Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Integrating Crack Detection and Pipe Shape Optimization for Enhanced Sewage System Durability

Crack detection in underground reinforced concrete pipes has been essential in determining the state of stormwater infrastructure. Detection models have been implemented for detecting cracks and other defects in pipes using CCTV footage for stormwater drainage systems. In addition, Finite element models have been used to determine optimum shapes and pipe thickness for different boundary conditions such as header pipes in power plants. The concept of shape optimization emerges as a crucial factor in power plant design and operation, with the potential to maximize performance while minimizing the use of materials. Shape optimization not only enhances efficiency but also contributes to reducing the environmental footprint. This paper discusses the integration of both topics by using the cracks detected in underground pipes as boundary conditions for shape optimization of the pipes. A machine learning model has been developed which uses limited data for training and outlines the location of detected cracks. A shape optimization methodology is proposed in which ANSYS modules are used to analyze fluid flow and then optimize the shape of the pipe. The crack detection model developed has been applied to a crack detected in lab setting and machine learning model used has an accuracy of 98% using a random forest algorithm.

20 FOSSIL-FUELED POWER PLANTS↗

Tracer techniques for urine volume determination and urine collection and sampling back-up system

The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

Ramirez, R. V.↗

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Derivative-free stochastic optimization via adaptive sampling strategies

In this paper, we present a novel derivative-free framework for solving unconstrained stochastic optimization problems. Many problems in fields ranging from simulation optimization to reinforcement learning to quantum computing involve settings where only stochastic function values are obtained via a zeroth-order oracle, which has no available gradient information and necessitates the usage of derivative-free optimization methodologies. Our approach includes estimating gradients using stochastic function evaluations and integrating adaptive sampling techniques to control the accuracy in these stochastic approximations. Our framework encapsulates several gradient estimation techniques, including standard finite-difference, Gaussian smoothing, sphere smoothing, randomized coordinate finite-difference, and randomized subspace finite-difference methods. We provide theoretical convergence guarantees for our framework and analyze the worst-case iteration and sample complexities associated with each gradient estimation method. Finally, we demonstrate the empirical performance of the methods on logistic regression and nonlinear least squares problems.

Adaptive sampling↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Optimization of spectroscopic surveys for testing non-Gaussianity

We investigate optimization strategies to measure primordial non-Gaussianity with future spectroscopic surveys. We forecast measurements coming from the 3D galaxy power spectrum and compute constraints on primordial non-Gaussianity parameters f{sub NL} and n{sub NG}. After studying the dependence on those parameters upon survey specifications such as redshift range, area, number density, we assume a reference mock survey and investigate the trade-off between number density and area surveyed. We then define the observational requirements to reach the detection of f{sub NL} of order 1. Our results show that power spectrum constraints on non-Gaussianity from future spectroscopic surveys can improve on current CMB limits, but the multi-tracer technique and higher order correlations will be needed in order to reach an even better precision in the measurements of the non-Gaussianity parameter f{sub NL}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-355: Efficient Scatter Correction for Direct Ray-Tracing Based Dose Calculation

Purpose: To propose a scatter correction method with linear computational complexity for direct-ray-tracing (DRT) based dose calculation. Due to its speed and simplicity, DRT is widely used as a dose engine in the treatment planning system (TPS) and monitor unit (MU) verification software, where heterogeneity correction is applied by radiological distance scaling. However, such correction only accounts for attenuation but not scatter difference, causing the DRT algorithm less accurate than the model-based algorithms for small field size in heterogeneous media. Methods: Inspired by the convolution formula derived from an exponential kernel as is typically done in the collapsed-cone-convolution-superposition (CCCS) method, we redesigned the ray tracing component as the sum of TERMA scaled by a local deposition factor, which is linear with respect to density, and dose of the previous voxel scaled by a remote deposition factor, D(i)=aρ(i)T(i)+(b+c(ρ(i)-1))D(i-1),where T(i)=e(-αr(i)+β(r(i))2) and r(i)=Σ-(j=1,..,i)ρ(j).The two factors together with TERMA can be expressed in terms of 5 parameters, which are subsequently optimized by curve fitting using digital phantoms for each field size and each beam energy. Results: The proposed algorithm was implemented for the Fluence-Convolution-Broad-Beam (FCBB) dose engine and evaluated using digital slab phantoms and clinical CT data. Compared with the gold standard calculation, dose deviations were improved from 20% to 2% in the low density regions of the slab phantoms for the 1-cm field size, and within 2% for over 95% of the volume with the largest discrepancy at the interface for the clinical lung case. Conclusion: We developed a simple recursive formula for scatter correction for the DRT-based dose calculation with much improved accuracy, especially for small field size, while still keeping calculation to linear complexity. The proposed calculator is fast, yet accurate, which is crucial for dose updating in IMRT optimization.

60 APPLIED LIFE SCIENCES↗

True Zero Degree Incident Implants on VIISta3000

The deliberate use of channeling to control depth profiles has come of age in the application to CMOS imaging sensor device manufacturing. In order to enable the true zero implant application on VIISta3000, we have optimized beam incidence angle control, using beam optics models and experimental measurements. The experiment measurement and the beam optics analysis results agree, showing a variation of less than 0.03 deg. (1{sigma}) across the wafer and from wafer to wafer. Achieving this accuracy in a manufacturing environment requires careful calibration and tight control of the collimator magnet and the mechanical scan system. In this paper we discuss the root cause of beam incidence angle variation on VIISta3000 and explain the calibration and optimization used to insure the consistent minimized beam incidence angle. We show experimental data, including ThermaWave and SIMS profiles.

43 PARTICLE ACCELERATORS↗

SolarPILOT: A power tower solar field layout and characterization tool

This paper develops and demonstrates a new SolarPower tower Integrated Layout and Optimization Tool (SolarPILOT). The tool uses the analytical flux image Hermite series approximation originally implemented in the DELSOL3 software developed by Sandia National Laboratory in the early 1980s. By applying the analytical model to individual heliostat images rather than large groups or zones of heliostats, SolarPILOT can characterize a wide variety of heliostat field layouts. The individual heliostat modeling approach increases computational expense in comparison with DELSOL3, so SolarPILOT implements a number of improvements to the analytical approximation method to improve model accuracy and computational efficiency. This paper discusses several of these methods, including dynamic heliostat grouping to reduce the expense of intercept factor evaluation, approximation of annual productivity with a subset of time steps throughout the year, polygon clipping to accurately calculate inter-heliostat shadowing and blocking, receiver and tower geometry optimization, and a trigonometric image transformation technique that ensures model accuracy for small heliostats. SolarPILOT also integrates a Monte-Carlo ray tracing engine (SolTrace), providing improved receiver optical modeling capability, a user-friendly front end for geometry definition, and side-by-side validation of the analytical algorithms.

14 SOLAR ENERGY↗

Numerical integrators for Lagrangian oceanography

Abstract. A common task in Lagrangian oceanography is to calculate a large number of drifter trajectories from a velocity field precalculated with an ocean model. Mathematically, this is simply numerical integration of an ordinary differential equation (ODE), for which a wide range of different methods exist. However, the discrete nature of the modelled ocean currents requires interpolation of the velocity field in both space and time, and the choice of interpolation scheme has implications for the accuracy and efficiency of the different numerical ODE methods. We investigate trajectory calculation in modelled ocean currents with 800 m, 4 km, and 20 km horizontal resolution, in combination with linear, cubic and quintic spline interpolation. We use fixed-step Runge–Kutta integrators of orders 1–4, as well as three variable-step Runge–Kutta methods (Bogacki–Shampine 3(2), Dormand–Prince 5(4) and 8(7)). Additionally, we design and test modified special-purpose variants of the three variable-step integrators, which are better able to handle discontinuous derivatives in an interpolated velocity field. Our results show that the optimal choice of ODE integrator depends on the resolution of the ocean model, the degree of interpolation, and the desired accuracy. For cubic interpolation, the commonly used Dormand–Prince 5(4) is rarely the most efficient choice. We find that in many cases, our special-purpose integrators can improve accuracy by many orders of magnitude over their standard counterparts, with no increase in computational effort. Equivalently, the special-purpose integrators can provide the same accuracy as standard methods at a reduced computational cost. The best results are seen for coarser resolutions (4 and 20 km), thus the special-purpose integrators are particularly advantageous for research using regional to global ocean models to compute large numbers of trajectories. Our results are also applicable to trajectory computations on data from atmospheric models.

58 GEOSCIENCES↗

Optimization and Commercialization of the Juvenile Eel/Lamprey Acoustic Transmitter and Micro-battery (Abstract)

Enhance studies to track in 3D and sub-meter accuracy the movements of sensitive species and early life stages of fish to advance understanding of migration timing and behaviors, habitat use, and survival rates, resulting in more informed management decisions regarding new and existing hydroelectric facilities and better designs of new hydropower systems that minimize or avoid environmental impacts.

13 HYDRO ENERGY↗

Wayne—A Simulator for HST WFC3 IR Grism Spectroscopy

Wayne is an algorithm that simulates Hubble Space Telescope Wide Field Camera 3 (WFC3) grism spectroscopic frames, including sources of noise and systematics. It can simulate both staring and spatial scan modes, and observations such as the transit and the eclipse of an exoplanet. Unlike many other instrument simulators, the focus of Wayne is on creating frames with realistic systematics in order to test the effectiveness of different data analysis methods in a variety of different scenarios. This approach is critical for method validation and optimizing observing strategies. In this paper we describe the implementation of Wayne for WFC3 in the near-infrared channel with the G102 and G141 grisms. We compare the simulations to real data obtained for the exoplanet HD 209458b, to verify the accuracy of the simulation. The software is now available as open source at https://github.com/ucl-exoplanets/wayne.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Charge Method for Reaction Fields in a Hybrid Ion-Channel Model

A multiple-image method is proposed to approximate the reaction-field potential of a source charge inside a finite length cylinder due to the electric polarization of the surrounding membrane and bulk water. When applied to a hybrid ion-channel model, this method allows a fast and accurate treatment of the electrostatic interactions of protein with membrane and solvent. To treat the channel/membrane interface boundary conditions of the electric potential, an optimization approach is used to derive image charges by fitting the reaction-field potential expressed in terms of cylindric harmonics. Meanwhile, additional image charges are introduced to satisfy the boundary conditions at the planar membrane interfaces. In the end, we convert the electrostatic interaction problem in a complex inhomogeneous system of ion channel/membrane/water into one in a homogeneous free space embedded with discrete charges (the source charge and image charges). The accuracy of this method is then validated numerically in calculating the solvation self-energy of a point charge.

59 BASIC BIOLOGICAL SCIENCES↗

A vertically integrated pixel readout device for the Vertex Detector at the International Linear Collider

3D-Integrated Circuit technology enables higher densities of electronic circuitry per unit area without the use of nanoscale processes. It is advantageous for mixed mode design with precise analog circuitry because processes with conservative feature sizes typically present lower process dispersions and tolerate higher power supply voltages, resulting in larger separation of a signal from the noise floor. Heterogeneous wafers (different foundries or different process families) may be combined with some 3D integration methods, leading to the optimization of each tier in the 3D stack. Tracking and vertexing in future High-Energy Physics (HEP) experiments involves construction of detectors composed of up to a few billions of channels. Readout electronics must record the position and time of each measurement with the highest achievable precision. This paper reviews a prototype of the first 3D readout chip for HEP, designed for a vertex detector at the International Linear Collider. The prototype features 20 x 20 {micro}m{sup 2} pixels, laid out in an array of 64 x 64 elements and was fabricated in a 3-tier 0.18 {micro}m Fully Depleted SOI CMOS process at MIT-Lincoln Laboratory. The tests showed correct functional operation of the structure. The chip performs a zero-suppressed readout. Successive submissions are planned in a commercial 3D bulk 0.13 {micro}m CMOS process to overcome some of the disadvantages of an FDSOI process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of photodetector performance for plastic scintillation dosimetry

Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

60 APPLIED LIFE SCIENCES↗

Parallelized domain decomposition for multi-dimensional Lagrangian random walk mass-transfer particle tracking schemes

Lagrangian particle tracking schemes allow a wide range of flow and transport processes to be simulated accurately, but a major challenge is numerically implementing the inter-particle interactions in an efficient manner. This article develops a multi-dimensional, parallelized domain decomposition (DDC) strategy for mass-transfer particle tracking (MTPT) methods in which particles exchange mass dynamically. We show that this can be efficiently parallelized by employing large numbers of CPU cores to accelerate run times. In order to validate the approach and our theoretical predictions we focus our efforts on a well-known benchmark problem with pure diffusion, where analytical solutions in any number of dimensions are well established. In this work, we investigate different procedures for “tiling” the domain in two and three dimensions (2-D and 3-D), as this type of formal DDC construction is currently limited to 1-D. An optimal tiling is prescribed based on physical problem parameters and the number of available CPU cores, as each tiling provides distinct results in both accuracy and run time. We further extend the most efficient technique to 3-D for comparison, leading to an analytical discussion of the effect of dimensionality on strategies for implementing DDC schemes. Increasing computational resources (cores) within the DDC method produces a trade-off between inter-node communication and on-node work. For an optimally subdivided diffusion problem, the 2-D parallelized algorithm achieves nearly perfect linear speedup in comparison with the serial run-up to around 2700 cores, reducing a 5 h simulation to 8 s, while the 3-D algorithm maintains appreciable speedup up to 1700 cores.

97 MATHEMATICS AND COMPUTING↗

Accurate interlaminar stress recovery from finite element analysis

The accuracy and robustness of a two-dimensional smoothing methodology is examined for the problem of recovering accurate interlaminar shear stress distributions in laminated composite and sandwich plates. The smoothing methodology is based on a variational formulation which combines discrete least-squares and penalty-constraint functionals in a single variational form. The smoothing analysis utilizes optimal strains computed at discrete locations in a finite element analysis. These discrete strain data are smoothed with a smoothing element discretization, producing superior accuracy strains and their first gradients. The approach enables the resulting smooth strain field to be practically C1-continuous throughout the domain of smoothing, exhibiting superconvergent properties of the smoothed quantity. The continuous strain gradients are also obtained directly from the solution. The recovered strain gradients are subsequently employed in the integration o equilibrium equations to obtain accurate interlaminar shear stresses. The problem is a simply-supported rectangular plate under a doubly sinusoidal load. The problem has an exact analytic solution which serves as a measure of goodness of the recovered interlaminar shear stresses. The method has the versatility of being applicable to the analysis of rather general and complex structures built of distinct components and materials, such as found in aircraft design. For these types of structures, the smoothing is achieved with 'patches', each patch covering the domain in which the smoothed quantity is physically continuous.

Tessler, Alexander↗

Systematic Improvement of Quantum Monte Carlo Calculations in Transition Metal Oxides: sCI-Driven Wavefunction Optimization for Reliable Band Gap Prediction

Accurate determination of the electronic properties of correlated oxides remains a significant challenge for computational theory. Traditional Hubbard-corrected density functional theory (DFT+U) frequently encounters limitations in precisely capturing electron correlation, particularly in predicting band gaps. We introduce a systematic methodology to enhance the accuracy of diffusion Monte Carlo (DMC) simulations for both ground and excited states, focusing on LiCoO 2 as a case study. By employing a selected configuration interaction (sCI) approach, we demonstrate the capability to optimize wavefunctions beyond the constraints of single-reference DFT+U trial wavefunctions. Here, we show that the sCI framework enables accurate prediction of band gaps in LiCoO 2 , closely aligning with experimental values and substantially improving traditional computational methods. The study uncovers a nuanced mixed state of t 2g and e g orbitals at the band edges that is not captured by conventional single-reference methods, further elucidating the limitations of PBE+U in describing d-d excitations. Our findings advocate for the adoption of beyond-DFT methodologies, such as sCI, to capture the essential physics of excited-state wavefunctions in strongly correlated materials. The improved accuracy in band gap predictions and the ability to generate more reliable trial wavefunctions for DMC calculations underscore the potential of this approach for broader applications in the study of correlated oxides. This work not only provides a pathway for more accurate simulations of electronic structures in complex materials but also suggests a framework for future investigations of the excited states of other challenging systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗