Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Neutralization profiles of HIV-1 viruses from the VRC01 Antibody Mediated Prevention (AMP) trials

The VRC01 Antibody Mediated Prevention (AMP) efficacy trials conducted between 2016 and 2020 showed for the first time that passively administered broadly neutralizing antibodies (bnAbs) could prevent HIV-1 acquisition against bnAb-sensitive viruses. HIV-1 viruses isolated from AMP participants who acquired infection during the study in the sub-Saharan African (HVTN 703/HPTN 081) and the Americas/European (HVTN 704/HPTN 085) trials represent a panel of currently circulating strains of HIV-1 and offer a unique opportunity to investigate the sensitivity of the virus to broadly neutralizing antibodies (bnAbs) being considered for clinical development. Pseudoviruses were constructed using envelope sequences from 218 individuals. The majority of viruses identified were clade B and C; with clades A, D, F and G and recombinants AC and BF detected at lower frequencies. We tested eight bnAbs in clinical development (VRC01, VRC07-523LS, 3BNC117, CAP256.25, PGDM1400, PGT121, 10–1074 and 10E8v4) for neutralization against all AMP placebo viruses (n = 76). Compared to older clade C viruses (1998–2010), the HVTN703/HPTN081 clade C viruses showed increased resistance to VRC07-523LS and CAP256.25. At a concentration of 1μg/ml (IC80), predictive modeling identified the triple combination of V3/V2-glycan/CD4bs-targeting bnAbs (10-1074/PGDM1400/VRC07-523LS) as the best against clade C viruses and a combination of MPER/V3/CD4bs-targeting bnAbs (10E8v4/10-1074/VRC07-523LS) as the best against clade B viruses, due to low coverage of V2-glycan directed bnAbs against clade B viruses. Overall, the AMP placebo viruses represent a valuable resource for defining the sensitivity of contemporaneous circulating viral strains to bnAbs and highlight the need to update reference panels regularly. Our data also suggests that combining bnAbs in passive immunization trials would improve coverage of global viruses.

60 APPLIED LIFE SCIENCES↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

A-site occupancy effects on structure, ionic conductivity, and thermodynamic stability of KxMgx/2Ti8−x/2O16

Abstract K x Mg x /2 Ti 8− x /2 O 16 (1.54 ≤ x ≤ 2) hollandite samples synthesized using a conventional solid-state route were used to investigate the effect of structure, ionic conductivity, and thermodynamic stability as a function of A-site (K) occupancy. The ionic conductivity, as measured using AC impedance spectroscopy, decreased as the A-site occupancy (and K content) increased. Titanate hollandite, of the form K x Mg x /2 Ti 8− x /2 O 16 , was measured using high-temperature oxide melt solution calorimetry in sodium molybdate (3Na 2 O $$\bullet$$ ∙ 4MoO 3 ) solvent at 804 $$^\circ{\rm C}$$ ∘ C . The enthalpies of formation are strongly exothermic indicating that they are thermodynamically stable relative to their constituent oxides. Previous studies have demonstrated increased stability with an increase in Cs content at fixed A-site occupancy. This work demonstrated an increase in the stability for the K-bearing hollandite samples with an increase in K content and tunnel occupancy. The measured enthalpies of formation (∆ H f,ox ) were in good agreement with density functional theory (DFT) predictions. Graphical abstract

Cassell, Nakeshma S.↗

Advanced Micro Combined Heat and Power Device

U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

AmeriFlux FLUXNET-1F US-Dk1 Duke Forest-open field

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Dk1 Duke Forest-open field. This is the FLUXNET version of the carbon flux data for the site US-Dk1 Duke Forest-open field produced by applying the standard ONEFlux (1F) software. Site Description - The Duke Forest grass field is approximately 480×305 m, dominated by the C3 grass Festuca arundinacea Shreb. (tall fescue) includes minor components of C3 herbs and the C4 grass Schizachyrium scoparium (Michx.) Nash, not considered here. The site was burned in 1979 and is mowed annually during the summer for hay according to local practices. Lai, C.T. and G.G. Katul, 2000, "The dynamic role of root-water uptake in coupling potential to actual transpiration" , Advances in Water Resources, 23, 427-439; Novick , K.A., P. C. Stoy, G. G. Katul, D. S. Ellsworth, M. B. S. Siqueira, J. Juang, R. Oren, 2004, Carbon dioxide and water vapor exchange in a warm temperate grassland, Oecologia, 138, 259-274; Stoy PC, Katul GG, Siqueira MBS, Juang J-Y, McCarthy HR, Oishi AC, Uebelherr JM, Kim H-S, Oren R (2006). Separating the effects of climate and vegetation on evapotranspiration along a successional chronosequence in the southeastern U.S. Global Change Biology 12:2115-2135

Oishi, Chris [USDA Forest Service]↗

Evaluating Function-as-a-Service (FaaS) frameworks for the Accelerator Control System

As particle accelerator control systems evolve in complexity and scale, the need for responsive, scalable, and cost-effective computational infrastructure becomes increasingly critical. Function-as-a-Service (FaaS) offers an alternative to traditional monolithic architecture by enabling event-driven execution, automatic scaling, and fine-grained resource utilization. This paper explores the applicability and performance of FaaS frameworks in the context of a modern particle accelerator control system, with the objective of evaluating their suitability for short lived and triggered workloads. In this paper, we evaluate prominent open-source FaaS platforms in executing functional logic, triggers, and diagnostics routines. Evaluation metrics consist of cold-start latency, scalability, performance, integration with other open-source tools like Kafka. Experimental workloads were designed to simulate real-world control tasks when implemented as stateless FaaS functions. These workloads were benchmarked under various invocation loads and network conditions. Self-hosted FaaS platforms, when deployed within accelerator networks, offer greater control over execution environment, better integration with legacy systems, and support for real-time guarantees when paired with message queues. Based on lessons learned and evaluation metrics, this paper describes reliability of the FaaS framework for the Accelerator Control Systems (ACS).

Jaikar, A. [Fermilab] (ORCID:0000000332046217)↗

The Need for Nb3Sn Coated Cu Cavities for Future Accelerators

Based on current efforts in the U.S. on the novel concept of parallel-feed RF accelerator structures, and in the U.S. and abroad in producing Nb3Sn films on either Cu or bronze, we rec-ommend that the Particle Physics community foster R&D in Superconducting Nb3Sn coated Cu RF Cavities instead of costly bulk Nb. The paper includes methods to process the coated cavi-ties at temperatures consistent with Cu retaining its shape. A devoted global effort in develop-ing Cu cavity structures coated with Nb3Sn would make the ILC or Higgs factories more afforda-ble and more likely to be built. Not only do parallel-feed RF structures enable both higher ac-celerating gradients and higher efficiencies, but they would be applicable to both Cu and Nb3Sn coated Cu cells. Increased effort on these two techniques would synergize expenditures to-wards progress, which will converge on the choice of technology for the RF of an ILC or any fu-ture accelerator. The current methods of Nb3Sn coatings on Cu or bronze can be geared also towards standard cavity cells. In conclusion, the use of distributed coupling structure topology within improved performance parameters together with Nb3Sn coating technology can lead to a paradigm shift for superconducting linacs, with higher gradient, higher temperature of opera-tion, and reduced overall costs for any future collider.

43 PARTICLE ACCELERATORS↗

PROGRESS ON MAGNETRON R&DS FOR INDUSTRIAL PARTICLE ACCELERATORS

The magnetron as an efficient RF source for a compact industrial SRF accelerator has been developed. The per-formance of injection phase lock on two independent magnetron transmitters operated at 915MHz, in CW mode with maximum power of 75kW each has been demon-strated to satisfy this application. This industrial type magnetron has AC transformer and the SCR rectifier on the DC anode power supply. Output power spectrum with phase locking can achieve noise reduction of -21.2 dBc at the 1st 60 Hz, -28.0 dBc at 1st 180 Hz with only -22.6 dBc injection power. Further control studies for 2×75 kW, 915 MHz power combing by WR975 magic-tee at Jefferson Lab (JLab) and for 4×1.2 kW, 2.45 GHz power combing by WR340 magic-tee at General Atomics (GA).

Rimmer, R.↗

Radioisotope production at the Spallation Neutron Source: Design concept of isotope production target

Upon completion of the Second Target Station (STS) Project in the mid 2030s, the Spallation Neutron Source accelerator at Oak Ridge National Laboratory will deliver a 2.7 MW proton beam to the neutron production targets. In the post-STS phase, the accelerator will have a reserve beam power capacity of at least 100 kW beyond what the two neutron production targets will receive, which could potentially be ramped up to 300 kW. In this paper, a design concept for a radioisotope production target that could utilize 250 kW of the reserve beam power capacity is presented. The target consists of thorium discs encapsulated in 316L austenitic steel shells that are cooled by water. The estimated post-irradiation activity of Ac-225 and Ra-225, critical medical radioisotopes used in targeted alpha therapy cancer treatment, is calculated at the end of bombardment after a 14 day long irradiation time. Thermal and structural analyses are performed on the basis of calculated nuclear heating data. The technical feasibility of a high-power target under a 250-kW beam load with an extremely low duty factor of $3.5\cdot 10^{-6}$ is presented from thermal, structural and fatigue lifetime perspectives.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Pueblo of Picuris Phase I Community Solar Project (Final Report)

The Pueblo of Picuris Community Solar Project (Project) is a 1-megawatt (MW) alternating current (AC) ground mounted, fixed tilt solar photovoltaic system that became operational on December 18th, 2017. The Project, which was partially funded by the DOE (Grant No. DEIE0000033), generates revenue for the Tribe through a Power Purchase Agreement (PPA) with the electric utility, Kit Carson Electric Cooperative. The PPA revenue provides Tribal members with residential and commercial electric utility bill offsets and also supports critical Tribal programs. This Final Report provides a technical overview of the Project, documents the Project’s development process and outcomes, identifies successes and challenges, and offers recommendations for similarly funded tribal projects.

1 megawatt solar↗

Oak Ridge National Laboratory Current Magnitude and Frequency Response of SIPROTEC Relays

This project examined the current magnitude and frequency response of 7SJ61 and 7SJ62 SIPROTEC relays. The measured sample frequencies for the 7SJ61 and 7SJS62 relays were 800 and 960 Hz, respectively. The relays were tested at frequencies of up to 1 and 20.16 kHz. Two experiments were run in a lab environment. The first experiment was run at frequencies of up to 1 kHz every 10 Hz. The second one was run at frequencies of up to 20.16 kHz every 200 and 240 Hz (common factors of sample rate frequency) for the 7SJ61 and 7SJ62 SIPROTEC relays, respectively. Both experiments were set at a current magnitude of 0.1 and 0.5 Arms. A testbed with a Relay Test Equipment (RTE) was set to run the experiment at frequencies of up to 1 kHz, while a testbed with a RTE and High Frequency Power Source/ Amplifier (HFPS/A) was set to run at frequencies of up to 20.16 kHz. Currents of 0.1 and 0.5 Arms at different frequencies were connected at Phase A of the relays, and a current of 1 Arms (60 Hz) was connected at Phase B of relays. The 1 Arms current allowed the relays to trip and saved their record events by setting both relays at a definite-time overcurrent protection function. The record events were collected after the 7SJ61 and 7SJ62 relays tripped, and the current magnitude and frequency were plotted. The record events from the relays were collected using the DIGSI® 4 software. The SYNCHROWAVE® Event and MATLAB® software were then used to plot the current magnitude and frequency, respectively, from the relay record events. The current magnitude and frequency were plotted at time and frequency domain, respectively.The 7SJ61 and 7SJ62 relays measured source frequencies of up to 400 and 480 Hz, respectively. The percentage error of frequency for the relays increased after 400 and 480 Hz, respectively. The 7SJ62 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1440 Hz. The 7SJ61 relay with 0.1 and 0.5 Arms measured the alias frequency up to 1000 and 1200 Hz, respectively. At frequencies higher than the alias frequency, the relays measured a DC amplitude current instead of an AC amplitude current. In the DC amplitude current zone, non-desired frequencies were measured by both relays. The current magnitude intensity (dB) for the 7SJ61 and 7SJ62 relays from 1 to 20.16 kHz were plotted. The current magnitude intensity for the 7SJ61 relay decreased up to 2600 and 1200 Hz for 0.5 and 0.1 Arms tests, respectively. However, the current magnitude intensity for the 7SJ62 relay decreased up to 4800 and 2640 Hz for 0.5 and 0.1 Arms tests, respectively. The current magnitude and frequency response study for the 7SJ61 and 7SJ62 relays was performed satisfactorily, observing the source, alias, and non-desired measured frequency zones for both relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

American Chemical Society's summer school in nuclear and radiochemistry. Final report

The ACS Summer Schools in Nuclear and Radiochemistry (herein called “Summer Schools”) were held each year at San Jose State University (SJSU) and Brookhaven National Laboratory (BNL). The Summer Schools are an intensive, six-week program that includes both a lecture component covering fundamental principles of nuclear chemistry and radiochemistry and a laboratory component providing hands-on experience for the students to observe and test many of the basic principles that they learn about in lecture and in the special seminars. Each site hosts 12 undergraduate students annually. Participants are selected from a nation-wide pool of applicants who are currently enrolled as undergraduates seeking bachelors’ degrees, preferably in disciplines of physical sciences or engineering. To broaden the students’ perspectives on nuclear science, prominent research scientists active in nuclear and/or radiochemical research participate in a Guest Lecture Series. Symposia emphasizing nuclear security, nuclear medicine, and career opportunities are conducted as a part of the program.

07 ISOTOPE AND RADIATION SOURCES↗

TWF Waste Container Intra-Facility Transfer and Outgoing Shipment

This procedure provides instructions for the inspection and transfer of Transuranic (TRU) Waste containers within the Transuranic Waste Facility (TWF) (Waste Storage Buildings [WSBs], Characterization Waste Storage Building [CWSB]) and Characterization Trailers. This also includes the preparation to transfer to other LANL facilities. Performance of this procedure meets the requirements of SR 4.2.1.1, 4.2.1.2, 4.2.1.4, 4.2.1.5, 4.3.4.1, SAC 5.9.1, SAC 5.9.3 and AC 5.8.13 2nd bullet, as well as requirements set forth in the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (HWFP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Accelerator Technology (Final Report)

Superconducting radio-frequency (SRF) acceleration, together with high precision RF field control and high precision beam instrumentation and control, is a key technology for future next generation accelerators. In the past 10 years, significant progress on these technologies has been made jointly at KEK and US laboratories. The research progress summarized here is Cornell University’s contribution to a continued US-Japan collaborative accelerator research effort. The combined objectives of this collaboration were to solve critical technical issues related to SRF acceleration technology, related to low emittance beam generation, and related to reducing the vertical beam size of the ATF2 final focus beam line. These joint efforts significantly advance current accelerator technologies. The specific objective of the Cornell University part of this collaboration was to develop, in close connection with KEK and FNAL, new SRF cavity Nb3Sn thin-film coating technologies for transformational cavity performance. Cornell is a world leader in the synthesis of Nb3Sn for SRF application, and has produced the first-ever next-generation non-niobium (i.e., Nb 3 Sn) prototype SRF accelerator cavities with cryogenic efficiency exceeding that of traditional niobium cavities. These next-generation Nb 3 Sn SRF cavities strongly reduce AC power consumption of SRF based accelerators, and also enable using greatly simplified cryogenic cooling infrastructure, thereby making SRF technology available to a much wider range of accelerator applications. During this project, Cornell has designed and started fabrication of a new Nb 3 Sn coating setup, which will be large enough to coat full-scale (i.e., multi-cell) SRF accelerator cavities. In addition, Cornell University has participated in other collaborative activities at KEK and partner US laboratories.

43 PARTICLE ACCELERATORS↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report-WestSmart EV: Western Smart Plug-in Electric Vehicle Community Partnership

The WestSmartEV (WSEV) project has accelerated adoption of plug-in electric vehicles (PEV) throughout the PacifiCorp/Rocky Mountain Power’s (RMP) service territory in the intermountain west by developing a large-scale, sustainable PEV charging infrastructure network with coordinated PEV adoption programs. The project objectives have strategically deployed 79 DC fast charging to create two primary electric interstate highway corridors along I-15 and I-80; incentivized installation of Level 2 AC chargers at workplace locations; incentivized the purchase of PEVs; provided all electric solutions for first-mile and last-mile trips, including electrified mobility service; provided centralized data collection, analysis, modeling, and tool development to inform investment and policy decisions; and developed education outreach materials and conducted workshops across the WSEV region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗