Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Probing Metal–Organic Framework Design for Adsorptive Natural Gas Purification

Parent and amine-functionalized analogues of metal–organic frameworks (MOFs), UiO-66(Zr), MIL-125(Ti), and MIL-101(Cr), were evaluated for their hydrogen sulfide (H 2 S) adsorption efficacy and post-exposure acid gas stability. Adsorption experiments were conducted through fixed-bed breakthrough studies utilizing multicomponent 1% H 2 S/99% CH 4 and 1% H 2 S/10% CO 2 /89% CH 4 natural gas simulant mixtures. Instability of MIL-101(Cr) materials after H 2 S exposure was discovered through powder X-ray diffraction and porosity measurements following adsorbent pelletization, whereas other materials retained their characteristic properties. Linker-based amine functionalities increased H 2 S breakthrough times and saturation capacities from their parent MOF analogues. Competitive CO 2 adsorption effects were mitigated in mesoporous MIL-101(Cr) and MIL-101–NH 2 (Cr), in comparison to microporous UiO-66(Zr) and MIL-125(Ti) frameworks. This result suggests that the installation of H 2 S binding sites in large-pore MOFs could potentially enhance H 2 S selectivity. In situ Fourier transform infrared measurements in 10% CO 2 and 5000 ppm H 2 S environments suggest that framework hydroxyl and amine moieties serve as H 2 S physisorption sites. In conclusion, results from this study elucidate design strategies and stability considerations for engineering MOFs in sour gas purification applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo Studies for the Radiation Shielding Design of LCLS-II

Intensive Monte Carlo simulations performed with state-of-the-art computation codes are applied to the radiation shielding design of LCLS-II, which will be the extension of Linac Coherent Light Source (LCLS) at SLAC and will use the middle one-third of SLAC two-mile Linac. This paper describes the Monte Carlo studies of the first and last system where electron beams are involved, namely the LCLS-II Injector and the X-ray Transport and Diagnostics System (XTOD).

43 PARTICLE ACCELERATORS↗

Improved DC Gun and Insulator Assembly

Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

43 PARTICLE ACCELERATORS↗

AGR-3/4 Irradiation Test Train Disassembly and Component Metrology First Look Report

The AGR-3/4 experiment was designed to study fission product transport within graphitic matrix material and nuclear-grade graphite. To this end, this experiment consisted of 12 capsules, each fueled with 4 compacts containing UCO TRISO particles as driver fuel and 20 UCO designed-to-fail (DTF) fuel particles in each compact. The DTF fuel was fabricated with a thin pyrocarbon layer which was intended to fail during irradiation and provide a source of fission products. These fission products could then migrate through the compact and into the surrounding concentric rings of graphitic matrix material and/or nuclear graphite. Through post-irradiation examination (PIE) of the rings (including physical sampling and gamma scanning) fission product concentration profiles within the rings can be determined. These data can be used to elucidate fission product transport parameters (e.g. diffusion coefficients within the test materials) which will be used to inform and refine models of fission product transport. After irradiation in the Advanced Test Reactor (ATR) had been completed in April 2014, the AGR-3/4 experiment was shipped to the Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) for inspection, disassembly, and metrology. The AGR-3/4 test train was received at MFC in two separate shipments between February and April 2015. Visual examinations of the test train exterior did not indicate dimensional distortion, and only two small discolored areas were observed at the bottom of Capsules 8 and 9. No corresponding discoloration was found on the inside of these capsules, however. Prior to disassembly, the two test train sections were subject to analysis via the Precision Gamma Scanner (PGS), which did not indicate that any gross fuel relocation had occurred. A series of specialized tools (including clamps, cutters, and drills) had been designed and fabricated in order to carry out test train disassembly and recovery of capsule components (graphite rings and fuel compacts). This equipment performed well for separating each capsule in the test train and extracting the capsule components. Only a few problems were encountered. In one case, the outermost ring (the sink ring) was cracked during removal of the capsule through tubes. Although the sink ring will be analyzed in order to obtain a mass balance of fission products in the experiment, these cracks do not pose a major concern because the sink ring will not be analyzed in detail to obtain the spatial distribution of fission products. In Capsules 4 and 5, the compacts could not be removed from the inner rings. Strategies for removing the compacts are being evaluated. Sampling the inner rings with the compacts in-place is also an option. Dimensional measurements were made on the compacts, inner rings, outer rings, and sink rings. The diameters of all compacts decreased by 0.5 to 2.0 %. Generally, the extent of diametric shrinkage increased linearly with increasing neutron fluence. Most compact lengths also decreased. Compact lengths decreased with increasing fluence, reaching maximum shrinkage of about 0.9 % at a fast fluence of 4.0x10 25 n/m 2 E > 0.18 MeV. Above this fluence, the extent of length shrinkage appeared to decrease with fluence, and two compacts from Capsule 7 were found to have slightly increased in length (< 0.1 %) after a fluence of 5.2x10 25 n/m 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGR-3/4 Irradiation Test Train Disassembly and Component Metrology First Look Report

The AGR-3/4 experiment was designed to study fission product transport within graphitic matrix material and nuclear-grade graphite. To this end, this experiment consisted of 12 capsules, each fueled with 4 compacts containing UCO TRISO particles as driver fuel and 20 UCO designed-to-fail (DTF) fuel particles in each compact. The DTF fuel was fabricated with a thin pyrocarbon layer which was intended to fail during irradiation and provide a source of fission products. These fission products could then migrate through the compact and into the surrounding concentric rings of graphitic matrix material and/or nuclear graphite. Through post-irradiation examination (PIE) of the rings (including physical sampling and gamma scanning) fission product concentration profiles within the rings can be determined. These data can be used to elucidate fission product transport parameters (e.g. diffusion coefficients within the test materials) which will be used to inform and refine models of fission product transport. After irradiation in the Advanced Test Reactor (ATR) had been completed in April 2014, the AGR-3/4 experiment was shipped to the Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) for inspection, disassembly, and metrology. The AGR-3/4 test train was received at MFC in two separate shipments between February and April 2015. Visual examinations of the test train exterior did not indicate dimensional distortion, and only two small discolored areas were observed at the bottom of Capsules 8 and 9. No corresponding discoloration was found on the inside of these capsules, however. Prior to disassembly, the two test train sections were subject to analysis via the Precision Gamma Scanner (PGS), which did not indicate that any gross fuel relocation had occurred. A series of specialized tools (including clamps, cutters, and drills) had been designed and fabricated in order to carry out test train disassembly and recovery of capsule components (graphite rings and fuel compacts). This equipment performed well for separating each capsule in the test train and extracting the capsule components. Only a few problems were encountered. In one case, the outermost ring (the sink ring) was cracked during removal of the capsule through tubes. Although the sink ring will be analyzed in order to obtain a mass balance of fission products in the experiment, these cracks do not pose a major concern because the sink ring will not be analyzed in detail to obtain the spatial distribution of fission products. In Capsules 4 and 5, the compacts could not be removed from the inner rings. Strategies for removing the compacts are being evaluated. Sampling the inner rings with the compacts in-place is also an option. Dimensional measurements were made on the compacts, inner rings, outer rings, and sink rings. The diameters of all compacts decreased by 0.5 to 2.0 %. Generally, the extent of diametric shrinkage increased linearly with increasing neutron fluence. Most compact lengths also decreased. Compact lengths decreased with increasing fluence, reaching maximum shrinkage of about 0.9 % at a fast fluence of 4.0x1025 n/m2 E > 0.18 MeV. Above this fluence, the extent of length shrinkage appeared to decrease with fluence, and two compacts from Capsule 7 were found to have slightly increased in length (< 0.1 %) after a fluence of 5.2x1025 n/m2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Alternate Design Concepts for the High Flux Isotope Reactor using Low-Enriched Uranium Fuel Systems: Scoping Analysis

The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) is a multi-mission research reactor dedicated mainly to isotope production, neutron scattering experiments, material irradiation, testing and activation. In the framework of non-proliferation policies, the international community is currently aiming to reduce or even eliminate, when and where possible, the use of Highly Enriched Uranium (HEU: 235 U/U ≥ 20 wt. %) in civilian applications. In that context, most research reactors worldwide still operating with HEU fuel are actively engaged in an effort to convert to Low Enriched Uranium fuel system (LEU: 235 U/U < 20 wt. %). Within the US, the High Performance Research Reactor (USHPRR) fleet (which includes HFIR) is expected to convert to LEU fuel using the UMo “monolithic” fuel system currently under development. ORNL is responsible for the development of a LEU design for HFIR. In the past years, Argonne National Laboratory (ANL) offered technical assistance to the ORNL LEU design team whenever deemed appropriate. Due to their complex nature, acceptable HFIR LEU designs identified so far, all based on the UMo monolithic fuel system, would require a substantial fabrication development effort before being proven commercially viable. In order to mitigate technical risks and reduce cost/schedule uncertainties, it appears appropriate to study alternate design solutions and alternate fuel systems as possible backup options for the HFIR conversion to LEU fuel. In that context, ANL has been exploring alternate design concepts for HFIR. Complementing the ORNL design activities, the goal is to find the best design solution for HFIR in term of cost, performance and safety. The present report summarizes the findings regarding two types of alternate conceptual design: U 3 Si 2 designs and un-contoured UMo design. Based on available tools and methods, preliminary analysis show that both concepts could probably meet performance and steady-state safety requirements but element fabrication would remain complex and would require a non-trivial fabrication development effort.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Local Control of Perivascular Malignant Liver Lesions Using Percutaneous Irreversible Electroporation: Initial Experiences

PurposeThis study was designed to assess efficacy and safety in the treatment of perivascular malignant liver lesions using percutaneous, computed tomography (CT)-guided irreversible electroporation (IRE).MethodsFourteen patients (mean age 58 ± 11 years) with 18 malignant liver lesions were consecutively enrolled in this study. IRE was performed in patients not eligible for surgery and lesions abutting large vessels or bile ducts. Follow-up exams were performed using multislice-CT (MS-CT) or MRI.ResultsMedium lesion diameter was 20 ± 5 mm. Ten of 14 (71 %) were successfully treated with no local recurrence to date (mean follow-up 388 ± 160 days). One case left initial tumor control unclear and additional RFA was performed 4 weeks after IRE. Complications occurred in 4 of 14 (29 %) cases. In one case, intervention was terminated and abdominal bleeding required laparotomy. In two cases, a postinterventional hematothorax required intervention. In another case, abdominal bleeding could be managed conservatively. No complications related to the bile ducts occurred.ConclusionsPercutaneous IRE seems to be effective in perivascular lesions but is associated with a higher complication rate compared with thermoablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hormetic effect of methylmercury on Caenorhabditis elegans

Research has demonstrated the toxic effects of methylmercury (MeHg), yet molecular mechanisms underlying its toxicity are not completely understood. Caenorhabditis elegans (C. elegans) offers a unique biological model to explore mechanisms of MeHg toxicity given many advantages associated with its ease of use and genetic power. Since our previous work indicated neurotoxic resistance of C. elegans to MeHg, the present study was designed to examine molecular mechanisms associated with this resistance. We hypothesized MeHg would induce expression of gst, hsp or mtl in vivo since glutathione (GSH), heat shock proteins (HSPs), and metallothioneins (MTs) have shown involvement in MeHg toxicity. Our studies demonstrated a modest, but significant increase in fluorescence in gst-4::GFP and mtl-1::GFP strains at an acute, low L1 MeHg exposure, whereas chronic L4 MeHg exposure induced expression of gst-4::GFP and hsp-4::GFP. Knockout gst-4 animals showed no alterations in lethality sensitivity compared to wildtype animals whereas mtl knockouts displayed increased sensitivity to MeHg exposure. GSH levels were increased by acute MeHg treatment and depleted with chronic exposure. We also demonstrate that MeHg induces hormesis, a phenotype whereby a sublethal exposure to MeHg rendered C. elegans resistant to subsequent exposure to the organometal. The involvement of gst-4, hsp-4, mtl-1, and mtl-2 in hormesis was examined. An increase in gst-4::GFP expression after a low-dose acute exposure to MeHg indicated that gst-4 may be involved in this response. Our results implicate GSH, HSPs, and MTs in protecting C. elegans from MeHg toxicity and show a potential role of gst-4 in MeHg-induced hormesis.

60 APPLIED LIFE SCIENCES↗

Phenyl Functionalization of Atomically Precise Graphene Nanoribbons for Engineering Inter-ribbon Interactions and Graphene Nanopores

Graphene nanoribbons (GNRs) attract a great attention from researchers due to their tunable physical properties and potential for becoming nanoscale building blocks of electronic devices. GNRs can be synthesized with atomic precision by on-surface approaches from specially designed molecular precursors. While a considerable number of ribbons with very diverse structures and properties have been demonstrated in recent years, there have been only limited examples of on-surface synthesized GNRs modified with functional groups. In this study, we designed a nanoribbon, in which the chevron GNR backbone is decorated with phenyl functionalities, and demonstrate the on-surface synthesis of these GNRs on Au(111). We show that the phenyl modification affects the assembly of the GNR polymer precursors through π-π interactions. Scanning tunneling spectroscopy of the modified GNRs on Au(111) revealed that they have a band gap of 2.50±0.02 eV, which is comparable to that of the parent chevron GNR. The phenyl functionalization leads to a shift of the band edges to lower energies, suggesting that it could be a useful tool for the GNR band structure engineering. We also investigated lateral fusion of the phenyl-modified GNRs and demonstrate that it could be used to engineer different kinds of atomically precise graphene nanopores. A similar functionalization approach could be potentially applied to other GNRs to affect their on-surface assembly, modify their electronic properties, and realize graphene nanopores with a variety of structures.

47 OTHER INSTRUMENTATION↗

Association between the findings of metachronous secondary primary malignancies and the number of Lugol-voiding lesions

Summary This study was designed to evaluate the relation between dysplastic squamous epithelium in the esophageal mucosa and the development of metachronous secondary primary malignancies (mSPM) other than esophagus after endoscopic resection (ER) in patients with early esophageal squamous cell carcinoma (SCC). We studied 330 patients with early esophageal SCC who underwent ER as a post hoc analysis of a prospective multicenter cohort study (UMIN Clinical Trials Registry ID UMIN000001676). Lugol-voiding lesions (LVL) were graded into 3 categories (A = no lesion; B = 1 to 9 lesions; C ≥ 10 lesions). The following variables were studied: (i) the incidences of mSPM other than esophagus; (ii) the standardized incidence ratios (SIRs) of mSPM; (iii) the cumulative incidence and total number of mSPM other than esophagus; and (iv) predictors of mSPM other than esophagus on analysis with a multivariate Cox proportional-hazards model. After a median follow-up of 46.6 months, mSPM other than esophagus was diagnosed in a total of 73 patients (90 lesions). Among the 106 patients in group C, 37 patients had mSPM (51 lesions), including head and neck cancer in 14 patients (24 lesions) and gastric cancer in 12 patients (16 lesions). The SIR of mSPM was 3.61 in this study subjects. An increase in the LVL grade (A to B to C) was associated with a progressive increase in the cumulative incidence rate of mSPM other than esophagus (P = 0.017 for A vs. C, P = 0.023 for B vs. C). An increase in the LVL grade (A to B to C) was also associated with a progressive increase in the total number of mSPM other than esophagus per 100 person-years (primary events, relative risk [RR] = 1.66 and 3.24 for grades B and C, respectively, vs. A, P = 0.002 for trend; all events, RR = 1.81 and 4.66 for grades B and C, respectively, vs. A, P < 0.0001 for trend). LVL grade C was a strong predictor of mSPM other than esophagus (RR = 3.41 for A vs. C). LVL grade may be a useful predictor of the risk of mSPM other than esophagus after ER in patients with early esophageal SCC.

Katada, Chikatoshi↗

Beam Thrust Cross Section for Drell-Yan Production at Next-to-Next-to-Leading-Logarithmic Order

At the LHC and Tevatron strong initial-state radiation (ISR) plays an important role. It can significantly affect the partonic luminosity available to the hard interaction or contaminate a signal with additional jets and soft radiation. An ideal process to study ISR is isolated Drell-Yan production, pp{yields}Xl{sup +}l{sup -} without central jets, where the jet veto is provided by the hadronic event shape beam thrust {tau}{sub B}. Most hadron collider event shapes are designed to study central jets. In contrast, requiring {tau}{sub B}<<1 provides an inclusive veto of central jets and measures the spectrum of ISR. For {tau}{sub B}<<1 we carry out a resummation of {alpha}{sub s}{sup n}ln{sup m{tau}}{sub B} corrections at next-to-next-to-leading-logarithmic order. This is the first resummation at this order for a hadron-hadron collider event shape. Measurements of {tau}{sub B} at the Tevatron and LHC can provide crucial tests of our understanding of ISR and of {tau}{sub B}'s utility as a central jet veto.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Route-Specific Passage Proportions and Survival Rates for Fish Passing through John Day Dam, The Dalles Dam, and Bonneville Dam in 2010 and 2011

This report fulfills a request of the U.S. Army Engineer District, Portland, Oregon, to produce an interim report of estimates of route-specific fish passage proportions and survival rates for lower Columbia River dams in 2010 and 2011. The estimates are needed to update the Compass Model for the Columbia River Treaty and the new Biological Opinion before detail technical reports are published in late 2012. This report tabulates route-specific fish-passage proportions and survival rates for steelhead and Chinook salmon smolts passing through various sampled routes at John Day Dam, The Dalles Dam, and Bonneville Dam in 2010 and 2011. Results were compiled from analyses of data acquired in spring 2010 and 2011 studies that were specifically designed to estimate dam-passage and forebay-to-tailrace survival rates, travel time metrics, and spill passage efficiency, as stipulated by the 2008 Federal Columbia River Power System Biological Opinion and the Columbia Basin Fish Accords. The study designs allowed for estimation of route-specific fish passage proportions and survival rates as well as estimation of forebay-passage survival, all of which are summarized herein.

13 HYDRO ENERGY↗

Tissues from the Irradiated Dog/Mouse Archive

The purpose of this project is to organize the databases/information and organize and move the tissues from the long-term dog (4,000 dogs) and mouse (over 30,000 mice) radiation experiments done at Argonne National Laboratory during the 1970's and 80's to Northwestern University. These studies were done with the intention of understanding the effects of exposure to radiation at a variety of different doses, dose-rates, and radiation qualities on end-points such as life-shortening, carcinogenesis, cause of death, shifts in disease incidence and other biological parameters. Organ and tissue samples from these animals including cancers, metastases and other significant degenerative and inflammatory lesions and those in a regular protocol of normal tissues were preserved in paraffin blocks, tissue impressions and sections and represent a great resource for the radiation biology community. These collections are particularly significant since these experiments are not likely to be repeated because of the extreme cost of monies and time for such large-scale animal studies. The long-term goal is to make these tissues and databases available to the wider scientific community so that questions such as tissue sensitivity, early and late effects, low dose and protracted dose responses of normal and tumor tissues, etc. can be examined and defined. Recent advances in biology particularly at the subcellular and molecular level now permit microarray-based gene expression array analyses from paraffin-embedded tissues (where RNA samples are significantly degraded), synchrotron-based studies of metal and other elemental distribution patterns in tissues, PCR-based analyses for mutation detection, and other similar approaches that were not available when the long¬ term animal studies were designed and initiated. Understanding the basis and progression of radiation damage should also permit rational approaches to prevention and mitigation of those damages. Therefore, as stated earlier, these tissues and their related documentation, represent a significant resource for future studies. For this project, we propose to accomplish the following objectives: (1) inventory and organize the tissues, blood smears, wet-tissues and paper-based information that is available in the tissue bank at Argonne National Laboratory; (2) convert the existing Oracle database of the mouse studies to MS Access( the dog data is already in this format which is far more user friendly and widely used in business and research) , (3) move the remaining samples and documentation from dogs that had been transferred from ANL to New Mexico (in Dr. F. Hahn's care) to Northwestern University and add these to the inventory; (4) move the tissues and Access database at Argonne National Laboratory to Northwestern University.

59 BASIC BIOLOGICAL SCIENCES↗

A Liquid Metal Flume for Free Surface Magnetohydrodynamic Experiments

We present an experiment designed to study magnetohydrodynamic effects in free-surface channel flow. The wide aspect ratio channel (the width to height ratio is about 15) is completely enclosed in an inert atmosphere to prevent oxidization of the liquid metal. A custom-designed pump reduces entrainment of oxygen, which was found to be a problem with standard centrifugal and gear pumps. Laser Doppler Velocimetry experiments characterize velocity profiles of the flow. Various flow constraints mitigate secondary circulation and end effects on the flow. Measurements of the wave propagation characteristics in the liquid metal demonstrate the surfactant effect of surface oxides and the damping of fluctuations by a cross-channel magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SAM Co-Development to Support Fluoride-salt-cooled High-temperature Reactor Design and Licensing (CRADA 2018-18177 Final Report)

This project aims to raise the SAM code's technical and commercial maturity level to enable the Kairos Power ("Kairos") to use SAM to support its KP-FHR design analysis and licensing application. Argonne National Laboratory ("Argonne") has actively developed and maintained SAM, a modern system-level analysis tool for advanced nonlight water reactors safety analysis. Kairos is currently actively pursuing development of an FHR design and associated technology, and consequently requires a pedigreed safety analysis tool. The purpose of this project is to increase the maturity of the SAM code for the modeling and simulation of the KP-FHR design, thus enabling its use in safety analyses that support licensing application. Argonne will primarily be responsible for software design, development, and testing; while Kairos will be responsible for software requirements, assessment of software capabilities, needs, gaps, and priorities, and development of proprietary models. The research and development activities for the joint SAM development project include: a series of identification and prioritization studies on design characteristics, event sequences, relevant phenomena, and software capabilities; SAM capability enhancements for specific KP-FHR systems and components; performing code verification and validations; integrating uncertainty quantification (UQ), model calibration, and sensitivity analysis (SA) techniques in safety analyses; and raising the software quality rigor level for commercial-grade applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unilateral Versus Bilateral Prostatic Arterial Embolization for Lower Urinary Tract Symptoms in Patients with Prostate Enlargement

This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-{mu}m nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (group B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗