Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMMERCIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Characterization of a Commercial Silicon Beta Cell

Silicon detectors are of interest for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) due to their enhanced energy resolution compared to plastic scintillators beta cells. Previous work developing a figure-of-merit (FOM) for comparison of beta cells suggests that the minimum detectable activity (MDA) could be reduced by a factor of two to three with the use of silicon detectors. Silicon beta cells have been developed by CEA (France) and Lares Ltd. (Russia), with the PIPSBox developed by CEA being commercially available from Canberra for approximately $35k, but there is still uncertainty about the reproducibility of the capabilities in the field. PNNL is developing a high-resolution beta-gamma detector system in the shallow underground laboratory, which will utilize and characterize the operation of the PIPSBox detector. Throughout this report, we examine the capabilities of the PIPSBox as developed by CEA. The lessons learned through the testing and use of the PIPSBox will allow PNNL to strategically develop a silicon detector optimized to better suit the communities needs in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Finding Legacy Wells in Residential and Commercial Areas

In 1919, the enthusiasm surrounding a short-lived gas play in Versailles Borough, Pennsylvania resulted in the drilling of many needless wells. The legacy of this activity exists today in the form of abandoned, unplugged gas wells that are a continuing source of fugitive methane in the midst of a residential and commercial area. Flammable concentrations of methane have been detected near building foundations, which have forced people from their homes and businesses until methane concentrations decreased. Despite mitigation efforts, methane problems persist and have caused some buildings to be permanently abandoned and demolished. This paper describes the use of magnetic and methane sensing methods by the National Energy Technology Laboratory (NETL) to locate abandoned gas wells in Versailles Borough where site access is limited and existing infrastructure can interfere. Here, wells are located between closely spaced houses and beneath buildings and parking lots. Wells are seldom visible, often because wellheads and internal casing strings have been removed, and external casing has been cut off below ground level. The magnetic survey of Versailles Borough identified 53 strong, monopole magnetic anomalies that are presumed to indicate the locations of steel-cased wells. This hypothesis was tested by excavating the location of one strong, monopole magnetic anomaly that was within an area of anomalous methane concentrations. The excavation uncovered an unplugged gas well that was within 0.2 m of the location of the maximum magnetic signal. Truck-mounted methane surveys of Versailles Borough detected numerous methane anomalies that were useful for narrowing search areas. Methane sources identified during truck-mounted surveys included strong methane sources such as sewers and methane mitigation vents. However, inconsistent wind direction and speed, especially between buildings, made locating weaker methane sources (such as leaking wells) difficult. Walking surveys with the methane detector mounted on a cart or wagon were more effective for detecting leaking wells because the instrument’s air inlet was near the ground where: 1) the methane concentration from subsurface sources (including wells) was a maximum, and 2) there was less displacement of methane anomalies from methane sources by air currents. The Versailles Borough survey found 15 methane anomalies that coincided with the location of well-type magnetic anomalies; the methane sources for these anomalies were assumed to be leaking wells. For abandoned well locations where the wellhead and all casing strings have been removed and there is no magnetic anomaly, leaking wellbores can sometimes be detected by methane surveys. Unlike magnetic anomalies, methane anomalies can be: 1) ephemeral, 2) significantly displaced from the well location, and 3) from non-well sources that cannot be discriminated without isotopic analysis. If methane surveys are used for well location, the air inlet to the instrument should be kept as close to the ground as possible to minimize the likelihood of detecting methane from distant, wind-blown sources.

54 ENVIRONMENTAL SCIENCES↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Work in Hybrid Radiation Transport Methods with Applications to Commercial Nuclear Power

This talk will begin with an overview of hybrid radiation transport methods followed by a discussion of the author’s work to advance current capabilities. The talk will then describe applications for these methods in commercial nuclear power reactor analyses and techniques for experimental validation. When discussing these analytical and experimental activities, the importance of technical standards such as those created and maintained by ASTM International will be demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Commercialization of an Advanced Gearless Midsize Wind Turbine

The objective of this project was the development and eventual commercialization of a Gearless Wind Turbine of rated power 450 kW. While the product was to be based on existing technology, a significant amount of new engineering effort was expected to be required to ensure maximum efficiency and realistic placement within the market. Expected benefits included positive impact on green job creation in over 15 states as well as strengthen the U.S. domestic capacity for turbine engineering.

17 WIND ENERGY↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Absorption Heat Pump Water Heater: Beta Prototype Evaluation

The Beta version of the Commercial Absorption Heat Pump (CAHP) water heater was evaluated in the environmental chambers at Oak Ridge National Laboratory. Ambient air conditions ranged from 17 to 75 oF and inlet water temperatures ranged from 100 to 120oF in order to capture trends in performance. The unit was operated under full fire (100%) and partial fire (55%). The unit was found to perform at 90% of the project goal at the design conditions of 47oF ambient and 100oF water temperatures. The trends across the full range of environmental conditions were as expected for ambient air temperatures above 32oF. Below this temperature and for the full fire condition, frost accumulated on the evaporator coil. In future work a defrost strategy will be enabled, the unit will be thoroughly cleaned of an oil contamination and the rectifier will be reconfigured in order to meet the design goals and have a field test unit ready in early 2017.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

India Commercial Buildings Data Framework: A Summary of Potential Use Cases

This report details a potential set of use cases for India’s Commercial Buildings Data Framework. The use cases are aimed at enabling data-driven, evidence-based policy making and at transforming the market for energy efficiency in the building sector by facilitating the adoption of (1) superior energy-efficient building design and operation and maintenance practices, and (2) better specification and procurement of end-use equipment and systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manufacturing Steps for Commercial Production of Nano-Structure Capacitors Final Report CRADA No. TC02159.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and TroyCap LLC, to develop manufacturing steps for commercial production of nano-structure capacitors. The technical objective of this project was to demonstrate high deposition rates of selected dielectric materials which are 2 to 5 times larger than typical using current technology.

25 ENERGY STORAGE↗

Solid-State Neutron Multiplicity Counting System Using Commercial Off-the-Shelf Semiconductor Detectors

This work iterates on the first demonstration of a solid-state neutron multiplicity counting system developed at Lawrence Livermore National Laboratory by using commercial off-the-shelf detectors. The system was demonstrated to determine the mass of a californium-252 neutron source within 20% error requiring only one-hour measurement time with 20 cm 2 of active detector area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commercially Scalable Process to Fabricate Porous Silicon

Navitas Advanced Solutions Group proposes a novel, commercially scalable approach to supply microporous silicon (μpSi) to lithium ion battery manufacturers. If successful, this project will result in a significant reduction in the cost and environmental impact of high capacity anodes that are needed to meet the EV Everywhere battery goals. Silicon nanocomposite materials have been identified as a viable anode technology for EV batteries. Presently, high capacity silicon-based anodes rely either on materials that are expensive (e. g., silane or nano-silicon powder) or on processes that are limited by low yield methods (e.g., chemical vapor deposition). Microporous silicon potentially avoids these limitations and is attracting increasing attention as a lower cost alternative for the manufacture of high capacity silicon-based anodes. Microporous silicon suitable for EV batteries is not currently available as a commodity material. Microporous silicon can be produced at lab scale through a metal catalyzed hydrofluoric acid etching process. However, this process is expensive and hazardous. Our proposed production route will facilitate the availability of μpSi to lithium ion battery producers and developers at a scale and cost able to support EV battery production. Under the Vehicle Technologies FOA AOI 4 seeks Advances in Existing and Next-Generation Battery Material Manufacturing to reduce the cost of EV batteries. The EV Everywhere initiative establishes a goal of $100/kWh system level cost for an EV battery. This cost target can be met with moderate risk through pairing silicon-based high capacity anodes with lithium metal-rich nickel manganese cobalt oxide 'LMR-NMC' cathodes. For this set of assumptions, the silicon anode active material cost would need to be <$25/kg. The Navitas µpSi powder manufacturing process will reach this target through a combination of low-cost commodity raw materials and reactants with scalable and low environmental impact processes. Processing will involve mechanical milling and thermal reduction operations that are in wide application at industrial scale. The goal of this program is to reach most or all of the MRL 6 criteria in a pilot scale demonstration for the manufacturing of porous silicon powder, while minimizing raw material added cost and limiting hazardous and environmental impact and using scalable industrial processing (i.e. mechanical milling, thermal reduction). The Navitas μpSi fabrication process represents a novel approach to reduce the cost of silicon anode material manufacturing. This process has been shown to be more efficient (higher yield) and economical on scaling up than conventional metal-assisted etching. The process significantly reduces the cost on $/mAh basis versus existing anode materials. The μpSi powders can be modified to form nanocomposite structures through blending with graphite or coating with carbon or a metal oxide to decrease initial capacity loss (ICL) and improve cell cycle life, a key barrier to adoption of silicon anodes into EV batteries. The impact of this technology will be driven by the projected rate of EV adoption and market share. By reducing battery cost, the proposed technology will stimulate EV adoption rate. Assuming this technology enables capturing an additional 6% of the present PHEV + EV market the reduction in petroleum consumption would be 90,000 gallons of gasoline per day, or 1.6M barrels per year. The carbon emissions from a gallon of gasoline = 2.4 kg/gallon. Thus, if the proposed technology was incorporated into just 0.1% of all new vehicles produced and if all the electricity to power those electric-drive vehicles was produced from clean, renewable sources such as wind and solar, it would result in 15K metric tons/yr reduction of CO2 emissions.

25 ENERGY STORAGE↗

Comparison of Actual Costs to Integrate Commercial Buildings with the Grid

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This paper discusses the impact factors that contribute to the costs of automated DR systems, with a focus on OpenADR 1.0 and 2.0 systems. In addition, this report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. In summary, median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude greater or less than median. Costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total such costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research and Development of Zinc Air Fuel Cell To Achieve Commercialization Final Report CRADA No. TC-1544-98

The specific goal of this project was to advance the development of the zinc air fuel cell (ZAFC) towards commercial readiness in different mobile applications, including motor bikes, passenger cars, vans, buses and off-road vehicles (golf carts, factory equipment), and different stationary applications including generator sets, uninterruptible power systems and electric utility loading leveling and distributive power.

25 ENERGY STORAGE↗

Evaluation of Environmental Conditions on the Curing Of Commercial Fixative and Intumescent Coatings

Performance metrics for evaluating commercial fixatives are often not readily available for important parameters that must be considered per the facility safety basis and the facility Basis for Interim Operations (BIO). One such parameter is the behavior of such materials in varied, “non-ideal” conditions where ideal is defined as 75 °F, 40% RH. Coupled with the inherent flammable nature of the fixative materials that can act to propagate flame along surfaces that are otherwise fireproof (concrete, sheet metal), much is left unknown when considering the safety basis implications for introducing these materials into nuclear facilities. Through SRNL’s efforts, three (3) fixatives, one (1) decontamination gel, and six (6) intumescent coatings were examined for their responses to environmental conditions to determine whether these materials were impervious to non-nominal temperatures and humidities that may be found in nuclear facilities. Characteristics that were examined included set-to-touch time, dust free time, and adhesion testing of the fully cured compounds. Of these ten materials, three were two-part epoxy materials while the other seven consisted of only one constituent. The results show that the epoxies tested are unable to cure in sub-freezing temperatures, with the low temperatures inhibiting crosslinking to a very significant degree. These efforts show significant inhibiting of performance for non-nominal environmental conditions, something that must be addressed both in the decision process for a fixative material to apply and per the safety basis to ensure the accurate flammability and material at risk is calculated.

36 MATERIALS SCIENCE↗

Evaluation of Environmental Conditions on the Curing Of Commercial Fixative and Intumescent Coatings

Performance metrics for evaluating commercial fixatives are often not readily available for important parameters that must be considered per the facility safety basis and the facility Basis for Interim Operations (BIO). One such parameter is the behavior of such materials in varied, “non-ideal” conditions where ideal is defined as 75 °F, 40% RH. Coupled with the inherent flammable nature of the fixative materials that can act to propagate flame along surfaces that are otherwise fireproof (concrete, sheet metal), much is left unknown when considering the safety basis implications for introducing these materials into nuclear facilities. Through SRNL’s efforts, three (3) fixatives, one (1) decontamination gel, and six (6) intumescent coatings were examined for their responses to environmental conditions to determine whether these materials were impervious to non-nominal temperatures and humidities that may be found in nuclear facilities. Characteristics that were examined included set-to-touch time, dust free time, and adhesion testing of the fully cured compounds. Of these ten materials, three were two-part epoxy materials while the other seven consisted of only one constituent. The results show that the epoxies tested are unable to cure in sub-freezing temperatures, with the low temperatures inhibiting crosslinking to a very significant degree. These efforts show significant inhibiting of performance for non-nominal environmental conditions, something that must be addressed both in the decision process for a fixative material to apply and per the safety basis to ensure the accurate flammability and material at risk is calculated.

36 MATERIALS SCIENCE↗

SECARB Commercial Scale CO 2 Injection and Optimization of Storage Capacity in the Southeastern United States

The Commercial Scale Project is a US DOE/NETL funded initiative aimed at enhancing the knowledge-base and industry’s ability to geologically store vast quantities of anthropogenic carbon. In support of this goal, a large-scale, stacked reservoir geologic model was developed for Gulf Coast sediments centered on the Citronelle Dome in southwest Alabama, the site of the SECARB Phase III Anthropogenic Test. Characterization of regional geology to construct the model consists of an assessment of the entire stratigraphic continuum at Citronelle Dome, from surface to the depth of the Donovan oil-bearing formation. This project utilizes all available geologic data available, which includes: modern geophysical well logs from three new wells drilled for SECARB’s Anthropogenic Test; vintage logs from the Citronelle oilfield wells; porosity and permeability data from whole core and sidewall cores obtained from the injection and observation wells drilled for the Anthropogenic Test; core data obtained from the SECARB Phase II saline aquifer injection test; regional core data for relevant formations from the Geological Survey of Alabama archives. Cross sections, isopach maps, and structure maps were developed to validate the geometry and architecture of the Citronelle Dome for building the model, and assuring that no major structural defects exist in the area. A synthetic neural network approach was used to predict porosity using the available SP and resistivity log data for the storage reservoir formations. These data are validated and applied to extrapolate porosity data over the study area wells, and to interpolate permeability amongst these data points. Geostatistical assessments were conducted over the study area. In addition to geologic characterization of the region, a suite of core analyses was conducted to construct a depositional model and constrain caprock integrity. Petrographic assessment of core was conducted by OSU and analyzed to build a depositional framework for the region and provide modern day analogues. Stability of the caprock over several test parameters was conducted by UAB to yield comprehensive measurements on long term stability of caprocks. The detailed geologic model of the full earth volume from surface thru the Donovan oil reservoir is incorporated into a state-of-the-art reservoir simulation conducted by the University of Alabama at Birmingham (UAB) to explore optimization of CO 2 injection and storage under different characterizations of reservoir flow properties. The application of a scaled up geologic modeling and reservoir simulation provides a proof of concept for the large scale volumetric modeling of CO 2 injection and storage the subsurface.

58 GEOSCIENCES↗

Commercial Midstream Energy Efficiency Incentive Programs: Guidelines for Future Program Design, Implementation, and Evaluation

Many electric utilities operate energy efficiency incentive programs that encourage increased dissemination and use of energy-efficient (EE) products in their service territories. The programs can be segmented into three broad categories—downstream incentive programs target product end users, midstream programs target product distributors, and upstream programs target product manufacturers. Traditional downstream programs have had difficulty engaging Small Business/Small Portfolio (SBSP) audiences, and an opportunity exists to expand Commercial Midstream Incentive Programs (CMIPs) to reach this market segment instead.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗