Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Correlation between magnetism and “dark stripes” in strained La{sub 1−x}Sr{sub x}CoO{sub 3} epitaxial films (0 ≤ x ≤ 0.1)

Using the technique of aberration-corrected scanning transmission electron microscopy, we performed a systematic analysis for the atomic lattice of the strained La{sub 1−x}Sr{sub x}CoO{sub 3} (0 ≤ x ≤ 0.1) epitaxial films, which have drawn a great attention in recent years because of their anomalous magnetism. Superstructures characterized by dark stripes are observed in the lattice image, evolving with combined Sr-doping and lattice strains. Fascinatingly, we found a close relation between the proportion of the Co ions in dark stripes and the saturation magnetization of the film: the latter grows linearly with the former. This result implies that the magnetism could be exclusively ascribed to the Co ions in dark stripes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

Raman scattering enhanced by plasmonic clusters and its application to single-molecule imaging

The optical response of the linear Au{sub 8} cluster is investigated by the linear response theory based on the density functional theory. It is revealed that the observed many peaks in the visible region originate from the interaction of the ideal plasmonic excitation along the molecular axis with the background d-electron excitations, i.e., the Landau damping. In spite of the existence of the damping, the Raman scattering is shown to be enhanced remarkably by the incident light resonant to the visible excitations. The novel imaging experiment with the atomic resolution is proposed by utilizing a plasmonic cluster as the probing tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-Resolved High Resolution Neutron Imaging Studies at the ORNL Spallation Neutron Source

Our evaluation of a high-resolution digital imaging detector capable of providing millisecond time resolution and high sensitivity for neutrons is presented. This detector is a modified version of the high-resolution -ray imager developed previously at Radiation Monitoring Devices, Inc. (RMD, Inc.), and consists of an Electron Multiplying Charge Coupled Device (EMCCD) attached to a neutron-sensitive scintillator via a fiberoptic taper. By virtue of its internal gain, the EMCCD permits high speed readout without introducing additional noise, thereby enabling high frame rate operation with an enhanced signal-to-noise ratio (SNR). Detector sensitivity is enhanced through the use of a back-thinned EMCCD, which provides high quantum efficiency over a typical emission range for many neutron-sensitive scintillators. Preliminary evaluations conducted at the Liquids Reflectometer beam port of the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) demonstrate that this new detector has the sensitivity to detect individual neutrons and the acquisition speed to perform energy-selective imaging with a temporal resolution of milliseconds. While substantial improvements in timing and imaging performance are planned, this prototype detector has already generated the first ever images of the SNS Liquids Reflectometer beam profile and was also used to demonstrate a technique for obtaining Bragg edge transmission imaging using energy-selective neutrons. The preliminary data, along with the detector design, evaluation, and planned developments are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing Quantum Yield via Local Symmetry Distortion in Lanthanide-Based Upconverting Nanoparticles

Lanthanide-based upconverting nanoparticles exhibit significant promise for solar energy generation, biological imaging, and security technologies but have not seen widespread adoption due to the prohibitively low efficiencies of current materials. Weak transition dipole moments between 4f orbitals hinder both photon absorption and emission. Here, we introduce a novel way to increase the radiative transition rates in Yb,Er-based upconverting nanoparticles based on local symmetry distortion. Beginning from a host matrix of the well-studied hexagonal (β)-phase NaYF 4 , we incrementally remove Y 3+ ions and cosubstitute for them a 1:1 mixture of Gd 3+ and Lu 3+ . These two ions act to expand and contract the lattice, respectively, inducing local-level distortion while maintaining the average host structure. We synthesize a range of β-NaY 0.8-2 x Gd x Lu x F 4 :Yb 0.18 Er 0.02 nanoparticles and experimentally confirm that particle size, phase, global structure, and Yb 3+ and Er 3+ concentrations remain constant as x is varied. Upconversion quantum yield is probed as the degree of cosubstitution is varied from x = 0 to x = 0.24. We achieve a maximum quantum yield value of 0.074% under 63 W/cm 2 of excitation power density, representing a 1.6× enhancement over the unmodified particles and the highest measured value for near-infrared-to-visible upconversion in sub-25 nm unshelled nanoparticles. We also investigate upconversion emission at the single-particle level and report record improvements in emission intensity for sub-50 nm particles. Radiative rate enhancements are confirmed by measuring excited-state lifetimes. The approach described herein can be used in combination with more established methods of efficiency improvement, such as adding passivating shells or coupling to plasmonic nanoattenas, to further boost the upconversion quantum yield.

36 MATERIALS SCIENCE↗

Third-order correlation function and ghost imaging of chaotic thermal light in the photon counting regime

In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is 6 times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution-enhanced subpixel phase retrieval method

Phase retrieval is a wavefront sensing method that uses a series of intensity images to reconstruct the wavefront. The resolution of phase retrieval testing is limited mainly by the resolution of intensity images captured by CCD cameras. A subpixel phase retrieval method is presented to retrieve the wave field at subpixel resolution by using the information of a sequence of low-resolution images captured along the propagation direction. In this method, the sampling interval for the wave field under test is smaller than the CCD pixel size in phase reconstruction. The wave field is recovered at subpixel resolution by utilizing the energy conservation relationship between CCD pixels and their subpixels by the subpixel phase retrieval (SPR) algorithm. Numerical experiments have shown that more than a fourfold resolution enhancement can be achieved. The method has also been studied in some experiments under noisy and off-axis conditions. A mirror surface testing experiment was conducted to demonstrate the performance of SPR in the real world. The results of these experiments have shown the effectiveness and robustness of this method. SPR allows low-resolution images to be used to retrieve high-resolution wave fields and will be useful in testing wave fields from large objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magneto-optical imaging technique for hostile environments: The ghost imaging approach

In this paper, we develop an approach to magneto optical imaging (MOI), applying a ghost imaging (GI) protocol to perform Faraday microscopy. MOI is of the utmost importance for the investigation of magnetic properties of material samples, through Weiss domains shape, dimension and dynamics analysis. Nevertheless, in some extreme conditions such as cryogenic temperatures or high magnetic field applications, there exists a lack of domain images due to the difficulty in creating an efficient imaging system in such environments. Here, we present an innovative MOI technique that separates the imaging optical path from the one illuminating the object. The technique is based on thermal light GI and exploits correlations between light beams to retrieve the image of magnetic domains. As a proof of principle, the proposed technique is applied to the Faraday magneto-optical observation of the remanence domain structure of an yttrium iron garnet sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating Irregular Source Geometries for Ionian Plumes

Volcanic plumes on Io respresent a complex rarefied flow into a near-vacuum in the presence of gravity. A 3D Direct Simulation Monte Carlo (DSMC) method is used to investigate the gas dynamics of such plumes, with a focus on the effects of source geometry on far-field deposition patterns. A rectangular slit and a semicircular half annulus are simulated to illustrate general principles, especially the effects of vent curvature on deposition ring structure. Then two possible models for the giant plume Pele are presented. One is a curved line source corresponding to an IR image of a particularly hot region in the volcano's caldera and the other is a large area source corresponding to the entire caldera. The former is seen to produce the features seen in observations of Pele's ring, but with an error in orientation. The latter corrects the error in orientation, but loses some structure. A hybrid simulation of 3D slit flow is also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Class of backpropagation techniques for limited-angle reconstruction in microwave tomography

Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction using FBPP, full 360° angular coverage is necessary. However, it has been shown that using some inherent redundancies in the projection data in a tomographic setup, accurate reconstruction is still possible with 270° coverage which is called the minimal-scan angle range. This can be done by applying weighing functions (or filters) on projection data of the object to eliminate the redundancies and accurately reconstruct the image from 270° coverage. This paper demonstrates procedures to generate many general classes of these weighing filters. These are all equivalent at 270° coverage but vary in performance at lower angular coverages and in presence of noise. This paper does a comparative analysis of different filters when angular coverage is lower than minimal-scan angle of 270°. Simulation studies have been done to find optimum weight filters for sub-minimal angular coverage (<270°)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-wavelength imaging and field mapping via electromagnetically induced transparency and Autler-Townes splitting in Rydberg atoms

We present a technique for measuring radio-frequency (RF) electric field strengths with sub-wavelength resolution. We use Rydberg states of rubidium atoms to probe the RF field. The RF field causes an energy splitting of the Rydberg states via the Autler-Townes effect, and we detect the splitting via electromagnetically induced transparency (EIT). We use this technique to measure the electric field distribution inside a glass cylinder with applied RF fields at 17.04 GHz and 104.77 GHz. We achieve a spatial resolution of ≈100 μm, limited by the widths of the laser beams utilized for the EIT spectroscopy. We numerically simulate the fields in the glass cylinder and find good agreement with the measured fields. Our results suggest that this technique could be applied to image fields on a small spatial scale over a large range of frequencies, up into the sub-terahertz regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise Correlations in One-Dimensional Systems of Ultracold Fermions

Time of flight images reflect the momentum distribution of the atoms in the trap, but the spatial noise in the image holds information on more subtle correlations. Using bosonization, we study such correlations in generic 1D systems of ultracold fermions. We show how pairing as well as spin and charge density wave correlations may be identified and extracted from time of flight images. These incipient orders manifest themselves as power-law singularities in the noise correlations, that depend on the Luttinger parameters, which suggests a general experimental technique to obtain them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quickest ever single-step mechanosynthesis of Cd{sub 0.5}Zn{sub 0.5}S quantum dots: Nanostructure and optical characterizations

Highlights: Black-Right-Pointing-Pointer Cd{sub 0.5}Zn{sub 0.5}S QDs prepared in 30 min by ball-milling elemental Cd, Zn and S powders. Black-Right-Pointing-Pointer Microstructure characterization is made by XRD employing Rietveld method and HRTEM. Black-Right-Pointing-Pointer Stacking faults in QDs are ascertained both from Rietveld analysis and HRTEM images. Black-Right-Pointing-Pointer Presence of both cubic and hexagonal phases is confirmed by XRD and HRTEM. Black-Right-Pointing-Pointer Quantum confinement is ascertained by blue-shift and optical band gap increment. -- Abstract: Multiphase Cd{sub 0.5}Zn{sub 0.5}S quantum dots (QDs) are prepared for the first time in a record minimum time of 30 min by mechanical alloying the stoichiometric mixture of elemental Cd, Zn and S powders at room temperature under Ar. Initially, the hexagonal phase is formed as major one and then gradually transforms to the cubic phase which is formed coherently on the hexagonal lattice with (0 0 2){sub hexagonal}||(1 1 1){sub cubic} mechanism. In the course of milling up to 15 h, the molar ratio of cubic to hexagonal phase becomes {approx}0.7:0.3. Both high resolution transmission electron microscopy (HRTEM) and X-ray microstructure analyses reveal that these QDs are isotropic in nature, their size reduces to {approx}5 nm after 15 h of milling with a very narrow size distribution and they contain a significant amount of stacking and twin faults. These QDs show very distinct quantum confinement effect and their optical band gaps are higher than that of the bulk CdZnS.

36 MATERIALS SCIENCE↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Hard X-ray nanoimaging method using local diffraction from metal wire

A simple hard X-ray imaging method achieving a high spatial resolution is proposed. Images are obtained by scanning a metal wire through the wave field to be measured and rotating the sample to collect data for back projection calculations; the local diffraction occurring at the edges of the metal wire operates as a narrow line probe. In-line holograms of a test sample were obtained with a spatial resolution of better than 100 nm. The potential high spatial resolution of this method is shown by calculations using diffraction theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wannier-Stark states in a superlattice of InAs/GaAs quantum dots

Electron and hole emission from states of a ten-layer system of tunneling-coupled vertically correlated InAs/GaAs quantum dots (QDs) is studied experimentally by capacitance-voltage measurements and deep-level transient spectroscopy. The thickness of GaAs interlayers separating sheets of InAs QDs was {approx}3 nm, as determined from transmission electron microscope images. It is found that the periodic multimo-dal DLTS spectrum of this structure exhibits a pronounced linear shift as the reverse-bias voltage U{sub r} applied to the structure is varied. The observed behavior is a manifestation of the Wannier-Stark effect in the InAs/GaAs superlattice, where the presence of an external electric field leads to the suppression of coupling between the wave functions of electron states forming the miniband and to the appearance of a series of discrete levels called Wannier-Stark ladder states.

36 MATERIALS SCIENCE↗

Quantum Vision Transformers for Quark–Gluon Classification

We introduce a hybrid quantum-classical vision transformer architecture, notable for its integration of variational quantum circuits within both the attention mechanism and the multi-layer perceptrons. The research addresses the critical challenge of computational efficiency and resource constraints in analyzing data from the upcoming High Luminosity Large Hadron Collider, presenting the architecture as a potential solution. In particular, we evaluate our method by applying the model to multi-detector jet images from CMS Open Data. The goal is to distinguish quark-initiated from gluon-initiated jets. We successfully train the quantum model and evaluate it via numerical simulations. Using this approach, we achieve classification performance almost on par with the one obtained with the completely classical architecture, considering a similar number of parameters.

Comajoan Cara, Marçal (ORCID:0009000126263752)↗