Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗

Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation

Purpose: To measure depth dose curves for a 67.5 ± 0.1 MeV proton beam for benchmarking and validation of Monte Carlo simulation. Methods: Depth dose curves were measured in 2 beam lines. Protons in the raw beam line traversed a Ta scattering foil, 0.1016 or 0.381 mm thick, a secondary emission monitor comprised of thin Al foils, and a thin Kapton exit window. The beam energy and peak width and the composition and density of material traversed by the beam were known with sufficient accuracy to permit benchmark quality measurements. Diodes for charged particle dosimetry from two different manufacturers were used to scan the depth dose curves with 0.003 mm depth reproducibility in a water tank placed 300 mm from the exit window. Depth in water was determined with an uncertainty of 0.15 mm, including the uncertainty in the water equivalent depth of the sensitive volume of the detector. Parallel-plate chambers were used to verify the accuracy of the shape of the Bragg peak and the peak-to-plateau ratio measured with the diodes. The uncertainty in the measured peak-to-plateau ratio was 4%. Depth dose curves were also measured with a diode for a Bragg curve and treatment beam spread out Bragg peak (SOBP) on the beam line used for eye treatment. The measurements were compared to Monte Carlo simulation done with GEANT4 using TOPAS. Results: The 80% dose at the distal side of the Bragg peak for the thinner foil was at 37.47 ± 0.11 mm (average of measurement with diodes from two different manufacturers), compared to the simulated value of 37.20 mm. The 80% dose for the thicker foil was at 35.08 ± 0.15 mm, compared to the simulated value of 34.90 mm. The measured peak-to-plateau ratio was within one standard deviation experimental uncertainty of the simulated result for the thinnest foil and two standard deviations for the thickest foil. It was necessary to include the collimation in the simulation, which had a more pronounced effect on the peak-to-plateau ratio for the thicker foil. The treatment beam, being unfocussed, had a broader Bragg peak than the raw beam. A 1.3 ± 0.1 MeV FWHM peak width in the energy distribution was used in the simulation to match the Bragg peak width. An additional 1.3–2.24 mm of water in the water column was required over the nominal values to match the measured depth penetration. Conclusions: The proton Bragg curve measured for the 0.1016 mm thick Ta foil provided the most accurate benchmark, having a low contribution of proton scatter from upstream of the water tank. The accuracy was 0.15% in measured beam energy and 0.3% in measured depth penetration at the Bragg peak. The depth of the distal edge of the Bragg peak in the simulation fell short of measurement, suggesting that the mean ionization potential of water is 2–5 eV higher than the 78 eV used in the stopping power calculation for the simulation. The eye treatment beam line depth dose curves provide validation of Monte Carlo simulation of a Bragg curve and SOBP with 4%/2 mm accuracy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-166: Characterization of Efficiency and Plan Quality for the FFF Beams On Various Anatomical Sites

Purpose: To characterize efficiency and plan quality for the FFF beams for various sites. Methods: 5 brain, Head and Neck, prostate, lung and liver cancer patients IMRT plans (25 total) were generated on either Prowess 4.6 or Eclipse 13.5 using the same dose constraints for each treatment site. Step and shoot with static gantry IMRT was used for treatment delivery. PTV coverage, critical structure doses, MUs, number of segments and beam on times were compared. Results: The average PTV size was 29.0, 34.9, 89.2, 257.6, 289.2 cm3 for liver, lung, prostate, head and neck and brain respectively.All plans were normalized such that 95% of the PTV volume would receive at least 95% of prescribed dose. All doses to the critical structures for both the FFF and flat beam met the targeted dose constraints.For plans with field sizes < 10 cm, the number of segments and MUs required to achieve the same plan quality were similar. For these small field sizes with large dose per fraction, an increase in efficiency up to 58.8% is seen.Plans with field sizes > 10 cm, required 10% – 20% more segments and MUs for the FFF beam to achieve the same plan quality as the flat beam. Despite this, for fraction sizes less than 2.5 Gy the FFF beam is still approximately 13.9% more efficient in terms of delivery time. Conclusion: For the various treatment sites studied here, plans generated with the FFF beam were dosimetrically similar to those generated with a flattened beam. Despite the greater number of MUs and segments required to achieve the same plan quality as the flat beam for some plans, the FFF beam is still more efficient compared to the flat beam.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer Institute.

07 ISOTOPE AND RADIATION SOURCES↗

WE-AB-BRB-03: Investigation of a Small Photomultiplier-Based Probe for Use in Beam Diagnostics and Medical Dosimetry

Purpose: Investigate the use of a small photomultiplier-based probe as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams was detected by a small photomultiplier tube (PMT). Measurements of Clinac beams were made both in air and by inserting the PMT directly into a water phantom. A conical collimator placed in front of the PMT reduced the angular acceptance and the detection of scattered light. With this arrangement, we obtained response curves as a function of depth along the central axis similar in shape and magnitude to those obtained with ionization chambers. Subsequent measurements were made with the PMT covered in aluminum foil, obtaining a signal arising primarily from direct Cerenkov light produced in the glass entrance window. With an oscilloscope and amplifier/MCA system, we were able to monitor the response to individual beam pulses and observe variations in the beam pulse shape and magnitude as a function of dose rate. Results: Using Cerenkov signals detected by a PMT, we were able to obtain reasonable beam quality metrics, and the response was found to be linear over a range of dose rates. The fast response of the PMT allowed for the observation of small changes in the shape and magnitude of the beam pulse. With this system we were able to detect small changes in the dose per pulse delivered by the accelerator. Conclusion: A small PMT probe has shown promise as a beam diagnostic and medical dosimetry tool. Its fast response allows for real time beam pulse monitoring, and the integrated response can yield relative and perhaps even absolute dose information with a properly calibrated system. For accelerator diagnostics, monitoring of the beam pulse shape can aid in beam tuning, particularly in electron mode, where no target current pulse is available.

60 APPLIED LIFE SCIENCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

07 ISOTOPE AND RADIATION SOURCES↗

Electrostatic beams from tailored plasmas in a Penning-Malmberg trap

In recent work, a technique was developed to extract high quality beams from single-component plasmas confined in a Penning-Malmberg trap in a 4.8 T magnetic field. In this paper, a procedure is developed to extract these beams from the confining magnetic field and then focus them to create especially tailored electrostatic beams. Electron beams are extracted from the field in two stages: they are first transported to a region of reduced field (1 mT), and then taken to zero field with a nonadiabatic, fast extraction. Once in the field-free region, the beams are focused using an Einzel lens. Experimental results and numerical simulations are presented to illustrate the extraction and focusing process. Theoretical expressions are developed to describe the modifications to the relevant beam energy and spatial distributions. Where possible, analytic expressions are presented for the case relevant here of beams with Gaussian radial profiles. Beam emittance considerations are discussed as well as prospects for further development of these techniques. Application of these techniques to provide high-quality positron beams is also discussed.

43 PARTICLE ACCELERATORS↗

First neutral beam injection experiments on KSTAR tokamak

The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 {mu}P, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8 deg. The ion species ratio is D{sup +}:D{sub 2}{sup +}:D{sub 3}{sup +}= 75:20:5 at beam current density of 85 mA/cm{sup 2}. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T{sub i} and T{sub e} profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

43 PARTICLE ACCELERATORS↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Influence of laser beam profile on electromagnetically induced absorption

We compared, experimentally and theoretically, Hanle electromagnetically induced absorption (EIA) obtained using Gaussian and {Pi}-shaped laser beams 3 mm in diameter. The study was done by measuring the transmission of a laser locked to the F{sub g}=2{yields}F{sub e}=3 transition at the D{sub 2} line of {sup 87}Rb in a vacuum cell. EIA linewidths obtained for the two laser profiles were significantly different in the range of laser intensities 1-4 mW/cm{sup 2}. EIA with the {Pi}-shaped laser beam has a broad intensity maximum and linewidths larger than those obtained with the Gaussian beam profile. We also studied Hanle EIA by measuring the transmission of selected segments of the entire laser beam by placing a small movable aperture in front of the detector. Waveforms so obtained in Hanle EIA resonances were strongly influenced both by the radial distance of the transmitted segment from the beam center and by the radial profile of the laser beam. We show that outer regions of Gaussian beam, and central regions of the {Pi}-shaped beam generate the narrowest lines. The different behaviors of EIA owing to different beam profiles revealed by both theory and experiment indicate the importance of the radial profile of the laser beam for proper modeling of coherent effects in alkali metal vapors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonant and random excitations on the proton beam in the Large Hadron Collider for active halo control with pulsed hollow electron lenses

We present the results of numerical simulations and experimental studies about the effects of resonant and random excitations on proton losses, emittances, and beam distributions in the Large Hadron Collider (LHC). In addition to shedding light on complex nonlinear effects, these studies are applied to the design of hollow electron lenses (HEL) for active beam halo control. In the High-Luminosity Large Hadron Collider (HL-LHC), a considerable amount of energy will be stored in the beam tails. To control and clean the beam halo, the installation of two hollow electron lenses, one per beam, is being considered. In standard electron-lens operation, a proton bunch sees the same electron current at every revolution. Pulsed electron beam operation (i.e., different currents for different turns) is also considered, because it can widen the range of achievable halo removal rates. For an axially symmetric electron beam, only protons in the halo are excited. If a residual field is present at the location of the beam core, these particles are exposed to time-dependent transverse kicks and to noise. We discuss the numerical simulations and the experiments conducted in 2016 and 2017 at injection energy in the LHC. The excitation patterns were generated by the transverse feedback and damping system, which acted as a flexible source of dipole kicks. Proton beam losses, emittances, and transverse distributions were recorded as a function of excitation patterns and strengths. The resonant excitations induced rich dynamical effects and nontrivial changes of the beam distributions, which, to our knowledge, have not previously been observed and studied in this detail. We conclude with a discussion of the tolerable and achievable residual fields and proposals for further studies.

43 PARTICLE ACCELERATORS↗

The CNAO dose delivery system for modulated scanning ion beam radiotherapy

Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.

60 APPLIED LIFE SCIENCES↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Analytic model for the breakup of a coasting beam with space charge in isochronous accelerators

An analytical model based on the negative mass instability is introduced in this paper to explain the formation of the breakup of a coasting beam into small clusters in isochronous machines such as the case observed by Pozdeyev and Rodriguez in a small isochronous ring. Solving Poisson's equation in both charge and vacuum regions with the longitudinal beam density perturbation, the coherent radial space charge force which decreases the transition gamma is obtained. It is found that the modified transition gamma depends on the wave number of the density perturbation, longitudinal beam density distribution, beam intensity, and beam size. By combining the longitudinal space charge force caused by the perturbation and the modified transition gamma, a dispersion relation for a monoenergetic beam is derived and evaluated for the fastest-growing instability mode in terms of the beam parameters, such as energy, bunch length, intensity, and emittance. The fastest-growing negative mass mode number, which determines not only the cluster number but also the growth rate of the instability, is proportional to the orbit radius and inversely proportional to the initial beam size. With the growth of the instability, the particles at the points of local minimum density move to the ones of local maximum density, with the transition gamma increasing. Since the growth rate depends on the longitudinal density distribution, therefore, instead of a constant growth rate, our model shows that the growth rate decreases with time. The results above can be applied to both short and long wavelength limits. As an important application of this theory, the beam breakup effect in the isochronous cyclotron CYCIAE-100 is predicted.

43 PARTICLE ACCELERATORS↗

Voltage holding study of 1 MeV accelerator for ITER neutral beam injector

Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration, which leads to discharge initiation at lower voltage. To reduce the electric field concentration in the MeV accelerator, gaps between the grid supports were expanded and curvature radii at the support corners were increased. After the modifications, the accelerator succeeded in sustaining -1 MV in vacuum without beam acceleration. However, the beam energy was still limited at a level of 900 keV with a beam current density of 150 A/m{sup 2} (346 mA) where the 3 x 5 apertures were used. Measurement of the beam profile revealed that deflection of the H{sup -} ions was large and a part of the H{sup -} ions was intercepted at the acceleration grid. This causes high heat load on the grids and the breakdowns during beam acceleration. To suppress the direct interception, new grid system was designed with proper aperture displacement based on a 3D beam trajectory analysis. As the result, the beam deflection was compensated and the voltage holding during the beam acceleration was improved. Beam parameter of the MeV accelerator was increased to 980 keV, 185 A/m{sup 2} (427 mA), which is close to the requirement of ITER accelerator (1 MeV, 200 A/m{sup 2}).

43 PARTICLE ACCELERATORS↗

Self-pinched transport of a high ν/γ electron beam

The self-pinched transport of a 0.5 MeV, 18 kA cylindrical electron beam has been studied experimentally and computationally. The relatively low voltage and high current required for materials surface modification applications leads to complicated beam dynamics as the Alfven limit is approached. Transport and focusing of the high ν/γ beam was done in a sub-Torr, neutral gas-filled, conducting tube in the ion-focused regime. In this regime, beam space charge forces are progressively neutralized to allow focusing of the beam by its self-magnetic field. The beam exhibits stable envelope oscillations as it is efficiently and reproducibly propagated for distances greater than a betatron wavelength. Experimental results follow the trends seen in 2-D particle-in-cell simulations. Results show that the input electron beam can be periodically focused to a peaked profile with the beam half-current radius decreased by a factor of 2.84. This results in an increase of a factor of 8 in beam current density. This focusing is sufficient to produce desired effects in the surface layers of metallic materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗