Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Review of particle physics

This biennial Review summarizes much of particle physics. Using data from previous editions, plus 2158 new measurements from 551 papers, we list, evaluate, and average measured properties of gauge bosons, leptons, quarks, mesons, and baryons. We al so summarize searches for hypothetical particles such as Higgs bosons, heavy neutrinos, and supersymmetric particles. All the particle properties and search limits are listed in Summary Tables. We also give numerous tables, figures, formulae, and reviews of topics such as the Standard Model, particle detectors, probability, and statistics. Among the 108 reviews are many that are new or heavily revised including those on neutrino mass, mixing, and oscillations, QCD, top quark, CKM quark-mixing matrix, V(ud ) & V(us), V(cb) & V(ub), fragmentation functions, particle detectors for accelerator and non-accelerator physics, magnetic monopoles, cosmological parameters, and big bang cosmology. A booklet is available containing the Summary Tables and abbreviated ve rsions of some of the other sections of this full Review. All tables, listings, and reviews (and errata) are also available on the Particle Data Group website: pdg.lbl.gov.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New equation of state for astrophysical simulations

We generate a new complete equation of state (EOS) of nuclear matter for a wide range of temperatures, densities, and proton fractions ready for use in astrophysical simulations of supernovae and neutron star mergers. Our previous two papers tabulated the EOS at over 180 000 grid points in the temperature range T=0-80 MeV, the density range n{sub B}=10{sup -8}-1.6 fm{sup -3}, and the proton fraction range Y{sub P}=0-0.56. In this paper we combine these data points using a suitable interpolation scheme to generate a single EOS table on a finer grid. This table is thermodynamically consistent and conserves entropy during adiabatic compression tests. We present various thermodynamic quantities and the composition of matter in the new EOS, along with several comparisons with existing EOS tables. Our EOS table is available for download.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,873 new measurements from 758 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Here, among the 118 reviews are many that are new or heavily revised, including a new review on Neutrinos in Cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exact direct-space asymmetric units for the 230 crystallographic space groups

It is well known that the direct-space asymmetric unit definitions found in the International Tables for Crystallography, Volume A, are inexact at the borders. Face- and edge-specific sub-conditions have to be added to remove parts redundant under symmetry. This paper introduces a concise geometric notation for asymmetric unit conditions. The notation is the foundation for a reference table of exact direct-space asymmetric unit definitions for the 230 crystallographic space-group types. The change-of-basis transformation law for the conditions is derived, which allows the information from the reference table to be used for any space-group setting. We also show how the vertices of an asymmetric unit can easily be computed from the information in the reference table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

Feasibility study of real-time planning for stereotactic radiosurgery

Purpose: 3D rotational setup errors in radiotherapy are often ignored by most clinics due to inability to correct or simulate them accurately and efficiently. There are two types of rotation-related problems in a clinical setting. One is to assess the affected dose distribution in real-time if correction is not applied and the other one is to correct the rotational setup errors prior to the initiation of the treatment. Here, the authors present the analytical solutions to both problems. Methods: (1) To assess the real-time dose distribution, eight stereotactic radiosurgery (SRS) cases were used as examples. For each plan, two new sets of beams with different table, gantry, and collimator angles were given in analytical forms as a function of patient rotational errors. The new beams simulate the rotational effects of the patient during the treatment setup. By using one arbitrary set of beams, SRS plans were recomputed with a series of different combinations of patient rotational errors, ranging from (-5 Degree-Sign , -5 Degree-Sign , -5 Degree-Sign ) to (5 Degree-Sign , 5 Degree-Sign , 5 Degree-Sign ) (roll, pitch, and yaw) with an increment of 1 Degree-Sign and compared with those without rotational errors. For each set of rotational errors, its corresponding equivalent beams were computed using the analytical solutions and then used for dose calculation. (2) To correct for the rotational errors, two new sets of table, gantry, and collimator angles were derived analytically to validate the previously published derivation. However, in the derivation, a novel methodology was developed and two sets of table, gantry, and collimator angles were obtained in analytical forms. The solutions provide an alternative approach to rotational error correction by rotating the couch, gantry, and collimator rather than the patient. Results: For demonstration purpose, the above-derived new beams were implemented in a treatment planning system (TPS) to study the rotational effects on the SRS cases. For each case, the authors have generated ten additional plans that accounted for different rotations of the patient. They have found that rotations have an insignificant effect on the minimal, maximum, mean doses, and V{sub 80%} of the planning target volume (PTV) when the rotations were relatively small. This was particularly true for the small and near-spherical targets. They, however, did change V{sub 95%} significantly when the rotations approached 5 Degree-Sign . The theory has been validated with clinical SRS cases and proven to be practical and viable. The preliminary results demonstrate that the rotational effects are patient-specific and depend on several important factors, such as the PTV size, the PTV location, and the beam configuration. The solutions given in this paper are of great potential values in clinical applications. Conclusions: They have derived the analytical solutions to a new set of table, gantry, and collimator angles for a given treatment beam configuration as a function of patient rotational errors. One solution was used to assess the dosimetric effects of an imperfect patient setup and the other one was used to correct for the setup errors without rotating the patient. Compared to the widely adopted method of rotation effect assessment by importing the rotational CT images into TPS, the equivalent beam approach is simple and accurate. The analytical solutions to correcting for rotational setup errors prior to treatment were also derived. Based on the initial clinical investigations, they firmly believe that clinically viable real-time treatment planning and adaptive radiation therapy are feasible with this novel method.

60 APPLIED LIFE SCIENCES↗

SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

60 APPLIED LIFE SCIENCES↗

Technical Note: On the analytical proton dose evaluation in compounds and mixtures

Purpose: By combining the physical processes occurring due to the interaction of protons with matter, analytical theories published so far have provided acceptable models for calculating depth-dose distributions in homogeneous media. As a well-defined and comprehensive theory, the formula derived by Bortfeld models the dose transferred to the target in terms of the parabolic cylinder function. The model also includes three parameters with values specified for an initial proton energy and for the target material. These parameters are obtainable through the data gathered in nuclear data tables. The analytical studies using this interesting model are therefore restricted to those materials for which the data have been provided in these tables. This study aims to find general solutions for calculation of these parameters for a compound or mixture composed of an arbitrary choice of constituent elements. Methods: Inspired by formulas dedicated for calculating the range and the probability of undergoing nonelastic nuclear interactions for protons in desired compounds, the analytical methods for finding the three mentioned parameters are investigated. The accuracy of the methods suggested is examined through comparison of the results with those which are calculated using the data taken from nuclear data tables. By employing the calculated parameters using the derived formulas in the Bortfeld model, the dose distribution at depth in a chosen target is calculated. Results: For an arbitrary selection of compounds, the predictions of the analytical depth-dose model using these parameters have been found to closely match the results employing the parameters calculated using the data reported in nuclear data tables. Conclusions: The formulas presented are general, mathematically easy to handle, and valid for almost every compound or mixture including materials of interest for proton radiotherapy purposes, making the Bortfeld model more practical and advantageous.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-496: An Investigation of Two Novel Devices for Testing Linac Clearance During CT Simulation

Purpose: This work’s objective is to determine the efficacy of two newly patented devices termed the Mor-O rings, Mark1 and Mark2, developed to predict collisions between the patient and a linac at the time of CT simulation. Methods: Mark1: A ring with an inner radius equal to the distance between the isocenter and the nearest portion of a linac head(diso) was made. This is mounted to a stand that allows vertical repositioning. The ring is placed around the patient on the CT table and aligned with isocenter. The patient is moved through the ring. If the ring touches the patient, a collision is predicted. To test this device, predicted collisions were marked on a phantom. The phantom was then repositioned on the linac table where the collisions were verified. Mark2: An arc with the radius diso was created with a re-locatable half-linac head wire-frame. The Mark2 is positioned in the same way as the Mark1 but can additionally mimic couch and gantry angulations. The Mark2 was tested with a volunteer using multiple couch, gantry and isocenter positions. The volunteer was then repositioned on the linac table to verify the angles of collisions. Results: Mark1: One isocenter out of ten showed negative clearance (0.9mm) on the linac table. All other collisions were predicted with 1 to 36mm of additional clearance. Mark2: All collisions were prevented with an additional 1.3 to 14.8 degrees of clearance. Conclusion: The Mark1 prototype is able to predict all collisions when no couch angulation is used. This device takes less than a minute to setup and is simple to use. The Mark2, when testing beam geometries used for noncoplanar SBRT, was able to prevent all collisions with 1.3 to 14.8 degrees additional clearance. Improvements in construction for both devices could increase accuracy and usability. Andrew Morrow owns Morrow Physics, LLC and Brian Massingill owns Spur Physics, LLC. We are both listed on the patent for the devices investigated in this work (patent 9220922). Our current employer, Baylor Scott and White, is also on the patent.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-05: Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation

Purpose: Apparent patient size in CT localizers varies with localizer type and patient positioning, resulting in variation in effective mAs as guided by Tube Current Modulation (TCM). Our aim was to investigate the effects of vertical off-centering on CTDI-vol when using different localizer types and TCM strengths. Methods: A CTDI body phantom was scanned using an abdominal protocol with three TCM strengths (Siemens Definition AS40, CAREDose4D; very weak, average, very strong). Data was acquired at 11 table height positions; with phantom center at isocenter and at 10 other positions between 142mm below and 53mm above. At each position, scans were acquired using 5 different localizer types: PA, AP, Lateral, PA+Lateral, and Lateral+PA. CTDI-vol was recorded for the 165 combinations of table height, localizer type, and TCM strength, and magnification factors measured from localizer images. Results: Magnification factors from AP and PA localizers ranged from 0.79–1.11 and 1.35–0.91, respectively from lowest to highest positions (highest with phantom located closest to X-ray tube), with a smaller impact when using Lateral, PA+Lateral, Lateral+PA localizer types, all of which behaved similarly. For an average TCM strength and PA localizer, CTDI-vol ranged from 75% higher to 12% lower than the isocenter value for the lowest to highest table positions, respectively. For table positions ranging from lowest to highest, CTDI-vol ranged from −23% to 17% for AP, from −8% to 0.3% for lateral and from −7% to 1% for a combination of PA and Lateral in either order. Similar behavior was found for different TCM strengths, but effects were more pronounced for very strong compared with very weak modulation strengths. Conclusion: Patient off-centering substantially impacts radiation dose, which depends on the amount of vertical offcentering and type of the localizer used. The combination of PA and Lateral localizers is most robust against effects of patient off-centering.

60 APPLIED LIFE SCIENCES↗

The Effect of Ligands and Solvents on Nonradiative Transitions in Semiconductor Quantum Dots (A Review)

Data on quantum yields and photoluminescence decay times of quantum dots have been collected. Photoprocesses that occur in quantum dots are compared with photoprocesses occurring in complex organic molecules in the condensed phase. The review consists of the introduction, three parts, and conclusions. The first two parts are devoted to quantum dots that are formed by indirect-gap semiconductors. The first part is devoted to data on the photoluminescence quantum yields and decay times of carbon quantum dots, and Table 1 presents selected values and short comments to these data. Table 2 of the same part presents data on fast relaxation processes in the same objects. In the second part, Tables 3 and 4, as well as the following text, contain similar information about silicon quantum dots. Data on photoprocesses in quantum dots formed by direct-gap semiconductors are collected in the third part. Data on the photoluminescence yields, decay times, and relaxation processes are listed in Tables 5 and 6. Particular attention in the present review is given to the effect that a change in the frequency of vibrations in the environment of a quantum dot has on the photoluminescence yields and the rate of relaxation processes between electronic levels in bands, which indicates that the inductive resonance mechanism of nonradiative transitions is applicable to these systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Erratum to: Measurements of higher-order cumulants of multiplicity and net-electric charge distributions in inelastic proton-proton interactions by NA61/SHINE

This Erratum replaces, due to a discovery of coding mistakes, the following quantities: κ 3 /κ 1 of the h + − h − distribution presented in Fig. 6 and Table 6, κ 4 listed in Table 4, and $\hat{C}$ 4 presented in Fig. 7 and Table 5. All mentioned figures and tables were updated.

High-Energy Particle Collision Data Analysis↗

Co-PylotDB - A Python-Based Single-Window User Interface for Transmitting Information to a Database

Co-PylotDB, written completely in Python, provides a user interface (UI) with which to select user and data file(s), directories, and file content, and provide or capture various other information for sending data collected from running any computer program to a pre-formatted database table for persistent storage. The interface allows the user to select input, output, make, source, executable, and qsub files. It also provides fields for specifying the machine name on which the software was run, capturing compile and execution lines, and listing relevant user comments. Data automatically captured by Co-PylotDB and sent to the database are user, current directory, local hostname, current date, and time of send. The UI provides fields for logging into a local or remote database server, specifying a database and a table, and sending the information to the selected database table. If a server is not available, the UI provides for saving the command that would have saved the information to a database table for either later submission or for sending via email to a collaborator who has access to the desired database.

Barnette, DanielW.↗

AutoBEM-DynamicArchetypes

Automatic Building Energy Modeling (AutoBEM, https://bit.ly/AutoBEM) has been used to create an OpenStudio and EnergyPlus building energy model of 122.9 million U.S. buildings (https://bit.ly/ModelAmerica). Simulating and analyzing a model of every building for large areas (e.g. cities) is often not feasible. This dynamic archetyping capability uses a representative building and calculates a floor-space multiplier that allows millions of buildings to be represented by less than 100 buildings. This script (WRF_Archetypes_Parallel.py) calculates these building archetypes for each of the grid cells from a Weather Research and Forecasting (WRF) model in a parallel fashion. The script works by looping through each of the grid cells in the shapefile in parallel, spatially joining the building metadata table to each grid cell, aggregating relevant archetypes and calculating necessary statistics related to area and number of buildings in each cell. The output is a table (.csv) in which each row is an archetype building with properties about that building as well as statistics that relate that building to the total cell (such as an area multiplier). The following inputs are required: WRF zone shapefile (.shp) (wrf-grids-origin_Vegas_Select_100.geojson) The projection of the shapefile ("EPSG:XXXX") Input table containing building metadata for area corresponding to shapefile (.csv) (https://zenodo.org/record/4552901#.YZQEotDMJPY - ClarkCounty2.csv) The number of cores that will be parallelized (integer) The output file name for the archetype table (.csv) Sample command line inputs: python3 ~/WRF_Archetypes_Parallel.py -i ~/wrf-grids-origin_Vegas_Select_100.geojson -c ~/ClarkCounty2.csv -o ~/OutputArchetypes.csv -j 72 -e EPSG:4326 Using Geopandas Version 0.9.0

Bass, Brett (0000000240988434)↗

Knowledge Oriented Graph Unified Transformer (KOGUT) v0.1

KOGUT — Knowledge Oriented Graph Unified Transformer KOGUT implements the Relational Graph Transformer (RelGT) architecture for knowledge graph link prediction in biological domains, with a primary focus on microbial growth media prediction. While the original RelGT (arXiv:2505.10960) targets relational tables, time series, and multi-table databases, KOGUT adapts this architecture for heterogeneous biological knowledge graphs, providing first-in-class AI predictive models for microbial cultivation. Key Adaptations Beyond Original RelGT: - Knowledge Graph Focus: Applied to biological KGs with semantic node types (taxa, chemicals, media, phenotypes, environments) versus generic relational database tables, trained on the KG-Microbe knowledge graph (1.3M entities, 2.9M edges, 24 relation types). - Multimodal Node Encoding: Integrates node labels, categories, descriptions, and synonyms from KG metadata through learned embedding layers—adapting relational column features to graph node attributes with textual semantics. - Extended K-Hop Subgraph Strategy: Optimized neighborhood sampling (3-hop default, configurable up to 200 nodes) tuned for sparse biological networks, building on the original local-global attention framework with biological relation preservation. - Biolink Predicate Preservation: Type-specific transformations for 24 biological edge semantics (occurs_in, consumes, produces, has_phenotype, subclass_of) beyond standard relational foreign keys, enabling multi-relation link prediction. - Inductive Learning Support: Enables zero-shot predictions for novel taxa through feature-based embeddings (temperature, oxygen requirements, gram stain, cell shape), extending the original transductive relational benchmark scope to uncultured microorganisms. CheapSOTA Performance Optimizations (This Distribution): - VQ-EMA Centroid Attention: Vector quantization with exponential moving average for improved global context modeling (+5-10% MRR improvement). - HDF5 Precomputed Data Loading: One-time preprocessing of k-hop subgraphs to eliminate redundant graph traversals (2-5× training speedup). - Distributed Data Parallel Training: Multi-GPU support for scaling to larger knowledge graphs (tested on 4× NVIDIA A100 GPUs at NERSC Perlmutter). - Mixed Precision Training: Automatic mixed precision (AMP) for memory efficiency and faster training. Advantages Over Standard Knowledge Graph Embedding Models: Combines RelGT's proven multi-element tokenization (features, type, hop, structure) with graph-native biological representations, enabling interpretable link prediction across heterogeneous entities that standard embedding models (TransE, RotatE, ComplEx) and table-based transformers cannot directly model. Achieves near-perfect performance on microbial growth media prediction (MRR: 0.9966, Precision@1: 0.9932, Hit@10: 1.0000) while maintaining explainability through attention-based reasoning over biological pathways. Training Data: - KG-Microbe merged knowledge graph: 1,379,337 nodes, 2,960,472 edges - 24 biological relation types including taxonomic hierarchies, metabolic interactions, phenotype associations, and environmental relationships - Primary prediction task: Growth media suitability for microbial taxa (biolink:occurs_in, 50K edges) - Multi-relation capability: Predicts links for any of the 24 relation types, including chemical consumption/production, phenotype associations, and taxonomic classification Citation: Original RelGT Architecture: Dwivedi et al., "Relational Graph Transformer", arXiv:2505.10960, 2025 KOGUT Implementation: Knowledge Oriented Graph Unified Transformer for Microbial Growth Media Prediction Developed at Lawrence Berkeley National Laboratory (LBNL) Trained on NERSC Perlmutter supercomputer

Joachimiak, Marcin [Lawrence Berkeley National Lab↗

Disorder-induced magnetoelastic behaviors of MnTexSbyBi1-x-y alloys

This dataset contains input and output files from density functional theory (DFT) simulations used to study the disorder-induced magnetoelastic behaviors of MnTexSbyBi1-x-y (0 ≤ x + y ≤ 1) alloys and their binary end members MnTe, MnSb, and MnBi. The alloys adopt the hexagonal NiAs-type (nickeline) structure and span ternary (MnTexSb1-x, MnTexBi1-x, MnBixSb1-x), and quaternary compositions across the full MnTe–MnSb–MnBi composition triangle. For each alloy composition, the dataset provides DFT calculations in three magnetic configurations: A-type antiferromagnetic (AFM), C-type AFM, and ferromagnetic (FM). Every magnetic configuration folder contains the fully relaxed crystal structure (CONTCAR), VASP input parameters (INCAR), and the main VASP output file (OUTCAR), from which total electronic energies, Mn magnetic moments, lattice parameters, and percent volume changes between magnetic states are extracted. These data are used to construct compositional phase diagrams, evaluate thermodynamic stability (formability), and map magnetoelastic responses across the alloy space. For A-type AFM and FM configurations, additional data are provided as follows: (i) FORCE_CONSTANTS and thermal_properties.yaml files at the top level of A-type_AFM/ and FM/ folders — present only for compositions marked with an asterisk (*) in Table I of the main text. These are derived from Phonopy finite-displacement calculations on full disordered 128-atom supercells and provide vibrational free energy, entropy (Svib)contribution from explicit disorder calculations. (Table I of the associated main manuscript) (ii) A VCA/ subfolder within A-type_AFM/ and FM/, containing FORCE_CONSTANTS and thermal_properties.yaml from Virtual Crystal Approximation phonon calculations (without spin-orbit coupling). VCA data are available for all compositions and are used to estimate vibrational contributions to the Gibbs free energy across the full composition space. (iii) A SOC/ subfolder containing CONTCAR, INCAR, and OUTCAR from spin-orbit coupling calculations, providing relativistic corrections to electronic energies and lattice parameters (Tables S2–S3 of the SM, and Table I of the main manuscript). (iv) A SOC/VCA/ subfolder containing FORCE_CONSTANTS and thermal_properties.yaml from VCA phonon calculations performed within the SOC framework, combining relativistic and vibrational thermodynamic corrections. The computed properties are used to map the AFM–FM magnetic crossover near MnTe0.75Sb0.25, demonstrate disorder- and spin-induced phonon broadening, identify a semiconductor-to-metal crossover, and quantify the pronounced magnetoelastic volume response near the magnetic phase boundary.

36 MATERIALS SCIENCE↗

Fallon FORGE: Well Log Database

Master well database for all logs and other well data pertaining to the Fallon FORGE site. Tables are formatted in NGDS Teir 3 schema where appropriate; redundancies between tables are omitted, and should be queried off of the main WellHeader table. All relationships are set on the "HeaderURI" primary key. Tables: WellHeader - well locations and information ChemFluid - aqueous chemistry analyses ChemRock - rock chemistry analyses DensityCore - rock densities from core FracturesInduced - induced borehole fractures FracturesNatural - natural borehole factures LithIntercepts - lithology picks from cuttings and core MagSuscCore - magnetic susceptibility for core samples MagSuscPmag - magnetic susceptibility for pmag samples PTSLogs - pressure-temperature-spin logs WirelineLogs - digital wireline logs (21-31 only)

15 GEOTHERMAL ENERGY↗

NGEE Arctic Phase 4 Plant Functional Type Framework for Pan-Arctic Vegetation

The NGEE-Arctic research team identified a common set of hierarchical plant functional types (PFTs) for pan-arctic vegetation that we will use across our research activities. Interdisciplinary work within a large team requires agreement regarding levels of functional organization so that knowledge, data, and technologies can be shared and combined effectively. The team has identified plant functional types as a crucial area where such interoperability is needed. PFTs are used to represent plant pools and fluxes within models, summarize observational data, and map vegetation across the landscape. Within each of these applications, varying levels of PFT specificity are needed according to the specific scientific research goal, computational limitations, and data availability. By agreeing on a specific hierarchical framework for grouping variables in our vegetation data, we ensure the resulting research products will be robust, flexible, and scalable. In this document, we lay out the agreed upon PFT framework with definitions and references to existing literature. Table 1 included in the "NGA700_Phase4PFTFramework_about*" file outlines the relationship between NGEE-Arctic Phase 4, Tier 1 PFTs and the PFTs used within prominent arctic literature as well as publications by the NGEE-Arctic team during phases 1-3.This dataset consists of a table detailing a hierarchical PFT framework that spans 4 tiers with the most granular PFTs listed in tier 1 and the most general PFTs in tier 4. The PFTs within each tier has a single column in the dataset where the PFTs are named and a separate column where the characteristics used to define that PFT are listed. Grey fill of the cells is used to indicate where a given PFT starts to “lose” tier 1 details as you look from left to right. Note the excel file has merged cells to indicate grouping of PFTs across the Tiers- it will not translate into a delimited filetype (.csv, .txt, etc) without modification thus the hierarchical PFT framework table is available in three different file formats: 1) NGA700_Phase4PTS.xlsx – maintains the merged cells and grey fill; 2) NGA700_Phase4PTS.csv – merged cells are split, and grey fill is removed; 3) NGA700_Phase4PTS.pdf – image of the table with merged cells and grey fill. Metadata document included as a *.pdf and file-level metadata and data dictionary as *.csv files.

54 ENVIRONMENTAL SCIENCES↗