Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

A review of nanostructured based radiation sensors for neutron

Currently radiation sensors with various mechanisms such as radio thermo luminescence, radiographic and radiochromic film, semiconductor and ionization have been used for the detection of nuclear radiation. Sensitivity, handling procedure, heating condition, energy response, nonlinearity, polarization, non-uniform electric field, high bias voltage and spatial resolution due to large physical size are some of the key issues faced by these sensors. Due to the excellent electrical and mechanical properties, nanostructured materials such as carbon nanotubes (CNTs) have been researched as sensing elements in the sensors to overcome the mentioned problems. However CNTs are found to pose different problems, arising from the uncontrolled helicity and small cross-sectional area. Therefore, alternative sensing elements are still been sought after and the possibility of using boron nitride nanotubes for sensing neutron is considered in this review.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded ultrasound sensor in a silicon-on-insulator photonic platform

A miniaturized ultrasound sensor is demonstrated in a silicon-on-insulator platform. The sensor is based on a π-phase-shifted Bragg grating formed by waveguide corrugation. Ultrasound detection is performed by monitoring shifts in the resonance frequency of the grating using pulse interferometry. The device is characterized by measuring its response to a wideband acoustic point source generated using the optoacoustic effect. Experimental results show that the sensor's response is dominated by the formation of surface acoustic waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of annealing on proton irradiated AlGaN/GaN based micro-Hall sensors

The effect of annealing at 673 K on irradiated micro-Hall sensors irradiated with protons at 380keV and fluences of 10{sup 14}, 10{sup 15} and 10{sup 16} protons/cm{sup 2} is reported. Cathodoluminescence measurements were carried out at room temperature before and after annealing and showed improvement in the band edge band emission of the GaN layer. After annealing a sensor irradiated by 10{sup 15} protons/cm{sup 2} the device became operational with improvements in its magnetic sensitivity. All irradiated sensors showed improvement in their electrical characteristics after annealing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of intrinsic magnetostriction on tube-topology magnetoelectric sensors with high magnetic field sensitivity

Three quasi-one-dimensional magnetoelectric (ME) magnetic field sensors, each with a different magnetostrictive wire material, were investigated in terms of sensitivity and noise floor. Magnetostrictive Galfenol, iron-cobalt-vanadium, and iron-nickel wires were examined. Sensitivity profiles, hysteresis effects, and noise floor measurements for both optimally biased and zero-biased conditions are presented. The FeNi wire (FN) exhibits high sensitivity (5.36 mV/Oe) at bias fields below 22 Oe and an optimal bias of 10 Oe, whereas FeGa wire (FG) exhibits higher sensitivity (6.89 mW/Oe) at bias fields >22 Oe. The sensor of FeCoV wire (FC) presents relatively low sensitivity (2.12 mV/Oe), due to low magnetostrictive coefficient. Each ME tube-topology sensor demonstrates relatively high sensitivity at zero bias field, which results from a magnetic shape anisotropy and internal strain of the thin magnetostrictive wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A resonant sensor composed of quartz double ended tuning fork and silicon substrate for digital acceleration measurement

Presented in this paper is a micro-resonant acceleration sensor based on the frequency shift of quartz double ended tuning fork (DETF). The structure is silicon substrate having a proof mass supported by two parallel flexure hinges as doubly sustained cantilever, with a resonating DETF located between the hinges. The acceleration normal to the chip plane induces an axial stress in the DETF beam and, in turn, a proportional shift in the beam resonant frequency. Substrate is manufactured by single-crystal silicon for stable mechanical properties and batch-fabrication processes. Electrodes on the four surfaces of DETF beam excite anti-phase vibration model, to balance inner stress and torque and imply a high quality factor. The sensor is simply packaged and operates unsealed in atmosphere for measurements. The tested natural frequency is 36.9 kHz and the sensitivity is 21 Hz/g on a nominally ±100 g device, which is in good agreement with analytical calculation and finite element simulation. The output frequency drifting is less than 0.5 Hz (0.0014% of steady output) within 1 h. The nonlinearity is 0.0019%FS and hysteresis is 0.0026%FS. The testing results confirm the feasibility of combining quartz DETF and silicon substrate to achieve a micro-resonant sensor based on simple processing for digital acceleration measurements.

36 MATERIALS SCIENCE↗

Breakdown voltage reduction by field emission in multi-walled carbon nanotubes based ionization gas sensor

Ionization gas sensors using vertically aligned multi-wall carbon nanotubes (MWCNT) are demonstrated. The sharp tips of the nanotubes generate large non-uniform electric fields at relatively low applied voltage. The enhancement of the electric field results in field emission of electrons that dominates the breakdown mechanism in gas sensor with gap spacing below 14 μm. More than 90% reduction in breakdown voltage is observed for sensors with MWCNT and 7 μm gap spacing. Transition of breakdown mechanism, dominated by avalanche electrons to field emission electrons, as decreasing gap spacing is also observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber-optic thermometry using thermal radiation from Tm end doped SiO{sub 2} fiber sensor

Fiber-optic thermometry based on temperature dependence of thermal radiation from Tm{sup 3+} ions was studied using Tm end doped SiO{sub 2} fiber sensor. Visible light radiation peaks due to f-f transition of Tm{sup 3+} ion were clearly observed at λ = 690 and 790 nm from Tm end doped SiO{sub 2} fibers sensor at the temperature above 600 °C. Thermal radiation peaks are assigned with f-f transition of Tm{sup 3+} ion, {sup 1}D{sub 2}-{sup 3}H{sub 6}, and {sup 1}G{sub 4}-{sup 3}H{sub 6}. Peak intensity of thermal radiation from Tm{sup 3+} ion increases with temperature. Intensity ratio of thermal radiation peaks at λ = 690 nm against that at λ = 790 nm, I{sub 790/690}, is suitable for the temperature measurement above 750 °C. Two-dimensional temperature distribution in a flame is successfully evaluated by Tm end doped SiO{sub 2} fiber sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometrical optimization of a local ballistic magnetic sensor

We have developed a highly sensitive local magnetic sensor by using a ballistic transport property in a two-dimensional conductor. A semiclassical simulation reveals that the sensitivity increases when the geometry of the sensor and the spatial distribution of the local field are optimized. We have also experimentally demonstrated a clear observation of a magnetization process in a permalloy dot whose size is much smaller than the size of an optimized ballistic magnetic sensor fabricated from a GaAs/AlGaAs two-dimensional electron gas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high precision, compact electromechanical ground rotation sensor

We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10{sup −11}m/√( Hz ). We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10{sup −9} rad /√( Hz ) at 10 mHz and 6.4 × 10{sup −10} rad /√( Hz ) at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

42 ENGINEERING↗

A cavity ring-down spectroscopy sensor for real-time Hall thruster erosion measurements

A continuous-wave cavity ring-down spectroscopy sensor for real-time measurements of sputtered boron from Hall thrusters has been developed. The sensor uses a continuous-wave frequency-quadrupled diode laser at 250 nm to probe ground state atomic boron sputtered from the boron nitride insulating channel. Validation results from a controlled setup using an ion beam and target showed good agreement with a simple finite-element model. Application of the sensor for measurements of two Hall thrusters, the H6 and SPT-70, is described. The H6 was tested at power levels ranging from 1.5 to 10 kW. Peak boron densities of 10 ± 2 × 10{sup 14} m{sup −3} were measured in the thruster plume, and the estimated eroded channel volume agreed within a factor of 2 of profilometry. The SPT-70 was tested at 600 and 660 W, yielding peak boron densities of 7.2 ± 1.1 × 10{sup 14} m{sup −3}, and the estimated erosion rate agreed within ∼20% of profilometry. Technical challenges associated with operating a high-finesse cavity in the presence of energetic plasma are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High sensitivity gas sensor based on high-Q suspended polymer photonic crystal nanocavity

We present high-sensitivity, multi-use optical gas sensors based on a one-dimensional photonic crystal cavity. These devices are implemented in versatile, flexible polymer materials which swell when in contact with a target gas, causing a measurable cavity length change. This change causes a shift in the cavity resonance, allowing precision measurements of gas concentration. We demonstrate suspended polymer nanocavity sensors and the recovery of sensors after the removal of stimulant gas from the system. With a measured quality factor exceeding 10{sup 4}, we show measurements of gas concentration as low as 600 parts per million (ppm) and an experimental sensitivity of 10 ppm; furthermore, we predict detection levels in the parts-per-billion range for a variety of gases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A microfabricated fringing field capacitive pH sensor with an integrated readout circuit

This work presents a microfabricated fringe-field capacitive pH sensor using interdigitated electrodes and an integrated modulation-based readout circuit. The changes in capacitance of the sensor result from the permittivity changes due to pH variations and are converted to frequency shifts using a crossed-coupled voltage controlled oscillator readout circuit. The shift in resonant frequency of the readout circuit is 30.96 MHz for a change in pH of 1.0–5.0. The sensor can be used for the measurement of low pH levels, such as gastric acid, and can be integrated with electronic pills. The measurement results show high repeatability, low noise, and a stable output.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent results and challenges in development of metallic Hall sensors for fusion reactors

Reliable and precise diagnostic of local magnetic field is crucial for successful operation of future thermonuclear fusion reactors based on magnetic confinement. Magnetic sensors at these devices will experience an extremely demanding operational environment with large radiation and thermal loads in combination with required long term, reliable, and service-free performance. Neither present day commercial nor laboratory measurement systems comply with these requirements. Metallic Hall sensors based on e.g. copper or bismuth could potentially satisfy these needs. We present the technology for manufacturing of such sensors and some initial results on characterization of their properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Touch sensors based on planar liquid crystal-gated-organic field-effect transistors

We report a tactile touch sensor based on a planar liquid crystal-gated-organic field-effect transistor (LC-g-OFET) structure. The LC-g-OFET touch sensors were fabricated by forming the 10 μm thick LC layer (4-cyano-4{sup ′}-pentylbiphenyl - 5CB) on top of the 50 nm thick channel layer (poly(3-hexylthiophene) - P3HT) that is coated on the in-plane aligned drain/source/gate electrodes (indium-tin oxide - ITO). As an external physical stimulation to examine the tactile touch performance, a weak nitrogen flow (83.3 μl/s) was employed to stimulate the LC layer of the touch device. The LC-g-OFET device exhibited p-type transistor characteristics with a hole mobility of 1.5 cm{sup 2}/Vs, but no sensing current by the nitrogen flow touch was measured at sufficiently high drain (V{sub D}) and gate (V{sub G}) voltages. However, a clear sensing current signal was detected at lower voltages, which was quite sensitive to the combination of V{sub D} and V{sub G}. The best voltage combination was V{sub D} = −0.2 V and V{sub G} = −1 V for the highest ratio of signal currents to base currents (i.e., signal-to-noise ratio). The change in the LC alignment upon the nitrogen flow touch was assigned as the mechanism for the present LC-g-OFET touch sensors.

36 MATERIALS SCIENCE↗

Quasi-static displacement calibration system for a “Violin-Mode” shadow-sensor intended for Gravitational Wave detector suspensions

This paper describes the design of, and results from, a calibration system for optical linear displacement (shadow) sensors. The shadow sensors were designed to detect “Violin-Mode” (VM) resonances in the 0.4 mm diameter silica fibre suspensions of the test masses/mirrors of Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave interferometers. Each sensor illuminated the fibre under test, so as to cast its narrow shadow onto a “synthesized split photodiode” detector, the shadow falling over adjacent edges of the paired photodiodes. The apparatus described here translated a vertically orientated silica test fibre horizontally through a collimated Near InfraRed illuminating beam, whilst simultaneously capturing the separate DC “shadow notch” outputs from each of the paired split photodiode detectors. As the ratio of AC to DC photocurrent sensitivities to displacement was known, a calibration of the DC response to quasi-static shadow displacement allowed the required AC sensitivity to vibrational displacement to be found. Special techniques are described for generating the required constant scan rate for the test fibre using a DC motor-driven stage, for removing “jitter” at such low translation rates from a linear magnetic encoder, and so for capturing the two shadow-notch signals at each micrometre of the test fibre's travel. Calibration, across the four detectors of this work, gave a vibrational responsivity in voltage terms of (9.45 ± 1.20) MV (rms)/m, yielding a VM displacement sensitivity of (69 ± 13) pm (rms)/√Hz, at 500 Hz, over the required measuring span of ±0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect-free ZnO nanorods for low temperature hydrogen sensor applications

Uniformly distributed and defect-free vertically aligned ZnO nanorods (NRs) with high aspect ratio are deposited on Si by sputtering technique. X-ray diffraction along with transmission electron microscopy studies confirmed the single crystalline wurtzite structure of ZnO. Absence of wide band emission in photoluminescence spectra showed defect-free growth of ZnO NRs which was further conformed by diamagnetic behavior of the NRs. H{sub 2} sensing mechanism based on the change in physical dimension of channel is proposed to explain the fast response (∼21.6 s) and recovery times (∼27 s) of ZnO NRs/Si/ZnO NRs sensors. Proposed H{sub 2} sensor operates at low temperature (∼70 °C) unlike the existing high temperature (>150 °C) sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photonic E-field sensor

We report on both theoretical and experimental studies of a photonic implementation of the electric (E-) field sensor using a probe made with all-dielectric RF-transparent elements. The geometrical dimensions of the electric field probe can be smaller than the wavelength of the measured electromagnetic field in the material. Our theoretical calculations show that the sensor allows detecting electric fields in a broad frequency range (100 Hz-20 GHz) with sensitivity better than 1 μV/[Hz{sup 1/2} m]. We demonstrate the sensor operating at X-band and validate the theoretical predictions.

36 MATERIALS SCIENCE↗

Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗