Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed power generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of a Flexible Space Antenna: A Finite Dimensional Perspective Based on Distributed Parameter Theory

The methods presented are based on results from infinite dimensional control theory, but they can be described and used in a finite dimensional context. This blend leads to an approach which employs powerful ideas on convergence, and is also quite practical for systems of realistic complexity. Appropriate reduced order models are generated simultaneously with the development of the compensator. The required models change as a function of changes in the performance demanded, sensor and actuator location, inherent damping, disturbances, etc. Thus they are driven by the control and estimation problems at hand. The compensators which emerge are very close to the ideal compensators which would be obtained with a very large order model. However, some simplification is frequently possible. The method of balanced realizations was found to be effective for this purpose.

Mingori, D. L.↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Coastal Community Resiliency Enhancement Using Marine Hydrokinetic (MHK) Resources and Networked Microgrids

Enormous challenges are inherent in the operation of modern distribution grids. In particular, distribution feeders can be severely compromised under extreme conditions such as large-scale weather events (e.g., hurricanes, floods, and other types of natural disasters). To combat this problem, they turn to local energy support from distributed energy resources, such as solar and wind, marine hydrolinetic (MHK), and other types of energy. In this report, we investigate the actual characteristics of MHK resources to enhance coastal community resiliency. Two typical types of MHK resources (i.e., wave and tidal resources) illustrate the coastal resilience enhancement framework. By identifying their operational characteristics, such as target time-scales and potential power generation variations, we detail a holistic coastal community resiliency enhancement framework that integrates both optimization and control efforts. The optimization problem is formulated to significantly minimize the power outage time at the critical infrastructures in coastal communities by implementing multiple autonomous and dynamic microgrids around MHK resources. Therefore, during severe power outages caused by natural disasters (e.g., floods, hurricanes), the coastal community load profiles can be satisfied using local MHK resources in each microgrid with limited or no power support from upstream power grids.

16 TIDAL AND WAVE POWER↗

Energy storage emerging: A perspective from the Joint Center for Energy Storage Research

Energy storage is an integral part of modern society. A contemporary example is the lithium (Li)-ion battery, which enabled the launch of the personal electronics revolution in 1991 and the first commercial electric vehicles in 2010. Most recently, Li-ion batteries have expanded into the electricity grid to firm variable renewable generation, increasing the efficiency and effectiveness of transmission and distribution. Important applications continue to emerge including decarbonization of heavy-duty vehicles, rail, maritime shipping, and aviation and the growth of renewable electricity and storage on the grid. This perspective compares energy storage needs and priorities in 2010 with those now and those emerging over the next few decades. The diversity of demands for energy storage requires a diversity of purpose-built batteries designed to meet disparate applications. Advances in the frontier of battery research to achieve transformative performance spanning energy and power density, capacity, charge/discharge times, cost, lifetime, and safety are highlighted, along with strategic research refinements made by the Joint Center for Energy Storage Research (JCESR) and the broader community to accommodate the changing storage needs and priorities. Innovative experimental tools with higher spatial and temporal resolution, in situ and operando characterization, first-principles simulation, high throughput computation, machine learning, and artificial intelligence work collectively to reveal the origins of the electrochemical phenomena that enable new means of energy storage. This knowledge allows a constructionist approach to materials, chemistries, and architectures, where each atom or molecule plays a prescribed role in realizing batteries with unique performance profiles suitable for emergent demands.

Trahey, Lynn↗

Learning-Accelerated ADMM for Distributed DC Optimal Power Flow

We propose a novel data-driven method to accelerate the convergence of Alternating Direction Method of Multipliers (ADMM) for solving distributed DC optimal power flow (DC-OPF) where lines are shared between independent network partitions. Using previous observations of ADMM trajectories for a given system under varying load, the method trains a recurrent neural network (RNN) to predict the converged values of dual and consensus variables. Given a new realization of system load, a small number of initial ADMM iterations is taken as input to infer the converged values and directly inject them into the iteration. We empirically demonstrate that the online injection of these values into the ADMM iteration accelerates convergence by a significant factor for partitioned 14-, 118- and 2848-bus test systems under differing load scenarios. The proposed method has several advantages: it maintains the security of private decision variables inherent in consensus ADMM; inference is fast and so may be used in online settings; RNN-generated predictions can dramatically improve time to convergence but, by construction, can never result in infeasible ADMM subproblems; it can be easily integrated into existing software implementations. While we focus on the ADMM formulation of distributed DC-OPF in this paper, the ideas presented are naturally extended to other distributed optimization problems.

alternating direction method of multipliers↗

Optimal Portfolio Design of Distributed Energy Resources on Puerto Rico Distribution Feeders with Long Outages after Hurricane Maria

This work details a project to design reliable, resilient, and cost-effective networked microgrids considering grid constraints and resilience metrics focused on Puerto Rico distribution feeder locations with long outages after Hurricane Maria. The project consisted primarily of modeling and simulation tasks that accomplished the following objectives: 1. Selected 10 distribution feeder models in vulnerable areas. The sample feeders are geographically distributed across Puerto Rico and vary in length to capture the wide variety of feeders on the island. 2. Determined the optimal location and sizing of distributed energy resources (DERs) on the identified distribution feeders. The systems considered as part of the microgrid solutions were solar photovoltaic (PV), battery energy storage systems (BESS) and distributed fossil fuel generation (DFFG). 3. Estimated the cost-benefit of the proposed DER portfolios. 4. Provided a set of final recommendations that inform decision making on how to do targeted planning analysis for microgrids that can supply energy to critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Environmental Co‐Benefits of Maintaining Native Vegetation With Solar Photovoltaic Infrastructure

Abstract Co‐locating solar photovoltaics with vegetation could provide a sustainable solution to meeting growing food and energy demands. However, studies quantifying multiple co‐benefits resulting from maintaining vegetation at utility‐scale solar power plants are limited. We monitored the microclimate, soil moisture, panel temperature, electricity generation and soil properties at a utility‐scale solar facility in a continental climate with different site management practices. The compounding effect of photovoltaic arrays and vegetation may homogenize soil moisture distribution and provide greater soil temperature buffer against extreme temperatures. The vegetated solar areas had significantly higher soil moisture, carbon, and other nutrients compared to bare solar areas. Agrivoltaics in agricultural areas with carbon debt can be an effective climate mitigation strategy along with revitalizing agricultural soils, generating income streams from fallow land, and providing pollinator habitats. However, the benefits of vegetation cooling effects on electricity generation are rather site‐specific and depend on the background climate and soil properties. Overall, our findings provide foundational data for site preservation along with targeting site‐specific co‐benefits, and for developing climate resilient and resource conserving agrivoltaic systems.

14 SOLAR ENERGY↗

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control

With increasing penetrations of volatile renewable generation and cyber-physical disruptions, ensuring the safe operation of bulk power systems has become unprecedentedly challenging. Because communication and computational costs restrict centralized system dispatch to being called upon every few minutes, and because purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. The applicability of distributed control schemes, however, is fundamentally limited by their need for widespread communication and model cognizance. In this context, we put forth a hybrid, low-communication, saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a "hotline" communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, whereas severe violations can be handled by collaboration among a relatively small set of agents. We evaluate the performance of this scheme via numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of load variations and severe low-/high-voltage events.

collaboration↗

Analysis of a Mars-stationary orbiting microwave power transmission system

To determine the feasibility of providing efficient RF power transmission from a Mars-stationary orbit to the surface of the planet, an assessment was made focussing on RF propagation in the 2.45- to 300-GHz range. The proposed orbiting system configuration provides for power generation by either photovoltaic array or nuclear reactor, the conversion of the dc output to RF, and subsequent propagation of RF energy from the orbiting array to the Martian surface. On the planet, a rectenna array will convert RF to dc power to be distributed for planetary power needs. Total efficiency of the energy conversion chain from dc to RF in orbit through RF to dc on the planetary surface was derived for several representative frequencies in the range of study. Tradeoffs between component efficiency and transmitting antenna requirements were considered for each of these frequencies. Rectenna element power density thresholds and desired received power levels were used to determine receiving antenna criteria. Recommendations are presented for research into developing technologies which may afford enhanced viability of the proposed microwave power transmission system.

Long, Kenwyn J.↗

Investigation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications

This paper addresses the progress of technology development of a laser ignition system at NASA Marshall Spac Flight Center (MSFC). Initial hot-fire tests in a small-scale rocket chamber at MSFC have demonstrated the dual pulse laser-induced spark (DPLIS) technique, which has an advantage over existing single-pulse laser ignition techniques in that it can be optimized in its laser pulse format to maximize the initial plasma volume, the plasm: lifetime, as well as the flame kernel growth rate. The distribution of the total laser energy into two separate pulse also lowers the peak power that would need to be sent through fiber optics to the combustion chamber, making the implementation of this technique more practical than other single-pulse techniques. A first generation prototype of an optic fiber-coupled laser ignition system will be tested a rocket chamber with RP-1/GOX and GH2/GOX propellants systems. Other relevant technology, such as optical windows, flight-qualified laser system etc. will be discussed in this paper.

Trinh, Huu P.↗

Achieving American Leadership in the Electric Grid Supply Chain Factsheet

The U.S. electric grid consists of more than 22,000 generators; 55,000 substations; 642,000 miles of high-voltage lines; and 6.3 million miles of distribution lines that serve 153 million customers. To date, much of the smart grid transformation has focused on applying advanced digital information and communication technologies to the power grid to improve the system’s efficiency, flexibility, and security. To achieve the full value of grid modernization, we also need advances in grid hardware. Many critical components supporting the power grid have limited to no domestic manufacturing capacity and face complex challenges in supporting a rapid expansion of the grid to meet multiple objectives, including decarbonization goals.

Source record↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FLISR in the Presence of DERs ADMS Test Bed Use Case

Fault location, isolation, and restoration (FLISR) is one of the distribution automation applications that utilities are most interested in. It operates groups of switches on distribution feeders to improve the reliability of power delivery after localizing outages. FLISR is an essential function for enabling a self-healing grid, and it directly affects grid reliability and resilience. The presence of DERs brings both new opportunities and challenges for FLISR applications. For instance, some DERs can work as backup generation sources and help energize local networks so more switching options can be achieved with the coordination of FLISR operations; however, the existence of DERs also brings new challenges. The bidirectional power flow resulting from DERs might require dynamic changes to protective devices' fault current settings, and thus the FLISR application will need to dynamically adjust its operations in coordination with the dynamic protection settings. Also, some FLISR applications make their service restoration decisions and close tie-switches based on predefined rules; however, the presence of DERs and their impact on altering net loads on the local feeder network are not considered. For this use case, the project team is using the FLISR application of the Survalent ADMS operating on a real-time simulation of a feeder from Central Georgia EMC, a cooperative electric utility. The performance of the FLISR application is being evaluated for different locations and combinations of DERs, including grid-forming battery energy storage systems.

ADMS↗