Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Sample mounts for microcrystal crystallography

Sample mounts (10) for mounting microcrystals of biological macromolecules for X-ray crystallography are prepared by using patterned thin polyimide films (12) that have curvature imparted thereto, for example, by being attached to a curved outer surface of a small metal rod (16). The patterned film (12) preferably includes a tip end (24) for holding a crystal. Preferably, a small sample aperture is disposed in the film for reception of the crystal. A second, larger aperture can also be provided that is connected to the sample aperture by a drainage channel, allowing removal of excess liquid and easier manipulation in viscous solutions. The curvature imparted to the film (12) increases the film's rigidity and allows a convenient scoop-like action for retrieving crystals. The polyimide contributes minimally to background and absorption, and can be treated to obtain desired hydrophobicity or hydrophilicity.

Thorne, Robert E.↗

Separation and Sealing of a Sample Container Using Brazing

A special double-wall container and a process for utilizing the container are being developed to enable (1) acquisition of a sample of material in a dirty environment that may include a biological and/or chemical hazard; (2) sealing a lid onto the inner part of the container to hermetically enclose the sample; (3) separating the resulting hermetic container from the dirty environment; and (4) bringing that hermetic container, without any biological or chemical contamination of its outer surface, into a clean environment. The process is denoted S(exp 3)B (separation, seaming, and sealing using brazing) because sealing of the sample into the hermetic container, separating the container from the dirty environment, and bringing the container with a clean outer surface into the clean environment are all accomplished simultaneously with a brazing operation.

Bar-Cohen, Yoseph↗

Preview of the NASA NNWG NDE Sample Preparation Handbook

This viewgraph presents a step-by-step how-to fabrication documentation of every kind of sample that is fabricated for MSFC by UA Huntsville, including photos and illustrations. The tabulation of what kind of samples are being fabricated for what NDE method, detailed instructions/documentation of the inclusion/creation of defects, detailed specifications for materials, processes, and equipment, case histories and/or experiences with the different fabrication methods and defect inclusion techniques, discussion of pitfalls and difficulties associated with sample fabrication and defect inclusion techniques, and a discussion of why certain fabrication techniques are needed as related to the specific NDE methods are included in this presentation.

Source record↗

Analytical Model of the Nonlinear Dynamics of Cantilever Tip-Sample Surface Interactions for Various Acoustic-Atomic Force Microscopies

A comprehensive analytical model of the interaction of the cantilever tip of the atomic force microscope (AFM) with the sample surface is developed that accounts for the nonlinearity of the tip-surface interaction force. The interaction is modeled as a nonlinear spring coupled at opposite ends to linear springs representing cantilever and sample surface oscillators. The model leads to a pair of coupled nonlinear differential equations that are solved analytically using a standard iteration procedure. Solutions are obtained for the phase and amplitude signals generated by various acoustic-atomic force microscope (A-AFM) techniques including force modulation microscopy, atomic force acoustic microscopy, ultrasonic force microscopy, heterodyne force microscopy, resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), and the commonly used intermittent contact mode (TappingMode) generally available on AFMs. The solutions are used to obtain a quantitative measure of image contrast resulting from variations in the Young modulus of the sample for the amplitude and phase images generated by the A-AFM techniques. Application of the model to RDF-AFUM and intermittent soft contact phase images of LaRC-cp2 polyimide polymer is discussed. The model predicts variations in the Young modulus of the material of 24 percent from the RDF-AFUM image and 18 percent from the intermittent soft contact image. Both predictions are in good agreement with the literature value of 21 percent obtained from independent, macroscopic measurements of sheet polymer material.

Cantrell, John H., Jr.↗

Total Water Content Measurements with an Isokinetic Sampling Probe

The NASA Glenn Research Center has developed a Total Water Content (TWC) Isokinetic Sampling Probe. Since it is not sensitive to cloud water particle phase nor size, it is particularly attractive to support super-cooled large droplet and high ice water content aircraft icing studies. The instrument is comprised of the Sampling Probe, Sample Flow Control, and Water Vapor Measurement subsystems. Analysis and testing have been conducted on the subsystems to ensure their proper function and accuracy. End-to-end bench testing has also been conducted to ensure the reliability of the entire instrument system. A Stokes Number based collection efficiency correction was developed to correct for probe thickness effects. The authors further discuss the need to ensure that no condensation occurs within the instrument plumbing. Instrument measurements compared to facility calibrations from testing in the NASA Glenn Icing Research Tunnel are presented and discussed. There appears to be liquid water content and droplet size effects in the differences between the two measurement techniques.

Reehorst, Andrew L.↗

Comparison of the Organic Composition of Cometary Samples with Residues Formed from the UV Irradiation of Astrophysical Ice Analogs

The NASA Stardust mission successfully collected material from Comet 81P/Wild 2 [1], including authentic cometary grains [2]. X-ray absorption near-edge structure (XANES) spectroscopy analysis of these samples indicates the presence of oxygen-rich and nitrogen-rich organic materials, which contain a broad variety of functional groups (carbonyls, C=C bonds, aliphatic chains, amines, arnides, etc.) [3]. One component of these organics appears to contain very little aromatic carbon and bears some similarity to the organic residues produced by the irradiation of ices of interstellar/cometary composition, Stardust samples were also recently shown to contain glycine, the smallest biological amino acid [4]. Organic residues produced froth the UV irradiation of astrophysical ice analogs are already known to contain a large suite of organic molecules including amino acids [5-7], amphiphilic compounds (fatty acids) [8], and other complex species. This work presents a comparison between XANES spectra measured from organic residues formed in the laboratory with similar data of cometary samples collected by the Stardust mission

Milam, S. N.↗

Implications of Microwave Holography Using Minimum Required Frequency Samples for Weakly- and Strongly-Scattering Indications

Microwave imaging techniques, an integral component of nondestructive testing and evaluation (NDTE), have received significant attention in the past decade. These techniques have included the implementation of synthetic aperture focusing (SAF) algorithms for obtaining high spatial resolution images. The next important step in these developments is the implementation of 3-D holographic imaging algorithms. These are well-known wideband imaging technique requiring a swept-frequency (i.e., wideband), which unlike SAF that is a single frequency technique, are not easily performed on a real-time basis. This is due to the fact that a significant number of data points (in the frequency domain) must be obtained within the frequency band of interest. This not only makes for a complex imaging system design, it also significantly increases the image-production time. Consequently in an attempt to reduce the measurement time and system complexity, an investigation was conducted to determine the minimum required number of frequency samples needed to image a specific object while preserving a desired maximum measurement range and range resolution. To this end the 3-D holographic algorithm was modified to use properlyinterpolated frequency data. Measurements of the complex reflection coefficient for several samples were conducted using a swept-frequency approach. Subsequently, holographical images were generated using data containing a relatively large number of frequency samples and were compared with images generated by the reduced data set data. Quantitative metrics such as average, contrast, and signal-to-noise ratio were used to evaluate the quality of images generated using reduced data sets. Furthermore, this approach was applied to both weakly- and strongly-scattering indications. This paper presents the methods used and the results of this investigation.

Fallahpour, M.↗

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting that no further leaks of the SM air conditioner have occurred.

James, John T.↗

Solar System Samples for Research, Education, and Public Outreach

In the next two years, during the NASA Year of the Solar System, spacecraft from NASA and our international partners will; encounter a comet, orbit asteroid 4 Vesta, continue to explore Mars with rovers, and launch robotic explorers to the Moon and Mars. We have pieces of all these worlds in our laboratories, and their continued study provides incredibly valuable "ground truth" to complement space exploration missions. Extensive information about these unique materials, as well as actual lunar samples and meteorites, are available for display and education. The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.

Allen, J.↗

A Howardite-Eucrite-Diogenite (HED) Meteorite Compendium: Summarizing Samples of ASteroid 4 Vesta in Preparation for the Dawn Mission

The Howardite-Eucrite-Diogenite (HED) suite of achondritic meteorites, thought to originate from asteroid 4 Vesta, has recently been summarized into a meteorite compendium. This compendium will serve as a guide for researchers interested in further analysis of HEDs, and we expect that interest in these samples will greatly increase with the planned arrival of the Dawn Mission at Vesta in August 2011. The focus of this abstract/poster is to (1) introduce and describe HED samples from both historical falls and Antarctic finds, and (2) provide information on unique HED samples available for study from the Antarctic Meteorite Collection at JSC, including the vesicular eucrite PCA91007, the olivine diogenite EETA79002, and the paired ALH polymict eucrites.

Garber, J. M.↗

A Comparison of Multivariate and Pre-Processing Methods for Quantitative Laser-Induced Breakdown Spectroscopy of Geologic Samples

The ChemCam instrument selected for the Curiosity rover is capable of remote laser-induced breakdown spectroscopy (LIBS).[1] We used a remote LIBS instrument similar to ChemCam to analyze 197 geologic slab samples and 32 pressed-powder geostandards. The slab samples are well-characterized and have been used to validate the calibration of previous instruments on Mars missions, including CRISM [2], OMEGA [3], the MER Pancam [4], Mini-TES [5], and Moessbauer [6] instruments and the Phoenix SSI [7]. The resulting dataset was used to compare multivariate methods for quantitative LIBS and to determine the effect of grain size on calculations. Three multivariate methods - partial least squares (PLS), multilayer perceptron artificial neural networks (MLP ANNs) and cascade correlation (CC) ANNs - were used to generate models and extract the quantitative composition of unknown samples. PLS can be used to predict one element (PLS1) or multiple elements (PLS2) at a time, as can the neural network methods. Although MLP and CC ANNs were successful in some cases, PLS generally produced the most accurate and precise results.

Anderson, R. B.↗

In-Situ XRF Measurements in Lunar Surface Exploration Using Apollo Samples as a Standard

Samples collected during the Apollo lunar surface missions were sampled and returned to Earth by astronauts with varying degrees of geological experience. The technology used in these EVAs, or extravehicular activities, included nothing more advanced than traditional terrestrial field instruments: rock hammer, scoop, claw tool, and sample bags. 40 years after Apollo, technology is being developed that will allow for a high-resolution geochemical map to be created in the field real-time. Handheld x-ray fluorescence (XRF) technology is one such technology. We use handheld XRF to enable a broad in-situ characterization of a geologic site of interest based on fairly rapid techniques that can be implemented by either an astronaut or a robotic explorer. The handheld XRF instrument we used for this study was the Innov-X Systems Delta XRF spectrometer.

Young, Kelsey E.↗

Sampling the Uppermost Surface of Airless Bodies

The uppermost surface of an airless body is a critical source of ground-truth information for the various remote sensing techniques that only penetrate nanometers to micrometers into the surface. Such samples will also be vital for understanding conditions at the surface and acquiring information about how the body interacts with its environment, including solar wind interaction, grain charging and levitation [1]. Sampling the uppermost surface while preserving its structure (e.g. porosity, grain-to-grain contacts) however, is a daunting task that has not been achieved on any sample return mission to date.

Noble, S. K.↗

The Importance of Sample Return in Establishing Chemical Evidence for Life on Mars or Other Solar System Bodies

The search for evidence of life on Mars and elsewhere will continue to be one of the primary goals of NASA s robotic exploration program over the next decade. NASA and ESA are currently planning a series of robotic missions to Mars with the goal of understanding its climate, resources, and potential for harboring past or present life. One key goal will be the search for chemical biomarkers including complex organic compounds important in life on Earth. These include amino acids, the monomer building blocks of proteins and enzymes, nucleobases and sugars which form the backbone of DNA and RNA, and lipids, the structural components of cell membranes. Many of these organic compounds can also be formed abiotically as demonstrated by their prevalence in carbonaceous meteorites [1], though, their molecular characteristics may distinguish a biological source [2]. It is possible that in situ instruments may reveal such characteristics, however, return of the right sample (i.e. one with biosignatures or having a high probability of biosignatures) to Earth would allow for more intensive laboratory studies using a broad array of powerful instrumentation for bulk characterization, molecular detection, isotopic and enantiomeric compositions, and spatially resolved chemistry that may be required for confirmation of extant or extinct Martian life. Here we will discuss the current analytical capabilities and strategies for the detection of organics on the Mars Science Laboratory (MSL) using the Sample Analysis at Mars (SAM) instrument suite and how sample return missions from Mars and other targets of astrobiological interest will help advance our understanding of chemical biosignatures in the solar system.

Glavin, D. P.↗

Airborne Observation of the Hayabusa Sample Return Capsule Re-Entry

The Japan Aerospace Exploration Agency (JAXA) recently completed their Hayabusa asteroid exploration mission. Launched in 2003, Hayabusa made contact with, and retrieved a sample from, the near-Earth asteroid Itokawa in 2005. The sample return capsule (SRC) re-entered over the Woomera Test Range (WTR) in southern Australia on June 13, 2010, at approximately 11:21 pm local time (09:51 UTC). The SRC re-entry velocity was 12.2 km/s, making it the second-fastest Earth return velocity behind NASA s Stardust sample return capsule re-entry in 2006. From a space technology development perspective, Hayabusa s re-entry functioned as a rare flight experiment of an entry vehicle and its thermal protection system. In collaboration with the SETI Institute, NASA deployed its DC-8 airborne laboratory and a team of international researchers to Australia to observe the re-entry of the SRC. The use of an airborne platform enables observation above most clouds and weather and greatly diminishes atmospheric absorption of the optical signals. The DC-8 s flight path was engineered and flown to provide a view of the spacecraft that bracketed the heat pulse to the capsule. A suite of imaging instruments on board the DC-8 successfully recorded the luminous portion of the re-entry event. For approximately 70 seconds, the spectroscopic and radiometric instruments acquired images and spectra of the capsule, its wake, and destructive re-entry of the spacecraft bus. Figure 1 shows a perspective view of the WTR, the SRC re-entry trajectory, and the flight path of the DC-8. The SRC was jettisoned from the spacecraft bus approximately 3 hours prior to entry interface. Due to thruster failures on the spacecraft, it could not be diverted from the entry path and followed the trajectory of the SRC, where it burned up in the atmosphere between approximately 100 and 50 km altitude. Fortuitously, the separation distance between the spacecraft and SRC was sufficient to clearly resolve the SRC from the debris field of the burning spacecraft. Figure 2 shows a frame from a high-definition television camera on board the aircraft and denotes the locations of the SRC and spacecraft bus debris.

Grinstead, Jay H.↗

Search for Chemical Biomarkers on Mars Using the Sample Analysis at Mars Instrument Suite on the Mars Science Laboratory

One key goal for the future exploration of Mars is the search for chemical biomarkers including complex organic compounds important in life on Earth. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) will provide the most sensitive measurements of the organic composition of rocks and regolith samples ever carried out in situ on Mars. SAM consists of a gas chromatograph (GC), quadrupole mass spectrometer (QMS), and tunable laser spectrometer to measure volatiles in the atmosphere and released from rock powders heated up to 1000 C. The measurement of organics in solid samples will be accomplished by three experiments: (1) pyrolysis QMS to identify alkane fragments and simple aromatic compounds; pyrolysis GCMS to separate and identify complex mixtures of larger hydrocarbons; and (3) chemical derivatization and GCMS extract less volatile compounds including amino and carboxylic acids that are not detectable by the other two experiments.

Glavin, D. P.↗

Sustainable Mars Sample Return

The proposed Mars sample return mission will be completed using natural Martian resources for the majority of its operations. The system uses the following technologies: In-Situ Propellant Production (ISPP), a methane-oxygen propelled Mars Ascent Vehicle (MAV), a carbon dioxide powered hopper, and a hydrogen fueled balloon system (large balloons and small weather balloons). The ISPP system will produce the hydrogen, methane, and oxygen using a Sabatier reactor. a water electrolysis cell, water extracted from the Martian surface, and carbon dioxide extracted from the Martian atmosphere. Indigenous hydrogen will fuel the balloon systems and locally-derived methane and oxygen will fuel the MAV for the return of a 50 kg sample to Earth. The ISPP system will have a production cycle of 800 days and the estimated overall mission length is 1355 days from Earth departure to return to low Earth orbit. Combining these advanced technologies will enable the proposed sample return mission to be executed with reduced initial launch mass and thus be more cost efficient. The successful completion of this mission will serve as the next step in the advancement of Mars exploration technology.

Alston, Christie↗

Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing

The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

Johnson, Kenneth L.↗