Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Algorithm Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

An Open-Source Tool for Automated Power Grid Stress Level Prediction at Balancing Authorities

The behavior of modern power systems becomes more stochastic and dynamic, due to the increased penetration of variable generation, demand response, new power market structure, extreme weather conditions, contingencies, and unexpected events. It is critically important to predict potential system operational issues so that grid planners and operators can take preventive actions to mitigate the impact, e.g., lack of operational reserves. In this paper, an innovative software tool is presented to assist power grid operators in a balancing authority (BA) to predict the grid stress level over the next operating day. It periodically collects necessary information from public domain such as weather forecasts, electricity demand, and automatically estimates the stress levels on a daily basis. Advanced Neural Network and regression tree algorithms are developed as the prediction engines to achieve this goal. The tool has been tested on a few key balancing authorities that successfully predicates the growing system peak load and increased stress levels under extreme heat waves in the United States of America.

Berscheid, Alan P.↗

Gradient Coding With Iterative Block Leverage Score Sampling

Gradient coding is a method for mitigating straggling servers in a centralized computing network that uses erasure-coding techniques to distributively carry out first-order optimization methods. Randomized numerical linear algebra uses randomization to develop improved algorithms for large-scale linear algebra computations. In this study, we propose a method for distributed optimization that combines gradient coding and randomized numerical linear algebra. The proposed method uses a randomized ℓ 2 -subspace embedding and a gradient coding technique to distribute blocks of data to the computational nodes of a centralized network, and at each iteration the central server only requires a small number of computations to obtain the steepest descent update. The novelty of our approach is that the data is replicated according to importance scores, called block leverage scores, in contrast to most gradient coding approaches that uniformly replicate the data blocks. Furthermore, we do not require a decoding step at each iteration, avoiding a bottleneck in previous gradient coding schemes. We show that our approach results in a valid ℓ 2 -subspace embedding, and that our resulting approximation converges to the optimal solution.

97 MATHEMATICS AND COMPUTING↗

Applying Pattern Recognition to High-Resolution Images to Determine Cellular Signaling Status

Two frequently used tools to acquire high-resolution images of cells are scanning electron microscopy (SEM) and atomic force microscopy (AFM). The former provides a nanometer resolution view of cellular features rapidly and with high throughput, while the latter enables visualizing hydrated and living cells. In current practice, these images are viewed by eye to determine cellular status, e.g. activated versus resting. Automatic and quantitative data analysis is lacking. This work develops an algorithm of pattern recognition that works very effectively for AFM and SEM images. Using rat basophilic leukemia (RBL) cells, our approach creates a support vector machine (SVM) to automatically classify resting and activated cells. 10-fold cross-validation with cells that are known to be activated or resting gives a good estimate of the generalized classification results. The pattern recognition of AFM images achieves 100% accuracy, while SEM reaches 95.4% for our images as well as images published in prior literature. This outcome suggests that our methodology could become an important and frequently used tool for researchers utilizing AFM and SEM for structural characterization as well as determining cellular signaling status and function.

60 APPLIED LIFE SCIENCES↗

Computing an Optimal Entanglement Path with Throughput and Fidelity Considerations

Entanglement distribution is a core function of quantum networks essential for operations including teleportation, distributed quantum sensing, and multisite computation. Entanglement throughput and fidelity are two critical performance measures that depend on the quantum transmission along the links and swapping operations at the repeaters along the path. We study the problem of computing a end-to-end entanglement path that satisfies both fidelity and throughput requirements, leveraging qubit buffers at the nodes and considering the sequential swapping order. We show that the general problem of simultaneously satisfying both metrics to be NP-hard, and develop an algorithm to maximize throughput subject to a given fidelity threshold. We introduce the concepts of entanglement probability distribution and path domination and exploit them in the design of our algorithm. Extensive numerical results show that our algorithm can find optimal solutions in networks with thousands of nodes in less than a second. We also describe practical and possible implementation aspects of this algorithm in terms of devices and architecture support.

Xue, Guoliang [Arizona State University]↗

Dispatchability Maximization for Co-Optimized Energy and Reserve Dispatch With Explicit Reliability Guarantee

In this paper, we consider dispatchability as the set of all admissible nodal wind power injections that will not cause infeasibility in real-time dispatch (RTD). Our work reveals that the dispatchability of the affine policy based RTD (AF-RTD) is a polytope whose coefficients are linear functions of the generation schedule and the gain matrix of affine policy. Two mathematical formulations of the dispatchability maximized energy and reserve dispatch (DM-ERD) are proposed. The first one maximizes the distance from the forecast to the boundaries of the dispatchability polytope subject to the available production cost or reserve cost. Provided the forecast value and variance of wind power, the generalized Gauss inequality (GGI) is adopted to evaluate the probability of infeasible RTD without the exact probability distribution of wind power. Combining the first formulation and the GGI approach, the second one minimizes the total cost subject to a desired reliability level through dispatchability maximization. Efficient convex optimization based algorithms are developed to solve these two models. Different from the conventional robust optimization method, our model does not rely on the specific uncertainty set of wind generation and directly optimizes the uncertainty accommodation capability of the power system. The proposed method is also compared with the affine policy based robust energy and reserve dispatch (AR-ERD). Case studies on the PJM 5-bus system illustrate the proposed concept and method. Experiments on the IEEE 118-bus system demonstrate the applicability of our method on moderate sized systems and its scalability to large dimensional uncertainty.

17 WIND ENERGY↗

Calibrating Parameters of Power System Stability Models Using Advanced Ensemble Kalman Filter

With the ever increasing penetration of renewable energy, smart loads, energy storage, and new market behavior, today's power grid becomes more dynamic and stochastic, which may invalidate traditional study assumptions and pose great operational challenges. Thus, it is of critical importance to maintain good-quality models for secure and economic planning and real-time operation. Following the 1996 Western Systems Coordinating Council (WSCC) system blackout, North American Electric Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) in North America enforced a number of policies and standards to guide the power industry to periodically validate power grid models and calibrate poor parameters with the goal of building sufficient confidence in model quality. The PMU-based approach using online measurements without interfering with the operation of generators provides a low-cost alternative to meet NERC standards. This paper presents an innovative procedure and tool suites to validate and calibrate models based on a trajectory sensitivity analysis method and an advanced ensemble Kalman filter algorithm. The developed prototype demonstrates excellent performance in identifying and calibrating bad parameters of a realistic hydro power plant against multiple system events.

Huang, Renke (ORCID:0000000230947073)↗

A Machine Learning-based Reliability Evaluation Model for Integrated Power-Gas Systems

This article proposes a hybrid machine learning method for the reliability evaluation of integrated power-gas systems (IPGS) under the uncertain component failure probability distributions. The Random Forest (RF) method is designed to select important features to solve the insufficient quantity of data and the curse of dimensionality problems. The Extreme Gradient Boosting (XGBoost) regression algorithm is developed to quantify the relationship between the uncertain parameters and reliability metrics. Moreover, a ten-fold cross-validation method is employed to further improve the accuracy of the regression model. Simulation results on three test systems show that the proposed method can achieve high accuracy for the reliability evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Noise-Resilient Quantum Machine Learning for Stability Assessment of Power Systems

Transient stability assessment (TSA) is a cornerstone for resilient operations of todays interconnected power grids. This paper is a confluence of quantum computing, data science and machine learning to potentially address the power system TSA issue. Here, we devise a quantum TSA (QTSA) method to enable scalable and efficient data-driven transient stability prediction for bulk power systems, which is the first attempt to tackle the TSA issue with quantum computing. Our contributions are three-fold: 1) A high expressibility, low-depth (HELD) quantum circuit is designed for accurate and noise-resilient TSA; 2) A quantum natural gradient descent algorithm is developed for efficient HELD circuit training; 3) A systematical analysis on QTSAs performance under various quantum factors is per-formed. QTSA underpins a foundation of quantum-enabled and data-driven power grid stability analytics. It renders the intractable TSA straightforward and effortless in the Hilbert space, and therefore provides stability information for power system operations. Extensive experiments on quantum simulators and real quantum computers verify the accuracy, noise-resilience, scalability and universality of QTSA.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Operation of Soft Open Points in Active Distribution Networks with High Penetration of Photovoltaic Integration

Distributed generators (DGs) including photovoltaic panels (PVs) have been integrated dramatically in active distribution networks (ADNs). Due to the strong volatility and uncertainty, the high penetration of PV generation immensely exacerbates the conditions of voltage violation in ADNs. However, the emerging flexible interconnection technology based on soft open points (SOPs) provides increased controllability and flexibility to the system operation. For fully exploiting the regulation ability of SOPs to address the problems caused by PV, this paper proposes a robust optimization method to achieve the robust optimal operation of SOPs in ADNs. A two-stage adjustable robust optimization model is built to tackle the uncertainties of PV outputs, in which robust operation strategies of SOPs are generated to eliminate the voltage violations and reduce the power losses of ADNs. A column-and-constraint generation (C&CG) algorithm is developed to solve the proposed robust optimization model, which are formulated as second-order cone program (SOCP) to facilitate the accuracy and computation efficiency. Here, case studies on the modified IEEE 33-node system and comparisons with the deterministic optimization approach are conducted to verify the effectiveness and robustness of the proposed method.

14 SOLAR ENERGY↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery

Purpose: Monoscopic x-ray imaging with on-board kV devices is an attractive approach for real-time image guidance in modern radiation therapy such as VMAT or IMRT, but it falls short in providing reliable information along the direction of imaging x-ray. By effectively taking consideration of projection data at prior times and/or angles through a Bayesian formalism, the authors develop an algorithm for real-time and full 3D tumor localization with a single x-ray imager during treatment delivery. Methods: First, a prior probability density function is constructed using the 2D tumor locations on the projection images acquired during patient setup. Whenever an x-ray image is acquired during the treatment delivery, the corresponding 2D tumor location on the imager is used to update the likelihood function. The unresolved third dimension is obtained by maximizing the posterior probability distribution. The algorithm can also be used in a retrospective fashion when all the projection images during the treatment delivery are used for 3D localization purposes. The algorithm does not involve complex optimization of any model parameter and therefore can be used in a ''plug-and-play'' fashion. The authors validated the algorithm using (1) simulated 3D linear and elliptic motion and (2) 3D tumor motion trajectories of a lung and a pancreas patient reproduced by a physical phantom. Continuous kV images were acquired over a full gantry rotation with the Varian TrueBeam on-board imaging system. Three scenarios were considered: fluoroscopic setup, cone beam CT setup, and retrospective analysis. Results: For the simulation study, the RMS 3D localization error is 1.2 and 2.4 mm for the linear and elliptic motions, respectively. For the phantom experiments, the 3D localization error is < 1 mm on average and < 1.5 mm at 95th percentile in the lung and pancreas cases for all three scenarios. The difference in 3D localization error for different scenarios is small and is not statistically significant. Conclusions: The proposed algorithm eliminates the need for any population based model parameters in monoscopic image guided radiotherapy and allows accurate and real-time 3D tumor localization on current standard LINACs with a single x-ray imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor excursion outside of the gating window, which, for our study group, is mainly caused by baseline shift, i.e., the change in general trend of the motion curve during extended period of treatment time. Conclusions: The dose deviation in PTV and CTV due to target motion is not always negligible in gated SBRT. Although CTVs are covered sufficiently with prescribed dose in most cases, some are on the verge of underdose due to large tumor excursion caused by factors such as baseline shift.

60 APPLIED LIFE SCIENCES↗

Actively triggered 4d cone-beam CT acquisition

Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7–2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans.Conclusions: This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-95: Delivery Time Estimator

Purpose: The development and testing of a tool for the inclusion of delivery time as a parameter in plan optimization. Methods: We developed an algorithm that estimates the time required for the machine and personnel movements required to deliver a treatment plan on a linear accelerator. We included dose rate, leaf motion, collimator motion, gantry motion, and couch motions (including time to enter the room to rotate the couch safely). Vault-specific parameters to account for time to enter and perform couch angle adjustments were also included. This algorithm works for static, step and shoot IMRT, and VMAT beams photon beams and for fixed electron beams. This was implemented as a script in our treatment planning system. We validated the estimator against actual recorded delivery time from our R and V system as well as recorded times from our IMRT QA delivery. Results: Data was collected (Figure 1) for 12 treatment plans by examining the R and V beam start times, and by manually timing the QA treatment for a reference, but the QA measurements were only significant to the nearest minute. The average difference between the estimated and R and V times was 15%, and 11% when excluding the major outliers. Outliers arose due to respiratory aides and gating techniques which could not be accounted for in the estimator. Conclusion: Non-mechanical factors such as the time a therapist needs to walk in and out of the room to adjust the couch needed to be fine-tuned and cycled back into the algorithm to improve the estimate. The algorithm has been demonstrated to provide reasonable and useful estimates for delivery time. This estimate has provided a useful additional input for clinical decision-making when comparing several potential radiation treatment options.

07 ISOTOPE AND RADIATION SOURCES↗

WE-E-17A-06: Assessing the Scale of Tumor Heterogeneity by Complete Hierarchical Segmentation On MRI

Purpose: In many cancers, intratumoral heterogeneity exists in vascular and genetic structure. We developed an algorithm which uses clinical imaging to interrogate different scales of heterogeneity. We hypothesize that heterogeneity of perfusion at large distance scales may correlate with propensity for disease recurrence. We applied the algorithm to initial diagnosis MRI of rhabdomyosarcoma patients to predict recurrence. Methods: The Spatial Heterogeneity Analysis by Recursive Partitioning (SHARP) algorithm recursively segments the tumor image. The tumor is repeatedly subdivided, with each dividing line chosen to maximize signal intensity difference between the two subregions. This process continues to the voxel level, producing segments at multiple scales. Heterogeneity is measured by comparing signal intensity histograms between each segmented region and the adjacent region. We measured the scales of contrast enhancement heterogeneity of the primary tumor in 18 rhabdomyosarcoma patients. Using Cox proportional hazards regression, we explored the influence of heterogeneity parameters on relapse-free survival (RFS). To compare with existing methods, fractal and Haralick texture features were also calculated. Results: The complete segmentation produced by SHARP allows extraction of diverse features, including the amount of heterogeneity at various distance scales, the area of the tumor with the most heterogeneity at each scale, and for a given point in the tumor, the heterogeneity at different scales. 10/18 rhabdomyosarcoma patients suffered disease recurrence. On contrast-enhanced MRI, larger scale of maximum signal intensity heterogeneity, relative to tumor diameter, predicted for shorter RFS (p=0.05). Fractal dimension, fractal fit, and three Haralick features did not predict RFS (p=0.09-0.90). Conclusion: SHARP produces an automatic segmentation of tumor regions and reports the amount of heterogeneity at various distance scales. In rhabdomyosarcoma, RFS was shorter when the primary tumor exhibited larger scale of heterogeneity on contrast-enhanced MRI. If validated on a larger dataset, this imaging biomarker could be useful to help personalize treatment.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-J-126: An Online Replanning Method for FFF Beams Without Couch Shift

Purpose: In a situation that couch shift for patient positioning is not preferred or prohibited (e.g., MR-Linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening filter free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here we propose a new 2-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online steps. The offline step is to create a series of pre-shifted plans (PSP) obtained by a so called “warm start” optimization (starting optimization from the original plan, rather from scratch) at a series of isocenter shifts with fixed distance (e.g. 2 cm, at x,y,z = 2,0,0 ; 2,2,0 ; 0,2,0; …;− 2,0,0). The PSPs all have the same number of segments with very similar shapes, since the warm-start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated, and instantaneously fast (no optimization or dose calculation needed). The previously-developed SAM algorithm is then applied for daily deformation. We tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusion: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation requiring no additional time from the SAM process. This research was supported by Elekta inc. (Crawley, UK)

60 APPLIED LIFE SCIENCES↗