Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Coherent dual-comb spectroscopy at high signal-to-noise ratio

Two coherent frequency combs are used to measure the full complex response of a sample in a configuration analogous to a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual-comb spectrometer retains the frequency accuracy and resolution of the reference underlying the stabilized combs. We discuss the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) over the 9 THz bandwidth is 2500 for both the magnitude and phase of the measured spectral response and the peak SNR is 4000. This peak SNR corresponds to a fractional absorption sensitivity of 0.05% and a phase sensitivity of 250 microradians. As the spectral coverage of combs expands, coherent dual-comb spectroscopy could provide high-frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions. Work of U. S. government, not subject to copyright.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

36 MATERIALS SCIENCE↗

Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

36 MATERIALS SCIENCE↗

Study of GSO scintillator for the LHCf upgrade

The GSO scintillator has a very excellent radiation resistance, fast decay time and large amounts of light yield. Because of these features, GSO will be used to upgrade the current LHCf detector. We examined the features of GSO by using heavy ion beam at Heavy Ion Medical Accelerator in Chiba (HIMAC) Japan. The linearity of PMT R7400 for the large light yield of GSO with a {sup 132}Xe beam and the radiation hardness with a {sup 12}C beam were measured. As a result, GSO scintillator showed a good linearity up to the signal corresponding to 6 TeV EM-shower maximum in the LHCf detector, and a good radiation hardness up to 7x10{sup 5} Gy. For the LHCf Arm1 detector, small scaled GSO crystals (GSO bars), have been fabricated for the position determination detector. 5 GSO bars have been manufactured and its performance have been evaluated using {sup 12}C beam. Its light yield and position dependency have been evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent N* results from photoproduction experiments at CLAS

The recent breakthroughs in the technology of polarised targets have enabled a new generation of meson photo-production experiments to be carried out. A measurement of a full set of polarisation observables off both polarised proton and neutron targets and in a large number of meson-production channels has come within sight. Such a measurement would very significantly reduce model-dependence in the analysis of the data and thus has the potential to resolve long-standing issues, such as the 'missing resonance' problem, and shed new light on the nucleon excitation spectrum. This has formed the motivation for the recent N* experimental programme of CLAS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution measurements of Cl 15 + line shifts in hot, solid-density plasmas

The shifts of the 1s3p 1 P 1 → 1s 2 1 S 0 He-β transition of Cl 15+ were measured in hot (≥ 600 eV), dense (1–2 g/cm 3 ) plasmas generated by a (66–151)-J short-pulse laser beam at the Orion laser facility. The subpicosecond laser beam irradiated optically thin, KCl microdot targets buried in layers of plastic. The measured red shifts ranged from 4.8 ± 1.1 eV for unshocked to 5.9 ± 1.2 eV for shocked targets. Furthermore, these values are significantly smaller than recent predictions from a self-consistent-field ion-sphere model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Property Variations in Modern REBCO Coated Conductors from Multiple Manufacturers

The complex, multilayer structure of REBCO Coated Conductor (CC) poses significant challenges in the fabrication of high magnetic field devices where large stresses may initiate various forms of damage. Our goal is to peer below the cartoon representations of CC so that, amongst other things, we might better understand whether a CC from one manufacturer is interchangeable with that from another. This involves knowledge of a broad range of electromagnetic, geometric, microstructural, and J c (θ,B,T) properties, and their variations that collectively pose challenges for the fault tolerance of REBCO CC devices. Accordingly, comparative measurements of J c , visualization of flux penetration with Magneto-Optical Imaging (MOI), tape geometry from Scanning Electron Microscopy (SEM) of polished cross-sections, and extensive optical microscopy was performed on recently purchased samples from multiple manufacturers. Our analyses reveal many deviations from or characteristics absent from manufacturers’ specifications, while a comparison of different manufacturers’ mechanically and laser slit tapes shows a diverse array of slitting characteristics amongst the manufacturers and variation in properties those made to the same specification. Laser slit tapes from several manufacturers reveal ablated edges with damaged regions extending up to 50 μm, comparable to the damaged region found in the mechanically slit CC of this study. Overall, the aim of this study is to flesh out appropriate ways to understand the real conductor below the manufacturers’ cartoons to avoid surprises in our REBCO CC coil development program. The goal of this work was to perform a broad array of characterizations of the type needed for validation of purpose for making high field magnets: to our surprise we found a wide range of properties which greatly impact the mechanical strength and electromagnetic performance of solenoids composed of these conductors and reinforced the need for a broad characterization program for each conductor prior to its implementation.

Bradford, G.↗

Electromagnetic response of C 12 : A first-principles calculation

Here, the longitudinal and transverse electromagnetic response functions of $^{12}$C are computed in a ``first-principles'' Green's function Monte Carlo calculation, based on realistic two- and three-nucleon interactions and associated one- and two-body currents. We find excellent agreement between theory and experiment and, in particular, no evidence for the quenching of measured versus calculated longitudinal response. This is further corroborated by a re-analysis of the Coulomb sum rule, in which the contributions from the low-lying $J^\pi\,$=$\, 2^+$, $0^+$ (Hoyle), and $4^+$ states in $^{12}$C are accounted for explicitly in evaluating the total inelastic strength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE GALACTIC CENTER IN THE FAR-INFRARED

We analyze the far-infrared dust emission from the Galactic center region, including the circumnuclear disk (CND) and other structures, using Herschel PACS and SPIRE photometric observations. These Herschel data are complemented by unpublished observations by the Infrared Space Observatory Long Wavelength Spectrometer (ISO-LWS), which used parallel mode scans to obtain photometric images of the region with a larger beam than Herschel but with a complementary wavelength coverage and more frequent sampling with 10 detectors observing at 10 different wavelengths in the range from 46 {mu}m to 180 {mu}m, where the emission peaks. We also include data from the Midcourse Space Experiment at 21.3 {mu}m for completeness. We model the combined ISO-LWS continuum plus Herschel PACS and SPIRE photometric data toward the central 2 pc in Sagittarius A* (Sgr A*), a region that includes the CND. We find that the far-infrared spectral energy distribution is best represented by a continuum that is the sum of three gray body curves from dust at temperatures of 90, 44.5, and 23 K. We obtain temperature and molecular hydrogen column density maps of the region. We estimate the mass of the inner part of the CND to be {approx}5.0 x 10{sup 4} M{sub sun}, with luminosities: L{sub cavity} {approx} 2.2 x 10{sup 6} L{sub sun} and L{sub CND} {approx} 1.5 x 10{sup 6} L{sub sun} in the central 2 pc radius around Sgr A*. We find from the Herschel and ISO data that the cold component of the dust dominates the total dust mass, with a contribution of {approx}3.2 x 10{sup 4} M{sub sun}; this important cold material had escaped the notice of earlier studies that relied on shorter wavelength observations. The hotter component disagrees with some earlier estimates, but is consistent with measured gas temperatures and with models that imply shock heating or turbulent effects are at work. We find that the dust grain sizes apparently change widely across the region, perhaps in response to the temperature variations, and we map that distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Gravity waves as a probe of the Hubble expansion rate during an electroweak scale phase transition

Just as big bang nucleosynthesis allows us to probe the expansion rate when the temperature of the Universe was around 1 MeV, the measurement of gravity waves from electroweak scale first order phase transitions may allow us to probe the expansion rate when the temperature of the Universe was at the electroweak scale. We compute the simple transformation rule for the gravity wave spectrum under the scaling transformation of the Hubble expansion rate. We then apply this directly to the scenario of quintessence kination domination and show how gravity wave spectra would shift relative to Laser Interferometer Space Antenna and Big Bang Observer projected sensitivities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle transport and stochastic acceleration in the giant lobes of Centaurus A

The conditions within the giant lobes of Centaurus A are reviewed in light of recent radio and {gamma}-ray observations. Data from WMAP and ground-based telescopes in conjunction with measurements from Fermi-LAT constrain the characteristic field strength and the maximum electron energy. The implications for the transport of energetic particles are discussed in terms of residence times and cooling times within the lobes. Acceleration of electrons and UHECR via the second order Fermi mechanism is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GROWTH OF MASSIVE BLACK HOLES AT THEIR LATE STAGE

It is believed that the growth of local massive black holes was dominated by accretion during quasar phases, while a fraction of the local black hole mass was accumulated through accreting gases at very low rates. We derive the black hole mass density as a function of redshift with the bolometric luminosity function of active galactic nuclei (AGNs) assuming that massive black holes grew via accreting the circumnuclear gases, in which the derived black hole mass density is required to match the measured local black hole mass density at z = 0. Advection-dominated accretion flows (ADAFs) are supposed to be present in low-luminosity AGNs/normal galaxies, which are very hot and radiate mostly in the hard X-ray band. Most of the X-ray background (XRB) is contributed by bright AGNs, and a variety of AGN population synthesis models were developed to model the observed XRB in the last two decades. Based on our derived black hole mass density, we calculate the contribution to the XRB from the ADAFs in faint AGNs/normal galaxies with a given Eddington ratio distribution, which is mostly in the hard X-ray energy band with an energy peak at {approx}200 keV. The growth of massive black holes during the ADAF phase can therefore be constrained with the observed XRB. Combining an AGN population synthesis model with our results, we find that the fitting on the observed XRB, especially at the hard X-ray energy band with {approx_gt}100 keV, is improved provided the contribution of the ADAFs in low-luminosity AGNs/normal galaxies is properly included. It is found that less than {approx}15% of local massive black hole mass density was accreted during ADAF phases. We suggest that more accurate measurements of the XRB in the energy band with {approx_gt}100 keV in the future may help constrain the growth of massive black holes at their late stage. We also calculate their contribution to the extragalactic {gamma}-ray background (EGRB), and find that less than {approx}1% of the observed EGRB is contributed by the ADAFs in these faint sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of H{sub {alpha}} and the H{sub {beta}} lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MEASURING THE SPIN OF GRS 1915+105 WITH RELATIVISTIC DISK REFLECTION

GRS 1915+105 harbors one of the most massive known stellar black holes in the Galaxy. In 2007 May, we observed GRS 1915+105 for approx117 ks in the low/hard state using Suzaku. We collected and analyzed the data with the Hard X-ray Detector/Positive Intrinsic Negative and X-ray Spectrometer cameras spanning the energy range from 2.3 to 55 keV. Fits to the spectra with simple models reveal strong disk reflection through an Fe K emission line and a Compton backscattering hump. We report constraints on the spin parameter of the black hole in GRS 1915 + 105 using relativistic disk reflection models. The model for the soft X-ray spectrum (i.e., < 10 keV) suggests a-hat=0.56{sup +0.02}{sub -0.02} and excludes zero spin at the 4sigma level of confidence. The model for the full broadband spectrum suggests that the spin may be higher, a-hat=0.98{sup +0.01}{sub =0.01} (1sigma confidence), and again excludes zero spin at the 2sigma level of confidence. We discuss these results in the context of other spin constraints and inner disk studies in GRS 1915 + 105.

79 ASTRONOMY AND ASTROPHYSICS↗

Indoor And Outdoor Gamma Dose Measurements For Specific Counties of Trabzon-Turkey

In this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose . Average indoor and outdoor gamma dose rates were ascertained to be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 muSv/y and 73.83 muSv/y, respectively.

54 ENVIRONMENTAL SCIENCES↗

Measurement of radio wave reflection due to temperature rising from rock salt and ice irradiated by an electron beam for an ultra-high-energy neutrino detector

An ultra-high-energy neutrino (UHE{nu}) gives temperature rise along the hadronic and electromagnetic shower when it enters into rock salt or ice. Permittivities of them arise with respect the temperatures at ionization processes of the UHE{nu} shower. It is expected by Fresnel's formula that radio wave reflects at the irregularity of the permittivity in the medium. We had found the radio wave reflection effect in rock salt. The reflection effect and long attenuation length of radio wave in rock salt and ice would yield a new UHE{nu} detection method. An experiment for ice was performed to study the reflection effect. A coaxial tube was filled with rock salt powder or ice. Open end of the coaxial tube was irradiated by a 2 MeV electron beam. Radio wave of 435 MHz was introduced to the coaxial tube. We measured the reflection wave from the open end. We found the radio wave reflection effect due to electron beam irradiation in ice as well as in rock salt.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data collapse of the spectra of water-based stable single-bubble sonoluminescence

In the early days of stable single-bubble sonoluminescence, it was strongly debated whether the emission was blackbody radiation or whether the bubble was transparent to its own radiation (volume emission). Presently, the volume emission picture is nearly universally accepted. We present new measurements of spectra with apparent color temperatures ranging from 6000 to 21 000 K. We show through data collapse that within experimental uncertainty, apart from a constant, the spectra of strongly driven stable single-bubble sonoluminescence in water can be written as the product between a universal function of wavelength and a functional form that only depends on wavelength and apparent temperature but has no reference to any other parameter specific to the experimental situation. This remarkable result does question our theoretical understanding of the state of the plasma in the interior of strongly driven stable sonoluminescent bubbles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗