Cavity Production and Testing of the First C75 Cryomodule for CEBAF

The CEBAF cryomodule rework program was updated over the last few years to increase the energy gain of refurbished cryomodules to 75 MeV. The concept recycles the waveguide end-groups from original CEBAF cavities fabricated in the 1990s and replaces the five elliptical cells in each with a new optimized cell shape fabricated from large-grain, ingot Nb material. Eight cavities were fabricated at Research Instruments, Germany, and two cavities were built at Jefferson Lab. Each cavity was processed by electropolishing and tested at 2.07 K. The best eight cavities were assembled into ’cavity pairs’ and re-tested at 2.07 K, before assembly into the cryomodule. All but one cavity in the cryomodule were within 10% of the target accelerating gradient of 19 MV/m with a quality factor of 8·10⁹. The performance limitations were field emission and multipacting.

Ciovati, G.↗

Real-Time Drilling Optimization System for Improved Overall Rate of Penetration and Reduced Cost Per Foot in Geothermal Drilling

The key to success in geothermal drilling is economic feasibility, and a major cost in the development of geothermal resources is the actual drilling of the wells. In this project, a real-time drilling optimization system for geothermal drilling was developed. The system couples three individual components while drilling. The first component is a drill stem vibration analysis model, the second is Mechanical Specific Energy (MSE) analyses, and the third is a detailed PDC Rate of Penetration (ROP) drill bit model for optimum RPM and WOB combinations. The benefit of the coupled system is that the range of WOB and RPM could be selected to avoid drill stem vibrations. Secondly, MSE is used as an efficiency measure and the detailed PDC drill bit model ensures the drill bit does not endure temperatures that exceed the temperature at which the PDC cutters experience accelerated wear. The new detailed PDC bit model is based on rock/bit interaction that physically tracks the PDC cutter wear flats as the bit drills ahead giving the capability to calculate the temperature being generated underneath the worn cutters to better advise on operational parameters to avoid accelerated cutter wear and failure and to ensure that operational parameters are applied so that overall ROP is maximized. By combining the drill stem vibrations and the detailed PDC bit cutter wear and “safe” non-accelerated cutter wear temperature and optimum ranges of operating parameters, it results in higher ROP and lower cost drilling. Single cutter PDC testing performed in different lithologies at Sandia was utilized to verify the PDC cutter forces and depth of cut for new and worn cutters. Based on single cutter PDC temperature modeling, verification using single cutter data from the testing done by National Oilwell Varco (NOV) was performed. Sandia’s Hard-Rock Drilling Facility (HRDF) was utilized to test different drill bit configurations with different cutter designs and wear status with different induced modes of vibration to obtain the critical bit RPM/WOB ranges resulting in ineffective drilling and low ROP. The collected test data were further used to verify and calibrate the full hole PDC ROP model that was developed based on single cutter interaction data. A full coupled drill stem vibration model was formulated and verified with geothermal field data from the Chocolate Mountain Aerial Gunnery Range (CMAGR). A graphical user interface (GUI) was developed using Tkinter library in the computer programming language Python, which integrates all the developed models in one system. The developed system consists mainly of the PDC ROP model, PDC bit wear model, PDC cutter temperature model, Mechanical Specific Energy (MSE) model, and drillstring vibration model integrated into one system. The developed system can be used for both, post well analysis and real-time optimization using different criteria such as ROP maximization or MSE minimization. The software uses Differential Evolution Algorithm (DEA) to find optimum values for operational parameters based on last foot drilled while avoiding the drillstring vibration and cutter temperature critical operating parameters.

15 GEOTHERMAL ENERGY↗

Cavity Production and Testing of the First C75 Cryomodule for CEBAF

The CEBAF cryomodule rework program was updated over the last few years to increase the energy gain of refurbished cryomodules to 75 MeV. The concept recycles the waveguide end-groups from original CEBAF cavities fabricated in the 1990s and replaces the five elliptical cells in each with a new optimized cell shape fabricated from large-grain, ingot Nb material. Eight cavities were fabricated at Research Instruments, Germany, and two cavities were built at Jefferson Lab. Each cavity was processed by electropolishing and tested at 2.07 K. The best eight cavities were assembled into ’cavity pairs’ and re-tested at 2.07 K, before assembly into the cryomodule. All but one cavity in the cryomodule were within 10% of the target accelerating gradient of 19 MV/m with a quality factor of 8·10⁹. The performance limitations were field emission and multipacting.

Ciovati, G.↗

Low Cost High-Performance HRE-Free 3-in-1 Electric Drive Unit

The project team completed work to expand upon American Axle & Manufacturing’s (AAM) baseline technology and develop a high-speed, AC induction electric drive unit (EDU) with total direct-oil-cooling and integrated power electronics. The project accelerated advancements in EDU technology by allowing AAM to build upon the progress made in developing the underlying baseline technologies. The following seven improvements to AAM’s baseline technology were implemented in this research and development program: 1) Increased speed (30k RPM) AC induction motor, 2) Silver-sintering of discrete silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFET) to heat sinks, 3) Electrically insulated rotor bars, 4) Optimized lamination steel, 5) EDU-integrated 650VDC inverter package, 6) Over-molded stator with molded liners, and 7) 650VDC power-dense stator design. The successful development of the technology resulted in a meaningful cost reduction for EDU systems in the market. Coupled with falling battery system costs, lower EDU costs will likely accelerate the market acceptance and related production scaling of battery electric vehicles. The objective of this project was to research, develop, and test a Heavy Rare Earth (HRE)-free 3-In-1 electric drive unit (EDU) that has class leading power density and cost. The key technologies to be developed were anticipated to meet or exceed the Department of Energy (DOE) targets of a cost ≤ $\$$7/kilowatt (kW), power density ≥ 12 kW/liter, and operating voltage ≥ 600 VDC.

33 ADVANCED PROPULSION SYSTEMS↗

Diagnostics, Prognostics, and Optimization for Lithium-Ion Battery Systems

Health management of lithium-ion battery systems presents a host of challenges due to their complex physics, large numbers of components, and a wide variety of degradation behaviors across different battery types. Dr. Paul Gasper will present on research from the Electrochemical Energy Storage Group on Lithium-ion battery diagnostics, prognostics, and optimization. Diagnostics research, including state-estimation via machine-learning from electrochemical impedance spectroscopy and DC pulses as well as continuous state-estimation via Kalman filters, will highlight the ongoing challenges for accurately measuring the state of batteries without performing time-consuming characterization tests. NLR's industry-recognized battery prognostics work, which predicts real-world battery degradation by identifying degradation rate models from accelerated aging data using statistical modeling and machine-learning, will be used to demonstrate the critical impact of battery controls, thermal management, and operating strategy on durability and lifetime. Finally, the use of prognostic models for financial or lifetime optimization will be discussed.

25 ENERGY STORAGE↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluid dynamic simulation and analysis of water-cooling systems for the Electron-Ion Collider

The Electron-Ion Collider is the newest large-scale project at Brookhaven National Laboratory. The collider’s purpose is to provide further advancements in the knowledge of the universe’s origin by accelerating particles near the speed of light. Our project for this 3.8 km ring was to create a thermal hydraulic steady-state simulation design of the water-cooling system to be cost-effective and energy efficient, as envisioned by Charlie Foltz, the EIC Infrastructure Division Director. The system would include a supply and return header, which cools several thousand components of the ring. The water would then be returned and cooled down using a system of cooling towers and plate and frame heat exchangers. Due to the size of the system and the complexity of the network analysis, a fluid dynamic simulation software, AFT Fathom, was used. Since previous methods of maintaining systems relied on building upon smaller real-life models and implementing empirical data, this flow model was unique and first of a kind in the domain of accelerator design, construction and operation. Therefore, our hydraulic team piloted a new method to perform network analysis on a large scale cooling system. We successfully created several test scenarios for system behavior in a shorter time compared to the method of performing hand calculations. Cooling specifications for heat rejection, pressure drop, flow rate, and pipe sizing were changed based on the individual systems of the vacuum, radio frequency (RF), magnet and power supply, and cryogenics sections. Finally, we used DOE guidelines to perform life-cycle cost analysis with net present value and carbon saving analysis on the systems where pipe size could be optimized.

43 PARTICLE ACCELERATORS↗

Direct Deoxygenation of Phenol over Fe-Based Bimetallic Surfaces Using On-the-Fly Surrogate Models

We present an accelerated nudged elastic band (NEB) study of phenol direct deoxygenation (DDO) on Fe-based bimetallic surfaces using a recently developed Gaussian process regression (GPR) calculator. Our test calculations demonstrate that the GPR calculator achieves up to 3 times speedup compared to conventional density functional theory calculations while maintaining high accuracy, with energy barrier errors below 0.015 eV. Using GPR-NEB, we systematically examine the DDO mechanism on pure Fe(110) and surfaces modified with Co and Ni in both top and subsurface layers. Our results show that subsurface Co and Ni substitutions preserve favorable thermodynamics and kinetics for both C–O bond cleavage and C–H bond formation, comparable to those on the pure Fe(110) surface. In contrast, top-layer substitutions generally increase the C–O bond cleavage barrier, render the step endothermic, and result in significantly higher reverse reaction rates, making DDO unfavorable on these surfaces. This work demonstrates the effectiveness of GRR-accelerated transition state searches for complex surface reactions and provides insights into rational design of bimetallic catalysts for selective deoxygenation.

Aromatic compounds↗

Uncertainty Analysis and Software Verification

Uncertainty analyses are an important part of calibrations and testing. They allow researchers insight on how to reduce and mitigate errors in testing. Each device used in testing introduces error in a system, as well as other sources such as environmental conditions, electronics, analog to digital, and random errors. Each source is carefully examined to identify how much error it introduces to a system. These sources are then combined using various methods of uncertainty calculations. To verify and validate software, a manual calculation is required to ensure the software is performing as intended. Using Excel to verify the calculations, we can identify discrepancies within the software. The root of the sum of the squares uncertainty (RSS) is used to find the combined uncertainty of a device at one and two standard deviations of the mean. Calibrations on accelerometers are performed using a vibration system along with a back-toback reference accelerometer. The vibration system takes a reference point at 100Hz frequency at 10g amplitude. The sensitivities are collected at each dialed in frequency. The sensitivity of the device represents the electrical output of the UUT (mV, pC, etc.) per unit of acceleration (g). The full history of sensitivities of selected accelerometers are used to find the averaged, standard deviation, and uncertainty of the device at each frequency tested. The uncertainty calculations from excel and the software are then compared.

97 MATHEMATICS AND COMPUTING↗

Extra-Cold EP Process at Fermilab

FNAL has established a cold Electro-Polishing (EP) method which maintains the outer surface temperature of cavity cell around 12~15°C during EP process. Cold EP has been applied on the various SRF cavities and contributed to achieve high RF performances with them. To investigate more feasibility and capability of EP at lower temperature, the FNAL EP temperature control tool was recently improved. Extra-cold EP process below 0°C at cavity cell region was successfully performed on 1.3 GHz 1-cell cavity. A compatible RF performance with cold EP method was also demonstrated during the cavity vertical testing. The details of extra-cold EP process and the cavity test results will be presented.

43 PARTICLE ACCELERATORS↗

Millikelvin Cryogenics at Fermilab

Millikelvin cryogenics is an emergent area for Fermilab with broad applications in particle detection for the cosmic frontier and quantum information science. Fermilab Cryogenic Engineering currently supports multiple experiments, including the SuperCDMS SNOLAB and ADMX dark matter experiments, along with several millikelvin test facilities. More programs are expected to come online in future.

43 PARTICLE ACCELERATORS↗

Mo-100 Disk Structural Integrity Tests I

The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in beam during production. The beam preferentially heats the disk center, while the aggressive cooling by the helium keeps areas outside the beam spot relatively cool. The result is a temperature gradient of up to 900°C over the radial distance of 14.5 mm. To test the disk integrity with this high temperature gradient, a special holder for a single disk was made such that proper cooling can be applied as in the design target and the disk heating can be replicated with induction heating. NorthStar press and sintered disks were used for these tests.

36 MATERIALS SCIENCE↗

Large Area Picosecond PhotoDetector (LAPPD) definitive tests

The goal of the project was to determine the optimal functional parameters for a new LAPPD, determine the cloud charge radius and test for gain variation due to pore sharing. Also, cosmics tests with C4F8 heavy gas of the new LAPPD were planned.

43 PARTICLE ACCELERATORS↗

FY25 Status Update on A709 Code Case Testing at ANL

This report provides an update on the status of the creep rupture testing on the precipitation-treated (PT) Alloy 709 samples fabricated from the first, the second and the third commercial heats, in support of the first, 100,000-hour Alloy 709 Code Case development under the American Society of Mechanical Engineers (ASME) Section III, Division 5 for high-temperature reactor construction. In Fiscal Year (FY) 25, no new tests were initiated, while 5 previously loaded tests were completed. This report presents an overview of the creep-rupture data gathered at Argonne National Laboratory (ANL) since FY21 that totaled 52 completed tests. Metallographic images showing crack morphologies in some representative samples ruptured in FY25 are also included. Key conclusions include: 1) the creep behavior of the three heats of Alloy 709 can be well described by the Larson-Miller relationship; 2) higher temperatures and larger stresses lead to shorter creep life and higher minimum creep rate; 3) Alloy 709 is overall very ductile under creep; 4) the crack morphologies near fracture surfaces are dependent on material’s grain size and test conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of 3-cell Traveling Wave SRF Cavity

Traveling wave SRF cavity is a new technology and requires a multi-stage process for development. Conceptual designs have been proposed to adopt TW resonance in an SRF cavity The early stages of developments have been funded by several SBIR grants to Euclid Techlabs which were completed in collaboration with Fermilab. A 3-cell proof-of-principle TW cavity was fabricated as part of that and demonstrated the TW resonance excitation at room temperature. A TW resonance control tuner for the 3-cell was also fabricated and the preliminary tests were performed. Now, the 3-cell cavity is being processed and prepared for the first cryogenic testing.

43 PARTICLE ACCELERATORS↗

Microstructural Coarsening Kinetics and Mechanical Property Changes in Long-Term Aged Sn–Pb–Sb Solder Joints

Tin-lead-antimony (50Sn–47Pb–3Sb wt.%) soldered assemblies were mechanically tested approximately 30 years after initial production and found to have solder joints of reduced strength. The microstructure of this solder alloy exhibits a ternary eutectic structure with Sn-rich, Pb-rich, and SnSb phases. Accelerated aging was performed to evaluate solder microstructural coarsening and associated strength of laboratory solder joints to correlate these properties to the “naturally aged” solder joints. Isothermal aging was conducted at room temperature, 55, 70, 100, and 135 °C and aging times that ranged from 0.1 to 365 days. The coarsening kinetics of the Pb-rich phase were determined through optical microscopy and image analysis methods established in previous studies on binary Sn–Pb solder. A kinetic equation was developed with time exponent n of 0.43 and activation energy of 24000 J/mol, suggesting grain boundary diffusion or other fast diffusion pathways controlling the microstructural evolution. Compression testing and Vickers microhardness showed significant strength loss within the first 20–30 days after soldering; then, the microstructure and mechanical properties changed more slowly over long periods of time. Further, by combining accelerated aging data and the microstructure-based kinetics, strength predictions were made that match well with the properties of the actual soldered assemblies naturally aged for 30 years. However, aging at the highest temperature of 135 °C produced anomalous behavior suggesting that extraneous aging mechanisms are active. Therefore, data obtained at this temperature or higher should not be used. Overall, the combined microstructural and mechanical property methods used in this study confirmed that the observed reduction in strength of ~ 30-year-old solder joints can be accounted for by the microstructural coarsening that takes place during long-term solid-state aging.

36 MATERIALS SCIENCE↗

Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V

A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at the beam center region with an irradiation temperature around 120 oC. Tensile tests showed increased hardness and a large decrease in ductility for the dual a+ß-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near a-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each a-phase grain. The ß-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated ?-phase precipitation in an advanced formation stage. The radiation-induced ?-phase transformation in the ß-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less ß-phase.google scho

Tensile Test, titanium, acclerator, proton beam↗

Test Stand Functional Requirements for Testing MQXFA Magnets and Q1/Q3 Cryostat Assemblies (Rev.3)

This document specifies test stand requirements for testing the High Luminosity LHC (HL-LHC, or HiLumi LHC) MQXFA magnets and LQXFA/B cryostat assemblies. Total of 12 (3 pre-series, 7 series production and 2 re-work) of these cryostat assemblies are expected to be fabricated and delivered to CERN by the U.S. HL-LHC Accelerator Upgrade Project (US HL-LHC AUP) as part of the U.S. contributions to the LHC High Luminosity Upgrade. These cryostat assemblies are the quadrupole magnetic components of the HL-LHC Q1 (LQXFA) and Q3 (LQXFB) inner triplet optical elements in front of the interactions points 1 (ATLAS) and 5 (CMS). One LMQXFA cold mass is installed in each cryostat assembly and each cold mass consists of two MQXFA quadrupole magnets. MQXFA, LMQXFA and LQXFA/B functional requirements are specified in [1,2,3].MQXFA magnets will be tested at BNL Vertical Magnet Test Facility (VMTF) and 12 cryostat assembly tests planned at Fermilab’s Horizontal Magnet Test Facility (HMTF). This document specifies the test stand functional requirements for testing MQXFA magnets and LQXFA/B cryostat assemblies.