Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Design of Low Power CMOS Read-Out with TDI Function for Infrared Linear Photodiode Array Detectors

A new low voltage CMOS infrared readout circuit using the buffer-direct injection method is presented. It uses a single supply voltage of 1.8 volts and a bias current of 1uA. The time-delay integration technique is used to increase the signal to noise ratio. A current memory circuit with faulty diode detection is used to remove dark current for background compensation and to disable a photodiode in a cell if detected as faulty. Simulations are shown that verify the circuit that is currently in fabrication in 0.5ym CMOS technology.

Vizcaino, Paul↗

MWIR and LWIR Megapixel QWIP Focal Plane Arrays

A mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal plane array has been demonstrated with excellent imagery. MWIR focal plane has given noise equivalent differential temperature (NETD) of 19 mK at 95K operating temperature with f/2.5 optics at 300K background and LWIR focal plane has given NEDT of 13 mK at 70K operating temperature with same optical and background conditions as MWIR array. Both of these focal plane arrays have shown background limited performance (BLIP) at 90K and 70K operating temperatures with the same optics and background conditions. In this paper, we will discuss their performance in quantum efficiency, NETD, uniformity, and operability.

multi band↗

Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of target-to-background ratio, target size, emission scan duration, and activity on physical figures of merit for a 3D LSO-based whole body PET/CT scanner

The aim of our work is to describe the way in which physical figures of merit such as contrast-to-noise ratio (CNR) behave when varying acquisition parameters such as emission scan duration (ESD) or activity at the start of acquisition (A{sub acq}) that in clinical practice can be selected by the user, or object properties such as target dimensions or target-to-background (T/B) ratio, which depend uniquely on the intrinsic characteristics of the object being imaged. Figures of merit, used to characterize image quality and quantitative accuracy for a 3D-LSO based PET/CT scanner, were studied as a function of ESD and A{sub acq} for different target sizes and T/B ratios using a multivariate approach in a wide range of conditions approaching the ones that can be encountered in clinical practice. An annular ring of water bags of 3 cm thickness was fitted over an IEC phantom in order to obtain counting rates similar to those found in average patients. The average scatter fraction (SF) of the modified IEC phantom was similar to the mean SF measured on patients with a similar scanner. A supplemental set of micro-hollow spheres was positioned inside the phantom. The NEMA NU 2-2001 scatter phantom was positioned at the end of the IEC phantom to approximate the clinical situation of having activity that extends beyond the scanner. The phantoms were filled with a solution of water and {sup 18}F (12 kBq/mL) and the spheres with various T/B ratios of 22.5, 10.3, and 3.6. Sequential imaging was performed to acquire PET images with varying background activity concentrations of about 12, 9, 6.4, 5.3, and 3.1 kBq/mL, positioned on the linear portion of the phantom's NECR curve, well below peak NECR of 61.2 kcps that is reached at 31.8 kBq/mL. The ESD was set to 1, 2, 3, and 4 min/bed. With T/B ratios of 3.6, 10.3, and 22.5, the 13.0, 8.1, and 6.5 mm spheres were detectable for the whole ranges of background activity concentration and ESD, respectively. The ESD resulted as the most significant predictor of CNR variance, followed by T/B ratio and the cross sectional area of the given sphere. Only last comes A{sub acq} with a weight more than halved with respect to ESD. Thus, raising ESD seems to be much more effective than raising A{sub acq} in order to obtain higher CNR, which is the physical figure of merit closely related with target detectability, at least in the simple task of the signal known exactly background known exactly model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A perturbative analysis of synchrotron spectral index variation over the microwave sky

In this paper, we implement a perturbative approach, first proposed by Bouchet and Gispert, to estimate the variation of the spectral index of galactic polarized synchrotron emission, using a linear combination of simulated Stokes Q polarization maps of selected frequency bands from WMAP and Planck observations on a region of sky dominated by the synchrotron Stokes Q signal. We find that a first order perturbative analysis recovers the input spectral index map well. Along with the spectral index variation map, our method provides a fixed reference index, β-hat {sub 0s}, over the sky portion being analyzed. Using Monte-Carlo simulations, we find that 〈 β-hat {sub 0s}〉=−2.84±0.01, which matches very closely with the position of a peak at β{sub s}(p)=−2.85 of the empirical probability density function of input synchrotron indices obtained from the same sky region. For thermal dust, the mean recovered spectral index 〈 β-hat {sub d}〉=2.00±0.004 from simulations, matches very well with the spatially fixed input thermal dust spectral index β{sub d}=2.00. As accompanying results of the method, we reconstruct cosmic microwave background, thermal dust, and a synchrotron template components with fixed spectral indices over the entire sky region. We use, in our analysis, full pixel–pixel noise covariance matrices of all frequency bands, estimated from the sky region being analyzed. The perturbative technique of this work (1) can build a model with an arbitrary but sufficient degree of accuracy (and precession) as allowed by the data and (2) can produce maximum likelihood estimators for reference indices and templates asymptotically.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing patchy reionization through τ-21 cm correlation statistics

We consider the cross-correlation between free electrons and neutral hydrogen during the epoch of reionization (EoR). The free electrons are traced by the optical depth to reionization τ, while the neutral hydrogen can be observed through 21 cm photon emission. As expected, this correlation is sensitive to the detailed physics of reionization. Foremost, if reionization occurs through the merger of relatively large halos hosting an ionizing source, the free electrons and neutral hydrogen are anticorrelated for most of the reionization history. A positive contribution to the correlation can occur when the halos that can form an ionizing source are small. A measurement of this sign change in the cross-correlation could help disentangle the bias and the ionization history. We estimate the signal-to-noise ratio of the cross-correlation using the estimator for inhomogeneous reionization τ-hat {sub ℓm} proposed by Dvorkin and Smith. We find that with upcoming radio interferometers and cosmic microwave background (CMB) experiments, the cross-correlation is measurable going up to multipoles ℓ ∼ 1000. We also derive parameter constraints and conclude that, despite the foregrounds, the cross-correlation provides a complementary measurement of the EoR parameters to the 21 cm and CMB polarization autocorrelations expected to be observed in the coming decade.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The interstellar line spectra of zeta Ophiuchi and zeta Persei and their relation to the short wavelength microwave background radiation

Thirty-one high dispersion Coude spectrograms of zeta Ophiuchi and seven of zeta Persei were numerically synthesized to produce high resolution, low noise spectra in the interval 3650 A to 4350 that yield data on atomic and molecular absorption in well-defined regions of the interstellar medium. The detection threshold is improved by as much as a factor 5 over single plates. Several interstellar lines were discovered in the zeta Oph - 15km/sec cloud and the zeta Per + 13 km/sec cloud.

Bortolot, V. J., Jr.↗

Influence of inhomogeneities of the plasma density and electric field on the generation of electrostatic noise in the auroral zone

In order to study instabilities caused by inhomogeneities of the electric field and plasma density in the auroral zone, numerical algorithms are developed and numerical simulations are performed for different conditions in the background plasma. To this end, a nonlocal dispersion relation for a given type of wave is analyzed. It is shown that the dispersion relation has unstable solutions in a wide range of frequencies and wavenumbers. These solutions manifest themselves in satellite observations as a broadband spectrum of electrostatic perturbations. Two mechanisms of broadband noise generation related to the gradients of the density and electric field are compared.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmic topology. Part I. Limits on orientable Euclidean manifolds from circle searches

The Einstein field equations of general relativity constrain the local curvature at every point in spacetime, but say nothing about the global topology of the Universe. Cosmic microwave background anisotropies have proven to be the most powerful probe of non-trivial topology since, within ΛCDM, these anisotropies have well-characterized statistical properties, the signal is principally from a thin spherical shell centered on the observer (the last scattering surface), and space-based observations nearly cover the full sky. The most generic signature of cosmic topology in the microwave background is pairs of circles with matching temperature and polarization patterns. No such circle pairs have been seen above noise in the WMAP or Planck temperature data, implying that the shortest non-contractible loop around the Universe through our location is longer than 98.5% of the comoving diameter of the last scattering surface. We translate this generic constraint into limits on the parameters that characterize manifolds with each of the nine possible non-trivial orientable Euclidean topologies, and provide a code which computes these constraints. In all but the simplest cases, the shortest non-contractible loop in the space can avoid us, and be shorter than the diameter of the last scattering surface by a factor ranging from 2 to at least 6. Further, this result implies that a broader range of manifolds is observationally allowed than widely appreciated. Probing these manifolds will require more subtle statistical signatures than matched circles, such as off-diagonal correlations of harmonic coefficients.

79 ASTRONOMY AND ASTROPHYSICS↗

A Psychoacoustic Test for Urban Air Mobility Vehicle Sound Quality

This paper describes a psychoacoustic test in the Exterior Effects Room (EER) at the NASA Langley Research Center. The test investigated the degree to which sound quality metrics (sharpness, tonality, etc.) are predictive of annoyance to notional sounds of Urban Air Mobility (UAM) vehicles (i.e., air taxis). A suite of 136 unique (4.6 second duration) UAM rotor noise stimuli was generated. These stimuli were based on aeroacoustic predictions of a NASA reference UAM quadrotor aircraft under two flight conditions. The synthesizer changed rotor noise parameters such as the blade passage frequency, the relative level of broadband self-noise, and the relative level of tonal motor noise. With loudness constant, the synthesis parameters impacted sound quality in a way that created a spread of predictors both in synthesizer parameters and in sound quality metrics. Forty subjects listened to the suite of UAM noise stimuli in the EER and judged each sound individually on a standard scale of annoyance. Additionally, a subset of the UAM noise stimuli were compared to a reference sound that varied in loudness. From these responses, the relative effect of changes in loudness or changes in other sound quality metrics on annoyance was evaluated. This paper covers background and motivation for the test, details of how the sound stimuli were generated, and details of the test design and execution. Test results investigate how sound quality may affect perceived annoyance to UAM vehicle noise, indicating the importance of sharpness, tonality, impulsiveness, and roughness on annoyance to UAM noise.

UAM↗

An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ + SPTpol Surveys

We report new measurements of millimeter-wave power spectra in the angular multipole range $2000 \le \ell \le 11,000$ (angular scales $5^\prime \gtrsim \theta \gtrsim 1^\prime$). By adding 95 and 150\,GHz data from the low-noise 500 deg$^2$ SPTpol survey to the SPT-SZ three-frequency 2540 deg$^2$ survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev-Zel'dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143\,GHz of $D^{\rm tSZ}_{3000} = 3.42 \pm 0.54~ \mu {\rm K}^2$ and a kinematic SZ (kSZ) power of $D^{\rm kSZ}_{3000} = 3.0 \pm 1.0~ \mu {\rm K}^2$. This is the first measurement of kSZ power at $\ge 3\,\sigma$. We study the implications of the measured kSZ power for the epoch of reionization, finding the duration of reionization to be $\Delta z_{re} = 1.0^{+1.6}_{-0.7}$ ($\Delta z_{re}< 4.1$ at 95% confidence), when combined with our previously published tSZ bispectrum measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the Impact of Radiation on Cameras and Robotic Perception - 19242

Robotic systems are increasingly used for inspection, maintenance, and disaster assistance for nuclear power plants. These robots utilize increasingly high levels of autonomy to operate in environments that are unsafe for humans to operate the robot in or require more precise control over the robot than a human can offer. In these cases, the robot must include perception and computation components to autonomously sense and navigate through the environment to fulfill its mission. This difficult task is complicated by radiation interfering with sensors' operation. The impact of this interference is largely unexplored, as existing works on radiation interference on sensors focus on estimating the incident radiation, rather than how it impacts a robotic system using the sensor. In this work, we seek to quantify and describe the impact of radiation on cameras, and how the radiation affects robotic performance. In this paper we study cameras that are suitable for small, lightweight unmanned aerial vehicles (UAVs) that are increasingly deployed to fly in confined areas in emergencies, where the surrounding environment is unsafe for workers to operate. These small UAVs lack the payload capacity to carry significant radiation shielding, so any onboard sensors will be affected by radiation. In the case of cameras, this radiation appears as noise in the camera imagery. This noise will interfere with the UAV's operation, by obscuring obstacles and interfering with localization and optical flow algorithms that detect detailed features in the environment. To date, there is a lack of information on how the radiation noise in the camera image impacts the overall robot system performance Existing work focuses on estimating the amount of incident radiation by measuring the corruption in the images. However, these works suffer several shortcomings for robotic systems. First, a robot must be able to successfully navigate its environment during a successful mission, and merely quantifying the amount of radiation noise in an image does not adequately explain how it may interfere with higher level navigation and perception tasks. Second, radiation estimation procedures rely on focusing the camera on a known and static background. This is unsuitable for robotic exploration tasks, where the robot frequently moves around an unknown environment that may be dynamically changing. Our work contains two contributions that address these shortcomings. First, we conduct a detailed analysis of the noise radiation causes in cameras by exposing cameras that are commonly used on UAVs [e.g., small form factor complementary metal-oxide-semiconductor (CMOS) cameras] to varying levels of radiation that may be present in emergency scenarios. From this exposure, we quantify not only how much noise is present, but quantify its appearance. By quantifying the appearance and amount of noise in a camera image, researchers can design mitigation strategies for the corruption, so that their robotic systems can operate in these challenging environments. Second, we demonstrate how to leverage this experimental data in robotic simulations. Using data from the first set of experiments allows us to test and verify the robots in simulation. Using simulators allows us to verify the robots will perform as expected during critical times without needing expensive test equipment or damaging valuable robot prototypes. Other researchers using robots for exploration of irradiated environments will benefit from our research by incorporating similar noise models in their research. 1 Southwest Research Institute{sup R} is a registered trademark of Southwest Research Institute in the United States and/or other countries. This will increase the reliability of robotic systems prior to deployment in emergency situations, which will in turn increase their effectiveness and speed the development of robots that would otherwise need expensive and time-consuming test procedures to validate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reconstructing small-scale lenses from the cosmic microwave background temperature fluctuations

Cosmic microwave background (CMB) lensing is a powerful probe of the matter distribution in the Universe. The standard quadratic estimator, which is typically used to measure the lensing signal, is known to be suboptimal for low-noise polarization data from next-generation experiments. In this paper, we explain why the quadratic estimator will also be suboptimal for measuring lensing on very small scales, even for measurements in temperature where this estimator typically performs well. Though maximum likelihood methods could be implemented to improve performance, we explore a much simpler solution, revisiting a previously proposed method to measure lensing that involves a direct inversion of the background gradient. An important application of this simple formalism is the measurement of cluster masses with CMB lensing. We find that directly applying a gradient inversion matched filter to simulated lensed images of the CMB can tighten constraints on cluster masses compared to the quadratic estimator. While the difference is not relevant for existing surveys, for future surveys it can translate to significant improvements in mass calibration for distant clusters, where galaxy lensing calibration is ineffective due to the lack of enough resolved background galaxies. Improvements can be as large as ~50 per cent for a cluster at z = 2 and a next-generation CMB experiment with 1 μK arcmin noise, and over an order of magnitude for lower noise levels. For future surveys, this simple matched filter or gradient inversion method approaches the performance of maximum likelihood methods, at a fraction of the computational cost.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative assessment of soil CO 2 concentration and stable carbon isotope for leakage detection at geological carbon sequestration sites

This paper presents a quantitative method to evaluate CO 2 concentration ([CO 2 ]) and stable carbon isotope ratio (δ 13 C) as indicators for leakage detection at a geological carbon sequestration site by combining use of field release tests and a numerical modeling approach. A numerical model was developed to simulate CO 2 dynamics by considering diffusion, dissolution in soil water, and soil respiration. The numerical model fits the background dynamics of [CO 2 ] (360 to 550 ppm) and δ 13 C (-16‰ to -6‰) well and reproduces fairly the overall trend observed during the CO 2 release test. The model was further applied to assess detection probability (DP) of [CO 2 ] and δ 13 C for leakage detection in terms of various factors, such as CO 2 leakage rate, background variations, δ 13 C of the CO 2 leaked, and the threshold value of signal-to-noise ratio. Modeling results suggest that δ 13 C may have a higher DP than [CO 2 ]. This study also shows that DP of δ 13 C for the IEA Weyburn project is close to 0, implying δ 13 C is inappropriate to be an indicator for CO 2 leakage at the site. Finally, the quantitative method developed can also be used to design a monitoring plan or strategy in a near-surface environment for geological carbon sequestration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations

The initial use of traveling waves (TW) for ion mobility (IM) separations using a structures for lossless ion manipulations (SLIM) employed an ion funnel trap (IFT) to accumulate ions from a continuous electrospray ionization source, and limited to injected ion populations of ~106 charges due to the onset of space charge effects in the trapping region. Additional limitations arise due to the loss of resolution for the injection of ions over longer periods (e.g. in extended pulses). In this work a new SLIM ‘flat funnel’ (FF) module has been developed and demonstrated to enable the accumulation of much larger ion populations and their injection for IM separations. Ion current measurements indicate a capacity of ~3.2×108 charges for the extended trapping volume, over an order of magnitude greater than the IFT. The orthogonal ion injection into a funnel shaped separation region can greatly reduce space charge effects during the initial IM separation stage, and the gradually reduced width of the path allows the ion packet to be increasingly compressed in the lateral dimension as the separation progresses, allowing e.g. efficient transmission through conductance limits or compatibility with subsequent ion manipulations. This work examined the TW, RF, and DC confining field SLIM parameters involved in ion accumulation, injection, transmission and separation in the FF IM module using both direct ion current and MS measurements. Wide m/z range ion transmission is demonstrated, along with significant increases in signal to noise (S/N) ratios due to the larger ion populations injected. Additionally, we observed a reduction in the chemical background, which was attributed to more efficient desolvation of solvent related clusters over the extended ion accumulation periods. The TW SLIM FF IM module is anticipated to be especially effective as a front end for long path SLIM IM separation modules.

Environmental Molecular Sciences Laboratory↗

Microstructural and optical analysis of superresolution phenomena due to Ge{sub 2}Sb{sub 2}Te{sub 5} thin films at blue light regime

Superresolution (SR) phenomena due to Ge{sub 2}Sb{sub 2}Te{sub 5} films were examined by combined analysis of the transmission electron microscopy (TEM) microstructures of the laser-irradiated films and the results from dynamic and static tests using blue lasers. A new finding was made that comprises a complementary case of the classical SR readout by Ge{sub 2}Sb{sub 2}Te{sub 5} film; an amorphous band instead of a closed aperture of melt in the crystalline background forms behind a moving laser but still produces a high SR signal. A complete carrier-to-noise-ratio curve of a SR-read-only memory employing Ge{sub 2}Sb{sub 2}Te{sub 5} may be derived from a nonlinear optical effect, specifically thermally assisted saturable absorption.

36 MATERIALS SCIENCE↗