Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

SAM Code Enhancement, Validation, and Reference Model Development for Fluoride-salt-cooled High-temperature Reactors

The System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report summarizes recent progress under DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program in SAM code development, demonstration, and validation to support transient safety analysis of Fluoride-salt-cooled High-temperature Reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The National Renewable Energy Laboratory (NREL) in collaboration with Massachusetts Institute of Technology (MIT), Universidad Pontificia Comillas (Comillas-IIT, Spain) and GE Grid Solutions, is working on an ARPA-E GRID DATA project, titled Smart-DS, to create: 1) High-quality, realistic, synthetic distribution network models, and 2) Advanced tools for automated scenario generation based on high-resolution weather data and generation growth projections. Through these advancements, the Smart-DS project is envisioned to accelerate the development, testing, and adoption of advanced algorithms, approaches, and technologies for sustainable and resilient electric power systems, especially in the realm of U.S. distribution systems. This talk will present the goals and overall approach of the Smart-DS project, including the process of creating the synthetic distribution datasets using reference network model (RNM) and the comprehensive validation process to ensure network realism, feasibility, and applicability to advanced use cases. The talk will provide demonstrations of early versions of synthetic models, along with the lessons learnt from expert engagements to enhance future iterations. Finally, the scenario generation framework, its development plans, and co-ordination with GRID DATA repository teams to house these datasets for public access will also be discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GIF Very High Temperature Reactor: Proliferation Resistance and Physical Protection White Paper

This report is part of a series of six white papers, prepared jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the six System Steering Committees (SSCs) and provisional System Steering Committees (pSSCs). This publication is an update to a similar series published in 2011 presenting the status of Proliferation Resistance & Physical Protection (PR&PP) characteristics for each of the six systems selected by the Generation IV International Forum (GIF) for further research and development, namely: the Sodium-cooled fast Reactor (SFR), the Very high temperature reactor (VHTR), the gas-cooled fast reactor (GFR), the Molten salt reactor (MSR) and the Supercritical water–cooled reactor (SCWR). This white paper represents the status of Proliferation Resistance and Physical Protection (PR&PP) characteristics for the Very-High-Temperature Reactor (VHTR) reference designs selected by the Generation IV International Forum (GIF) VHTR System Steering Committee (SSC). The intent is to generate preliminary information about the PR&PP features of the VHTR reactor technology and to provide insights for optimizing their PR&PP performance for the benefit of VHTR system designers. It updates the VHTR analysis published in the 2011 report “Proliferation Resistance and Physical Protection of the Six Generation IV Nuclear Energy Systems”, prepared Jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the System Steering Committees and provisional System Steering Committees of the Generation IV International Forum, taking into account the evolution of both the systems, the GIF R&D activities, and an increased understanding of the PR&PP features. The white paper, prepared jointly by the GIF PRPPWG and the GIF VHTR SSC, follows the high-level paradigm of the GIF PR&PP Evaluation Methodology to investigate the key points of PR&PP features extracted from the reference designs of VHTRs under consideration in various countries. A major update from the 2011 report is an explicit distinction between prismatic block-type VHTRs and pebble-bed VHTRs. The white paper also provides an overview of the TRISO fuel and fuel cycle. For PR, the document analyses and discusses the proliferation resistance aspects in terms of robustness against State-based threats associated with diversion of materials, misuse of facilities, breakout scenarios, and production in clandestine facilities. Similarly, for PP, the document discusses the robustness against theft of material and sabotage by non-State actors. The document follows a common template adopted by all the white papers in the updated series.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A groundwater salinity hotspot and its connection to an intermittent stream identified by environmental tracers (Mt Lofty Ranges, South Australia)

High and variable levels of salinity were investigated in an intermittent stream in a high-rainfall area (∼800 mm/year) of the Mt. Lofty Ranges of South Australia. The groundwater system was found to have a local, upslope saline lens, referred to here as a groundwater salinity ‘hotspot’. Environmental tracer analyses (δ{sup 18}O, δ{sup 2}H, {sup 87/86}Sr, and major elements) of water from the intermittent stream, a nearby permanent stream, shallow and deep groundwater, and soil-water/runoff demonstrate seasonal groundwater input of very saline composition into the intermittent stream. This input results in large salinity increases of the stream water because the winter wet-season stream flow decreases during spring in this Mediterranean climate. Furthermore, strontium and water isotope analyses demonstrate: (1) the upslope-saline-groundwater zone (hotspot) mixes with the dominant groundwater system, (2) the intermittent-stream water is a mixture of soil-water/runoff and the upslope saline groundwater, and (3) the upslope-saline-groundwater zone results from the flushing of unsaturated-zone salts from the thick clayey regolith and soil which overlie the metamorphosed shale bedrock. The preferred theory on the origin of the upslope-saline-groundwater hotspot is land clearing of native deep-rooted woodland, followed by flushing of accumulated salts from the unsaturated zone due to increased recharge. This cause of elevated groundwater and surface-water salinity, if correct, could be widespread in Mt. Lofty Ranges areas, as well as other climatically and geologically similar areas with comparable hydrogeologic conditions.

58 GEOSCIENCES↗

Combining Droop Curve Concepts with Control Systems for Wind Turbine Active Power Control: Preprint

Wind energy is becoming a larger portion of the global energy portfolio and wind penetration has increased dramatically in certain regions of the world. This increasing wind penetration has driven the need for wind turbines to provide active power control (APC) services to the local utility grid, as wind turbines do not intrinsically provide frequency regulation services that are common withtraditional generators. It is common for large scale wind turbines to be decoupled from the utility grid via power electronics, which allows the turbine to synthesize APC commands via control of the generator torque and blade pitch commands. Consequently, the APC services provided by a wind turbine can be more flexible than those provided by conventional generators. This paper focuses on thedevelopment and implementation of both static and dynamic droop curves to measure grid frequency and output delta power reference signals to a novel power set point tracking control system. The combined droop curve and power tracking controller is simulated and comparisons are made between simulations using various droop curve parameters and stochastic wind conditions. The tradeoffs involvedwith aggressive response to frequency events are analyzed. At the turbine level, simulations are performed to analyze induced structural loads. At the grid level, simulations test a wind plant's response to a dip in grid frequency.

17 WIND ENERGY↗

GIF Gas Cooled Fast Reactor: Proliferation Resistance and Physical Protection White Paper

This white paper represents the status of Proliferation Resistance and Physical Protection (PR&PP) characteristics for the Gas-cooled Fast reactor (GFR) reference designs selected by the Generation IV International Forum (GIF) GFR System Steering Committee (SSC). The intent is to generate preliminary information about the PR&PP features of the GFR reactor technology and to provide insights for optimizing their PR&PP performance for the benefit of GFR system designers. It updates the GFR analysis published in the 2011 report “Proliferation Resistance and Physical Protection of the Six Generation IV Nuclear Energy Systems”, prepared Jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the System Steering Committees and provisional System Steering Committees of the Generation IV International Forum, taking into account the evolution of both the systems, the GIF R&D activities, and an increased understanding of the PR&PP features. The white paper, prepared jointly by the GIF PRPPWG and the GIF GFR SSC, follows the high-level paradigm of the GIF PR&PP Evaluation Methodology to investigate the PR&PP features of the GIF GFR 2400 MWth reference design. The ALLEGRO reactor is also described. The EM2 and HEN MHR reactor are mentioned. An overview of fuel cycle for the GFR reference design and for the ALLEGRO reactor are provided. For PR, the document analyses and discusses the proliferation resistance aspects in terms of robustness against State-based threats associated with diversion of materials, misuse of facilities, breakout scenarios, and production in clandestine facilities. Similarly, for PP, the document discusses the robustness against theft of material and sabotage by non-State actors. The document follows a common template adopted by all the white papers in the updated series.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impacts of Topography-Based Subgrid Scheme and Downscaling of Atmospheric Forcing on Modeling Land Surface Processes in the Conterminous US

The effects of small-scale topography-induced land surface heterogeneity are not well represented in current Earth System Models (ESMs). In this study, a new topography-based subgrid structure referred to as topographic units (TGU) designed to better capture subgrid topographic effects, and methods to downscale atmospheric forcing to the land TGUs have been implemented in the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Effects of the subgrid scheme and downscaling methods on ELM simulated land surface processes are evaluated over the conterminous United States (CONUS). For this purpose, ELM simulations are performed using two configurations without (NoD ELM) and with (D ELM) downscaling, both using TGUs derived for the 0.5-degree grids and the same land surface parameters. Simulations using the two ELM configurations are compared over the CONUS domain, regional levels, and at observational sites (e.g., SNOTEL). The CONUS-level results suggest that D ELM simulates more snowfall and snow water equivalent (SWE), higher runoff, and less ET during spring and summer. Regional-level results suggest more pronounced impacts of downscaling over regions dominated by higher elevation TGUs and regions with maximum precipitation occurring during cool seasons. Results at the SNOTEL sites suggest that D ELM has superior capability of reproducing the observed SWE at 83% of the sites, with more pronounced performance over topographically heterogeneous TGUs with their maximum precipitation occurring during cool seasons. The results highlight the importance of improving representation of small-scale surface heterogeneity in ESMs and motivate future research to understand their effects on land-atmosphere interactions, streamflow, and water resources management over mountainous regions.

54 ENVIRONMENTAL SCIENCES↗

Endogenous Interface Pricing for Consistent Transmission–Distribution Co-Optimization With Discrete Distribution Controls

This paper proposes an endogenous interface pricing model for day-ahead transmission–distribution co-optimization that co-determines the interface locational marginal price (LMP) and the transmission–distribution exchange, ensuring price–dispatch consistency while optimally scheduling discrete distribution controls. The formulation couples a DC optimal power flow (OPF) with a branch-flow AC OPF that schedules distributed energy resources (DERs), tap-changer settings, capacitor banks (CBs), and multi-period energy storage systems (ESSs) under feeder voltage and current limits, and is solved as a mixed-integer second-order cone program (MISOCP). In a T14–D33 system, coordinated device scheduling recovers about 90% of the distribution-to-transmission export achievable in a reference case that ignores distribution network (DN) limits, while satisfying a 1.05 p.u. voltage upper bound. In a T39–D34/D37/D123 system, a sequential decoupled benchmark produces interface LMP distortions up to 12.5% and a 7.28% mismatch in net export energy, whereas the proposed model removes these distortions and the associated settlement mismatches. Second-order cone (SOC) relaxation gaps remain below $10^{-3}$ in all cases.

Noh, Seung-Gil↗

The Solar Influencer Next Door: Predicting Low-Income Solar Referrals and Leads

Increasing the adoption of solar among low-to-moderate income (LMI) households remains an important policy goal because of its promise to simultaneously reduce energy burden and support the just distribution of benefits of renewable energy. However, scaling LMI solar remains challenging due to affordability and access issues. Most existing LMI adoption has occurred under public-funded programs, highlighting the importance of increasing the cost-effectiveness of these programs at scale. We develop a new household-level data set on LMI solar lead acquisition, referrals, and adoption to understand the processes through which LMI solar uptake has occurred in California. Then, we develop models to predict two sub-mechanisms in the solar adoption process: whether an otherwise qualified lead becomes "lost" i.e. non-responsive to outreach and, for existing clients, whether they refer solar to others. For the program analyzed, participants received their solar system at no cost, which deemphasizes economic drivers of solar adoption and could differ from other program experiences. Both models substantially improved the accuracy of prediction relative to a baseline. Overall, we find that peer effects and solar economics are important to predicting referrals, and household demographic factors in lead loss prediction. Finally, we find that referrals are both the highest quality and largest source of LMI solar leads, providing a promising mechanism to expand LMI programs further.

customer acquisition costs↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

Transaction-Based Controls for Building-Grid Integration: VOLTTRON™

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) is supporting the development of a “transactional network” concept that supports energy, operational, and financial transactions between building systems (e.g., rooftop units -- RTUs), and the electric power grid using applications, or 'agents', that reside either on the equipment, on local building controllers, or in the Cloud. The transactional network vision is delivered using a real-time, scalable reference platform called VOLTTRON that supports the needs of the changing energy system. VOLTTRON is an agent execution and an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions.

DOE↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Perturbative universal state-selective correction for state-specific multi-reference coupled cluster methods

The implementation details of the universal state-selective (USS) multi-reference coupled cluster (MRCC) formalism with singles and doubles (USS(2)) are discussed on the example of several benchmark systems. We demonstrate that the USS(2) formalism is capable of improving accuracies of state specific multi-reference coupled-cluster (MRCC) methods based on the Brillouin-Wigner and Mukherjee’s sufficiency conditions. Additionally, it is shown that the USS(2) approach significantly alleviates problems associated with the lack of invariance of MRCC theories upon the rotation of active orbitals. We also discuss the perturbative USS(2) formulations that significantly reduce numerical overhead of the full USS(2) method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test Protocols for Advanced Inverter Interoperability Functions - Appendices

Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.

14 SOLAR ENERGY↗

Test Protocols for Advanced Inverter Interoperability Functions – Main Document

Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as some of these inverter capabilities are being incorporated in large demonstration and commercial projects. The test protocols are intended to be used to verify acceptable performance of inverters within the standard framework described in IEC TR 61850-90-7. These test protocols, as they are refined and validated over time, can become precursors for future certification test procedures for DER advanced grid support functions.

14 SOLAR ENERGY↗

Stability of a Mixed–Valence Hydrous Iron–Rich Oxide: Implications for Water Storage and Dynamics in the Deep Lower Mantle

Incorporation of water into mantle compositions can have significant effects on the phase relations in the systems. Here, we synthesized an iron-rich hexagonal hydrous phase (referred to as "HH1-phase") under the high pressure-temperature (P-T) conditions of the deep lower mantle and determined the crystal structure of the HH1-phase at 79 GPa using the multigrain crystallography method. The chemical formula obtained was Fe 12.76 O 18 H x (x ~ to 4.5) in the Fe-O-H system. To demonstrate the role of HH1-phase for water storage in multicomponent systems relevant to mantle compositions, we investigated the stability of HH1-phase in both MgO-rich pyrolitic and SiO 2 -rich basaltic compositions. Our results indicate that the HH1-phase serves as major water storage in a pyrolitic composition, whereas the Al-rich CaCl 2 -type δ-phase and SiO 2 phase are major water storage phases in a SiO 2 -rich basaltic composition. Incorporation of considerable amounts of SiO 2 , MgO, and Al 2 O 3 into the HH1-phase expands its stability field from 98 GPa in the Fe-Al-O-H system to at least 108 GPa (corresponding to similar to 2,400 km depth) in the Mg-Si-Al-Fe-O-H system. Plumes of hot upwelling rock rooted at the base of the lower mantle have been proposed as a possible origin of hotspot volcanoes. The hydrous Fe-rich HH1-phase, if included into the material of upwelling plumes, will decompose on its rising to the upper part of the lower mantle and release water. Our results should provide constraints on water storage in the deep lower mantle and have implications for deep mantle dynamics.

58 GEOSCIENCES↗

Development of Integrated Thermal Fluids Modeling Capability for MSRs

The DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad class of light-water and advanced reactor concepts. The research and development approach under thermal fluids technical area synergistically combines three length and time scales in a hierarchal multi-scale approach. To demonstrate the feasibility and capabilities of a multi-scale thermal fluids capability using these codes, a key joint effort has been pursued to develop an integrated system-and engineering-scale thermal fluids analysis capability with the MOOSE-based codes, through integration of SAM and Pronghorn, both based on the MOOSE framework. This report summarizes the progress in developing an integrated system- and engineering-scale thermal fluids analysis capability based on SAM and Pronghorn for molten salt reactors (MSRs), which gained significant interest in recently years. Two coupling approaches were studied, i.e. separate domain or domain-segregated coupling approach and the domain-overlapping approach. A series of coupled multi-physics models have been developed for a common reference molten salt fast reactor (MSFR) concept, ranging from standalone SAM system model to integrated SAM-Pronghorn-Griffin models. Both the steady state and the transient simulations are performed to the state-of-the-art simulation capabilities of NEAMS software suite in MSFR system applications. This report also covers further development and testing of the gas transport model in SAM for MSR modeling support. The presence of noncondensable gas in MSR systems would have strong impacts on fission gas removal and transport of noble metals throughout the system. Fission products removed through the off-gas system can also impact reactivity and can act as an additional point of heat removal. To ensure that the gas transport model is adequately tested, the supported modeling capabilities and features of SAM were identified, and a suite of tests were developed to test the model for each identified feature. Validation and UQ testing were also performed for the model and demonstrated that the buoyancy term, which was originally developed using non-salt/helium gas experimental data, can capture the experimental gas bubble velocity and diameter to within experimental and code uncertainty. An existing MSRE model was also modified in this work to include the gas transport model and to demonstrate the gas model behavior for realistic conditions of interest.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field testing of a convergent array of acoustic Doppler profilers for high-resolution velocimetry in energetic tidal currents

An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation.

Harding, Samuel F.↗