At least 1,369 records · Page 76

Radiation and Thermal Cycling Effects on EPC1001 Gallium Nitride Power Transistors

Electronics designed for use in NASA space missions are required to work efficiently and reliably under harsh environment conditions. These include radiation, extreme temperatures, and thermal cycling, to name a few. Information pertaining to performance of electronic parts and systems under hostile environments is very scarce, especially for new devices. Such data is very critical so that proper design is implemented in order to ensure mission success and to mitigate risks associated with exposure of on-board systems to the operational environment. In this work, newly-developed enhancement-mode field effect transistors (FET) based on gallium nitride (GaN) technology were exposed to various particles of ionizing radiation and to long-term thermal cycling over a wide temperature range. Data obtained on control (un-irradiated) and irradiated samples of these power transistors are presented and the results are discussed.

Patterson, Richard L.↗

Lessons from 18 Years of Hyperspectral Infrared Sounder Data

By the end of 2013 NASA and EUMETSAT will have accumulated more than 11 years of AIRS, 6 years of IASI and one year of CrIS data. All three instruments were nominally specified to support the NWC for short term weather forecasting with a five year lifetime, but continue to exceed the accuracy requirement needed for weather forecasting alone. This allows use of their data for a much broader range of applications, including the calibration of broad-band instruments in space and climate research. We illustrate calibration aspects with examples from AIRS, IASI and CrIS using spatially uniform clear conditions, simultaneous nadir overpasses and random nadir samples. The differences between AIRS, IASI and CrIS for the purpose of weather forecasting are small and we expect that the excellent forecast impact demonstrated by the combination of AIRS and IASI will be continued by the combination of CrIS and IASI. Clear data are useful for calibration, but contain no climate signal. The analysis of random nadir samples from AIRS and CrIS identifies larger biases for observation of extreme conditions, represented by 1% and 99%tile data than for non-extreme observations. This is relevant for climate analysis. Resolution of these differences require further work, since they can complicate the continuation of trends established by AIRS with CrIS data, at least for extrema. The unequaled stability of the AIRS data allows us to evaluate trends using random nadir sampled data. We see an increasing frequency in severe storms over land, a decreasing frequency over ocean. The 11 years of AIRS data are too short to tell if these trends are significant from a climate change viewpoint, or if they are parts of multi-decadal oscillations.

CRIS↗

Detection of DNA Damage by Space Radiation in Human Fibroblast Cells Flown on the International Space Station

Although charged particles in space have been detected with radiation detectors on board spacecraft since the early discovery of the Van Allen Belt, reports on effects of direct exposure to space radiation in biological systems have been limited. Measurement of biological effects of space radiation has been difficult due to the low dose and low dose rate nature of the radiation environment, and the difficulty in separating the radiation effects from microgravity and other space environmental factors. In astronauts, only a small number of changes, such as increased chromosome aberrations in lymphocytes and early onset of cataracts, attributed primarily to the exposure to space radiation. In a recent experiment, human fibroblast cells were flown on the International Space Station (ISS). Cells fixed on Days 3 and 14 after reaching orbit were analyzed for phosphorylation of a histone protein H2AX by immunofluorescent staining of cells, which is a widely used marker for DNA double strand breaks. The 3-dimensional gamma-H2AX foci were captured with a laser confocal microscope. Quantitative analysis revealed a small fraction of foci that were larger and displayed a track pattern in the flight samples in comparison to the ground control. Human fibroblast cells were also exposed to low dose rate gamma rays, as well as to protons and Fe ions. Comparison of the pattern and distribution of the foci after gamma ray and charged particle exposure to our flight results confirmed that the foci found in the flown cells were indeed induced by space radiation.

Wu, Honglu↗

Vanadium Valence in MgAl2O4 Spinels at Reducing Conditions (IW to IW-5)

Vanadium is commonly a major or minor element in spinel structured oxides from a wide range of planetary materials [1-3]. Vanadium is stable in multiple valence states of 5+, 4+, 3+, and 2+ in natural systems, and spinel-structured oxides are known to host vanadium in 4+, 3+, and 2+ [4-6]. However, the understanding of 2+ stability at lower fO2 conditions has been hindered by lack of experiments at or below IW-1 conditions [5]. Insufficient experimental data is available due to the difficulty in controlling fO2 at low conditions in general, and the lack of appropriate standards for comparison to natural materials. Our progress on controlling fO2 in high pressure experimental samples has allowed us to create reducing conditions that are appropriate to studying V valence in spinels at fO2 relevant to natural reducing systems [7]. Here we extend this approach to study V in reduced conditions, at high temperatures. After at-tempting shorter durations and lower temperatures, we demonstrated the need for equilibration times > 6 hours at 1600 °C in order to approach equilibrium. Only then can we produce highly equilibrated samples that provide new insights into V valence at low fO2.

oxygen fugacity↗

Surface Deposition of Molecular Contaminants in the Mars 2020 Rover Wake

The Mars 2020 rover has very strict contamination control requirements in order to prepare samples for a potential Mars Sample Return. It is known that the rover will out gas a low-level of molecular contaminant on the surface of Mars, and numerical simulations using STAR-CCM+ are performed in order to predict the magnitude of the contaminant deposition to the Martian surface in the vicinity of the rover. This is done in order to determine whether or not the M2020 rover could self-contaminate a potential sampling site if it were to remain in the same location for a long period of time. Simulations are performed under a variety of surface conditions, and it is determined that the predicted level of molecular contaminant deposition to the surface near the rover will not be a significant factor in the overall sample contamination budget.

Katz, Ira↗

Milestone 2.7: Evaluation of Techniques for the Measurement of Molecular Hydrogen Gas in Helium Matrices

Published data by Task 2 (Oxyhydroxide Layer Radiolytic Gas Generation Resolution) for Technical Considerations and Challenges for Extended (>50 yrs) Dry Storage of Aluminum Cladded Spent Nuclear Fuel (ASNF), demonstrated that radiolytic molecular hydrogen (H2) production from gamma irradiated aluminum alloy 1100 (Al-1100) coupons exhibited significant dependence on backfill gaseous environment conditions: air, due to the presence of oxygen, completely inhibited H2 production; nitrogen promoted H2 production; and argon yielded more H2 than nitrogen environments. The concern here is that helium has been proposed as the backfill gas for extended storage and is more inert than argon, which may translate into significantly more H2 production than current Task 3 argon-based models predict. However, the measurement of H2 in helium media was not possible using the previously establish gas chromatography (GC) flame ionization detector, due to similarities in thermal conductivity. This milestone was initiated to evaluate an alternative GC approach that employed a mercuric oxide (HgO) reduction gas detector (RGD). Using the HgO RGD setup, H2 was successfully calibrated in the presence of a helium carrier gas, and then subsequently measured in control and irradiated crush-tube sample vials, consistent with previous sample measurements. Overall, the HgO RGD approach was found to be sufficient for future helium environment irradiations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DESI DR1 Peculiar Velocity Survey: Fundamental Plane Catalogue

Measurements of peculiar velocities in the local Universe are a powerful tool to study the nature of dark energy at low ($z < 0.1$) redshifts. Here we present the largest single set of $z<0.1$ peculiar velocity measurements to date, obtained using the Fundamental Plane (FP) of galaxies in the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). We describe the photometric and spectroscopic selection criteria used to define the sample, as well as extensive quality control checks on the photometry and velocity dispersion measurements. Additionally, we perform detailed systematics checks for the many analysis parameters in our pipeline. Our DESI DR1 catalogue contains FP-based distances and peculiar velocities for $98,292$ unique early-type galaxies, increasing the total number of $z < 0.1$ FP distances ever measured by a factor of $\sim2$. We achieve a precision of $26\%$ random error in our distance measurements which is comparable to previous surveys. A series of companion DESI papers use the distances and peculiar velocities presented in this paper to measure cosmological parameters.

Ross, C. E. [Queensland U.]↗

Investigation of microgravity effects on solidification phenomena of selected materials

A Get Away Special (GAS) experiment payload to investigate microgravity effects on solidification phenomena of selected experimental samples has been designed for flight. It is intended that the first flight of the assembly will (1) study the p-n junction characteristics for advancing semiconductor device applications, (2) study the effects of gravity-driven convection on the growth of HgCd crystals, (3) compare the textures of the sample which crystallizes in microgravity with those found in chondrite meteorites, and (4) modify glass optical characteristics through divalent oxygen exchange. The space flight experiment consists of many small furnaces. While the experiment payload is in the low gravity environment of orbital flight, the payload controller will sequentially activate the furnaces to heat samples to their melt state and then allow cooling to resolidification in a controlled fashion. The materials processed in the microgravity environment of space will be compared to the same materials processed on earth in a one-gravity environment. This paper discusses the design of all subassemblies (furnance, electronics, and power systems) in the experiment. A complete description of the experimental materials is also presented.

Maag, Carl R.↗

Following O and OH in He/O 2 and He/H 2 O gas mixtures—from the gas phase through the liquid phase to modifications on a biological sample

Abstract Applied cold atmospheric plasma allows for the controlled delivery of reactive oxygen and nitrogen species tailored for specific applications. Through the manipulation of the plasma parameters, feed gases, and careful consideration of the environment surrounding the treatment target, selective chemistries that preferentially influence the target can be produced and delivered. To demonstrate this, the COST reference microscale atmospheric pressure plasma jet is used to study the generation and transport of O and ⋅ OH from the gas phase through the liquid to the biological model target cysteine. Relative and absolute species densities of ⋅ OH and O are measured in the gas phase through laser induced fluorescence (LIF) and two-photon absorption LIF respectively. The transport of these species is followed into the liquid phase by hydrogen peroxide quantification and visualized by a fluorescence assay. Modifications to the model biological sample cysteine exposed to ⋅ OH and H 2 O 2 dominated chemistry (He/H 2 O (0.25%)) and O dominated chemistry (He/O 2 (0.6%)) is measured by FTIR spectroscopy. The origin of these species that modify cysteine is considered through the use of heavy water (H 2 18 O) and mass spectrometry. It is found that the reaction pathways differ significantly for He/O 2 and He/H 2 O. Hydrogen peroxide is formed mainly in the liquid phase in the presence of a substrate for He/O 2 whereas for He/H 2 O it forms in the gas phase. The liquid chemistry resulting from the He/O 2 admixture mainly targets the sulfur moiety of cysteine for oxidation up to irreversible oxidation states, while He/H 2 O treatment leads preferentially to reversible oxidation products. The more O or OH/H 2 O 2 dominated chemistry produced by the two gas admixtures studied offers the possibility to select species for target modification.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Genesis Solar Wind – Capture, Return, Curate and Analyze: Looking Backward and Creating a Timeline

Introduction: In 1997 NASA’S Discovery Program selected the Genesis mission proposal to return solar wind samples to Earth for laboratory analyses. Principal Investigator Donald S. Burnett and the science team defined the purity of collector materials and ability to analyze solar wind composition to the precision required for planetary science. As a small mission, focused on a well-defined science goal, yet needing careful attention to engineering details, the communication among scientists and engineers, nurtured by Don Burnett, was exceptional. Genesis Mission and Curation Legacy: Genesis, as the first U. S. spacecraft to return astromaterial samples since Apollo, not only integrated the mission planning and flight teams, but also the science and sample curation teams during the mission development period. Since Genesis is a sample return mission, the Science Team was essential in certifying the collectors (sample containers for solar atoms). From inception, Genesis established mission funding for returned sample curation. JSC was lead in contamination control during mission preparation, including establishment of an ISO 4 cleanroom facility and use of ultrapure water (UPW) for cleaning flight hardware (and, as it turned out, for cleaning collectors after the mishap). Reliable, fast communication among scientists, engineers and curators at the hands-on level established deep respect among team members and efficient decision-making. JSC’s 50-years of astromaterial sample curation provided experienced sample processors onsite during recovery in Utah (a deep bench for emergency response). Post-recovery curation included iterative collaboration with science sample users to clean or verify cleanliness of samples. The science legacy from Genesis is addressed by Burnett and Jurewicz, this volume. In The Beginning: After Apollo sample return, Burnett and Marcia Neugebauer at JPL began discussing a solar wind sample return, with Neugebauer arguing that separate collection of solar wind regimes was essential science. By 1992 a solar wind sample return mission was presented at a workshop, and by 1994 a mission was proposed named Suess-Urey. The mission was re-proposed under a new name GENESIS and selected in 1997. Susan Niebur captured the Genesis mission history and stories, from high level management documents and from many interviews with participants [2]. Her account lets readers glimpse personality of participants in quotations from interviews. Need and Scope for Detailed Technical Timeline: A timeline constructed from lower level task documents has been initiated to document the resources and skills actually used, as well as task sequence or concurrency. Timelines for high level mission events are captured in two documents [1] [2] and for detailed re-entry events in [3]. A detailed technical timeline for Genesis mission and curation activities will provide data points for lower level tasks, such as ISO 4 curation facility construction time, preparation for nominal sample field recovery, mishap recovery, and UPW expansion. Changes in technology context 1990-2024: Semiconductor technologies were easily accessible in the U.S.A. (1990-1999), and the Genesis team used those resources for cleanroom design and UPW system expansion. Image documentation was changing from film to digital during cleanroom construction and payload cleaning (1997-2001). Engineering design was done using computer aided design proprietary software, making more difficult the archiving of payload configuration and materials. Email of documents, tracked delivery service and virtual meeting capability greatly improved communication efficiency. Information sources – Pre-launch mission preparation: Examples of mission science, engineering and contamination control are collector purity testing, payload design/fabrication and ISO 4 cleanroom construction. Information on timing of these activities comes from facility readiness reviews, management reviews, shipping documents, procurement documents, test reports, travel documents, laboratory logs, Quality Assurance documents, dates on images, participant notebooks and emails. Information sources – Sample return re-entry and field recovery activities: Information comes from event timelines produced by Mid-Air Recovery team, Lockheed team lead notes and from chase video, JPL Quality Assurance. Information also comes from images and logbooks from UTTR cleanroom operations and from curatorial documents. Information sources – Resulting science and sample cleaning processes: Agendas from the annual gatherings of the science team initially trace testing for collector purity/cleanliness, and after sample recovery, include collector cleaning and cleanliness assessment. Post-recovery documents include curatorial orders and procedures, sample allocation documents and LPSC abstracts. Timeline Objectives: A simple spreadsheet timeline with headers DATE, EVENT, PEOPLE, COMMENT, INFORMATION SOURCE has been initiated and currently has over 90 entries. While this is not definitive historical research, it is a quick look at the evolution of Genesis curation with pointers to documents or people with information. Engineers for future missions may find useful points of comparison for development of facilities. References:[1] Genesis Mission Reference Document, (2011) JPL D-62382.[2] Niebur S. M., edited by Brown D. W. (2023) NASA’s Discovery Program: The First 20 Years of Competitive Planetary Exploration, NASA-SP-2023-4238.[3] Genesis Mishap Investigation Board Report, Vol. 1 (July 2005).

solar wind↗

Closed-loop control of active nematic flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware/software/wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Nishiyama, Katsu [Brandeis Univ., Waltham, MA (Uni↗

Development of an electrostatic positioner for space material processing

This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.

Rhim, W. K.↗

Detection of Head and Neck Cancer Based on Longitudinal Changes in Serum Protein Abundance

Head and Neck Squamous Cell Carcinoma (HNSCC) is significantly represented in the military population with substantial impact on military operations. Two-thirds of new HNSCC cases are first diagnosed at advanced stage III or IV with lymph node metastases. Thus, there is an urgent need of biomarkers for early detection and risk stratification. Archived serum samples from the Department of Defense Serum Repository provide a unique resource for longitudinal studies of HNSCC in the military and the identification of early detection biomarkers. Methods: We identified 175 patients diagnosed with HNSCC with 175 matched healthy controls and retrieved a total of 978 serum samples drawn at the time of diagnosis, 2 and 4 years prior to diagnosis, and 2 years after diagnosis. Following immunoaffinity depletion, serum samples were analyzed by targeted proteomics assays for multiplexed quantification of a panel of 146 candidate protein biomarkers from the curated literature. Results: We derived a 13-protein signature that distinguishes case versus controls based on longitudinal changes in serum protein concentration. The abundances of each of the 13 proteins remain constant over time in control subjects. The area under the curve for the derived random forest classifier was 0.90. Conclusions: This 13-protein classifier is highly promising for detection of HNSCC prior to overt symptoms. Impact: Use of longitudinal samples has significant potential to identify biomarkers for detection and risk stratification.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Improved Platform for the Benchtop Study of Complex Radiological Environments that Affect Fallout Formation: DHS Feasbility Study (Final Report)

Fallout analysis is a crucial field of study as it provides insight into the structural interactions that occur between radiological components and their surroundings following a nuclear event. Due to the complexity of actual fallout samples, setups like the plasma flow reactor (PFR) at LLNL have been developed to synthesize fallout in a controlled environment. While the PFR allows for control of parameters such as initial temperature, cooling rate, and concentration of radiological species, controlling the concentration of water has remained a challenge as samples are introduced into the setup via aqueous solution. To that end, our goal with this project was to develop methodologies to (1) monitor and (2) control the presence of water in the PFR. We found that a commercially available FTIR and MCT detector was sufficient to monitor the presence of both condensed and vapor-phase water, while a desolvating nebulizer could be used to control the amount of water injected into the system. In total, the results of this feasibility study have expanded the ability of the flow reactor to investigate key sensitivities that influence fallout formation.