Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical Research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Enabling a Voice Management System for Space Applications, Design and Software Development

Sustainable missions, beyond low Earth orbit, will require autonomous capabilities in order to achieve NASA’s Artemis program objectives. Correspondingly, the crew must have a means to efficiently interact with these autonomous systems; this can be facilitated via voice and speech communications. Voice-based controls enable the user to access autonomous systems hands-free/eyes-free, allowing the user to better focus on critical tasks. The goal of this project was to explore the knowledge and technology needed to successfully design effective voice interfaces for autonomous systems. The main objective was to understand how a crew member, through voice interaction, could most efficiently and intuitively communicate with a notional autonomous vehicle system manager. This project leveraged prior research conducted by the University of Michigan’s Bioastronautics and Life Support System (BLiSS) team as part of a NASA Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2020 Academic Innovation Challenge. The X-Hab 2020 work from the BliSS Team resulted in an intuitive graphical user interface/user experience that was built on an Internet of Things (IOT) platform. The Voice User Interface (VUI) design for the M2M X-Hab 2021 project leveraged this technology and incorporated a voice-based assistant and NASA’s Platform for Autonomous Systems (NPAS) software. This required technologies to convert voice to text, conduct semantic interpretations, and convert responses from the autonomous system to text and to speech; additionally, the background noise environment of spacecraft was assessed, and a relatable personality for the autonomous system to facilitate human-like conversations was created. This work’s success was largely due to the diverse team that included expertise in Space Systems Engineering, Human Computer Interaction, Aerospace Engineering, Computer Science, Biomedical Engineering, and Applied Physics. The differing perspectives fostered elaborate discussions, resulting in the conception of three main interactions: (1) User-System, (2) NPAS-System, and (3) Environment-System. The system developed, i.e. the VUI, had to be unique, efficient, and intuitive; thus, the team crafted a personality for the system to enable human-like conversation. User surveys sent to students and young professionals were used to help determine these personality traits by capturing perspectives and expectations of the “Artemis Generation Astronauts”. To further simulate human-like conversations, the system had to be able to quickly interpret user speech and be able to integrate with NASA’s NPAS system for quick and reliable information transfer. Results of this research include (1) a working prototype user interface, that is compatible with NASA’s NPAS system; (2) software that demonstrates the ability to interpret user requests and respond appropriately; (3) the capability to implement fully expanded conversations between user and system using intuitive communication in four request categories; and (4) software and hardware recommendations that optimize the system’s ability to operate, i.e. be heard, in a noisy environment. The technologies chosen for this project’s demonstrations included the following: Raspberry Pi, RASA, Mozilla Deep Speech, Coqui, RTX Voice and Adobe XD. This work has laid the foundation for the development of VUI’s used for autonomy, and is intended to provide guidance for future VUI development.

Tara Vega↗

Widespread opportunities for materials engineering of nanocrystals: Synthetically tailorable effects and methodologies

Since their initial development, semiconductor nanocrystals (NCs) and metal nanoparticles (NPs) have become widely utilized in a variety of applications, including solar energy harvesting, lighting, catalysis, biomedical imaging, and targeted cancer treatments. Because of their reduced dimensionality, NCs and NPs have vastly different optical and electronic properties than their bulk counterparts, and the properties often depend heavily on the NC or NP surface. Surface defects and ligands alter the optoelectronic properties of NCs and NPs and affect their interaction with the environment, allowing tailoring of their properties without changing the overall chemical composition. In this review, we discuss research progress focusing on optoelectronic properties of NPs and NCs and their respective applications. We highlight how different surface treatments and ligand functionalization of nanomaterials can influence these applications.

36 MATERIALS SCIENCE↗

Why is the winner the best?

International benchmarking competitions have become fundamental for the comparative performance assessment of image analysis methods. However, little attention has been given to investigating what can be learnt from these competitions. Do they really generate scientific progress? What are common and successful participation strategies? What makes a solution superior to a competing method? To address this gap in the literature, we performed a multi- center study with all 80 competitions that were conducted in the scope of IEEE ISBI 2021 and MICCAI 2021. Statistical analyses performed based on comprehensive descriptions of the submitted algorithms linked to their rank as well as the underlying participation strategies revealed common characteristics of winning solutions. These typically include the use of multi-task learning (63%) and/or multi-stage pipelines (61%), and a focus on augmentation (100%), im- age preprocessing (97%), data curation (79%), and post- processing (66%). The “typical” lead of a winning team is a computer scientist with a doctoral degree, five years of experience in biomedical image analysis, and four years of experience in deep learning. Two core general development strategies stood out for highly-ranked teams: the reflection of the metrics in the method design and the focus on analyzing and handling failure cases. According to the organizers, 43% of the winning algorithms exceeded the state of the art but only 11% completely solved the respective domain problem. The insights of our study could help researchers (1) improve algorithm development strategies when approaching new problems, and (2) focus on open research questions revealed by this work.

Eisenmann, Matthias↗

SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use in specific applications such as tissue classification and changes during radiation therapy utilizing a standard imaging protocol. Authors have the following disclosures: a research agreement with Philips Medical systems (Hugo, Weiss), a license agreement with Varian Medical Systems (Hugo, Weiss), research grants from the National Institute of Health (Hugo, Weiss), UpToDate royalties (Weiss), and none(Mahon, Ford, Karki). Authors have no potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-662: Feasibility Study of Fe3O4/TaOx Nano Particles as a Radiosensitizer for Radiation Therapy

Purpose: To investigate the feasibility of using multifunctional Fe{sub 3}O{sub 4}/TaOx(core / shell) nano particles developed for CT and MRI contrast agent as dose enhancing radiosensitizers. Methods: Firstly, to verify the imaging detectability of Fe{sub 3}O{sub 4}/TaOx nano particles, in-vivo tests were conducted. Approximately 600 mg/kg of 19 nm diameter Fe{sub 3}O{sub 4}/TaOx nano particles dispersed in phosphate buffered saline(PBS) were injected to ten nude Balb/c mice through the tail vein. Difference between pre- and post-injection images was analyzed by computing the pixel histogram and correlation coefficient factor using MATLAB in the user defined ROI. Secondly, to quantify the potential therapeutic enhancement with nano materials, DER (Dose Enhancement Ratio) and number of SER (Secondary Electron Ratio) were computed using TOPAS(ver.2.0 P-03) MC simulation. Results: In CT, MRI imaging, the aorta, the blood vessel, and the liver were clearly visualized after intravenous injection of Fe{sub 3}O{sub 4}/TaOx nano particles. There was large different between pre and post-injection images of Histogram data and Coefficients of correlation factor in CT and MR are 0.006, 0.060, respectively. When 70 MeV protons were irradiated for a Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, DER was 2.59, 2.41, 1.68, 1.54 and 1.36 respectively. Similarly, SER increment was 2.31, 2.15, 1.56, 1.46, and 1.27 for Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, respectively. Conclusion: Fe{sub 3}O{sub 4}/TaOx nano particles have potential as a multifunctional agent which enhances the accuracy in cancer detection through visualization of developed tumor lesion and increases the therapeutic effect in proton therapy. The dose enhancement with Fe{sub 3}O{sub 4}/TaOx was estimated as half of the Gold. However, tumor targeting such as combined with magnetic field may overcome the low DER. This research was supported by the NRF funded by the Ministry of Science, ICT & Future Planning (2012M3A9B6055201 and 2012R1A1A2042414), Samsung Medical Center grant[GFO1130081].

60 APPLIED LIFE SCIENCES↗

Medical countermeasures for extraterrestrial environments: Current status and future prospects with focus on acute injuries

In all space exploratory activities involving humans there are associated risks to health and well-being. Exposure to ionizing radiation represents one of the more serious health concerns. Although medical issues can arise shortly following the rare acute exposures, the more likely radiation-associated injuries will manifest in a delayed fashion following sub-acute exposures or protracted exposures to relatively low radiation doses. The radiological conditions that present these health risks during extraterrestrial space travel are presented in this article, along with current physical and medical countermeasures for such exposure contingencies. The aim of this article is to discuss radiation medical countermeasures that may be considered for future space exploration and travel. Biomedical advances have occurred toward the control and minimization of acute, sub-acute, and fractionated radiation exposure injuries, whether they stem from intentional application of radio-therapeutic procedures or unintentional, accidental terrestrial-based exposures. Those advances, based largely on novel bioengineering, genetic, and combinatorial pharmaceutical strategies, are briefly reviewed here, along with the promising prospects of additional, new and improved medical countering systems/agents that will be forthcoming with additional research and development efforts.

Acute/chronic radiation injuries↗

SU-E-T-775: Use of Electronic Portal Imaging Device (EPID) for Quality Assurance (QA) of Electron Beams On Varian Truebeam System

Purpose: In a previous study we have demonstrated the feasibility of using EPID to QA electron beam parameters on a single Varian TrueBeam LINAC. This study aims to provide further investigation on (1) reproducibility of using EPID to detect electron beam energy changes on multiple machines and (2) evaluation of appropriate calibration methods to compare results from different EPIDs. Methods: Ad-hoc mode electron beam images were acquired in developer mode with XML code. Electron beam data were collected on a total of six machines from four institutions. A custom-designed double-wedge phantom was placed on the EPID detector. Two calibration methods - Pixel Sensitivity Map (PSM) and Large Source-to-Imager Distance Flood Field (LSID-FF) - were used. To test the sensitivity of EPID in detecting energy drifts, Bending Magnet Current (BMC) was detuned to invoke energy changes corresponding to ∼±1.5 mm change in R50% of PDD on two machines from two institutions. Percent depth ionization (PDI) curves were then analyzed and compared with the respective baseline images using LSID-FF calibration. For reproducibility testing, open field EPID images and images with a standard testing phantom were collected on multiple machines. Images with and without PSM correction for same energies on different machines were overlaid and compared. Results: Two pixel shifts were observed in PDI curve when energy changes exceeded the TG142 tolerance. PSM showed the potential to correct the differences in pixel response of different imagers. With PSM correction, the histogram of images differences obtained from different machines showed narrower distributions than those images without PSM correction. Conclusion: EPID is sensitive for electron energy changes and the results are reproducible on different machines. When overlaying images from different machines, PSM showed the ability to partially eliminate the intrinsic variation of various imagers. Research Funding from Varian Medical Systems Inc.Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

SU-F-T-593: Technical Treatment Accuracy in a Clinic of Fractionated Stereotactic Radiosurgery

Purpose: The purpose of this study is to estimate technical treatment accuracy in fractionated stereotactic radiosurgery (fSRS) using extend system (ES) of Gamma Knife (GK). Methods: The fSRS with GK relies on a patient specific re-locatable immobilization system. The reference treatment position is estimated using a digital probe and a repositioning check tool (RCT). The “calibration values” of RCT apertures were compared with measured values on RCT-QA tool to evaluate the standard error (SE) associated with RCT measurements. A treatment plan with single “4 mm collimator shot” was created to deliver a radiation dose of 5 Gy at the predefined plane of a newly designed in-house head-neck phantom. The plan was investigated using radiochromic EBT3 films. The stereotactic CT imaging of a designed mini CT phantom and distortion study of MR imaging, were combined to calculate imaging SE. The focal precision check for GK machine tolerance was performed using a central diode test tool. Results: Twenty observations of RCT and digital probe, shown the SE of +/−0.0186mm and +/−0.0002mm respectively. A mean positional shift of 0.2752mm (σ=0.0696mm) was observed for twenty similar treatment settings of head-neck phantom. The difference between radiological and predefined exposure point was 0.4650mm and 0.4270mm; for two independent experiments. The imaging studies showed a combined SE of +/− 0.1055mm. Twenty frequent runs of a diode test tool showed the tolerance SE of +/−0.0096mm. If, the measurements are considered to be at 95% of confidence level, an expanded uncertainty was evaluated as +/− 0.2371mm with our system. The positional shift, when combined with an expanded uncertainty, a trivial variation of 0.07mm (max) was observed in comparing resultant radiological precision through film investigations. Conclusion: The study proposes an expression of “technical treatment accuracy” within “known uncertainties” is rational in the estimation of routine fSRS quality. The research work is supported by the research section of “All India Institute of Medical Sciences” - New Delhi, India under project no A-247.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-01: Device Approval Process

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-02: Device Adverse Events and Compliance

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Research Activities in Medical Physics

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-04: Partnerships

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

The developments in modifying functionality of lignin and its application in biocomposites

With the advancement of sustainable material innovations, renewable natural biopolymers are gradually replacing traditional metal and petroleum-based synthetic materials due to their environmental friendliness, biodegradability, and economic advantages. Lignin, the second most abundant natural aromatic polymer in the plant kingdom, has emerged as a key candidate raw material for the development of green polymer systems because of its unique phenylpropane unit network structure, high carbon content, and rich functional group characteristics. However, challenges such as the inherent structural complexity, chemical inertness, and uneven molecular weight distribution of lignin limit its direct application. By employing modification strategies such as chemical functionalization and physical regulation, researchers can precisely control its reactivity, thermal stability, and interfacial compatibility, enabling the preparation of high-performance lignin-based functional composites. Here, this paper systematically reviews the principles and methodological advancements in lignin's multi-dimensional modification technology. It analyzes the mechanisms by which various chemical and physical modification techniques enhance the mechanical properties, functional responsiveness, and environmental adaptability of materials, and discusses innovative applications in fields such as intelligent packaging, biomedical materials, and energy storage devices. Furthermore, this review addresses the key challenges encountered in the high-value transformation of lignin, with the aim of offering a theoretical framework and technical pathway for the transformative development of lignin from agricultural and forestry by-products to functional material platforms.

Functional composites↗

Fracture strength and elastic modulus as a function of porosity for hydroxyapatite and other brittle materials Part I

Porous brittle materials are used as filters, catalyst supports, solid oxide fuel cells and biomedical materials. However the literature on the Weibull modulus, m, versus volume fraction porosity, P, is extremely limited despite the importance of m as a gauge of mechanical reliability. In Part I of this study, m is determined for 441 sintered hydroxyapatite (HA) specimens fractured in biaxial flexure for 0.08 P 0.62. In this study, we analyze a combined data set collected from the literature that represents work from a total of 17 different research groups (including the present authors), eight different materials and more than 1560 oxide and non-oxide specimens, the m versus P plot is Ushaped with a wide band of m values for P < 0.1 (Region I) and P > 0.55 (Region III), and a narrower band of m values in the intermediate porosity region of 0.1 < P < 0.55 (Region II). The limited range of m ( 4 < m < 11) in Region II has important implications since Region II includes the P range for the majority of the applications of porous brittle materials. Part II of this study focuses on the P dependence of the mean fracture strength,< f >, and the Young s modulus E for the HA specimens tested in Part I along with literature data for other brittle materials. Both < f > and E are power law functions of the degree of densification, , where = 1 P/PG and PG is the green (unfired) porosity.

30 DIRECT ENERGY CONVERSION↗

Functional and Anatomical Imaging in Patients with Ischemic Symptoms and Known Coronary Artery Disease

Purpose of Review: This review is aimed at summarizing recent advances in functional, anatomical, and hybrid imaging techniques used in the assessment of ischemic complaints in patients with known coronary artery disease (CAD). Recent Findings: Cardiovascular imaging has seen significant growth over the last decade in the fields of coronary computed tomography angiography (CCTA), FFR derived from CCTA, cardiac magnetic resonance, radionuclide myocardial perfusion imaging, and hybrid imaging for the purposes of evaluating symptoms concerning for ischemia. This growth stems from refinement of imaging techniques and hardware and software advances that have made current techniques more accurate with less acquisition time. However, every anatomic and functional imaging modality has important technical and patient-specific limitations. This review assesses these issues, guides a patient-centered imaging approach, and identifies important research questions to resolve. Summary: Recent advances in non-invasive cardiovascular imaging can provide important information in patients with known CAD beyond traditional imaging techniques; the use of these novel tools refines the clinical management of complex patients with ischemic symptoms and known CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-304-02: Robust and Efficient Process for Acceptance Testing of Varian TrueBeam Linacs Using An Electronic Portal Imaging Device (EPID)

Purpose: The purpose of this project was to develop a process that utilizes the onboard kV and MV electronic portal imaging devices (EPIDs) to perform rapid acceptance testing (AT) of linacs in order to improve efficiency and standardize AT equipment and processes. Methods: In this study a Varian TrueBeam linac equipped with an amorphous silicon based EPID (aSi1000) was used. The conventional set of AT tests and tolerances was used as a baseline guide, and a novel methodology was developed to perform as many tests as possible using EPID exclusively. The developer mode on Varian TrueBeam linac was used to automate the process. In the current AT process there are about 45 tests that call for customer demos. Many of the geometric tests such as jaw alignment and MLC positioning are performed with highly manual methods, such as using graph paper. The goal of the new methodology was to achieve quantitative testing while reducing variability in data acquisition, analysis and interpretation of the results. The developed process was validated on two machines at two different institutions. Results: At least 25 of the 45 (56%) tests which required customer demo can be streamlined and performed using EPIDs. More than half of the AT tests can be fully automated using the developer mode, while others still require some user interaction. Overall, the preliminary data shows that EPID-based linac AT can be performed in less than a day, compared to 2–3 days using conventional methods. Conclusions: Our preliminary results show that performance of onboard imagers is quite suitable for both geometric and dosimetric testing of TrueBeam systems. A standardized AT process can tremendously improve efficiency, and minimize the variability related to third party quality assurance (QA) equipment and the available onsite expertise. Research funding provided by Varian Medical Systems. Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-TeP3-09: Proton Minibeam Radiation Therapy Increases Normal Tissue Resistance

Purpose: The dose tolerances of normal tissues continue being the main limitation in radiotherapy. To overcome it, we recently proposed a novel concept: proton minibeam radiation therapy (pMBRT) [1]. It allies the physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams (minibeam radiation therapy) [2]. The dose distributions are such that the tumor receives a homogeneous dose distribution, while normal tissues benefit from the spatial fractionation of the dose. The objective of our work was to implement this promising technique at a clinical center (Proton therapy center in Orsay) in order to evaluate the potential gain in tissue sparing. Methods: Dose distributions were measured by means of gafchromic films and a PTW microdiamond detector (60019). Once the dosimetry was established, the whole brain of 7 weeks old male Fischer 344 rats was irradiated. Half of the animals received conventional seamless proton irradiation (25 Gy in one fraction). The other rats were irradiated with pMBRT (58 Gy peak dose in one fraction). The average dose deposited in the same targeted volume was in both cases 25 Gy. Results: The first complete set of dosimetric data in such small proton field sizes was obtained [3]. Rats treated with conventional proton irradiation exhibited severe moist desquamation and permanent epilation afterwards. The minibeam group, on the other hand, exhibited no skin damage and no clinical symptoms. MRI imaging and histological analysis are planned at 6 months after irradiation. Conclusion: Our preliminary results indicate that pMBRT leads to an increase in tissue resistance. This can open the door to an efficient treatment of very radioresistant tumours. [1] Prezado et al. Med. Phys. 40, 031712, 1–8 (2013).[2] Prezado et al., Rad. Research. 184, 314-21 (2015). [3] Peucelle et al., Med. Phys. 42 7108-13 (2015).

60 APPLIED LIFE SCIENCES↗

Enabling Graph Appliance for Genome Assembly

In recent years, there has been a huge growth in the amount of genomic data available as reads generated from various genome sequencers. The number of reads generated can be huge, ranging from hundreds to billions of nucleotide, each varying in size. Assembling such large amounts of data is one of the challenging computational problems for both biomedical and data scientists. Most of the genome assemblers developed have used de Bruijn graph techniques. A de Bruijn graph represents a collection of read sequences by billions of vertices and edges, which require large amounts of memory and computational power to store and process. This is the major drawback to de Bruijn graph assembly. Massively parallel, multi-threaded, shared memory systems can be leveraged to overcome some of these issues. The objective of our research is to investigate the feasibility and scalability issues of de Bruijn graph assembly on Cray s Urika-GD system; Urika-GD is a high performance graph appliance with a large shared memory and massively multithreaded custom processor designed for executing SPARQL queries over large-scale RDF data sets. However, to the best of our knowledge, there is no research on representing a de Bruijn graph as an RDF graph or finding Eulerian paths in RDF graphs using SPARQL for potential genome discovery. In this paper, we address the issues involved in representing a de Bruin graphs as RDF graphs and propose an iterative querying approach for finding Eulerian paths in large RDF graphs. We evaluate the performance of our implementation on real world ebola genome datasets and illustrate how genome assembly can be accomplished with Urika-GD using iterative SPARQL queries.

Big data↗