Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

System, apparatus, and method for determining elemental composition using 4D STEM

The present disclosure relates to transmission electron microscopy for evaluation of biological matter. According to an embodiment, the present disclosure further relates to an apparatus for determining the structure and/or elemental composition of a sample using 4D STEM, comprising a direct bombardment detector operating with global shutter readout, processing circuitry configured to acquire images of bright-field disks using either a contiguous array or non-contiguous array of detector pixel elements, correct distortions in the images, align each image of the images based on a centroid of the bright-field disk, calculate a radial profile of the images, normalize the radial profiles by a scaling factor, calculate the rotationally-averaged edge profile of the bright-field disk, and determine elemental composition within the specimen based on the characteristics of the edge profile of the bright-field disk corresponding to each specimen location.

Bammes, Benjamin↗

Collimation and tagging instrumentation for the GlueX Photon Beamline

A new high energy polarized photon source is being constructed for the GlueX experiment at Jefferson Lab. Linear polarization is obtained using coherent bremsstrahlung from an oriented diamond radiator. By collimating the photon beam to a fraction of the characteristic bremsstrahlung angle $m_e/E_0$, linear polarization of 40\% is obtained at a photon energy of 9~GeV, for an incident electron beam of 12~GeV. Active stabilization of the photon beam spot on the collimator face is required in order to establish and maintain the alignment of the beam on the collimator axis with the required degree of accuracy. A photon beam centroid monitor has been developed for this purpose, based on the design of an electron beam halo detector that was invented for use at SLAC 30 years ago. Beam tests of this device in Hall B at 6 GeV show that it has the required bandwidth and sensitivity to be used in an active feedback loop in the electron beam steering controls. Such a feedback circuit is capable of locking the Hall D photon beam on the Hall D collimator with the required accuracy for GlueX at frequencies up to 1~kHz, over a wide range in beam current.

Jones, Richard↗

Acoustic emission and guided ultrasonic waves for detection and continuous monitoring of cracks in light water reactor components

Acoustic emission (AE) and guided ultrasonic waves (GUW) are considered for continuous monitoring and detection of cracks in Light Water Reactor (LWR) components. In this effort, both techniques are applied to the detection and monitoring of fatigue crack growth in a full scale pipe component. AE results indicated crack initiation and rapid growth in the pipe, and significant GUW responses were observed in response to the growth of the fatigue crack. After initiation, the crack growth was detectable with AE for approximately 20,000 cycles. Signals associated with initiation and rapid growth were distinguished based on total rate of activity and differences observed in the centroid frequency of hits. An intermediate stage between initiation and rapid growth was associated with significant energy emissions, though few hits. GUW exhibit a nearly monotonic trend with crack length with an exception of measurements obtained at crack lengths of 41 mm and 46 mm. Coupling variability and shadowing by the electro-discharge machining (EDM) starter notch set the lower limit of detectability. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aromatic-Aromatic Interactions in Biological System: Structure Activity Relationships

While, intramolecular hydrogen bonds have attracted the greatest attention in studies of peptide conformations, the recognition that several other weakly polar interactions may be important determinants of folded structure has been growing. Burley and Petsko provided a comprehensive overview of the importance of weakly polar interactions, in shaping protein structures. The interactions between aromatic rings, which are spatially approximate, have attracted special attention. A survey of the proximal aromatic residue pairs in proteins, allowed Burley and Petsko to suggest that, “phenyl ring centroids are separated by a preferential distance of between 4.5 and 7 Å, and dihedral angles approximately 90° are most common”.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-assisted decision analyses related to a chromium plume at Los Alamos national Laboratory - 15449

?he chromium plume at Los Alamos National Laboratory is a complex contaminant-remediation site with spatial extent of several square kilometers. It is located in a regional aquifer near water-supply wells and other points of compliance. The plume originated on the ground surface and the contaminant migrated along complex pathways through a thick vadose zone (∼300 m) that includes intermediate lateral zones of saturation and vertical preferential flow paths. Here we discuss the development of a modeling computational framework for the site. The framework work incorporates data assimilation and model-results analysis tools including decision support techniques. The decision tools are demonstrated using synthetic problems consistent with the interpretation of existing site data and site modeling results. The analyses aim at robust and efficient environmental management of the plume and explore a series of alternative remedial options. The remedial options include natural attenuation (NA), enhanced attenuation (EA), contaminant source removal (in the vadose zone), contaminant extraction (in the regional aquifer at the plume centroid and peripheries), biogeochemical remediation (injection of fluids stimulating growth of organisms in the aquifer impacting chromium concentrations), as wells as hydraulic controls on the groundwater flow and transport in the vadose zone and the regional aquifer. The applied model analyses and decision-support algorithms are implemented in code MADS (Model Analyses for Decision Support; http://mads.lanl.gov). MADS is an open-source framework for model-based decision support employing system and physics simulation models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Seismic Response of Scaled Storage Containments under Identical Loading Conditions - 16318

Dry Storage Casks (DSCs) store spent nuclear fuel (SNF), usually at sites contiguous to nuclear power plants known as Independent Spent Fuel Storage Installation (ISFSI). DSCs have been considered as a temporary storage solution, and are usually licensed for 20 years, which can be extended up to an operating periods of 60 years. Recently, however, DSCs have been considered as a potential mid-term solution for hundreds of years. This consideration requires reevaluation of DSC performance under a larger seismic hazard. That leads to larger horizontal and vertical accelerations. This study is a part of a research project evaluating the seismic response of free-standing DSCs under long return period seismic events. This article assess whether the response of free-standing structures under seismic excitation is repeatable. For this purpose, experimental tests were conducted using a six degree-of-freedom (6DOF) shake table. During the experimental tests, several ground motions were repeated multiple times to obtain the dynamic response under identical loading conditions. Scaled casks of four aspect ratios (radius to centroidal height ratio, r/h{sub cg}) were studied: 0.39, 0.43, 0.55 and 0.62. The specimens studied are considered to be 1:2.5 and 1:3.5 scaled model of generic prototype casks. The experimental results show that a small change in initial conditions leads to change in the boundary condition of moving bodies and in combination with acceleration being applied at different frequencies contained within the applied ground motions may lead to a large variation in the response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Composite Spectrum of QSO Absorption Line Systems in DESI DR2

We present details regarding the construction of a composite spectrum of quasar (QSO) absorption line systems. In this composite spectrum we identify more than 70 absorption lines, and observe oxygen and hydrogen emission features at a higher signal-to-noise ratio than in any previous study. As the light from a distant quasar travels towards an observer, it may interact with the circumgalactic medium environment of an intervening galaxy, forming absorption lines. In order to maximize the signal of these absorption lines, we have selected a sample of 238,838 quasar spectra from the second data release of the Dark Energy Spectroscopic Instrument (DESI), each identified to have absorption lines resulting from such an interaction. By stacking these spectra in the restframe of the absorption, and calculating a median composite spectrum, we are able to isolate and enhance these absorption lines. We provide a full atlas of all detected absorption and emission lines as well as their fit centroids and equivalent width values. This atlas should aid in future studies investigating the compositions and physical conditions of these absorbers.

Napolitano, Lucas [Wyoming U.] (ORCID:000000025166↗

WAVEGUIDE COUPLER KICK TO BEAM BUNCH AND CURRENT DEPENDENCY ON SRF CAVITIES

JLAB SRF cavities employ waveguide type fundamental power couplers (FPC). The FPC design for the 7-cell upgrade cavities was optimized to minimize the dipole field kick. For continuous wave (CW) operation, the forwarding RF power will be at different magnitude to drive the different beam current and cavity gradient. This introduces some deviation from optimized FPC field for varying beam loading. This article analyzes the beam behavior both in centroid kick and head-tail kick under different beam loading conditions.

43 PARTICLE ACCELERATORS↗

PROGRESS IN BEAM FOCUSING AND COMPRESSION FOR WARM-DENSE MATTER EXPERIMENTS

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using spacecharge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has beendemonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlledramps and forced neutralization. Using an injected 30-mA K+ ion beam with initialkinetic energy 0.3 MeV, axial compression leading to ~;;50-fold current amplification andsimultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to our Neutralized Drift Compression Experiment and associated beam diagnostics that are under development to reach the necessary higher beam intensities, including: (1) greater axial compression via a longer velocity ramp using a new bunching module with approximately twice the available voltseconds; (2) improved centroid control via beam steering dipoles to mitigate aberrations in the bunching module; (3) time-dependent focusing elements to correct considerable chromatic aberrations; and (4) plasma injection improvements to establish a plasma density always greater than the beam density, expected to be>1013 cm-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal Bunch Position Control for the Super-B Accelerator

The use of normal conducting cavities and an ion-clearing gap will cause a significant RF accelerating voltage gap transient and longitudinal phase shift of the individual bunches along the bunch train in both rings of the SuperB accelerator. Small relative centroid position shifts between bunches of the colliding beams will have a large adverse impact on the luminosity due to the small {beta}*{sub y} at the interaction point (IP). We investigate the possibility of minimizing the relative longitudinal position shift between bunches by reducing the gap transient in each ring and matching the longitudinal bunch positions of the two rings at the IP using feedback/feedforward techniques in the LLRF. The analysis is conducted assuming maximum use of the klystron power installed in the system.

43 PARTICLE ACCELERATORS↗

An EXAFS Spectroscopic, Large-Angle X-Ray Scattering, And Crystallographic Study of Hexahydrated, Dimethyl Sulfoxide And Pyridine 1-Oxide Hexasolvated Mercury(II) Ions

The structure of the solvated mercury(II) ion in water and dimethyl sulfoxide has been studied by means of large-angle X-ray scattering (LAXS) and extended X-ray absorption fine structure (EXAFS) techniques. The distribution of the Hg-O distances is unusually wide and asymmetric in both solvents. In aqueous solution, hexahydrated [Hg(OH{sub 2}){sub 6}]{sup 2+} ions in a distorted octahedral configuration, with the centroid of the HgO distance at 2.38(1) {angstrom}, are surrounded by a diffuse second hydration sphere with HgOII distances of 4.20(2) {angstrom}. In dimethyl sulfoxide, the six HgO and HgS distances of the hexasolvated [Hg{l_brace}OS(CH{sub 3}){sub 2}{r_brace}{sub 6}]{sup 2+} complex are centered around 2.38(1) and 3.45(2) {angstrom}, respectively. The crystal structure of hexakis(pyridine 1-oxide)mercury(II) perchlorate has been redetermined. The space group R implies six equal HgO distances of 2.3416(7) {angstrom} for the [Hg(ONC{sub 5}H{sub 5}){sub 6}]{sup 2+} complex at 100 K. However, EXAFS studies of this compound, and of the solids hexaaquamercury(II) perchlorate and hexakis(dimethyl sulfoxide)mercury(II) trifluoromethanesulfonate, also with six equidistant HgO bonds according to crystallographic results, reveal in all cases strongly asymmetric HgO distance distributions. Vibronic coupling of valence states in a so-called pseudo-Jahn-Teller effect probably induces the distorted configurations.

36 MATERIALS SCIENCE↗

The MACHO Project HST Follow-Up: The Large Magellanic Cloud Microlensing Source Stars

We present Hubble Space Telescope (HST) WFPC2 photometry of 13 microlensed source stars from the 5.7 year Large Magellanic Cloud (LMC) survey conducted by the MACHO Project. The microlensing source stars are identified by deriving accurate centroids in the ground-based MACHO images using difference image analysis (DIA) and then transforming the DIA coordinates to the HST frame. None of these sources is coincident with a background galaxy, which rules out the possibility that the MACHO LMC microlensing sample is contaminated with misidentified supernovae or AGN in galaxies behind the LMC. This supports the conclusion that the MACHO LMC microlensing sample has only a small amount of contamination due to non-microlensing forms of variability. We compare the WFPC2 source star magnitudes with the lensed flux predictions derived from microlensing fits to the light curve data. In most cases the source star brightness is accurately predicted. Finally, we develop a statistic which constrains the location of the Large Magellanic Cloud (LMC) microlensing source stars with respect to the distributions of stars and dust in the LMC and compare this to the predictions of various models of LMC microlensing. This test excludes at {approx}> 90% confidence level models where more than 80% of the source stars lie behind the LMC. Exotic models that attempt to explain the excess LMC microlensing optical depth seen by MACHO with a population of background sources are disfavored or excluded by this test. Models in which most of the lenses reside in a halo or spheroid distribution associated with either the Milky Way or the LMC are consistent which these data, but LMC halo or spheroid models are favored by the combined MACHO and EROS microlensing results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PROGRESS TOWARDS NEXT GENERATION, WAVEFORM BASED THREE-DIMENSIONAL MODELS AND METRICS TO IMPROVE NUCLEAR EXPLOSION MONITORING IN THE MIDDLE EAST

Efforts to update current wave speed models of the Middle East require a thoroughly tested database of sources and recordings. Recordings of seismic waves traversing the region from Tibet to the Red Sea will be the principal metric in guiding improvements to the current wave speed model. Precise characterizations of the earthquakes, specifically depths and faulting mechanisms, are essential to avoid mapping source errors into the refined wave speed model. Errors associated with the source are manifested in amplitude and phase changes. Source depths and paths near nodal planes are particularly error prone as small changes may severely affect the resulting wavefield. Once sources are quantified, regions requiring refinement will be highlighted using adjoint tomography methods based on spectral element simulations [Komatitsch and Tromp (1999)]. An initial database of 250 regional Middle Eastern events from 1990-2007, was inverted for depth and focal mechanism using teleseismic arrivals [Kikuchi and Kanamori (1982)] and regional surface and body waves [Zhao and Helmberger (1994)]. From this initial database, we reinterpreted a large, well recorded subset of 201 events through a direct comparison between data and synthetics based upon a centroid moment tensor inversion [Liu et al. (2004)]. Evaluation was done using both a 1D reference model [Dziewonski and Anderson (1981)] at periods greater than 80 seconds and a 3D model [Kustowski et al. (2008)] at periods of 25 seconds and longer. The final source reinterpretations will be within the 3D model, as this is the initial starting point for the adjoint tomography. Transitioning from a 1D to 3D wave speed model shows dramatic improvements when comparisons are done at shorter periods, (25 s). Synthetics from the 1D model were created through mode summations while those from the 3D simulations were created using the spectral element method. To further assess errors in source depth and focal mechanism, comparisons between the three methods were made. These comparisons help to identify problematic stations and sources which may bias the final solution. Estimates of standard errors were generated for each event's source depth and focal mechanism to identify poorly constrained events. A final, well characterized set of sources and stations will be then used to iteratively improve the wave speed model of the Middle East. After a few iterations during the adjoint inversion process, the sources will be reexamined and relocated to further reduce mapping of source errors into structural features. Finally, efforts continue in developing the infrastructure required to 'quickly' generate event kernels at the n-th iteration and invert for a new, (n+1)-th, wave speed model of the Middle East. While development of the infrastructure proceeds, initial tests using a limited number of events shows the 3D model, while showing vast improvement compared to the 1D model, still requires substantial modifications. Employing our new, full source set and iterating the adjoint inversions at successively shorter periods will lead to significant changes and refined wave speed structures of the Middle East.

58 GEOSCIENCES↗

Developing The Physics Desing for NDCS-II, A Unique Pulse-Compressing Ion Accelerator

The Heavy Ion Fusion Science Virtual National Laboratory (a collaboration of LBNL, LLNL, and PPPL) is using intense ion beams to heat thin foils to the 'warm dense matter' regime at {approx}< 1 eV, and is developing capabilities for studying target physics relevant to ion-driven inertial fusion energy. The need for rapid target heating led to the development of plasma-neutralized pulse compression, with current amplification factors exceeding 50 now routine on the Neutralized Drift Compression Experiment (NDCX). Construction of an improved platform, NDCX-II, has begun at LBNL with planned completion in 2012. Using refurbished induction cells from the Advanced Test Accelerator at LLNL, NDCX-II will compress a {approx}500 ns pulse of Li{sup +} ions to {approx} 1 ns while accelerating it to 3-4 MeV over {approx} 15 m. Strong space charge forces are incorporated into the machine design at a fundamental level. We are using analysis, an interactive 1D PIC code (ASP) with optimizing capabilities and centroid tracking, and multi-dimensional Warpcode PIC simulations, to develop the NDCX-II accelerator. This paper describes the computational models employed, and the resulting physics design for the accelerator.

43 PARTICLE ACCELERATORS↗

DEVELOPING THE PHYSICS DESIGN FOR NDCX-II, A UNIQUE PULSE-COMPRESSING ION ACCELERATOR

The Heavy Ion Fusion Science Virtual National Laboratory(a collaboration of LBNL, LLNL, and PPPL) is using intense ion beams to heat thin foils to the"warm dense matter" regime at<~;; 1 eV, and is developing capabilities for studying target physics relevant to ion-driven inertial fusion energy. The need for rapid target heating led to the development of plasma-neutralized pulse compression, with current amplification factors exceeding 50 now routine on the Neutralized Drift Compression Experiment (NDCX). Construction of an improved platform, NDCX-II, has begun at LBNL with planned completion in 2012. Using refurbished induction cells from the Advanced Test Accelerator at LLNL, NDCX-II will compress a ~;;500 ns pulse of Li+ ions to ~;;1 ns while accelerating it to 3-4 MeV over ~;;15 m. Strong space charge forces are incorporated into the machine design at a fundamental level. We are using analysis, an interactive 1D PIC code (ASP) with optimizing capabilities and centroid tracking, and multi-dimensional Warpcode PIC simulations, to develop the NDCX-II accelerator. This paper describes the computational models employed, and the resulting physics design for the accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Telescope Guiding with a HyViSI H2RG Used in Guide Mode

We report on long exposure results obtained with a Teledyne HyViSI H2RG detector operating in guide mode. The sensor simultaneously obtained nearly seeing-limited data while also guiding the Kitt Peak 2.1 m telescope. Results from unguided and guided operation are presented and used to place lower limits on flux/fluence values for accurate centroid measurements. We also report on significant noise reduction obtained in recent laboratory measurements that should further improve guiding capability with higher magnitude stars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blades and Towers Modal Analysis Code (BModes): Verification of Blade Modal Analysis Capability

BModes is a finite-element code we developed to provide coupled modes for flexible blades, rotating or non-rotating, and for towers, onshore or offshore (supported either on floating platforms or on monopile foundations). Both the blade and the tower allow a tip attachment, which is modeled as a rigid body with mass, six moments of inertia, and a mass centroid that may be offset from the blade or tower axis. Examples of tip attachments are aerodynamic brakes for blades and nacelle-rotor subassemblies for towers. Allowable supports for the tower include tension wires, floating platforms, and shallow-water monopiles with elastic foundation. Coupled modes (implying coupling of flap, lag, axial, and torsion motions) have several applications. Examples are: modeling of major flexible components for modal-based aeroelastic codes such as FAST, validation of turbine models using experimental data, modal-based fatigue analysis, and understanding of aeroelastic-stability behavior of turbines. This paper presents verification of the blade modal analysis capability of BModes. Verification begins with simple uniform beams, rotating and non-rotating, and progresses to realistic blades. BModes-computed modes for all models are compared with analytical modes, if possible to obtain, and with modes generated by RCAS. All results, presented in terms of frequencies and mode shapes, show excellent agreement.

17 WIND ENERGY↗