Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Overview of SIM external calibration

Like all astrometric instruments, the Space Interferometry Mission (SIM) suffers from field-dependent errors requiring calibration. Diffraction effects in the delay line, polarization rotations on comer cubes, and beam walk across imperfect optics, all contribute to field-distortion that is significantly larger than is acceptable. The bulk of the systematic error is linear across the field - that is, it results in a magnification error. We show that the linear terms are inconsequential to the performance of SIM because they are inseparable from baseline length and orientation errors. One approach to calibrating the higher-order terms is to perform external' calibration; that is, SIM periodically makes differential measurements of a field of bright stars whose positions are not precisely known. We describe the requirements and constraints on the external calibration process and lay the groundwork for a specific procedure detailed in accompanying papers.

Space↗

(abstract) The 1994 Laboratory Calibration Of TIMS

This summary describes the spatial, spectral, and radiometric calibration of TIMS performed at the JPL Thermal Infrared Calibration Facility (TIRCAL) between May and August 1994. The 1994 calibration of TIMS was the first to make use of the new EXABYTE (8mm helical-scan tape) recording system. With the new recorder, the TIMS data tapes may be read directly on any computer system that has an EXABYTE tape drive. We analyzed the calibration data sets using image processing procedures written in IDL (Research Systems, Inc., Boulder, CO 80303).

TIMS↗

Assessment of VIIRS on-orbit polarization sensitivity and its impact on CLARREO pathfinder inter-calibration

The primary objective of the CLARREO Pathfinder (CPF) mission is to demonstrate essential measurement technologies to enable highly accurate decadal change observations traceable on-orbit to SI standards. Another important objective of the CPF is to demonstrate inter-calibration with the VIIRS sensor and to show that such high-accuracy reference inter-calibration is achievable. To satisfy this requirement, it is important to understand and quantify uncertainties in VIIRS sensor measurements. Based on prelaunch test results, the reflective solar bands of both SNPP and NOAA-20 VIIRS have exhibited polarization sensitivities in the shortest wavelength bands, with an unexpectedly larger sensitivity observed for NOAA-20 VIIRS, particularly in bands M1 to M4. In this study, we use VIIRS Level-1B reflectance data collected over the Pseudo-Invariant Calibration Sites over North African desert region to examine the polarization associated uncertainty for these four bands. Impact due to BRDF on the reflectance data is considered by comparing baseline results obtained from the same viewing and solar zenith angles under relatively low polarization sensitivity. Impact due to detector relative difference in polarization sensitivity is examined by normalizing reflectances by the value of the middle detector. Results of this study provide useful information on VIIRS uncertainty contribution due to polarization when conducting CPF and VIIRS inter-calibration.

VIIRS↗

Evaluation of NOAA-20 VIIRS reflective solar bands calibration performance using vicarious approaches

The newly launched polar-orbiting NOAA-20 satellite is the follow-on mission to the SNPP (Suomi National Polar-orbiting Partnership) satellite. Both satellites are in an afternoon orbit with a close equatorial cross time. The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor onboard NOAA-20 and SNPP. The two VIIRS sensors are within the same engineering design with nearly identical spectral ranges. Its on-board calibration components include a solar diffuser and a solar diffuser stability monitor for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view as background reference. This study evaluates calibration performance of the NOAA-20 VIIRS RSB using the first internally released L1B data product by NASA Land SIPS, which has consistent calibration coefficient look up tables (LUT) throughout the entire mission. Several independent vicarious approaches are used to examine the stability and consistence of reflectance. The first approach is based on a double difference method by comparison with SNPP VIIRS using observations from simultaneous nadir overpasses (SNO) with Aqua MODIS. The second is based on the reflectance trends from 16-day repeatable orbits obtained over the widely used Liby-4 desert site so each data point has the nearly same viewing angles relative to the site. The third approach is to use the frequent overpasses over the Dome C snow site. Results of this study provide NOAA-20 VIIRS post-launch calibration stability performance and radiometric agreement with SNPP for the first 18 months of mission.

VIIRS↗

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Model Calibration for Cancer Risk Projections According to Uncertain Data

This paper presents forward and inverse formulations for the calibration of computational models according to uncertain data. Uncertainty in the data might be caused by a poor metrology system, measurement noise, missing or uncontrollable input variables, or by the inability to directly measure the inputs and/or outputs of interest. The forward approach performs the calibration in the space of the model’s output thereby requiring repeated model simulations. Conversely, the inverse approach leverages an ensemble of solutions to an inverse problem in order to perform the calibration in the space of the model’s parameters. As such, the computational demands of the inverse approach are considerably lower. These strategies are applied to the calibration of a radiation model that in-forms cancer risk projections for future deep space missions.

uncertainty quantification↗

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS↗

On-Orbit Calibration and Performance of NOAA-20 VIIRS Reflective Solar Bands

The NOAA-20 (N20) satellite was launched on November 18, 2017 carrying the second Visible Infrared Imaging Radiometer Suite (VIIRS) instrument. Immediately following the launch, the VIIRS passed a series of intensive calibration and validation tests, after which regular calibration and operation activities have continued successfully for more than three years. The production of NASA Collection 2 Level 1B (C2 L1B) for N20 VIIRS began in summer 2019. In this article, we evaluate the early mission performance of the N20 VIIRS reflective solar bands (RSB) covering the first three full years of operation. The calibrated RSB gains are calculated primarily from the onboard solar diffuser (SD) and used in generating the C2 L1B reflectance and radiance products. We also show the on-orbit performance of the instrument noise, signal-to-noise ratio (SNR), and a reflectance uncertainty assessment. Comparisons are made to the first three years of operation of the first VIIRS instrument, aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. We evaluate the long-term stability of the calibrated N20 RSB reflectance product by looking at the long-term trends of lunar observations and data from the pseudo-invariant Libya 4 desert site. The N20 RSB have had excellent early mission performance, with changes in the gain of less than 0.5% in the first three years across all detectors, stable L1B reflectance, and very stable values of detector SNR and reflectance uncertainty.

calibration↗

The MODIS TEBs Calibration and Look-up Table Delivery Process for Collections 6 and 6.1

MODIS is a cross-track, whisk-broom scanning imaging radiometer with a double-sided scan mirror that collects data in 36 spectral bands. Sixteen of the 36 MODIS spectral bands are Thermal Emissive Bands (TEBs) whose spectral wavelengths range from 3.5 μm to 14.4 μm. The TEB detectors are calibrated on a scan-by-scan basis using a quadratic calibration algorithm by observing both the MODIS on-board blackbody (BB) and a background space view reference. Blackbody warm-up/cool-down (WUCD) events are performed quarterly to track on-orbit changes associated with the TEB detectors' non-linearity. Following each WUCD, the calibration coefficients in the quadratic algorithm, and their associated contributions to the total uncertainty, are updated and delivered through separate look-up tables (LUTs) when all update criteria are met. Afterwards, the LUTs are incorporated into the Level 1B (L1B) product. Since the Terra MODIS mission began, a steady increase in electronic cross-talk has been observed for TEBs 27{30. Starting from Collection 6.1, an algorithm has been applied using correction coefficients derived from regularly-scheduled lunar observations, with the correction LUT update dependent on its impact on the current L1B product. The MODIS Characterization Support Team (MCST) has established a comprehensive set of procedures to assure timely and accurate LUT updates, and maintain the quality and accuracy of the L1B and science products. This paper provides an overview of the current calibration and LUT delivery process for the MODIS TEBs in Collections 6 and 6.1.

MODIS↗

Improvements in the Calibration of the NOAA-20 VIIRS Day-Night Band Low Gain Stage Using a Solar Diffuser

We aim to introduce and demonstrate several improvements that are applied to the on-orbit solar diffuser (SD) calibration of the day-night band (DNB) low gain stage (LGS) of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the NOAA-20 satellite. The most important improvement is the expansion of the angular range, referred to “sweet spot”, from 4° to 7.8° in order to increase the number of fully-illuminated scans considered for the SD calculation. The increase in scan number enables the completion of on-orbit calibration using the SD within one orbit, compared with the multiple orbits approach, which is required in the current standard approach applied in operational DNB LGS calibration coefficients look-up tables (LUTs) updates. The NOAA-20 DNB LGS calibration coefficients have been derived with the new methodology and the results show a more stable, smoother, and less noisy trend when compared with the current standard approach. The results also demonstrate that the NOAA-20 VIIRS DNB overall on-orbit performance has been very stable.

NOAA-20↗

Assessment of MODIS and VIIRS Calibration Consistency for Reflective Solar Bands Using Vicarious Approaches

The Moderate-Resolution Imaging Spectroradiometer (MODIS) is the key instrument of the NASA’s Earth Observing System (EOS) Terra and Aqua missions, launched in December 1999 and May 2002, respectively. The Visible Infrared Imaging Radiometer Suite (VIIRS) expands the MODIS legacy, launched onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite in October 2011 and NOAA20 satellite in November 2017, respectively. The MODIS and VIIRS sensors have a similar design with spectrally matched reflective solar spectral bands (RSB). Their on-board calibration components include a solar diffuser and a solar diffuser stability monitor for RSB, a V-grooved blackbody for the thermal emissive bands (TEB), and a space view as a background reference. This study evaluates the calibration consistency of the Terra and Aqua MODIS RSB based on the current Collection 6.1 L1B data products generated by the NASA MODAPS, which have used consistent calibration coefficient look up tables (LUT) for the entire data-record. In the case of SNPP and NOAA20 VIIRS, the latest L1B data produced by NASA Land SIPS are used. Several independent vicarious approaches are used to examine the stability and consistency of the at-sensor reflectance among MODIS and VIIRS instruments. Vicarious approaches include observations from simultaneous nadir overpasses (SNO), the Libya-4 desert and Dome C snow sites, as well as deep convective clouds (DCC). Impact of existing band spectral difference on the reflectance is corrected using hyperspectral observations provided by Europe Space Agency’s SCIAMACHY sensor. Results of this study provide comprehensive assessments of calibration performance, radiometric agreement and associated uncertainties.

MODIS↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

Efficient Calibration of Expensive Computational Models

Accounting for uncertainty when calibrating expensive computational models is a common challenge faced by scientists and engineers. Often Bayesian techniques are adopted to estimate a probability density function over the model parameters given noisy empirical data. The methods used to perform this type of probabilistic calibration are computationally prohibitive in that they require a large number of evaluations of the expensive model. In these cases, surrogate modeling -- that is, using a fast-to-evaluate, lower fidelity stand-in for the original computational model -- may be the only option to alleviate this computational burden. However, the upfront cost of generating training data to build a surrogate model can itself be expensive. As such, it is important to be judicious when selecting training points at which the full-fidelity model is evaluated. Here, an active learning approach is proposed that enables efficient selection of training points using approximate samples of the calibrated parameter probability density function. In this way, the training points can be concentrated in regions where the calibration algorithm requires high model accuracy.

active learning↗

An Inverse Chance-constrained Approach to the Calibration of Robust Models

This paper proposes a strategy to calibrate computational models according to uncertain input-output data. To this end, uncertainty in the data is first quantified by creating adversarial data sets. Samples drawn from such sets are then mapped from the input-output space to the parameter space using an inverse mapping. This mapping minimizes the collective output spread of an ensemble of point predictions while satisfying a set of individual data-matching requirements. The distribution of the resulting parameter points, which often exhibits strong parameter dependencies, is then modeled using sliced-normals. The chance-constrained formulation used to learn this distribution enables the analyst to trade-off a greater likelihood for most of the data against a lower likelihood for some of the data thereby relaxing the conservatism of the calibrated model. This formulation not only neglects the worst-performing quantiles of each adversarial distribution but also eliminates the potentially serious effects that outliers might have on the resulting model. This calibration approach not only has a considerably lower computational cost than the standard forward approach but it also allows for the identification of suitable distribution classes, which in turn yield better calibrated models.

Calibration↗

Using Scattered Light From Nadir Port to Aid the Terra and Aqua MODIS Reflective Solar Band Calibration

The MODIS instruments on the Terra and Aqua spacecraft employ a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system to calibrate their reflective solar bands (RSBs), covering a spectral range from 0.4 to 2.1 µm. The UV exposure of the SD, from its sun-view port as well as the scattered light (sunlight reflected from top-of-atmosphere), has led to a wavelength dependent degradation of the SD, with larger degradation observed at shorter wavelengths. The scatter off the diffuser onto the scan mirror is in the forward direction, whereas the scatter off the diffuser onto the SDSM fold mirror is in the backward direction. Since the outgoing angles (viewed by MODIS detectors) are the same as the scheduled SD calibration, the gain derived from scattering light facilitates monitoring the dependence of the SD’s degradation on incident angles. In this paper, we present a method that uses multiple orbits over each mission to obtain a SD response to the nadir port illumination. The SD degradation estimated from the nadir port illumination is compared with the degradation derived from the sun-illuminated SD. As both Terra and Aqua spacecraft continue to drift from their nominal orbits, the SD calibration mechanism has been adapted to these drifts, especially in terms of characterizing the transmission screen function. This paper also presents the utility of this scattering light data to support the RSB calibration in the post-nominal orbit drift era of operations.

MODIS↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

Novel calibration system with sparse wires for CMB polarization receivers

B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗