Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Access Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Nuclear Data Management and Analysis System Plan

The United States Department of Energy Advanced Reactor Technologies Program was formed in Fiscal Year 2015 and encompasses the Next Generation Nuclear Plant Project and Very High Temperature Reactor (VHTR) Program as they were known previously. The VHTR Program was created to support design and licensing of the first VHTR nuclear plant. Data created for and used by the program must be qualified for use, stored in a readily accessible electronic form, categorized to assure the correct data are used, and controlled to prevent data corruption or inadvertent changes. The Nuclear Data Management and Analysis System was designed to support the data needs of the VHTR Program, at the time and now the Advanced Reactor Technologies Program. Since its inception, use of the Nuclear Data Management and Analysis System has expanded to support additional projects and programs with similar requirements for control, analysis, and availability of large data sets.

99 GENERAL AND MISCELLANEOUS↗

Post-closure program streamlining at the Nevada national security site - 15290

More than 200 sites on the Nevada National Security Site (NNSS), Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR) have been closed in place. At these sites, contamination has been left in place, and protection of human health, safety, and the environment is ensured through the establishment of use restrictions (URs). Post-closure requirements were initially established in the Closure Report (CR) for each site and include a variety of inspection, monitoring, maintenance, and reporting commitments. Post-closure requirements and site controls (fences, monuments, soil covers, and postings) may vary depending on site location, accessibility, land use scenario, and the nature of contaminants left in place. Corrective Action Sites (CASs) on the NNSS, NTTR, and TTR have been identified for closure under the Federal Facility Agreement and Consent Order (FFACO), which was signed in 1996. Over 1,900 CASs have been closed under the framework of the FFACO, and more than 200 of those have URs. Many post-closure requirements have been modified over time. In addition, because the scope of the program has spanned almost 20 years, the post-closure requirements have varied due to changing strategies and expectations. Because of the number of sites closed over the course of the program, post-closure requirements are found in hundreds of closure documents, addendums, errata sheets, Records of Technical Change, inspection reports, permit modifications, and correspondence. Furthermore, resources such as personnel and funding necessary to conduct the post-closure program have diminished, while computer capabilities and configuration control principles have improved since closure activities under the FFACO began. Because of these factors, to effectively manage the post-closure program, ensure that all commitments are being met, and improve the ease of identifying the most current post-closure requirements for each UR, the current requirements for every use-restricted site under the purview of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office will be consolidated into a single Post-Closure Plan. The Consolidated Post-Closure Plan will also outline a strategy and present possible criteria that may be used for future evaluation of post-closure requirements. Continual assessment of the post-closure program will ensure that the post-closure requirements for URs across the NNSS, NTTR, and TTR are consistently justifiable and sufficient to protect site workers, the public, and the environment while increasing efficiency. Future changes to post-closure requirements and justification for those changes will be recorded in revisions to the Consolidated Post-Closure Plan. This process will provide a comprehensive, consistent, and streamlined method for evaluation of post-closure requirements and implementation of changes. (authors)

54 ENVIRONMENTAL SCIENCES↗

Achievements of actively controlled divertor detachment compatible with sustained high confinement core in DIII-D and EAST

The compatibility of efficient divertor detachment with high-performance core plasma is vital to the development of magnetically controlled fusion energy. The joint research on the EAST and DIII-D tokamaks demonstrates successful integration of divertor detachment with excellent core plasma confinement quality, a milestone towards solving the critical plasma–wall-interaction (PWI) issue and core-edge integration for ITER and future reactors. In EAST, actively controlled partial detachment with T et,div ~ 5 eV around the strike point and H 98 > 1 in different H-mode scenarios including the high β P H-mode scenario have been achieved with ITER-like tungsten divertor, by optimizing the detachment access condition and performing detailed experiments for core-edge integration. For active long-pulse detachment feedback control, a 30 s H-mode operation with detachment-control duration being 25 s has been successfully achieved in EAST. DIII-D has achieved actively controlled fully detached divertor with low plasma electron temperature (T et,div ≤ 5 eV across the entire divertor target) and low particle flux (degree of detachment, DoD > 3), simultaneously with very high core performance (β N ~3, β P > 2 and H 98 ~ 1.5) in the high βP scenario being developed for ITER and future reactors. The high-β P high confinement scenario is characterized by an internal transport barrier (ITB) at large radius and a weak edge transport barrier (ETB, or pedestal), which are synergistically self-organized. Both the high-β P scenario and impurity seeding facilitate divertor detachment. The detachment access leads to the reduction of ETB, which facilitates the development of an even stronger ITB at large radius in the high β P scenario. Thus, this strong large radius ITB enables the core confinement improvement during detachment. In conclusion, these significant joint DIII-D and EAST advances on the compatibility of high confinement core and detached divertor show a great potential for achieving a high-performance core plasma suitable for long-pulse operation of fusion reactors with controllable steady-state PWIs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Network Randomization and Dynamic Defense for Critical Infrastructure Systems

Critical Infrastructure control systems continue to foster predictable communication paths, static configurations, and unpatched systems that allow easy access to our nation's most critical assets. This makes them attractive targets for cyber intrusion. We seek to address these attack vectors by automatically randomizing network settings, randomizing applications on the end devices themselves, and dynamically defending these systems against active attacks. Applying these protective measures will convert control systems into moving targets that proactively defend themselves against attack. Sandia National Laboratories has led this effort by gathering operational and technical requirements from Tennessee Valley Authority (TVA) and performing research and development to create a proof-of-concept solution. Our proof-of-concept has been tested in a laboratory environment with over 300 nodes. The vision of this project is to enhance control system security by converting existing control systems into moving targets and building these security measures into future systems while meeting the unique constraints that control systems face.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Substrate recognition and catalysis by GH47 α-mannosidases involved in Asn-linked glycan maturation in the mammalian secretory pathway

Maturation of Asn-linked oligosaccharides in the eukaryotic secretory pathway requires the trimming of nascent glycan chains to remove all glucose and several mannose residues before extension into complex-type structures on the cell surface and secreted glycoproteins. Multiple glycoside hydrolase family 47 (GH47) α-mannosidases, including endoplasmic reticulum (ER) α-mannosidase I (ERManI) and Golgi α-mannosidase IA (GMIA), are responsible for cleavage of terminal α1,2-linked mannose residues to produce uniquely trimmed oligomannose isomers that are necessary for ER glycoprotein quality control and glycan maturation. ERManI and GMIA have similar catalytic domain structures, but each enzyme cleaves distinct residues from tribranched oligomannose glycan substrates. The structural basis for branch-specific cleavage by ERManI and GMIA was explored by replacing an essential enzyme-bound Ca 2+ ion with a lanthanum (La 3+ ) ion. This ion swap led to enzyme inactivation while retaining high-affinity substrate interactions. Cocrystallization of La 3+ -bound enzymes with Man9GlcNAc 2 substrate analogs revealed enzyme–substrate complexes with distinct modes of glycan branch insertion into the respective enzyme active-site clefts. Both enzymes had glycan interactions that extended across the entire glycan structure, but each enzyme engaged a different glycan branch and used different sets of glycan interactions. Additional mutagenesis and time-course studies of glycan cleavage probed the structural basis of enzyme specificity. Here, the results provide insights into the enzyme catalytic mechanisms and reveal structural snapshots of the sequential glycan cleavage events. The data also indicate that full steric access to glycan substrates determines the efficiency of mannose-trimming reactions that control the conversion to complex-type structures in mammalian cells.

59 BASIC BIOLOGICAL SCIENCES↗

DEVELOPMENT OF GLASS MATRICES FOR HLW RADIOACTIVE WASTES

Vitrification is currently the most widely used technology for the treatment of high level radioactive wastes (HLW) throughout the world. Most of the nations that have generated HLW are immobilizing in either borosilicate glass or phosphate glass. One of the primary reasons that glass has become the most widely used immobilization media is the relative simplicity of the vitrification process, e.g. melt waste plus glass forming frit additives and cast. A second reason that glass has become widely used for HLW is that the short range order (SRO) and medium range order (MRO) found in glass atomistically bonds the radionuclides and governs the melt properties such as viscosity, resistivity, sulphate solubility. The molecular structure of glass controls contaminant/radionuclide release by establishing the distribution of ion exchange sites, hydrolysis sites, and the access of water to those sites. The molecular structure is flexible and hence accounts for the flexibility of glass formulations to waste variability. Nuclear waste glasses melt between 1050-1150 C which minimizes the volatility of radioactive components such as Tc{sup 99}, Cs{sup 137}, and I{sup 129}. Nuclear waste glasses have good long term stability including irradiation resistance. Process control models based on the molecular structure of glass have been mechanistically derived and have been demonstrated to be accurate enough to control the world's largest HLW Joule heated ceramic melter in the US since 1996 at 95% confidence.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flight control augmentation for AFT CG launch vehicles

The Space Shuttle was only the first step in achieving routine access to space. Recently, the NASA Marshall Space Flight Center (MSFC) has been studying a whole spectrum of new launch vehicles (L/V's) for space transportation. Some of these could transport components of the Space Station to orbit, and some could take us to Mars and beyond to boldly expand our frontiers of knowledge. In all our future launch vehicle (L/V) designs, decreasing the structural weight will always be of great concern. This is tantamount to increased payload capability, which in turn means reduced cost-per-pound to orbit. One very significant increase in payload capability has been defined. In a L/V recently studied at MSFC it has been shown that a sizable weight savings can be realized by a rearrangement of the internal propellant tanks. Studies have been conducted both at MSFC and at Martin Marietta Corporation, maker of the Space Shuttle External Tank (ET) which show that a very substantial weight can be saved by inverting the relative positions of the liquid hydrogen (LH2) and the liquid oxygen (LOX) propellant tanks in a particular L/V studied. As the vehicle sits on the launch pad, in the conventional configuration the heavier LOX tank is located on top of the lighter LH2. This requires a heavy structural member between the two tanks to prevent the lighter LH2 tank from being crushed. This configuration also requires large, long, and even drag producing LOX feed lines running the length of the vehicle on the exterior fuselage. If the relative position of the propellant tanks is inverted, both the heavy structural separation member and the long LOX feed lines could be deleted. While the structures community at MSFC was elated with this finding, the LOX tank aft configuration gave the vehicle an aft center-of-gravity (cg) location which surfaced controllability concerns. In the conventional configuration the L/V is controlled in the ascent trajectory by the gimballing of its rocket engines. Studies have been conducted at MSFC which showed that the resulting aft cg configured L/V would not be adequately controllable with the engine gimballing alone.

Barret, Chris↗

Prostate Artery Embolization for Complete Urinary Outflow Obstruction Due to Benign Prostatic Hypertrophy

BackgroundWe aimed to evaluate the effectiveness of PAE in weaning of catheter and relieving obstructive urinary symptoms in patients with acute urinary retention (AUR) due to benign prostatic hypertrophy (BPH) and failed trial without catheter (TWOC).Materials and MethodsIn this prospective study approved by the institutional review board, a signed informed consent was obtained. Eighteen consecutive patients with AUR due to BPH and failed TWOC were recruited. Nineteen consecutive patients with BPH but without AUR were recruited as a control. Patients with CTA evidence of arterial occlusion or significant stenosis along the prostate artery access path were excluded. PAE was performed using microspheres (100–300 μm diameter). Outcome assessment included successful weaning of catheter in 2 weeks, procedure-related complications, change of symptomatology and urodynamic findings at 1 month as compared to baseline, percent non-perfused prostate volume, and prostate volume reduction on MRI at 2 weeks.ResultsTwo patients in the study group and four in the control group were excluded due to arterial pathology. Embolization of bilateral prostate arteries was achieved in all patients in both the groups (100%). There was no complication. The catheter was successfully weaned in 87.5% (14/16) of patients within 14 days in the treatment group. There was no significant difference in patient demographics, prostate characteristics, and all outcome assessment parameters between both the groups.ConclusionsPAE was probably safe and effective in weaning of catheter and relieving obstructive urinary symptoms in patients due to BPH, with treatment outcomes comparable to those without AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electric-field control of tri-state phase transformation with a selective dual-ion switch

Materials can be transformed from one crystalline phase to another by using an electric field to control ion transfer, in a process that can be harnessed in applications such as batteries, smart windows and fuel cells. Increasing the number of transferrable ion species and of accessible crystalline phases could in principle greatly enrich material functionality. However, studies have so far focused mainly on the evolution and control of single ionic species (for example, oxygen, hydrogen or lithium ions). In this paper, we describe the reversible and non-volatile electric-field control of dual-ion (oxygen and hydrogen) phase transformations, with associated electrochromic and magnetoelectric effects. We show that controlling the insertion and extraction of oxygen and hydrogen ions independently of each other can direct reversible phase transformations among three different material phases: the perovskite SrCoO 3-δ , the brownmillerite SrCoO 2.5 , and a hitherto-unexplored phase, HSrCoO 2.5 . By analysing the distinct optical absorption properties of these phases, we demonstrate selective manipulation of spectral transparency in the visible-light and infrared regions, revealing a dual-band electrochromic effect that could see application in smart windows. Moreover, the starkly different magnetic and electric properties of the three phases—HSrCoO 2.5 is a weakly ferromagnetic insulator, SrCoO 3-δ is a ferromagnetic metal, and SrCoO 2.5 is an antiferromagnetic insulator—enable an unusual form of magnetoelectric coupling, allowing electric-field control of three different magnetic ground states. Finally, these findings open up opportunities for the electric-field control of multistate phase transformations with rich functionalities.

36 MATERIALS SCIENCE↗

Protecting Accelerator Control Systems in the Face of Sophisticated Cyber Attacks

Cyber security for industrial control systems has received significant attention in the past two years. The news coverage of the Stuxnet attack, believed to be targeted at the control system for a uranium enrichment plant, brought the issue to the attention of news media and policy makers. This has led to increased scrutiny of control systems for critical infrastructure such as power generation and distribution, and industrial systems such as chemical plants and petroleum refineries. The past two years have also seen targeted network attacks aimed at corporate and government entities including US Department of Energy National Laboratories. Both of these developments have potential repercussions for the control systems of particle accelerators. The need to balance risks from potential attacks with the operational needs of an accelerator present a unique challenge for the system architecture and access model.

02 PETROLEUM↗

Considerations for recovery of large areas of a nuclear facility for re-use - 15147

This paper highlights a number of factors an organization might consider for recovery of a facility, using a successful example from the UK. In 2013 a power failure led to the shutdown of the ventilation system that caused loose contamination to be deposited over large sections of man-accessible areas of plant after the evacuation of personnel. The successful initiation of emergency Command and Control arrangements during the Response phase, saw several key responders brought together to offer technical direction across many disciplines. The actions of the Command and Control unit prevented any further spread contamination to other areas of the facility and any external release. This enabled the return of the plant to an operational status which forms an important mission enabler for the site hazard reduction programme. Intervention at an early stage during the Response phase of the incident saw the cessation of traditional dilute chemical wet decontamination approach that would otherwise leave a legacy of slow leaching contamination; to that of containment and ultimate removal of loose contamination using strippable coatings. Doing so established a more rapid and reliably 'clean' access or pathway into the plant to establish the full extent of the situation. The scale and scope of the decontamination requirement was steadily revealed through a number of controlled re-entries to the plant. A number of other techniques were considered and employed to address the different areas making use of available plant resources to deliver the successful 'self-help' recovery of the plant using multi-disciplinary teams. As Response switched to Recovery, it was important to set out and agree which strategic option should be adopted to return the facility to normal operation. Equally, it was necessary to verify which equipment had been affected by the power outage and repair as required. Furthermore, equipment with designated safety functions had to be maintained alongside the Recovery activities. A careful balance of priorities demanded an unparalleled depth of plant knowledge to address this, whilst still keeping site and external stakeholders informed. The engagement by the plant workforce to take on the decontamination challenge to enable recovery of their plant supported by other teams formed a critical step in the speed of recovery. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The US National Transonic Facility, NTF

The construction of the National Transonic Facility was completed in September 1982 and the start-up and checkout of tunnel systems were performed over the next two years. In August 1984, the Operational Readiness Review (ORR) was conducted and the facility was declared operational for final checkout of cryogenic instrumentation and control systems, and for the aerodynamic calibration and testing to commence. Also, the model access system for the cryogenic mode of operation would be placed into operation along with tunnel testing. Since the ORR, a host of operating problems resulting from the cryogenic environment were identified and solved. These range from making mechanical and electrical systems functional to eliminating temperature induced model vibration to coping with the outgassing of moisture from the thermal insulation. Additionally, a series of aerodynamic tests have demonstrated data quality and provided research data on several configurations. Some of the more significant efforts are reviewed since the ORR and the NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality are summarized.

Bruce, Walter E., Jr.↗

Monolithic Kerr and electro-optic hybrid microcombs

Microresonator-based soliton generation promises chip-scale integration of optical frequency combs for applications spanning from time keeping to frequency synthesis. Access to the soliton repetition rate is a prerequisite for those applications. While miniaturized cavities harness Kerr nonlinearity and enable terahertz soliton repetition rates, such high rates are not amenable to direct electronic detection. Here, we demonstrate hybrid Kerr and electro-optic microcombs using a lithium niobate thin film that exhibits both Kerr and Pockels nonlinearities. By interleaving the high-repetition-rate Kerr soliton comb with the low-repetition-rate electro-optic comb on the same waveguide, wide Kerr soliton mode spacing is divided within a single chip, allowing for direct electronic detection and feedback control of the soliton repetition rate. Our work establishes an integrated approach to electronically access terahertz solitons, paving the way for building chip-scale referenced comb sources.

42 ENGINEERING↗

A Comparison of Control Allocation Methods in the Presence of Parametric Model Uncertainty

When allocating redundant effectors to virtual control commands, linear (generalized inverse) allocators have historically been used on aircraft and spacecraft. While simple to implement, generalized inverses are unable to realize a significant portion of the attainable moments. To address this drawback, the control allocation problem can also be formulated as a linear programming or quadratic programming problem and solved using convex optimization based solvers. These approaches have been shown to access a larger set of attainable moments, however, little work has been done to understand the performance of convex optimization-based control allocation in the presence of parametric model uncertainty. This paper seeks to compare the performance of several control allocation approaches, including two forms of generalized inverse allocators, the pseudo inverse and minimum-variance, and the linear programming and quadratic programming approach in the presence of parametric model uncertainty. The performance of these four allocators were tested on an aircraft model in the presence of realistic parametric model uncertainty and the convex optimization approaches were shown to outperform the generalized inverses.

Luke J Miller↗

Beyond Control Centers

For NASA's Resource Prospector (RP) Lunar Rover Mission, we are moving away from a control center concept, to a fully distributed operation utilizing control nodes, with decision support from anywhere via mobile devices. This operations concept will utilize distributed information systems, notifications, mobile data access, and optimized mobile data display for off-console decision support. We see this concept of operations as a step in the evolution of mission operations from a central control center concept to a mission operations anywhere concept. The RP example is part of a trend, in which mission expertise for design, development and operations is distributed across countries and across the globe. Future spacecraft operations will be most cost efficient and flexible by following this distributed expertise, enabling operations from anywhere. For the RP mission we arrived at the decision to utilize a fully distributed operations team, where everyone operates from their home institution, based on evaluating the following factors: the requirement for physical proximity for near-real time command and control decisions; the cost of distributed control nodes vs. a centralized control center; the impact on training and mission preparation of flying the team to a central location. Physical proximity for operational decisions is seldom required, though certain categories of decisions, such as launch abort, or close coordination for mission or safety-critical near-real-time command and control decisions may benefit from co-location. The cost of facilities and operational infrastructure has not been found to be a driving factor for location in our studies. Mission training and preparation benefit from having all operators train and operate from home institutions.

Operations↗

A Prediction of Uranium(VI) Diffusion in Montmorillonite at Various Chemical Solution Conditions

Most nuclear waste disposal options include compacted bentonite, predominately consisting of montmorillonite clay, as part of a barrier system to minimize contaminant mobility. Uranium (U) is the primary element in spent nuclear fuel, and a potential contaminant of water resources. Uranium sorption onto clay and its slow diffusive transport away from waste canisters are expected to limit U(VI) mobility, and possibly also control nuclear fuel degradation rates based on mass action considerations. A prediction of U(VI) diffusion in these systems is complicated by two main factors: (1) the complex mineralogical structure of montmorillonite clay, leading to two types of clay porosities and surface sites, and (2) the dependence of U(VI) sorption on U(VI) solution speciation and the specific chemical system conditions. For instance, depending on pH and ionic strength, U(VI) may sorb onto montmorillonite due to weak ion exchange reactions or the formation of stable surface complexes. Furthermore, in contrast to conventional porous media, U(VI) diffusion in montmorillonite is not only limited by contaminant sorption, but also by a (potential) lack of access to the full clay porosity for some U(VI) solution species. For instance, at the high degrees of clay compaction expected in future barrier systems, the partial or full exclusion of U(VI) from negatively-charged clay interlayer spaces may substantially decrease U(VI) fluxes. In this modeling study, we specifically investigated how the charge of U(VI) solution species affects U(VI) sorption and diffusion behavior. For this purpose, we first simplified complex chemical solution speciation diagrams to charge speciation diagrams. Then, we coupled an existing U(VI) surface complexation model (Tournassat et al., Geochim. Cosmochim. Acta, 2018) with an analytical solution of the diffusion equation to simulate U(VI) mobility in lab-scale through-diffusion experiments for various chemical conditions. Our results suggest that there are two important parameters that govern U(VI) diffusion in these systems. First, U(VI) surface complexation on clay edge surfaces leads to contaminant retardation. On the field scale, this will determine how early a plume may cross site boundaries and pose risks to drinking water resources. Second, the degree of access of U(VI) solution species to diffuse layers in clay interlayer spaces largely controls U(VI) diffusive fluxes. In the field, this parameter will govern the level of U(VI) concentrations that can be expected in contaminated waters.

Pistorino, Jonathan C.↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗