Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MODIS Solar Diffuser Attenuation Screen Modeling Results

On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.

Waluschka, Eugene↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Quantum-dot doped polymeric scintillation material for radiation detection

In this study, scintillation and luminescence enhancement were observed in a Quantum Dot-doped scintillating polymer, facilitating energy transfer with polymer medium and scintillating dye. 2,5-diphenyloxazole (PPO) and Cadmium Sulfide (CdS) Quantum Dots (QD) with 418 nm emission coated with oleic acid were dispersed in a polyvinyl toluene (PVT) matrix with transparency retained. Under UV excitation a sharp emission was detected at 426 nm from minimal QD loading with possible indication of QD energy transfer. Scintillation enhancement was observed with different radioactive sources in PVT-PPO/QD polymer with a photomultiplier detector setup. The response to gamma and beta radiation was investigated with differences in the energy spectrum and a count increase observed with increased QD loading.

36 MATERIALS SCIENCE↗

Biomass Fast Pyrolysis Using a Novel Microparticle Microreactor Approach: Effect of Particles Size, Biomass Type, and Temperature

Biomass fast pyrolysis is emerging as a front-running approach for the generation of renewable chemical and fuel resources. The pyrolysis temperature, solid and gas phase residence times, and biomass particle size and type have a substantial impact on char, oil and gas yields. A laboratory-scale fast pyrolysis technique was demonstrated using manufactured biomass microspheres. A unique single-particle (~10µg) micro-reactor technology coupled to a millisecond response flame ionization detector (fast-FID) was used to investigate the effects of relevant particle and process parameters and to capture the dynamic of real-time micro-scale single-particle pyrolysis for the first time. The manufactured biomass microspheres were produced by spray drying finely milled microcrystalline cellulose, switchgrass (Panicum virgatum) and tall fescue straw (Festuca arundinacea) flour. Keywords: biomass; fast pyrolysis; single particle; cellulose; switchgrass; tall fescue; flame ionization

Zolghadr, Ali↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

Nucleation-controlled growth of superior lead-free perovskite Cs 3 Bi 2 I 9 single-crystals for high-performance X-ray detection

The organic-inorganic hybrid lead halide perovskites have emerged as a series of star materials for solar cells, lasers and detectors. However, the issues raised by the toxic lead element and marginal stability due to the volatile organic components have severely limited their potential applications. In this work, we develop a nucleation-controlled solution method to grow large size high-quality Cs 3 Bi 2 I 9 perovskite single crystals (PSCs). Using the technique, we harvest some centimeter-sized single crystals and achieved high device performance. We find that X-ray detectors based on PSCs exhibit high sensitivity of 1652.3 μC Gy air -1 cm -2 and very low detectable dose rate of 130 nGy air s -1 , both desired in medical diagnostics. In addition, its outstanding thermal stability inspires us to develop a high temperature X-ray detector with stable response at up to 100 °C. Furthermore, PSCs exhibit high X-ray imaging capability thanks to its negligible signal drifting and extremely high stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The electron catcher (EC) of SciBooNE

In this paper we describe the electromagnetic calorimeter of the SciBooNE experiment. First we will give some technical details and then we will describe the response of this detector to electrons and muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Nuclear Response of {sup 56}Fe to Supernova Neutrino Spectra

Neutral current cross sections of scattering of {nu}{sub e} on the nuclear isotope {sup 56}Fe, which play a significant role in astrophysical neutrino studies, are used in order to explore the response of this detector to supernova neutrino spectra. We assume a two-parameter Fermi-Dirac distribution for the supernova neutrino spectra and evaluate the flux averaged cross sections for various values of the neutrino temperature and chemical potential parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep-ultraviolet photodetectors from epitaxially grown Ni{sub x}Mg{sub 1-x}O

Deep-ultraviolet (DUV) photodetectors were fabricated from high quality Ni{sub x}Mg{sub 1-x}O epitaxially grown by plasma-assisted molecular beam epitaxy on an approximately lattice matched MgO <100> substrate. A mid-range Ni composition (x=0.54) Ni{sub x}Mg{sub 1-x}O film was grown for DUV ({lambda}{sub peak}<300 nm) photoresponse and the film was characterized by reflected high-energy electron diffraction, Rutherford backscattering spectroscopy, x-ray diffraction, and optical transmission measurements. Photoconductive detectors were then fabricated by deposition of symmetric interdigitated contacts (10 nm Pt/150 nm Au) with contact separations of 5, 10, and 15 {mu}m. The detectors exhibited peak responsivities in the DUV ({lambda}{sub peak{approx_equal}}250 nm) as high as 12 mA/W, low dark currents (I{sub dark}<25 nA), and DUV:visible rejection ratio of approximately 800:1.

36 MATERIALS SCIENCE↗

Single-charge detection by an atomic precision tunnel junction

We demonstrate sensitive detection of single charges using a planar tunnel junction 8.5 nm wide and 17.2 nm long defined by an atomically precise phosphorus doping profile in silicon. The conductance of the junction responds to a nearby gate potential and also to changes in the charge state of a quantum dot patterned 52 nm away. The response of this detector is monotonic across the entire working voltage range of the device, which will make it particularly useful for studying systems of multiple quantum dots. The charge sensitivity is maximized when the junction is most conductive, suggesting that more sensitive detection can be achieved by shortening the length of the junction to increase its conductance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient and robust quantum random number generation by photon number detection

We present an efficient and robust quantum random number generator based upon high-rate room temperature photon number detection. We employ an electric field-modulated silicon avalanche photodiode, a type of device particularly suited to high-rate photon number detection with excellent photon number resolution to detect, without an applied dead-time, up to 4 photons from the optical pulses emitted by a laser. By both measuring and modeling the response of the detector to the incident photons, we are able to determine the illumination conditions that achieve an optimal bit rate that we show is robust against variation in the photon flux. We extract random bits from the detected photon numbers with an efficiency of 99% corresponding to 1.97 bits per detected photon number yielding a bit rate of 143 Mbit/s, and verify that the extracted bits pass stringent statistical tests for randomness. Our scheme is highly scalable and has the potential of multi-Gbit/s bit rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the CMS Zero Degree Calorimeters in pPb collisions at the LHC

The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at ± 140 m from the collision point and detect neutral particles in the |η| > 8.3 pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generative adversarial networks for scintillation signal simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network — a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. Furthermore, the network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

47 OTHER INSTRUMENTATION↗