Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Overview of the NASA Wallops Flight Facility Mobile Range Control System

The NASA GSFC's Wallops Flight Facility (WFF) Mobile Range Control System (MRCS) is based on the functionality of the WFF Range Control Center at Wallops Island, Virginia. The MRCS provides real time instantaneous impact predictions, real time flight performance data, and other critical information needed by mission and range safety personnel in support of range operations at remote launch sites. The MRCS integrates a PC telemetry processing system (TELPro), a PC radar processing system (PCDQS), multiple Silicon Graphics display workstations (IRIS), and communication links within a mobile van for worldwide support of orbital, suborbital, and aircraft missions. This paper describes the MRCS configuration; the TELPro's capability to provide single/dual telemetry tracking and vehicle state data processing; the PCDQS' capability to provide real time positional data and instantaneous impact prediction for up to 8 data sources; and the IRIS' user interface for setup/display options. With portability, PC-based data processing, high resolution graphics, and flexible multiple source support, the MRCS system is proving to be responsive to the ever-changing needs of a variety of increasingly complex missions.

Davis, Rodney A.↗

Distribution Development for the RDX Regional Model at Los Alamos National Laboratory - 20385

Representing uncertainty in model inputs often means finding a balance between uncertainty and physical reality. Developing wide distributions may seem conservative in principle, but this approach may lead to unrealistic model results. Characterizing the current state of knowledge of stochastic inputs presents many challenges, especially if the data available are limited or have limited relevance to the site. Relationships among these inputs may also be important to represent but are typically complex or difficult to define. Often special adjustments must be made to account for reduced credibility in particular data. If parameters are strongly related to one another, a correlation structure may be developed for input to the model. Other techniques such as regression models may be used to incorporate relationships between the information available and the desired parameters. The process of developing distributions must consider details of the model in terms of what the distribution is meant to represent. This paper uses the example of a probabilistic fate and transport model for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in the regional aquifer at Los Alamos National Laboratory (LANL). For many parameters, a single draw is applied to all space and time over which the model is run, for a single iteration. This simplification is often made for many reasons, and can often be beneficial, but also adds additional complexity in the distribution development process. Defining the distributional goals as they relate to the modeling process is an important step, which should take place prior to evaluation of the data. Usually, the distributions developed are meant to characterize the average value of the parameter over the spatial and temporal domain of the model. Distribution development requires consideration of many sources of information on the parameter where available, ideally from multiple references. Examples of different sources include data from different references but also from different conditions, measurement methods, or experimental types. Depending on these conditions and the reliability or relevance of particular references, different sources of data may each contribute valuable information but have varying relevance to the site. In these cases, weighting data unequally is a useful way to incorporate this information. As an example, aqueous dispersivity data are available for a variety of rock types. Only a few values are available for the desired rock type, and this is not enough to develop a distribution. Therefore, dispersivity values from other rock types are included in distribution development but are down-weighted such that the best data have the most influence on the distribution developed. In another case, K{sub d} distributions in the model are meant to represent a known composition of multiple soil types. Data from these materials are weighted accordingly to develop a distribution for the weighted average K{sub d} across soil types. Other cases include varying reliability of different sources, and weighting data according to the confidence in these sources. In some cases, input parameters are correlated with one another. An example is advective porosity, which is positively correlated with total porosity and must be less than total porosity. Paired data with both parameters must exist to discern the relationship between the two parameters and if it is necessary to build a correlation structure into the model. In general, correlated parameters may be represented in the model by a multivariate distribution, or perhaps more desirably, capturing the correlation within the developed distributions which may be treated as independent from one another. In the example of porosity, this can be done by transforming advective porosity into a proportion of total porosity which may be drawn independently from the distribution of total porosity. This paper explores how complex data and correlations can be incorporated to meet the distributional goals of the model, using the RDX regional model as a detailed example. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FOREGROUND PREDICTIONS FOR THE COSMIC MICROWAVE BACKGROUND POWER SPECTRUM FROM MEASUREMENTS OF FAINT INVERTED RADIO SOURCES AT 5 GHz

We present measurements of a population of matched radio sources at 1.4 and 5 GHz down to a flux limit of 1.5 mJy in 7 deg{sup 2} of the NOAO Deep Field South. We find a significant fraction of sources with inverted spectral indices that all have 1.4 GHz fluxes less than 10 mJy and are therefore too faint to have been detected and included in previous radio source count models that are matched at multiple frequencies. Combined with the matched source population at 1.4 and 5 GHz in 1 deg{sup -2} in the ATESP survey, we update models for the 5 GHz differential number counts and distributions of spectral indices in 5 GHz flux bins that can be used to estimate the unresolved point source contribution to the cosmic microwave background temperature anisotropies. We find a shallower logarithmic slope in the 5 GHz differential counts than in previously published models for fluxes {approx}< 100 mJy as well as larger fractions of inverted spectral indices at these fluxes. Because the Planck flux limit for resolved sources is larger than 100 mJy in all channels, our modified number counts yield at most a 10% change in the predicted Poisson contribution to the Planck temperature power spectrum. For a flux cut of 5 mJy with the South Pole Telescope and a flux cut of 20 mJy with the Atacama Cosmology Telescope, we predict a {approx}30% and {approx}10% increase, respectively, in the radio source Poisson power in the lowest frequency channels of each experiment relative to that predicted by previous models.

79 ASTRONOMY AND ASTROPHYSICS↗

Solid-State Lighting Using Side-by-Side White Phosphorescent Organic Light-Emitting Diodes

White organic light-emitting diodes (WOLEDs) have become increasingly popular for use in solid-state illumination, where diffuse, large area light sources that achieve a high color rendering index and luminous power efficiency are desirable. Color-tunable emission, where the light source combines emission from multiple, separately addressed color elements, is conveniently provided by WOLEDs for the purpose of adapting the lighting source to a particular illumination requirement. In this work, we demonstrate a method for side-by-side positioning of monochromatic blue and yellow phosphorescent OLED stripes that are combined to create tunable white light, using a high resolution mechanical peel-off patterning method. We achieve a peak luminous power efficiency of 17.1 ± 0.3 lm W –1 and an external quantum efficiency of 11.8 ± 0.2% and demonstrate color tunability of the 1960 Commission Internationale d’Eclairage chromaticity coordinates from (u,v) = (0.33,0.36) to (0.12,0.32). This corresponds to a tuning rnge of the color rendering index from 74 ± 1 to 86 ± 1 and the correlated color temperature from 2000 to 8000 ± 500 K. Here, due to the nondestructive nature of the peel-off technique, patterned devices exhibit a lifetime comparable to conventional, shadow mask-patterned devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter

Active-mode assay systems are widely used for the safeguards of uranium items to verify compliance with the Non-Proliferation Treaty. Systems such as the Active-Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL) use americium-lithium (AmLi) neutron sources to induce fissions which are measured to determine the sample mass. These systems have historically relied on calibrations derived from well-defined standards. Recently, restricted access to standards or more difficult measurements have resulted in a reliance on modeling and simulation for the calibration of systems, which introduces potential simulation biases. Furthermore, the AmLi source energy spectra commonly used in the safeguards community do not accurately represent measurement results and the spectrum uncertainty can represent a large contribution to the total modeling uncertainty in active-mode systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A GEOMETRICALLY SUPPORTED z ∼ 10 CANDIDATE MULTIPLY IMAGED BY THE HUBBLE FRONTIER FIELDS CLUSTER A2744

The deflection angles of lensed sources increase with their distance behind a given lens. We utilize this geometric effect to corroborate the z {sub phot} ≅ 9.8 photometric redshift estimate of a faint near-IR dropout, triply imaged by the massive galaxy cluster A2744 in deep Hubble Frontier Fields images. The multiple images of this source follow the same symmetry as other nearby sets of multiple images that bracket the critical curves and have well-defined redshifts (up to z {sub spec} ≅ 3.6), but with larger deflection angles, indicating that this source must lie at a higher redshift. Similarly, our different parametric and non-parametric lens models all require this object be at z ≳ 4, with at least 95% confidence, thoroughly excluding the possibility of lower-redshift interlopers. To study the properties of this source, we correct the two brighter images for their magnifications, leading to a star formation rate of ∼0.3 M {sub ☉} yr{sup –1}, a stellar mass of ∼4 × 10{sup 7} M {sub ☉}, and an age of ≲ 220 Myr (95% confidence). The intrinsic apparent magnitude is 29.9 AB (F160W), and the rest-frame UV (∼1500 Å) absolute magnitude is M {sub UV,} {sub AB} = –17.6. This corresponds to ∼0.1 L{sub z=8}{sup ∗} (∼0.2 L{sub z=10}{sup ∗}, adopting dM*/dz ∼ 0.45), making this candidate one of the least luminous galaxies discovered at z ∼ 10.

79 ASTRONOMY AND ASTROPHYSICS↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray imaging using avalanche multiplication in amorphous selenium: Investigation of intrinsic avalanche noise

The flat-panel detector (FPD) is the state-of-the-art detector for digital radiography. The FPD can acquire images in real-time, has superior spatial resolution, and is free of the problems of x-ray image intensifiers--veiling glare, pin-cushion and magnetic distortion. However, FPDs suffer from poor signal to noise ratio performance at typical fluoroscopic exposure rates where the quantum noise is reduced to the point that it becomes comparable to the fixed electronic noise. It has been shown previously that avalanche multiplication gain in amorphous selenium (a-Se) can provide the necessary amplification to overcome the electronic noise of the FPD. Avalanche multiplication, however, comes with its own intrinsic contribution to the noise in the form of gain fluctuation noise. In this article a cascaded systems analysis is used to present a modified metric related to the detective quantum efficiency. The modified metric is used to study a diagnostic x-ray imaging system in the presence of intrinsic avalanche multiplication noise independently from other noise sources, such as electronic noise. An indirect conversion imaging system is considered to make the study independent of other avalanche multiplication related noise sources, such as the fluctuations arising from the depth of x-ray absorption. In this case all the avalanche events are initiated at the surface of the avalanche layer, and there are no fluctuations in the depth of absorption. Experiments on an indirect conversion x-ray imaging system using avalanche multiplication in a layer of a-Se are also presented. The cascaded systems analysis shows that intrinsic noise of avalanche multiplication will not have any deleterious influence on detector performance at zero spatial frequency in x-ray imaging provided the product of conversion gain, coupling efficiency, and optical quantum efficiency are much greater than a factor of 2. The experimental results show that avalanche multiplication in a-Se behaves as an intrinsic noise free avalanche multiplication, in accordance with our theory. Provided good coupling efficiency and high optical quantum efficiency are maintained, avalanche multiplication in a-Se has the potential to increase the gain and make negligible contribution to the noise, thereby improving the performance of indirect FPDs in fluoroscopy.

36 MATERIALS SCIENCE↗

A single-sample method for normalizing and combining full-resolution copy numbers from multiple platforms, labs and analysis methods

Motivation: The rapid expansion of whole-genome copy number (CN) studies brings a demand for increased precision and resolution of CN estimates. Recent studies have obtained CN estimates from more than one platform for the same set of samples, and it is natural to want to combine the different estimates in order to meet this demand. Estimates from different platforms show different degrees of attenuation of the true CN changes. Similar differences can be observed in CNs from the same platform run in different labs, or in the same lab, with different analytical methods. This is the reason why it is not straightforward to combine CN estimates from different sources (platforms, labs and analysis methods). Results: We propose a single-sample multi source normalization that brings full-resolution CN estimates to the same scale across sources. The normalized CNs are such that for any underlying CN level, their mean level is the same regardless of the source, which make them better suited for being combined across sources, e.g. existing segmentation methods may be used to identify aberrant regions. We use microarray-based CN estimates from ‘The Cancer Genome Atlas’ (TCGA) project to illustrate and validate the method. We show that the normalized and combined data better separate two CN states at a given resolution. We conclude that it is possible to combine CNs from multiple sources such that the resolution becomes effectively larger, and when multiple platforms are combined, they also enhance the genome coverage by complementing each other in different regions. Availability: A bounded-memory implementation is available in aroma.cn.

59 BASIC BIOLOGICAL SCIENCES↗

Simulating NMIS Imaging and Fission-Mapping Measurements

The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source and Propagation Characteristics of Kilometric Continuum Observed with Multiple Satellites

Kilometric continuum radiation was first identified with the GEOTAIL Plasma Wave Instrument (PWI) as the high frequency extension of escaping continuum emissions in the frequency range from 100 kHz to 800 kHz. It consists of from a few to many narrow-band emissions. It was observed mainly near the magnetic equator, and its source was expected to be inside of the plasmapause and the topside equatorial region. Recently, data from the IMAGE Radio Plasma Imager (RPI) and Extreme ultraviolet (EUV) experiments have been used to show that kilometric continuum is generated at the plasmapause, in or near the magnetic equator, within a notch region, and have confirmed the expectation. Data from the CRRES PWI have also identified other sources from the equatorial density irregularities. An example of CRRES observations reveals a possibility that kilometric continuum has been radiated as a wide beam emission. The IMAGE and GEOTAIL simultaneous observations are not like the previous observations since they show it has been observed to have a very broad emission cone. It could also be the highest frequency continuum enhancement so far observed since it is associated with a high energy electron injection event.

Hashimoto, K.↗

One Galaxy Sample to Rule Them All: Halo Occupation Distribution Modeling of DES Year 3 Source Galaxies

Abstract For the joint analysis of second-order weak-lensing and galaxy clustering statistics, so-called 3 × 2 analyses, the selection and characterization of optimal galaxy samples is a major area of research. One promising choice is to use the same galaxy sample as lenses and sources, which reduces the systematics parameter space that describes the uncertainties related to galaxy samples. Such a “lens-equal-source” analysis significantly improves the self-calibration of photo- z systematics, leading to improved cosmological constraints. With the aim of enabling a lens-equal-source analysis on small scales, we investigate the halo–galaxy connection of DES Year 3 source galaxies. We develop a technique to construct mock source galaxy populations by matching COSMOS/UltraVISTA photometry to U niverse M achine galaxies. These mocks predict a source halo occupation distribution (HOD) that exhibits significant redshift evolution, nontrivial central incompleteness, and galaxy assembly bias. We produce multiple realizations of mock source galaxies drawn from the U niverse M achine posterior, with added uncertainties in the measured Dark Energy Survey photometry and galaxy shapes. We fit a modified HOD formalism to these realizations to produce priors on the galaxy–halo connection for cosmological analyses. We additionally train an emulator that predicts this HOD to ∼2% accuracy from redshift z = 0.1−1.3 that models the dependence of this HOD on (1) observational uncertainties in galaxy size and photometry and (2) uncertainties in the U niverse M achine predictions.

Salcedo, Andrés N. (ORCID:000000031420527X)↗

Direct three-dimensional coherently scattered x-ray microtomography

Purpose: It has been shown that coherently scattered x rays can be used to discriminate and identify specific components in a mixture of low atomic weight materials. The authors demonstrated a new method of doing coherently scattered x-ray tomography with a thin sheet of x ray. Methods: A collimated x-ray fan-beam, a parallel polycapillary collimator, and a phantom consisting of several biocompatible materials of low attenuation-based contrast were used to investigate the feasibility of the method. Because of the particular experimental setup, only the phantom translation perpendicular to the x-ray beam is needed and, thus, there is no need of Radon-type tomographic reconstruction, except for the correction of the attenuation to the primary and scattered x rays, which was performed by using a conventional attenuation-based tomographic image data set. The coherent scatter image contrast changes with momentum transfer among component materials in the specimen were investigated with multiple x-ray sources with narrow bandwidth spectra generated with anode and filter combinations of Cu/Ni (8 keV), Mo/Zr (18 keV), and Ag/Pd (22 keV) and at multiple scatter angles by orienting the detector and polycapillary collimator at different angles to the illuminating x ray. Results: The contrast among different materials changes with the x-ray source energy and the angle at which the image was measured. The coherent scatter profiles obtained from the coherent scatter images are consistent with the published results. Conclusions: This method can be used to directly generate the three-dimensional coherent scatter images of small animal, biopsies, or other small objects with low atomic weight biological or similar synthetic materials with low attenuation contrast. With equipment optimized, submillimeter spatial resolution may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerobic Respiration and Its Regulation in the Metal Reducer Shewanella oneidensis

Shewanella oneidensis MR-1 is a facultative anaerobe known for its ability to reduce metal oxides. Anaerobic respiration, especially metal reduction, has been the subject of extensive research. In contrast, S. oneidensis aerobic respiration has received less attention. S. oneidensis expresses cbb3- and aa3-type cytochrome c oxidases and a bd-type quinol oxidase. The aa3-type oxidase, which in other bacteria is the major oxygen reductase under oxygen replete conditions, does not appear to contribute to aerobic respiration and growth in S. oneidensis. Our results indicated that although the aa3-type oxidase does not play a role in aerobic growth on lactate, the preferred carbon source for S. oneidensis, it is involved in growth on pyruvate or acetate. These results highlight the importance of testing multiple carbon and energy sources when attempting to identify enzyme activities and mutant phenotypes. Several regulatory proteins contribute to the regulation of aerobic growth in S. oneidensis including CRP and ArcA. The 3',5'-cAMP phosphodiesterase (CpdA) appears to play a more significant role in aerobic growth than either CRP or ArcA, yet the deficiency does not appear to be the result of reduced oxidase genes expression. Interestingly, the ΔcpdA mutant was more deficient in aerobic respiration with several carbon sources tested compared to Δcrp, which was moderately deficient only in the presence of lactate. To identify the reason for ΔcpdA aerobic growth deficiency, we isolated a suppressor mutant with transposon insertion in SO_3550. Inactivation of this gene, which encodes an anti-sigma factor, restored aerobic growth in the cpdA mutant to wild-type levels. Inactivation of SO_3550 in wild-type cells, however, did not affect aerobic growth. The S. oneidensis genome encodes two additional CRP-like proteins that we designated CrpB and CrpC. Mutants that lack crpB and crpC were deficient in aerobic growth, but this deficiency was not due to the loss of oxidase gene expression.

59 BASIC BIOLOGICAL SCIENCES↗

Treatment of Chlorinated Solvents in Groundwater Beneath an Occupied Building at the Young-Rainey STAR Center, Pinellas, FL

Groundwater contamination, consisting of two dissolved-phase plumes originating from chlorinated solvent source areas, in the southeastern portion of the Young- Rainey Star Center (also known as the Pinellas County, Florida, Site) in Largo, Florida, has migrated beyond the property boundary, beneath the roadways, and beneath adjacent properties to the south and east. Groundwater contamination will persist as long as the onsite contaminant source remains. The origin of the contamination appears to be multiple long-term point sources beneath Building 100, a 4.5 ha (11 acre) building that housed manufacturing facilities during US DOE operations at the site. The site is now owned by Pinellas County, and most of the space inside the building is leased to private companies, so DOE chose not to conduct characterization or remediation through the floor of the building, instead choosing to conduct all work from outside the building. Injection of emulsified soybean oil and a microbial culture has been used at other areas of the site to accelerate naturally occurring bacterial processes that degrade groundwater contaminants to harmless compounds, and that same approach was chosen for this task. The technical approach consisted of installing horizontal wells from outside the building footprint, extending through and around the identified subsurface treatment areas, and terminating beneath the building. Two 107 m (350 ft) long wells, two 122 m (400 ft) long wells, and four 137 m (450 ft) long wells have been installed to intersect the inferred source areas and confirmed contaminant plumes beneath the building. DOE then injected emulsified vegetable oil and a microbial culture into the horizontal wells at each of several target areas beneath the building where the highest groundwater contaminant concentrations have been detected. The target areas are the northwest corner of the building between the old drum storage pad locations and monitoring well PIN12-S35B, the vicinity of former monitoring well PIN12-S57B, and hydraulically upgradient from the south plume and the east plume at the points where they exit from beneath the building. We describe the details of designing and constructing horizontal injection wells for bioremediation beneath a large, occupied industrial production facility, including lessons learned; technical, logistical, and environmental challenges; community relations; and regulatory relations. Because of the expected lag in biological acclimation and response, distance between the treatment areas and associated monitoring points, and low groundwater velocity, it will likely be years before the full impact of the project will be realized.

54 ENVIRONMENTAL SCIENCES↗

Treatment of Chlorinated Solvents in Groundwater Beneath an Occupied Building at The Young - Rainey STAR Center (Science, Technology, and Research Center) - 16342

Groundwater contamination, consisting of two dissolved-phase plumes originating from chlorinated solvent source areas, in the southeastern portion of the Young- Rainey Star Center (also known as the Pinellas County, Florida, Site) in Largo, Florida, has migrated beyond the property boundary, beneath the roadways, and beneath adjacent properties to the south and east. Groundwater contamination will persist as long as the onsite contaminant source remains. The origin of the contamination appears to be multiple long-term point sources beneath Building 100, a 4.5 ha (11 acre) building that housed manufacturing facilities during US DOE operations at the site. The site is now owned by Pinellas County, and most of the space inside the building is leased to private companies, so DOE chose not to conduct characterization or remediation through the floor of the building, instead choosing to conduct all work from outside the building. Injection of emulsified soybean oil and a microbial culture has been used at other areas of the site to accelerate naturally occurring bacterial processes that degrade groundwater contaminants to harmless compounds, and that same approach was chosen for this task. The technical approach consisted of installing horizontal wells from outside the building footprint, extending through and around the identified subsurface treatment areas, and terminating beneath the building. Two 107 m (350 ft) long wells, two 122 m (400 ft) long wells, and four 137 m (450 ft) long wells have been installed to intersect the inferred source areas and confirmed contaminant plumes beneath the building. DOE then injected emulsified vegetable oil and a microbial culture into the horizontal wells at each of several target areas beneath the building where the highest groundwater contaminant concentrations have been detected. The target areas are the northwest corner of the building between the old drum storage pad locations and monitoring well PIN12-S35B, the vicinity of former monitoring well PIN12-S57B, and hydraulically up-gradient from the south plume and the east plume at the points where they exit from beneath the building. We describe the details of designing and constructing horizontal injection wells for bioremediation beneath a large, occupied industrial production facility, including lessons learned; technical, logistical, and environmental challenges; community relations; and regulatory relations. Because of the expected lag in biological acclimation and response, distance between the treatment areas and associated monitoring points, and low groundwater velocity, it will likely be years before the full impact of the project will be realized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗