Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The leading hadronic vacuum polarisation on the lattice

After discussing the relevance of a first principles theory-prediction of the hadronic vacuum polarisation for Standard Model tests, the theoretical challenges for its computation in lattice QCD are reviewed. New ideas that will potentially improve the quality of lattice simulations will be introduced and the status of ongoing simulations will be presented briefly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dexterity test data contribute to proper glovebox over-glove use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

57↗

Investigation of the Semicoa 2N7616 and 2N7425 and the Microsemi 2N7480 for Single-Event Gate Rupture and Single-Event Burnout

Single-event-effect test results for hi-rel total-dose-hardened power MOSFETs are presented in this report. The 2N7616 and the 2N7425 from Semicoa and the 2N7480 from International Rectifier were tested to NASA test condition standards and requirements. The 2N7480 performed well and the data agree with the manufacture's data. The 2N7616 and 2N7425 were entry parts from Semicoa using a new device architecture. Unfortunately, the device performed poorly and Semicoa is withdrawing power MOSFETs from it line due to these data. Vertical metal-oxide-semiconductor field-effect transistors (MOSFETs) are the most commonly used power transistor. MOSFETs are typically employed in power supplies and high current switching applications. Due to the inherent high electric fields in the device, power MOSFETs are sensitive to heavy ion irradiation and can fail catastrophically as a result of single-event gate rupture (SEGR) or single-event burnout (SEB). Manufacturers have designed radiation-hardened power MOSFETs for space applications. See [1] through [5] for more information. The objective of this effort was to investigate the SEGR and SEB responses of two power MOSFETs recently produced. These tests will serve as a limited verification of these parts. It is acknowledged that further testing on the respective parts may be needed for some mission profiles.

Scheick, Leif↗

Subtask 3.11 - Production of CBTL-Based Jet Fuels from Biomass-Based Feedstocks and Montana Coal

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) and Accelergy Corporation, an advanced fuels developer with technologies exclusively licensed from Exxon Mobil, undertook Subtask 3.11 to use a recently installed bench-scale direct coal liquefaction (DCL) system capable of converting 45 pounds/hour of pulverized, dried coal to a liquid suitable for upgrading to fuels and/or chemicals. The process involves liquefaction of Rosebud mine coal (Montana coal) coupled with an upgrading scheme to produce a naphthenic fuel. The upgrading comprises catalytic hydrotreating and saturation to produce naphthenic fuel. A synthetic jet fuel was prepared by blending equal volumes of naphthenic fuel with similar aliphatic fuel derived from biomass and 11 volume % of aromatic hydrocarbons. The synthetic fuel was tested using standard ASTM International techniques to determine compliance with JP-8 fuel. The composite fuel thus produced not only meets but exceeds the military aviation fuel-screening criteria. A 500-milliliter synthetic jet fuel sample which met internal screening criteria was submitted to the Air Force Research Laboratory (AFRL) at Wright–Patterson Air Force Base, Dayton, Ohio, for evaluation. The sample was confirmed by AFRL to be in compliance with U.S. Air Force-prescribed alternative aviation fuel initial screening criteria. The results show that this fuel meets or exceeds the key specification parameters for JP-8, a petroleum-based jet fuel widely used by the U.S. military. JP-8 specifications include parameters such as freeze point, density, flash point, and others; all of which were met by the EERC fuel sample. The fuel also exceeds the thermal stability specification of JP-8 fuel as determined by the quartz crystalline microbalance (QCM) test also performed at an independent laboratory as well as AFRL. This means that the EERC fuel looks and acts identically to petroleum-derived jet fuel and can be used interchangeably without any special requirements and thus provides a pathway to energy security to the U.S. military and the entire nation. This subtask was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26- 08NT43291. Nonfederal funding was provided by Accelergy Corporation.

Sharma, Ramesh↗

Physics Prospects for a near-term Proton-Proton Collider

Hadron colliders at the energy frontier offer significant discovery potential through precise measurements of Standard Model processes and direct searches for new particles and interactions. A future hadron collider would enhance the exploration of particle physics at the electroweak scale and beyond, potentially uniting the community around a common project. The LHC has already demonstrated precision measurement and new physics search capabilities well beyond its original design goals and the HL-LHC will continue to usher in new advancements. This document highlights the physics potential of an FCC-hh machine to directly follow the HL-LHC. In order to reduce the timeline and costs, the physics impact of lower collider energies, down to $\sim 50$~TeV, is evaluated. Lower centre-of-mass energy could leverage advanced magnet technology to reduce both the cost and time to the next hadron collider. Such a machine offers a breadth of physics potential and would make key advancements in Higgs measurements, direct particle production searches, and high-energy tests of Standard Model processes. Most projected results from such a hadron-hadron collider are superior to or competitive with other proposed accelerator projects and this option offers unparalleled physics breadth. The FCC program should lay out a decision-making process that evaluates in detail options for proceeding directly to a hadron collider, including the possibility of reducing energy targets and staging the magnet installation to spread out the cost profile.

FOS: Physical sciences↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Experimental Measurement of Low Energy Neutrino Interactions

Neutrino interactions in the few to few tens of MeV range are of importance for several physics topics, including solar, supernova and reactor neutrinos, as well as future proposed oscillation and Standard Model test experiments. Although interaction cross-sections for some simple targets are well understood, very little experimental data exist for interactions with nuclei. This talk will discuss the motivation for measuring low energy neutrino interactions, the state of knowledge, and possible future strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-556: A Potential Real Time AQA for Cyberknife Cones and MLC Based Treatments

Purpose: To investigate the potential use of the Raven™ (LAP of America Laser Applications) for real time AQA of Cyberknife™ with InCise2 MLC (Accuray™ Medical). Methods: At setup, the Raven was rotated 45° on which an Accuray™ AQA cube was positioned. Three different AQA plans for fixed cone, InCise2MLC, and a modified MLC plan were delivered repeatedly ten times. The additional shapes in modified AQA plan enable additional reproducibility checks for all the MLC pairs. During the test, the cube was aligned by imbedded fiducials and irradiated. The two angled radiation beams aimed center tungsten ball of the cube and projected 45° to phosphor screen and registered by a CCD camera of the Raven device. The centricity of the metal ball in the irradiated field was then analyzed using Matlab codes. Results: For AP images, the average offsets of X, Y, and radial directions are 0.24 ± 0.04 mm, 0.25 ± 0.02 mm and 0.35 ±± 0.03 mm respectively for the cone; 0.34 ± 0.02 mm, 0.49 ± 0.04 mm and 0.60 ± 0.04 mm respectively for the MLC. For lateral images, they are 0.63 ± 0.05 mm, 0.11 ± 0.02 mm and 0.64 ± 0.04 mm respectively for the cone, 0.79 ± 0.08 mm, −0.23 ± 0.06 mm and 0.82 ± 0.09 mm respectively for the MLC. No inconsistent MLC shapes were found in the modified AQA group. Conclusion: The results are consistent with clinically acceptable values (≤1mm from baseline). The results suggest the potential of replacement of the standard AQA test with the novel real-time Raven device for Cyberknife daily QA. The modified MLC based AQA provides a more comprehensive MLC daily QA capability. Further improvements in its resolution and automatic analyzing capability are warranted.

60 APPLIED LIFE SCIENCES↗

Quantification of a Minimum Detectable Soiling Level to Affect Photovoltaic Devices by Natural and Simulated Soils

Here, we report that soil accumulation on photovoltaic (PV) modules presents a challenge to long-term performance prediction and lifetime estimates due to the inherent difficulty in quantifying small changes over an extended period. Low mass loadings of soil are a common occurrence but remain difficult to quantify. In order to more accurately describe the specific effects of sparse soil films on PV systems, we have expanded upon an earlier technique to measure the optical losses due to an artificially applied obscurant film. A synthetic soil analog was sprayed onto glass coupons at very brief intervals with a high-volume, low-pressure pneumatic sprayer. Light transmission through the grime film was evaluated using a quantum efficiency test stand and UV/vis spectroscopy. A 0.1-g/m 2 grime loading was determined to be the limit of mass measurement sensitivity, which is similar to some reports of daily soil accumulation. Predictable, linear decreases in transmission were observed for samples with a mass loading between 0.1 and 0.5 g/m 2 . A similar change was observed for soiled coupons from an outdoor monitoring station. Collected soil from the field coupons was analyzed to develop a compositional analog for indoor studies. Lastly, natural and synthetic soils produced similar decreases in transmission.

14 SOLAR ENERGY↗

Spin correlations in the Drell–Yan process, parton entanglement, and other unconventional QCD effects

We review ideas on the structure of the QCD vacuum which had served as motivation for the discussion of various non-standard QCD effects in high-energy reactions in articles from 1984 to 1995. These effects include, in particular, transverse-momentum and spin correlations in the Drell–Yan process and soft photon production in hadron–hadron collisions. We discuss the relation of the approach introduced in the above-mentioned articles to the approach, developed later, using transverse-momentum-dependent parton distributions (TDMs). The latter approach is a special case of our more general one which allows for parton entanglement in high-energy reactions. We discuss signatures of parton entanglement in the Drell–Yan reaction. Also for Higgs-boson production in pp collisions via gluon–gluon annihilation effects of entanglement of the two gluons are discussed and are found to be potentially important. These effects can be looked for in the current LHC experiments. In our opinion studying parton-entanglement effects in high-energy reactions is, on the one hand, very worthwhile by itself and, on the other hand, it allows to perform quantitative tests of standard factorisation assumptions. Clearly, the experimental observation of parton-entanglement effects in the Drell–Yan reaction and/or in Higgs-boson production would have a great impact on our understanding how QCD works in high-energy collisions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Dexterity test data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.

42 ENGINEERING↗

Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

Wright, Kenneth H.↗

GRB 090313 AND THE ORIGIN OF OPTICAL PEAKS IN GAMMA-RAY BURST LIGHT CURVES: IMPLICATIONS FOR LORENTZ FACTORS AND RADIO FLARES

We use a sample of 19 gamma-ray bursts (GRBs) that exhibit single-peaked optical light curves to test the standard fireball model by investigating the relationship between the time of the onset of the afterglow and the temporal rising index. Our sample includes GRBs and X-ray flashes for which we derive a wide range of initial Lorentz factors (40 < {Gamma} < 450). Using plausible model parameters, the typical frequency of the forward shock is expected to lie close to the optical band; within this low typical frequency framework, we use the optical data to constrain {epsilon}{sub e} and show that values derived from the early time light-curve properties are consistent with published typical values derived from other afterglow studies. We produce expected radio light curves by predicting the temporal evolution of the expected radio emission from forward and reverse shock components, including synchrotron self-absorption effects at early time. Although a number of GRBs in this sample do not have published radio measurements, we demonstrate the effectiveness of this method in the case of Swift GRB 090313, for which millimetric and centimetric observations were available, and conclude that future detections of reverse-shock radio flares with new radio facilities such as the EVLA and ALMA will test the low-frequency model and provide constraints on magnetic models.

79 ASTRONOMY AND ASTROPHYSICS↗

TESTING MODELS OF MAGNETIC FIELD EVOLUTION OF NEUTRON STARS WITH THE STATISTICAL PROPERTIES OF THEIR SPIN EVOLUTIONS

We test models for the evolution of neutron star (NS) magnetic fields (B). Our model for the evolution of the NS spin is taken from an analysis of pulsar timing noise presented by Hobbs et al.. We first test the standard model of a pulsar's magnetosphere in which B does not change with time and magnetic dipole radiation is assumed to dominate the pulsar's spin-down. We find that this model fails to predict both the magnitudes and signs of the second derivatives of the spin frequencies ({nu}-double dot). We then construct a phenomenological model of the evolution of B, which contains a long-term decay (LTD) modulated by short-term oscillations; a pulsar's spin is thus modified by its B-evolution. We find that an exponential LTD is not favored by the observed statistical properties of {nu}-double dot for young pulsars and fails to explain the fact that {nu}-double dot is negative for roughly half of the old pulsars. A simple power-law LTD can explain all the observed statistical properties of {nu}-double dot. Finally, we discuss some physical implications of our results to models of the B-decay of NSs and suggest reliable determination of the true ages of many young NSs is needed, in order to constrain further the physical mechanisms of their B-decay. Our model can be further tested with the measured evolutions of {nu}-dot and {nu}-double dot for an individual pulsar; the decay index, oscillation amplitude, and period can also be determined this way for the pulsar.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗