a relatively high significance and appears in the DES images as a compact concentration of faint blue point sources. We determine that DES 3 is located at a heliocentric distance of ≃76.2 kpc and it is dominated by an old (≃9.8 Gyr) and metal-poor ([Fe/H] ≃ −1.84) population. While the age and metallicity values of DES 3 are comparable to typical globular clusters (objects with a high stellar density, stellar mass of ∼10^5 M_⊙ and luminosity ∼ −7.3), its half-light radius (r_h ∼ 6.87 pc) and luminosity (M_V ∼ −1.7) are more indicative of faint star cluster. Based on the angular size, DES 3, with a value of r_h ∼ 0$${^{\prime}_{.}}$$31, is among the smallest faint star clusters known to date. Furthermore, using deeper imaging of DES J0222.7−5217 taken with the SOAR telescope, we update structural parameters and perform the first isochrone modelling. Our analysis yields the first age (≃12.6 Gyr) and metallicity ([Fe/H] ≃ −2.01) estimates for this object. The half-light radius (r_h ≃ 11.24 pc) and luminosity (M_V ≃ −2.4) of DES J0222.7−5217 suggest that it is likely a faint star cluster. The discovery of DES 3 indicates that the census of stellar systems in the Milky Way is still far from complete, and demonstrates the power of modern wide-field imaging surveys to improve our knowledge of the Galaxy’s satellite population.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

An actuarial approach to retrofit savings in buildings

An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution of the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.

Subbarao, Krishnappa↗

New work on updating and extending the nuclear data standards

An International Atomic Energy Agency (IAEA) Data Development Project was initiated to provide a mechanism for allowing new experimental data and improvements in evaluation procedures to be incorporated into new evaluations of the standards. The work on this project is ongoing. In the past very long periods sometimes occurred between evaluations of the standards. Through the use of this Project, such long periods should not occur. Work on the cross section standards through this Project has included an update of the experimental data to be used in the cross section standards evaluations, a study of the uncertainties obtained in the international standards evaluation, and improvements in the smoothing procedure for capture cross sections. It was decided that this Project should have a broader range of activities than just the cross section standards and thus encompass standards related activities. The following are being investigated: improvements in the gold cross section at energies below where it is considered a standard and work on certain cross sections that are not as well known as the cross section standards but could be very useful as reference cross sections relative to which certain types of cross section measurements can be made. This work includes prompt gamma-ray production in fast neutron-induced reactions, and work on the {sup 252}Cf spontaneous fission neutron spectrum and the {sup 235}U thermal neutron fission spectrum. Most of the data investigated through this Project are used in dosimetry applications. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implications of AI and Data Center Service Demand on Energy, Water, and Economic Systems

This talk focuses on the challenges posed by the rapid growth of data centers (DCs), which rely heavily on electricity, water, land, and mineral resources, and have significant interactions with economic growth. The U.S. leads in DC deployment, but understanding how resource demands and constraints impact DC expansion requires strategic multisector analysis. To address this, the talk introduces a new conceptual framework and modeling capability within GCAM-USA, allowing integrated analysis of DC service demand, electricity, and direct and indirect water needs under varied scenarios. Insights include state-level water and electricity trends for DCs, uncertainty bounds, and the broader implications for resources and economics.

Data Centers↗

Genetic algorithm optimization of nuclear criticality experiment for reduction of intermediate-energy 239 Pu nuclear data uncertainties

Nuclear criticality experiments are conducted to investigate specific nuclear data important for safe handling and storage of fissile materials, reactor design and operation, and the validation of radiation transport codes. Incorrect or uncertain nuclear data can prohibitively impact operational safety limits, reactor licensing, and predictive simulation capability; therefore, integral measurements from criticality experiments are necessary and should be performed frequently. To maximize the impact of the integral measurements, it is important to consider experiment geometry, material selection, and component dimensions. When taking these considerations into account, the experiment design process becomes iterative and very time intensive. This work utilizes a genetic algorithm to efficiently explore potential nuclear criticality experiment designs for the Laboratory Directed Research & Development project PARADIGM (PARallel Approach of Differential and InteGral Measurements) at Los Alamos National Laboratory. In this paper, the building blocks of the genetic algorithm are discussed in detail, the genetic algorithm methodology is verified, and the genetic algorithm is used to produce three candidate experiment models for the final PARADIGM design. The three candidate models produced by the genetic algorithm consist of copper-reflected assemblies containing 14 repeating units of alumina, graphite, boron, and plutonium plates. Furthermore, in addition to the optimization results, final design considerations are also discussed for designs with a height and/or weight very close to or slightly above assembly machine operational limits.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Graybox and adaptative dynamic neural network identification models to infer the steady state efficiency of solar thermal collectors starting from the transient condition

This paper deals with the development of methods for non steady state test of solar thermal collectors. Our goal is to infer performances in steady-state conditions in terms of the efficiency curve when measures in transient conditions are the only ones available. We take into consideration the method of identification of a system in dynamic conditions by applying a Graybox Identification Model and a Dynamic Adaptative Linear Neural Network (ALNN) model. The study targets the solar collector with evacuated pipes, such as Dewar pipes. The mathematical description that supervises the functioning of the solar collector in transient conditions is developed using the equation of the energy balance, with the aim of determining the order and architecture of the two models. The input and output vectors of the two models are constructed, considering the measures of 4 days of solar radiation, flow mass, environment and heat-transfer fluid temperature in the inlet and outlet from the thermal solar collector. The efficiency curves derived from the two models are detected in correspondence to the test and validation points. The two synthetic simulated efficiency curves are compared with the actual efficiency curve certified by the Swiss Institute Solartechnik Puffung Forschung which tested the solar collector performance in steady-state conditions according to the UNI-EN 12975 standard. An acquisition set of measurements of only 4 days in the transient condition was enough to trace through a Graybox State Space Model the efficiency curve of the tested solar thermal collector, with a relative error of synthetic values with respect to efficiency certified by SPF, lower than 0.5%, while with the ALNN model the error is lower than 2.2% with respect to certified one. (author)

14 SOLAR ENERGY↗

Tests of Exchange-Correlation Functional Approximations Against Reliable Experimental Data for Average Bond Energies of 3d Transition Metal Compounds

One of the greatest challenges for the theoretical study of transition-metal-containing compounds is the treatment of intrinsically multi-configurational atoms and molecules, which require a multireference (MR) treatment in wave function theory. The accuracy of density functional theory for this kind of system is still being explored. Here, we continue that exploration by presenting the predictions of 42 exchange-correlation (xc) functionals of 11 types [local spin density approximation (LSDA), generalized gradient approximation (GGA), nonseparable gradient approximation (NGA), global-hybrid GGA, meta-GGA, meta-NGA, global-hybrid meta-GGA, range-separated hybrid GGA, range-separated hybrid meta-GGA, range-separated hybrid meta-NGA, and DFT augmented with molecular mechanics damped dispersion (DFT-D)]. DFT-D is tested both for Grimme’s DFT-D3(BJ) model with Becke-Johnson damping and for ωB97X-D, which has the empirical atom-atom dispersion parametrized by Chai and Head-Gordon. The Hartree-Fock (HF) method has also been included because it can be viewed as a functional with 100% HF exchange and no correlation. These methods are tested against a database including 70 first-transition-row (3d) transition metal-containing molecules (19 single-reference molecules and 51 MR molecules), all of which have estimated experimental uncertainties equal to or less than 2.0 kcal/mol in the heat of formation. We analyze the accuracy in terms of the atomization energy per bond instead of the enthalpy of formation of the molecule because it allows us to test electronic energies without the possibility of cancellation of errors in electronic energies with errors in vibrational energies. All the density functional and HF wave functions have been optimized to a stable solution, in which the spatial symmetry is allowed to be broken to minimize the energy to a stable solution. We find that Ï„-HCTHhyb has the smallest mean unsigned error (MUE) in average bond energy, in particular 2.5 kcal/mol, for the full set of 70 molecules, and it also gives the smallest MUE for MR systems. For single-reference systems, MPW1B95 has the best performance, with an MUE of 1.6 kcal/mol. Among local functionals, which are the least expensive, the best performance (MUE = 3.9 kcal/mol) for the total database is achieved by OreLYP, OLYP, M06-L, and τ-HCTH. It is observed that adding HF exchange does not guarantee better accuracy for GGAs or for the NGA, but inclusion of the kinetic energy densities can benefit the GGAs and NGA calculations. The metal hydrides and metal oxides are demonstrated to be most difficult bond types to predict, and CrO 3 , FeH, CrO, VH and MnS are found to be the most difficult molecules to predict. The middle transition metals (V, Cr, and Mn) lead to larger errors on average than either the early or late transition metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-accuracy emulators for observables in ΛCDM, N eff, Σ m ν, and w cosmologies

ABSTRACT We use the emulation framework CosmoPower to construct and publicly release neural network emulators of cosmological observables, including the cosmic microwave background (CMB) temperature and polarization power spectra, matter power spectrum, distance-redshift relation, baryon acoustic oscillation (BAO) and redshift-space distortion (RSD) observables, and derived parameters. We train our emulators on Einstein–Boltzmann calculations obtained with high-precision numerical convergence settings, for a wide range of cosmological models including ΛCDM, wCDM, ΛCDM + Neff, and ΛCDM + Σmν. Our CMB emulators are accurate to better than 0.5 per cent out to ℓ = 104, which is sufficient for Stage-IV data analysis, and our P(k) emulators reach the same accuracy level out to $k=50 \, \, \mathrm{Mpc}^{-1}$, which is sufficient for Stage-III data analysis. We release the emulators via an online repository (CosmoPower Organisation), which will be continually updated with additional extended cosmological models. Our emulators accelerate cosmological data analysis by orders of magnitude, enabling cosmological parameter extraction analyses, using current survey data, to be performed on a laptop. We validate our emulators by comparing them to class and camb and by reproducing cosmological parameter constraints derived from Planck TT, TE, EE, and CMB lensing data, as well as from the Atacama Cosmology Telescope Data Release 4 CMB data, Dark Energy Survey Year-1 galaxy lensing and clustering data, and Baryon Oscillation Spectroscopic Survey Data Release 12 BAO and RSD data.

Astronomy & Astrophysics↗